NEW DUPLEX
NEW DUPLEX - UNFINISHED BASEMENT - ROOF TRUSSES - UNCOVERED DECK
06/18/2024
06/27/2024
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
BRUCER@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee for New Duplex $2,930.22 $2,930.22 Paid 06/27/2024
Sanitary Sewer Development Fee $4,318.00 $4,318.00 Paid 06/27/2024
Right of Way Permit Fee $85.00 $85.00 Paid 06/27/2024
Water Tap Fee $7,520.00 $7,520.00 Paid 06/27/2024
Water Meter Fee $1,360.92 $1,360.92 Paid 06/27/2024
Residential Excise Tax Fee $1,240.32 $1,240.32 Paid 06/27/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 12/04/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 03/20/2025
Not Ready Inspection Fee $75.00 $75.00 Paid 03/20/2025
3rd and Subsequent Inspection Fee (Per Hour) $75.00 $75.00 Paid 03/20/2025
Not Ready Inspection Fee $75.00 $75.00 Paid 03/20/2025
Not Ready Inspection Fee $75.00 $75.00 Paid 03/20/2025
3rd and Subsequent Inspection Fee (Per Hour) $75.00 $75.00 Paid 03/20/2025
Not Ready Inspection Fee $75.00 $75.00 Paid 03/20/2025
Not Ready Inspection Fee $75.00 $75.00 Paid 03/20/2025
Not Ready Inspection Fee $75.00 $75.00 Paid 03/20/2025
Temporary Occupancy Fee $50.00 $50.00 Paid 03/20/2025
Temporary Occupancy Fee $50.00 $50.00 Paid 04/03/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Plot Plan Inspection Pending
Sidewalk Inspection Pending
Misc
Informational
04/04/2025
3-11-25 DP. SW was formed, aggregate was compacted and cross slopes were in compliance but conditions can change. Approved to pour. This is a duplex so covers 3719 and 3717 03-21-25 Jamie S, SW slopes are in compliance with city standards. 4-4-25 Dustin A, sw has silt built up on it .
Erosion Control Inspection Residential Pending
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
04/04/2025
4-4-25 Dustin A, silt on sw needs to be cleaned off.
Occupancy Inspection - Codes Residential Pending 5/3/2025
Misc
Corrective Action Required
03/26/2025
Unit 3717: -Sidewalk and driveway not approved -Final grade, sod, gutters, downspout, and sump pump extension -Provide sewer tracer wire port at grade -Provide bottom deck stair landing Unit 3719: -Sidewalk and driveway not approved -Final grade, sod, gutters, downspout, and sump pump extension -Provide sewer tracer wire port at grade -Provide bottom deck stair landing -Obtain lawn irrigation permit and submit backflow valve test report to city -Sidewalk and driveway not approved on record -As-graded plot plan is required -Final grade, sod, downspout and sump pump extension -Provide sewer tracer wire port at grade **TCO approved for 3717 and 3719 ***
Erosion Control Inspection Residential Partial 9/3/2024 09/03/2024
Miscellaneous Correction
Informational
09/03/2024
Full erosion control measures are in place and must be maintained until CofO
Footing Inspection - Residential Passed 9/3/2024 09/03/2024
Miscellaneous Correction
Informational
09/03/2024
Footing was passed by a third party. Exterior piers were not mentioned in the footing report
Erosion Control Inspection Residential Failed 9/11/2024 09/11/2024
Miscellaneous Correction
Resolved
09/11/2024
Full erosion control measures are in place and must be maintained until CofO
Miscellaneous Correction
Corrective Action Required
09/11/2024
Erosion control has been damaged at the front of the lot along the Southside and needs to be repaired or replaced. Full erosion control measures must be maintained until CofO
Sewer Service Inspection - R Failed 9/11/2024 09/11/2024
Miscellaneous Correction
Corrective Action Required
09/11/2024
Sewer on unit 3717 passed and is okay to cover. Unit 3719 will be scheduled at a later time This is a partial pass only
Sewer Service Inspection - R Passed 9/11/2024 09/11/2024
Miscellaneous Correction
Resolved
09/11/2024
Sewer on unit 3717 passed and is okay to cover. Unit 3719 will be scheduled at a later time This is a partial pass only
Water Service Inspection - R Passed 9/12/2024 09/12/2024
Erosion Control Inspection Residential Failed 9/16/2024 09/16/2024
Miscellaneous Correction
Resolved
09/16/2024
Erosion control has been damaged at the front of the lot along the Southside and needs to be repaired or replaced. Full erosion control measures must be maintained until CofO
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
09/16/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. Erosion control has been damaged at the front of the lot along the Southside and needs to be repaired or replaced. Gravel needs to be spread from the foundation to the street curd Full erosion control measures must be maintained until CofO
Underslab Plumbing Inspection - Residential Passed 9/19/2024 9/19/2024 09/19/2024
Erosion Control Inspection Residential Partial 9/19/2024 09/19/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
09/19/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. Erosion control has been damaged at the front of the lot along the Southside and needs to be repaired or replaced. Gravel needs to be spread from the foundation to the street curd Full erosion control measures must be maintained until CofO
Miscellaneous Correction
Informational
09/19/2024
Full erosion control measures are in place and must be maintained until CofO
Erosion Control Inspection Residential Failed 11/8/2024 11/08/2024
Miscellaneous Correction
Resolved
11/08/2024
Full erosion control measures are in place and must be maintained until CofO
Miscellaneous Correction
Corrective Action Required
11/08/2024
Replace missing or moved erosion control at the front of the lot at the street Full erosion control measures must be in place and properly maintained until CofO
All Rough Inspection - Residential Failed 11/8/2024 11/8/2024 11/08/2024
Miscellaneous Correction
Informational
11/08/2024
Garage PFH and back of duplex sheeting passed and is okay to cover This is a partial pass only
Rated Assembly Inspection Failed 11/15/2024 11/15/2024 11/15/2024
Miscellaneous Correction
Corrective Action Required
11/15/2024
3717 and 3719 SW Knoxville. Rated assembly 3717 Fire rated roof sheathing along the west side has a greater than 1/4 of an inch gap Fire rated demising wall does not extend to the roof sheathing along ridge at west side above bedroom 1 (fire rated sheathing was installed) 3719 Fire rated roof sheathing at the ridge has a greater than 1/4 of an inch gap
Gas Service Inspection - Residential Passed 11/15/2024 11/15/2024 11/15/2024
Electrical Service Inspection Failed 11/15/2024 11/15/2024 11/15/2024
Miscellaneous Correction
Corrective Action Required
11/15/2024
Both units - Electrical lines are not landed in panel - Secure all electrical above panel to code
All Rough Inspection - Residential Not Ready 11/15/2024 11/15/2024 11/15/2024
Miscellaneous Correction
Informational
11/08/2024
Garage PFH and back of duplex sheeting passed and is okay to cover This is a partial pass only
Miscellaneous Correction
Corrective Action Required
11/15/2024
- Plans are not on site at time of inspection - See electrical inspection Not ready for inspection
All Rough Inspection - Residential Failed 11/18/2024 11/18/2024 11/18/2024
Miscellaneous Correction
Informational
11/15/2024
Garage PFH and back of duplex sheeting passed and is okay to cover This is a partial pass only
Miscellaneous Correction
Resolved
11/18/2024
- Plans are not on site at time of inspection - See electrical inspection Not ready for inspection
Miscellaneous Correction
Corrective Action Required
11/18/2024
3717 and 3719 SW Knoxville. All rough 3717 Have engineers letter for garage bottom plate not being fully supported by the foundation wall and proper tie down recommendation Electrical nail guards are needed in garage at S/W and N/W corners LIB in garage S/W corner is missing nails Fire block top of chase in garage Nail missing in joist hanger at front porch Nail corner of great room to code Nail both pieces of the header to king studs throughout Secure electrical within 6 feet of attic access hatch Strap exterior wall top plate in bathroom 1 because of being over notched for plumbing Nail missing in stud shoe in bathroom 2 Electrical is still not landed in the panel Install blocking for snow flashing at gable 3719 install electrical nail guards by overhead garage door at legs Install electrical nail guard in top plate at garage N/W corner Install anchor bolts in the middle 1/3 of bottom plate in garage North wall Fire block top of chase in garage HVAC duct runs in garage ceiling needs to be supported every 10 feet on center Floor joist has been notched at the top in the garage for a 3 inch plumbing DWV by entry closet Stud shoes in PWDR is missing nails Joist hanger above kitchen island is missing a nail Nail both pieces of each header to king studs throughout Floor joist above ceiling in entry closet has been over notched for 2 in plumbing DWV Install blocking for snow flashing at gable Stud shoes in bathroom 1 are missing fasteners Strap exterior wall at top plate in bathroom 1 because of being over notched for plumbing LIB in bathroom 1 is missing nails Trap weir to vent in utility room are not to code (P3105.3) Stud shoes in bathroom 2 are missing fasteners Secure electrical within 6 feet of attic access hatch Land all electrical in panel Electrical in basement at stairwell is not completed
Electrical Service Inspection Failed 11/18/2024 11/18/2024
Miscellaneous Correction
Corrective Action Required
11/15/2024
Both units - Electrical lines are not landed in panel - Secure all electrical above panel to code
Electrical Service Inspection Failed 12/17/2024 12/17/2024 12/17/2024
Miscellaneous Correction
Corrective Action Required
11/18/2024
3717 - Secure all electrical above panel to code
Rated Assembly Inspection Not Ready 12/17/2024 12/17/2024 12/17/2024
Miscellaneous Correction
Resolved
12/17/2024
3717 and 3719 SW Knoxville. Rated assembly 3717 Fire rated roof sheathing along the west side has a greater than 1/4 of an inch gap Fire rated demising wall does not extend to the roof sheathing along ridge at west side above bedroom 1 (fire rated sheathing was installed) 3719 Fire rated roof sheathing at the ridge has a greater than 1/4 of an inch gap
Miscellaneous Correction
Corrective Action Required
12/17/2024
3717 and 3719 SW Knoxville. Rated assembly 3717 Fire rated roof sheathing along the west side has a greater than 1/4 of an inch gap Fire rated demising wall does not extend to the roof sheathing along ridge at west side above bedroom 1 (fire rated sheathing was installed) 3719 Fire rated roof sheathing at the ridge has a greater than 1/4 of an inch gap Not ready for re inspection. No improvements were made
All Rough Inspection - Residential Not Ready 12/17/2024 12/17/2024 12/17/2024
Miscellaneous Correction
Resolved
12/17/2024
Garage PFH and back of duplex sheeting passed and is okay to cover This is a partial pass only
Miscellaneous Correction
Resolved
12/17/2024
3717 and 3719 SW Knoxville. All rough 3717 Have engineers letter for garage bottom plate not being fully supported by the foundation wall and proper tie down recommendation Electrical nail guards are needed in garage at S/W and N/W corners LIB in garage S/W corner is missing nails Fire block top of chase in garage Nail missing in joist hanger at front porch Nail corner of great room to code Nail both pieces of the header to king studs throughout Secure electrical within 6 feet of attic access hatch Strap exterior wall top plate in bathroom 1 because of being over notched for plumbing Nail missing in stud shoe in bathroom 2 Electrical is still not landed in the panel Install blocking for snow flashing at gable 3719 install electrical nail guards by overhead garage door at legs Install electrical nail guard in top plate at garage N/W corner Install anchor bolts in the middle 1/3 of bottom plate in garage North wall Fire block top of chase in garage HVAC duct runs in garage ceiling needs to be supported every 10 feet on center Floor joist has been notched at the top in the garage for a 3 inch plumbing DWV by entry closet Stud shoes in PWDR is missing nails Joist hanger above kitchen island is missing a nail Nail both pieces of each header to king studs throughout Floor joist above ceiling in entry closet has been over notched for 2 in plumbing DWV Install blocking for snow flashing at gable Stud shoes in bathroom 1 are missing fasteners Strap exterior wall at top plate in bathroom 1 because of being over notched for plumbing LIB in bathroom 1 is missing nails Trap weir to vent in utility room are not to code (P3105.3) Stud shoes in bathroom 2 are missing fasteners Secure electrical within 6 feet of attic access hatch Land all electrical in panel Electrical in basement at stairwell is not completed
Miscellaneous Correction
Corrective Action Required
12/17/2024
3717 Have engineers letter for garage bottom plate not being fully supported by the foundation wall and proper tie down recommendation Electrical nail guards are needed in garage at S/W and N/W corners LIB in garage S/W corner is missing nails Fire block top of chase in garage Nail missing in joist hanger at front porch Nail corner of great room to code Nail both pieces of the header to king studs throughout Secure electrical within 6 feet of attic access hatch Strap exterior wall top plate in bathroom 1 because of being over notched for plumbing Nail missing in stud shoe in bathroom 2 Electrical is still not landed in the panel Install blocking for snow flashing at gable 3719 install electrical nail guards by overhead garage door at legs Install electrical nail guard in top plate at garage N/W corner HVAC duct runs in garage ceiling needs to be supported every 10 feet on center is now covered with insulation) Floor joist has been notched at the top in the garage for a 3 inch plumbing DWV by entry closet (is now covered with insulation) Stud shoes in PWDR is missing nails Joist hanger above kitchen island is missing a nail Nail both pieces of each header to king studs throughout Floor joist above ceiling in entry closet has been over notched for 2 in plumbing DWV Install blocking for snow flashing at gable Stud shoes in bathroom 1 are missing fasteners Strap exterior wall at top plate in bathroom 1 because of being over notched for plumbing LIB in bathroom 1 is missing nails Trap weir to vent in utility room are not to code (P3105.3) Stud shoes in bathroom 2 are missing fasteners Secure electrical within 6 feet of attic access hatch Land all electrical in panel Electrical in basement at stairwell is not completed Remove all insulation in areas that needs to be inspected All rough re inspection is not ready because some areas are covered with insulation Remove insulation in areas to be inspected Not ready fee added
Electrical Service Inspection Passed 12/23/2024 12/23/2024
Miscellaneous Correction
Resolved
12/23/2024
3717 - Secure all electrical above panel to code
Rated Assembly Inspection Failed 12/23/2024 12/23/2024
Miscellaneous Correction
Resolved
12/23/2024
3717 and 3719 SW Knoxville. Rated assembly 3717 Fire rated roof sheathing along the west side has a greater than 1/4 of an inch gap Fire rated demising wall does not extend to the roof sheathing along ridge at west side above bedroom 1 (fire rated sheathing was installed) 3719 Fire rated roof sheathing at the ridge has a greater than 1/4 of an inch gap Not ready for re inspection. No improvements were made
Miscellaneous Correction
Corrective Action Required
12/23/2024
3717 and 3719 SW Knoxville. Rated assembly 3717 Fire rated roof sheathing along the west side has a greater than 1/4 of an inch gap Fire rated demising wall does not extend to the roof sheathing along ridge at west side above bedroom 1 (fire rated sheathing was installed) 3719 Fire rated roof sheathing at the ridge has a greater than 1/4 of an inch gap Not ready for re inspection. No improvements were made Still no improvements were made 12/23/24. KBEARD
All Rough Inspection - Residential Failed 12/23/2024 12/23/2024 12/23/2024
Miscellaneous Correction
Resolved
12/23/2024
3717 Have engineers letter for garage bottom plate not being fully supported by the foundation wall and proper tie down recommendation Electrical nail guards are needed in garage at S/W and N/W corners LIB in garage S/W corner is missing nails Fire block top of chase in garage Nail missing in joist hanger at front porch Nail corner of great room to code Nail both pieces of the header to king studs throughout Secure electrical within 6 feet of attic access hatch Strap exterior wall top plate in bathroom 1 because of being over notched for plumbing Nail missing in stud shoe in bathroom 2 Electrical is still not landed in the panel Install blocking for snow flashing at gable 3719 install electrical nail guards by overhead garage door at legs Install electrical nail guard in top plate at garage N/W corner HVAC duct runs in garage ceiling needs to be supported every 10 feet on center is now covered with insulation) Floor joist has been notched at the top in the garage for a 3 inch plumbing DWV by entry closet (is now covered with insulation) Stud shoes in PWDR is missing nails Joist hanger above kitchen island is missing a nail Nail both pieces of each header to king studs throughout Floor joist above ceiling in entry closet has been over notched for 2 in plumbing DWV Install blocking for snow flashing at gable Stud shoes in bathroom 1 are missing fasteners Strap exterior wall at top plate in bathroom 1 because of being over notched for plumbing LIB in bathroom 1 is missing nails Trap weir to vent in utility room are not to code (P3105.3) Stud shoes in bathroom 2 are missing fasteners Secure electrical within 6 feet of attic access hatch Land all electrical in panel Electrical in basement at stairwell is not completed Remove all insulation in areas that needs to be inspected All rough re inspection is not ready because some areas are covered with insulation Remove insulation in areas to be inspected Not ready fee added
Miscellaneous Correction
Corrective Action Required
12/23/2024
3717 and 3719 SW Knoxville. All rough 3717 Have engineers letter for garage bottom plate not being fully supported by the foundation wall and proper tie down recommendation Electrical nail guards are needed in garage at S/W and N/W corners Protect electrical within 6 feet of attic access hatch Secure electrical service cable above panel to code 3719 install electrical nail guards by overhead garage door at legs Install electrical nail guard in top plate at garage N/W corner Nail both pieces of each header to king studs throughout Floor joist above ceiling in entry closet has been over notched for 2 in plumbing DWV Trap weir to vent in utility room are not to code (P3105.3) Protect electrical within 6 feet of attic access hatch
Rated Assembly Inspection Not Ready 12/27/2024 12/27/2024 12/27/2024
Miscellaneous Correction
Corrective Action Required
12/23/2024
3717 and 3719 SW Knoxville. Rated assembly 3717 Fire rated roof sheathing along the west side has a greater than 1/4 of an inch gap Fire rated demising wall does not extend to the roof sheathing along ridge at west side above bedroom 1 (fire rated sheathing was installed) 3719 Fire rated roof sheathing at the ridge has a greater than 1/4 of an inch gap Not ready for re inspection. No improvements were made Still no improvements were made 12/23/24. KBEARD No improvements were made. Not ready 12/28/2024. KBEARD
All Rough Inspection - Residential Not Ready 12/27/2024 12/27/2024 12/27/2024
Miscellaneous Correction
Resolved
12/27/2024
3717 and 3719 SW Knoxville. All rough 3717 Have engineers letter for garage bottom plate not being fully supported by the foundation wall and proper tie down recommendation Electrical nail guards are needed in garage at S/W and N/W corners Protect electrical within 6 feet of attic access hatch Secure electrical service cable above panel to code 3719 install electrical nail guards by overhead garage door at legs Install electrical nail guard in top plate at garage N/W corner Nail both pieces of each header to king studs throughout Floor joist above ceiling in entry closet has been over notched for 2 in plumbing DWV Trap weir to vent in utility room are not to code (P3105.3) Protect electrical within 6 feet of attic access hatch
Miscellaneous Correction
Corrective Action Required
12/27/2024
3717 and 3719 SW Knoxville. 3717 Have engineers letter for garage bottom plate not being fully supported by the foundation wall and proper tie down recommendation (see engineers report on size of all thread bolt into concrete stem wall) Secure electrical service cable above panel to code 3719 Install electrical nail guard in top plate at garage N/W corner Floor joist above ceiling in entry closet has been over notched for 2 in plumbing DWV Trap weir to vent in utility room are not to code (P3105.3) Protect electrical within 6 feet of attic access hatch
Rated Assembly Inspection Passed 12/31/2024 12/31/2024 12/31/2024
Miscellaneous Correction
Corrective Action Required
12/27/2024
3717 and 3719 SW Knoxville. Rated assembly 3717 Fire rated demising wall does not extend to the roof sheathing along ridge at west side above bedroom 1 (fire rated sheathing was installed) 3719 Fire rated roof sheathing at the ridge has a greater than 1/4 of an inch gap Not ready for re inspection. No improvements were made Still no improvements were made 12/23/24. KBEARD No improvements were made. Not ready 12/28/2024. KBEARD
All Rough Inspection - Residential Failed 12/31/2024 12/31/2024 12/31/2024
Miscellaneous Correction
Resolved
12/31/2024
3717 and 3719 SW Knoxville. 3717 Have engineers letter for garage bottom plate not being fully supported by the foundation wall and proper tie down recommendation (see engineers report on size of all thread bolt into concrete stem wall) Secure electrical service cable above panel to code 3719 Install electrical nail guard in top plate at garage N/W corner Floor joist above ceiling in entry closet has been over notched for 2 in plumbing DWV Trap weir to vent in utility room are not to code (P3105.3) Protect electrical within 6 feet of attic access hatch
Miscellaneous Correction
Corrective Action Required
12/31/2024
3717 Have engineers letter for garage bottom plate not being fully supported by the foundation wall and proper tie down recommendation (see engineers report on size of all thread bolt into concrete stem wall) Newly installed 5/8 inch anchor bolts have broken out the foundation wall. Have engineers report on a repair 3719 Floor joist above ceiling by entry closet in garage raceway has been over notched for 2 in plumbing DWV (have engineers report off a repair) Trap weir to vent in utility room are not to code (P3105.3)
All Rough Inspection - Residential Passed 1/17/2025 1/17/2025 01/17/2025
Miscellaneous Correction
Corrective Action Required
12/31/2024
3717 Have engineers letter for garage bottom plate not being fully supported by the foundation wall and proper tie down recommendation (see engineers report on size of all thread bolt into concrete stem wall) Newly installed 5/8 inch anchor bolts have broken out the foundation wall. Have engineers report on a repair 3719 Floor joist above ceiling by entry closet in garage raceway has been over notched for 2 in plumbing DWV (have engineers report off a repair) Trap weir to vent in utility room are not to code (P3105.3)
Rated Assembly Inspection Passed 1/28/2025 1/28/2025 01/28/2025
Driveway Inspection Partial 3/11/2025 3/11/2025 03/11/2025
Misc
Informational
03/11/2025
3-11-25 DP. DW Was formed, aggregate compacted, Approved to pour. This is a duplex so good for 3719 and 3717
Sidewalk Inspection Partial 3/11/2025 3/11/2025 03/11/2025
Misc
Informational
03/11/2025
3-11-25 DP. SW was formed, aggregate was compacted and cross slopes were in compliance but conditions can change. Approved to pour. This is a duplex so covers 3719 and 3717
Piers/Caissons Inspection - Residential Not Ready 3/11/2025 03/11/2025
Misc
Corrective Action Required
03/11/2025
Piers incorrect size No rebar
Occupancy Inspection - Codes Residential Not Ready 3/12/2025 3/12/2025 03/12/2025
Misc
Corrective Action Required
03/12/2025
Not a complete list. Inspection denied. -address pending driveway sidewalk and pier inspection -missing guard rail at front stoop -deck not completed -erosion control not in compliance
Piers/Caissons Inspection - Residential Not Ready 3/12/2025 3/12/2025 03/12/2025
Misc
Corrective Action Required
03/11/2025
Still incorrect Piers incorrect size No rebar
Piers/Caissons Inspection - Residential Passed 3/12/2025 3/12/2025 03/12/2025
Misc
Resolved
03/12/2025
Still incorrect Piers incorrect size No rebar
Erosion Control Inspection Residential Passed 03/14/2025
Miscellaneous Correction
Resolved
03/14/2025
Replace missing or moved erosion control at the front of the lot at the street Full erosion control measures must be in place and properly maintained until CofO
Occupancy Inspection - Codes Residential Failed 3/14/2025 3/14/2025 03/14/2025
Misc
Corrective Action Required
03/12/2025
**Please have electrician contact me. Khanh.nguyen@cityofls.net Unit 3717 only: -Sidewalk and driveway not approved -Final grade, sod, gutters, downspout, and sump pump extension -Provide sewer tracer wire port at grade -Deck: install middle support pier and post or install deck beam sized per plan. Plan calls for (3)2x12; provide bottom stair landing; attach deck beam to each post with two 1/2” through bolts/washers/nuts or equivalent connections -Install garage luminaires -Garage door not self-closing -Install a 3” screw through a pre-drillled screw hole adjacent to the dead bolt security strike plate -Fire caulk penetrations of fire-rated wall under bathroom sinks -Remove all foundation wall metal ties -Install basement ceiling light above stair landing -Provide breaker lock for out-of-sight water heater
Occupancy Inspection - Codes Residential Failed 3/17/2025 3/17/2025 03/17/2025
Misc
Corrective Action Required
03/14/2025
Unit 3717 only: -Sidewalk and driveway not approved -Final grade, sod, gutters, downspout, and sump pump extension -Provide sewer tracer wire port at grade - Label address on outside power disconnect - No landing for deck stairs -Deck: install middle support pier and post or install deck beam sized per plan. Plan calls for (3)2x12; provide bottom stair landing; attach deck beam to each post with two 1/2” through bolts/washers/nuts or equivalent connections -Fire caulk penetrations of fire-rated wall under bathroom sinks
Occupancy Inspection - Codes Residential Failed 3/19/2025 3/19/2025 03/19/2025
Misc
Corrective Action Required
03/17/2025
Unit 3717 only: -Sidewalk and driveway not approved -Final grade, sod, gutters, downspout, and sump pump extension -Provide sewer tracer wire port at grade - Label address on outside power disconnect - No landing for deck landing
Occupancy Inspection - Codes Residential Ready for Temp CO 03/20/2025
Misc
Corrective Action Required
03/19/2025
Unit 3717 only: -Sidewalk and driveway not approved -Final grade, sod, gutters, downspout, and sump pump extension -Provide sewer tracer wire port at grade - Label address on outside power disconnect - No landing for deck landing
Driveway Inspection Partial 3/21/2025 3/21/2025 03/21/2025
Misc
Informational
03/11/2025
3-11-25 DP. DW Was formed, aggregate compacted, Approved to pour. This is a duplex so good for 3719 and 3717 03-21-25 Jamie S, DW slopes are in compliance with city standards.
Sidewalk Inspection Partial 3/21/2025 3/21/2025 03/21/2025
Misc
Informational
03/11/2025
3-11-25 DP. SW was formed, aggregate was compacted and cross slopes were in compliance but conditions can change. Approved to pour. This is a duplex so covers 3719 and 3717 03-21-25 Jamie S, SW slopes are in compliance with city standards.
Occupancy Inspection - Codes Residential Failed 3/24/2025 3/24/2025 03/24/2025
Misc
Corrective Action Required
03/20/2025
Unit 3717: -Sidewalk and driveway not approved -Final grade, sod, gutters, downspout, and sump pump extension -Provide sewer tracer wire port at grade -Provide bottom deck stair landing Unit 3719: -Sidewalk and driveway not approved -Final grade, sod, gutters, downspout, and sump pump extension -Provide sewer tracer wire port at grade -Provide bottom deck stair landing -Obtain lawn irrigation permit and submit backflow valve test report to city -Sidewalk and driveway not approved on record -As-graded plot plan is required -Final grade, sod, downspout and sump pump extension -Seal exterior wall penetrations; seal above meter, AC disconnect, seal exterior lights, etc -Provide sewer tracer wire port at grade -Front stoop receptacle not gfci-protected -Provide security strike plate for entry door per security code; screw the embedded metal jamb brace into studs through the 4 pre-drilled holes with min 3” screws -Half bathroom fan not working -Cut off excess ufer rebar **TCO approved for 3717 only**
Occupancy Inspection - Codes Residential Ready for Temp CO 3/26/2025 3/26/2025 03/26/2025
Misc
Corrective Action Required
03/24/2025
Unit 3717: -Sidewalk and driveway not approved -Final grade, sod, gutters, downspout, and sump pump extension -Provide sewer tracer wire port at grade -Provide bottom deck stair landing Unit 3719: -Sidewalk and driveway not approved -Final grade, sod, gutters, downspout, and sump pump extension -Provide sewer tracer wire port at grade -Provide bottom deck stair landing -Obtain lawn irrigation permit and submit backflow valve test report to city -Sidewalk and driveway not approved on record -As-graded plot plan is required -Final grade, sod, downspout and sump pump extension -Provide sewer tracer wire port at grade **TCO approved for 3717 and 3719 ***
Driveway Inspection Passed 4/4/2025 4/4/2025 04/04/2025
Misc
Informational
03/21/2025
3-11-25 DP. DW Was formed, aggregate compacted, Approved to pour. This is a duplex so good for 3719 and 3717 03-21-25 Jamie S, DW slopes are in compliance with city standards. 4-4-25 Dustin A, passed
Sidewalk Inspection Failed 4/4/2025 4/4/2025 04/04/2025
Misc
Informational
03/21/2025
3-11-25 DP. SW was formed, aggregate was compacted and cross slopes were in compliance but conditions can change. Approved to pour. This is a duplex so covers 3719 and 3717 03-21-25 Jamie S, SW slopes are in compliance with city standards. 4-4-25 Dustin A, sw has silt built up on it .
Erosion Control Inspection Residential Failed 4/4/2025 4/4/2025 04/04/2025
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
04/04/2025
4-4-25 Dustin A, silt on sw needs to be cleaned off.
Documents & Images
Date Uploaded File Type Document Name
06/18/2024 OS #86 - ENGINEERED PLANS
06/18/2024 OS #86 - PERMIT APP
06/18/2024 OS #86 - PLOT PLAN
06/18/2024 OS #86 - TRUSS DETAILS
06/18/2024 OS #86 - TRUSS LAYOUT
06/27/2024 Approved Plans APPROVED PLANS
06/27/2024 Plot Plan APPROVED PLOT PLAN
06/27/2024 Approved Plans APPROVED TRUSS LAYOUT
06/27/2024 Approved Plans APPROVED TRUSS PACKAGE
06/27/2024 Permit Codes Residential Plan Review
06/27/2024 Permit DS Building Permit
06/27/2024 Receipt Receipt for transaction:2024-005281
09/02/2024 M L Crose 3717 & 3719 Knoxville Ct LSMO Osage Lot 86 3rd Party Footing Inspection Report 8-30-24
09/03/2024 Letter INSPECTION SUMMARY
09/03/2024 Letter INSPECTION SUMMARY
09/11/2024 Letter INSPECTION SUMMARY
09/11/2024 Letter DS Building Permit
09/11/2024 Letter INSPECTION SUMMARY
09/11/2024 Letter INSPECTION SUMMARY
09/12/2024 Letter INSPECTION SUMMARY
09/16/2024 Letter INSPECTION SUMMARY
09/19/2024 Letter INSPECTION SUMMARY
09/19/2024 Letter INSPECTION SUMMARY
11/08/2024 Letter INSPECTION SUMMARY
11/08/2024 Letter INSPECTION SUMMARY
11/15/2024 Letter INSPECTION SUMMARY
11/15/2024 Letter INSPECTION SUMMARY
11/15/2024 Letter INSPECTION SUMMARY
11/15/2024 Letter INSPECTION SUMMARY
11/18/2024 Letter INSPECTION SUMMARY
11/18/2024 Letter INSPECTION SUMMARY
11/20/2024 Engineer Report/Study ENGINEER LETTER
12/04/2024 Receipt Receipt for transaction:2024-009334
12/17/2024 Letter INSPECTION SUMMARY
12/17/2024 Letter INSPECTION SUMMARY
12/17/2024 Letter INSPECTION SUMMARY
12/23/2024 Letter INSPECTION SUMMARY
12/23/2024 Letter INSPECTION SUMMARY
12/23/2024 Letter INSPECTION SUMMARY
12/23/2024 Engineer Report/Study 86 Osage Field Issue- Letter Update
12/27/2024 Letter INSPECTION SUMMARY
12/27/2024 Letter INSPECTION SUMMARY
12/31/2024 Letter INSPECTION SUMMARY
12/31/2024 Letter INSPECTION SUMMARY
01/02/2025 86 Osage- Overnotched joist- Signed
01/16/2025 86 Osage- Overnotched joist + Anchor bolt
01/17/2025 Letter INSPECTION SUMMARY
01/28/2025 Letter INSPECTION SUMMARY
03/11/2025 Letter INSPECTION SUMMARY
03/11/2025 Letter INSPECTION SUMMARY
03/11/2025 Letter INSPECTION SUMMARY
03/12/2025 Letter INSPECTION SUMMARY
03/12/2025 Letter INSPECTION SUMMARY
03/14/2025 Letter INSPECTION SUMMARY
03/14/2025 Letter INSPECTION SUMMARY
03/17/2025 Letter INSPECTION SUMMARY
03/19/2025 Letter INSPECTION SUMMARY
03/19/2025 Letter INSPECTION SUMMARY
03/20/2025 Letter INSPECTION SUMMARY
03/20/2025 Certificate/License Codes Temporary Certificate of Occupancy
03/20/2025 Receipt Receipt for transaction:2025-001684
03/21/2025 Letter INSPECTION SUMMARY
03/21/2025 Letter INSPECTION SUMMARY
03/24/2025 Letter INSPECTION SUMMARY
03/26/2025 Letter INSPECTION SUMMARY
04/03/2025 Certificate/License Codes Temporary Certificate of Occupancy
04/03/2025 Receipt Receipt for transaction:2025-002013
04/04/2025 Letter INSPECTION SUMMARY
04/04/2025 Letter INSPECTION SUMMARY
04/04/2025 Letter INSPECTION SUMMARY
04/04/2025 Letter INSPECTION SUMMARY
04/24/2025 OS #86 - TCO Extension 4_24_25
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home