Summary
PRCOM20235206
Building Permit - Commercial
Issued - Partial
RESIDENCES AT BLACKWELL LLC
NEW MULTI-FAMILY
RESIDENCES AT BLACKWELL - BUILDING #2 67 Units, NEW APARTMENT BUILDING Mike Weisenborn 06/27/2024 10:48 AM - ISSUED PARTIAL PERMIT FOR FOUNDATION, UNDERGROUND AND UNDERSLAB ONLY.
10/10/2023
11/06/2023
Locations
Contacts
Jake Loveless, Address:21 SE 29TH TER  
Polar Aire Heating & Cooling Service, Address:400 S. Kansas Ave, Phone:(913) 782-8238  
KDM ELECTRICAL CONTRACTORS, Address:1103 NW CASEY BLVD STE C, Phone:(816) 443-5694  
BENCHMARK MECHANICAL LLC, Address:5 SW 4TH ST, Phone:(816) 524-5616  
NSPJ ARCHITECTS, Address:3515 W 75TH ST, SUITE 201, Phone:(913) 831-1415 Ext:278  
CFS ENGINEERS, Address:1421 EAST 104TH STREET STE 100, Phone:(816) 333-4477  
RESIDENCES AT BLACKWELL LLC, Address:21 SE 29TH TER  
Streamline General Contractors, Address:5 4TH ST SW  
scott@griffinriley.com  
Reviews
Review Type Outcome Est. Completion Date Completed
Alarm Plan Review Released for Construction 04/28/2025 04/28/2025
Craig Hill
Alarms connected to automatic sprinkler system
Informational
04/28/2025

2018 IFC 903.4.2- Alarms. Approved audible and visual devices shall be connected to every automatic sprinkler system. Such sprinkler water-flow alarm devices shall be activated by water flow equivalent to the flow of a single sprinkler of the smallest orifice size installed in the system. Listed alarm notification devices shall be provided on the exterior and interior of the building in an approved location. Where a fire alarm system is installed, actuation of the automatic sprinkler system shall actuate the building fire alarm system.
Alarm testing.
Informational
04/28/2025

2018 IFC 904.4.2- Alarm testing. Notification appliances, connections to fire alarm systems, and connections to approved supervising stations shall be tested in accordance with this section and Section 907 to verify proper operation. Call (816) 969-1300 24 hours in advance to schedule an alarm test. System must be monitored and pretested before scheduling.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for New Multi-Family $4,500.00 $4,500.00 Paid 06/26/2024
$40,475.00
Outstanding Fees Amount Paid Owing Date Paid
7232302-Residential License Tax Fee $28,429.44 $0.00 $28,429.44 Not Paid
9110078-Valuation Fee for New Multi-Family $35,975.00 $0.00 $35,975.00 Not Paid
$40,475.00


$64,404.44    Add Fees to My Cart
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Alarm Test Pending
Sprinkler - Hydrostatic Test Pending
Sprinkler - Flow Test Pending
Erosion Control Inspection Residential Pending
Piers/Caissons Inspection - Commercial Pending
Sewer Service Inspection Pending
Water Service Inspection Pending
Concrete Walls and Columns Inspection Pending
Misc
Corrective Action Required
08/16/2024
Foundation wall OK: -A/4 to G/4; cont. to M.3/7; rest of storm shelter f. wall -Elevator pit wall
Suspended Slab Inspection Pending
Misc
Informational
10/16/2024
Podium slab ok to pour pending approval of the on-site engineer
Underground Electrical Inspection - Commercial Pending
Misc
Corrective Action Required
12/27/2024
Building 2 level 1 electrical conduit from electrical room to out side of garage running south west ( incomplete)
Underground Plumbing Inspection - Commercial Pending
Misc
Corrective Action Required
02/25/2025
-Domestic and fire sprinkler lines from ~ 10 ft outside to building
Alarm Test Pending
Footing Inspection - Commercial Partial 7/23/2024 7/23/2024 07/23/2024
Misc
Informational
07/23/2024
Exterior wall footing-OK
Concrete Walls and Columns Inspection Partial 7/25/2024 07/25/2024
Misc
Corrective Action Required
07/25/2024
Foundation wall OK: -G/4 to A/4 **Install electrical service grounding electrode conductor at north end of building. Call for inspection before pouring
Concrete Walls and Columns Inspection Partial 7/26/2024 07/26/2024
Misc
Corrective Action Required
07/25/2024
Foundation wall OK: -G/4 to A/4
Concrete Walls and Columns Inspection Partial 7/31/2024 07/31/2024
Misc
Corrective Action Required
07/26/2024
Foundation wall OK: -A/4 to G/4; cont. to M.3/7
Footing Inspection - Commercial Partial 8/7/2024 8/7/2024 08/07/2024
Misc
Informational
07/23/2024
Exterior wall footing-OK Column footing and elevator pit on building C. PASSED 8/7/24 AF
Concrete Walls and Columns Inspection Partial 8/13/2024 8/13/2024 08/13/2024
Misc
Corrective Action Required
07/31/2024
Foundation wall OK: -A/4 to G/4; cont. to M.3/7 **8/13-site locked up. Inspection canceled
Concrete Walls and Columns Inspection Partial 8/16/2024 08/16/2024
Misc
Corrective Action Required
08/13/2024
Foundation wall OK: -A/4 to G/4; cont. to M.3/7 -Elevator pit wall **correction: install corner rebars per 3/S3.00
Concrete Walls and Columns Inspection Partial 8/16/2024 08/16/2024
Misc
Corrective Action Required
08/16/2024
Foundation wall OK: -A/4 to G/4; cont. to M.3/7; rest of storm shelter f. wall -Elevator pit wall
Underslab Plumbing Inspection - Commercial Failed 8/30/2024 08/30/2024
Misc
Corrective Action Required
08/30/2024
Pressure not holding
Underslab Plumbing Inspection - Commercial Passed 9/4/2024 9/4/2024 09/04/2024
Misc
Resolved
09/04/2024
Pressure not holding
Footing Inspection - Commercial Partial 9/24/2024 9/25/2024 09/25/2024
Misc
Informational
08/07/2024
Lower level foundation: -Exterior wall footing; column footing and elevator pit -Interior footing
Suspended Slab Inspection Partial 10/16/2024 10/16/2024 10/16/2024
Misc
Informational
10/16/2024
Podium slab ok to pour pending approval of the on-site engineer
Underslab Plumbing Inspection - Commercial Passed 12/11/2024 12/11/2024 12/11/2024
Misc
Informational
12/11/2024
Upper floor underslab plumbing OK
Footing Inspection - Commercial Partial 12/12/2024 12/12/2024 12/12/2024
Misc
Informational
09/25/2024
Lower level foundation: -Exterior wall footing; storm shelter column footing and elevator pit -Interior footing Upper level foundation:
Misc
Informational
12/12/2024
Inspected Interior grade beams building 2
Footing Inspection - Commercial Partial 12/18/2024 12/18/2024
Misc
Informational
12/12/2024
Lower level foundation: -Exterior wall footing; storm shelter column footing and elevator pit -Interior footing Upper level foundation: -Interior garage footing -Exterior grade beam, except at garage 9 and garages north of north stair A
Misc
Resolved
12/18/2024
Inspected Interior grade beams building 2
Footing Inspection - Commercial Partial 12/23/2024 12/23/2024 12/23/2024
Misc
Informational
12/12/2024
Lower level foundation: -Exterior wall footing; storm shelter column footing and elevator pit -Interior footing Upper level foundation: -Interior garage footing -Exterior grade beam, except at garage 9 and garage 1
Underground Electrical Inspection - Commercial Partial 12/27/2024 12/27/2024
Misc
Corrective Action Required
12/27/2024
Building 2 level 1 electrical conduit from electrical room to out side of garage running south west ( incomplete)
Underground Plumbing Inspection - Commercial Partial 2/25/2025 2/25/2025 02/25/2025
Misc
Corrective Action Required
02/25/2025
-Domestic and fire sprinkler lines from ~ 10 ft outside to building
Footing Inspection - Commercial Passed 3/7/2025 3/7/2025 03/07/2025
Misc
Informational
12/23/2024
Lower level foundation: -Exterior wall footing; storm shelter column footing and elevator pit -Interior footing Upper level foundation: -Interior garage footing -Exterior grade beam
Footing Inspection - Commercial Passed 3/10/2025 3/10/2025 03/10/2025
Misc
Informational
12/23/2024
Lower level foundation: -Exterior wall footing; storm shelter column footing and elevator pit -Interior footing Upper level foundation: -Interior garage footing -Exterior grade beam -Garage stem walls
Documents & Images
Date Uploaded File Type Document Name
06/26/2024 Receipt Receipt for transaction:2024-005225
06/27/2024 Letter DS Building Permit
07/23/2024 Letter INSPECTION SUMMARY
07/25/2024 Letter INSPECTION SUMMARY
07/26/2024 Letter INSPECTION SUMMARY
07/31/2024 Letter INSPECTION SUMMARY
08/07/2024 Letter INSPECTION SUMMARY
08/13/2024 Letter INSPECTION SUMMARY
08/16/2024 Letter INSPECTION SUMMARY
08/16/2024 Letter INSPECTION SUMMARY
08/30/2024 Letter INSPECTION SUMMARY
09/04/2024 Letter INSPECTION SUMMARY
09/25/2024 Letter INSPECTION SUMMARY
12/11/2024 Letter INSPECTION SUMMARY
12/12/2024 Letter INSPECTION SUMMARY
12/12/2024 Letter INSPECTION SUMMARY
12/18/2024 Letter INSPECTION SUMMARY
12/23/2024 Letter INSPECTION SUMMARY
12/27/2024 Letter INSPECTION SUMMARY
02/25/2025 Letter INSPECTION SUMMARY
03/07/2025 Letter INSPECTION SUMMARY
03/10/2025 Letter INSPECTION SUMMARY
04/21/2025 Plans Alarm plans
04/21/2025 24050258 Blackwell Apt 2-FA-set SEALED
04/28/2025 24050258 Blackwell Apt 2-FA-set SEALED RFC
04/28/2025 Letter Fire (Alarm) Plan Review Notice
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home