Summary
PRRES20242080
Building Permit - Residential
Certificate of Occupancy
NEW DUPLEX
NEW DUPLEX - ROOF TRUSSES - UNCOVERED DECKS -
04/25/2024
05/02/2024
10/26/2024
06/18/2025
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
BRUCER@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee for New Duplex $2,930.22 $2,930.22 Paid 05/02/2024
Sanitary Sewer Development Fee $4,318.00 $4,318.00 Paid 05/02/2024
Right of Way Permit Fee $85.00 $85.00 Paid 05/02/2024
Residential Excise Tax Fee $1,240.32 $1,240.32 Paid 05/02/2024
Water Tap Fee $7,520.00 $7,520.00 Paid 05/02/2024
Water Meter Fee $1,360.92 $1,360.92 Paid 05/02/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 11/22/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 12/17/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 12/17/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 12/20/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 01/13/2025
Temporary Occupancy Fee $50.00 $50.00 Paid 02/05/2025
Temporary Occupancy Fee $50.00 $50.00 Paid 05/01/2025
Temporary Occupancy Fee $50.00 $50.00 Paid 05/28/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Partial 5/14/2024 05/14/2024
Miscellaneous Correction
Resolved
05/14/2024
Straw waddle is missing along the front north side of lot at the street Full erosion control must be maintained until CofO
Footing Inspection - Residential Passed 5/14/2024 05/14/2024
Miscellaneous Correction
Informational
05/14/2024
Footing passed by a third party. Exterior piers were not mentioned in the footing report
Sewer Service Inspection - R Passed 5/22/2024 05/22/2024
Water Service Inspection - R Passed 5/23/2024 (10:00) 5/23/2024 05/23/2024
Erosion Control Inspection Residential Partial 5/31/2024 05/31/2024
Miscellaneous Correction
Resolved
05/31/2024
Straw waddle is missing along the front north side of lot at the street Full erosion control must be maintained until CofO
Miscellaneous Correction
Informational
05/31/2024
Erosion control is in place and must be maintained until CofO
Underslab Plumbing Inspection - Residential Passed 5/31/2024 5/31/2024 05/31/2024
All Rough Inspection - Residential Failed 7/19/2024 7/19/2024 07/19/2024
Miscellaneous Correction
Corrective Action Required
07/19/2024
3723 -5/8 inch anchor bolts are not completed -Front porch soffit is covered without inspection for truss tie down screws 3725 -Tension hold down straps are not nailed off -Front porch soffit is covered without inspection for truss tie down screws
Erosion Control Inspection Residential Partial 7/19/2024 07/19/2024
Miscellaneous Correction
Resolved
07/19/2024
Erosion control is in place and must be maintained until CofO
Miscellaneous Correction
Informational
07/19/2024
Erosion control is in place and must be maintained until CofO
All Rough Inspection - Residential Failed 7/25/2024 7/25/2024 07/25/2024
Miscellaneous Correction
Resolved
07/25/2024
3723 -5/8 inch anchor bolts are not completed -Front porch soffit is covered without inspection for truss tie down screws 3725 -Tension hold down straps are not nailed off -Front porch soffit is covered without inspection for truss tie down screws
Miscellaneous Correction
Informational
07/25/2024
Builder scheduled all rough and only wanted garage exterior sheeting inspection Exterior garage sheeting portal inspection passed and is okay to cover This is a partial inspection only
Electrical Service Inspection Passed 8/28/2024 08/28/2024
Gas Service Inspection - Residential Passed 8/28/2024 08/28/2024
Rated Assembly Inspection Failed 8/28/2024 08/28/2024
Miscellaneous Correction
Corrective Action Required
08/28/2024
3723 and 3725 SW Knoxville rated assembly 3723 -Fire block Ibeam at demising wall in basement -Roof sheeting has a vent cut out in it within 4 feet of demising wall -Gaps in roof sheeting exceeds 1/4 of an inch -Remove wood wedges along the demising wall 3725 -Fire block Ibeam at demising wall in basement -Roof sheeting has a vent cut out in it within 4 feet of demising wall -Remove wood wedges along the demising wall
All Rough Inspection - Residential Failed 8/28/2024 8/28/2024 08/28/2024
Miscellaneous Correction
Resolved
08/28/2024
Builder scheduled all rough and only wanted garage exterior sheeting inspection Exterior garage sheeting portal inspection passed and is okay to cover This is a partial inspection only
Miscellaneous Correction
Corrective Action Required
08/28/2024
3723 SW Knoxville. All rough 3725 Garage anchor bolts needs to be between 4 to 12 inches from the edge of the sole plate Electrical 14/2 wire in powder bathroom for light fixture is outside the stud cavity LSTRA strap in missing at the entry window Fire block top of HVAC chase in kitchen at upper plywood floor LSTRA missing in bedroom 1 BOCA plate missing for mechanical in bedroom 1/utility room Seal mechanical at 45degree joint in utility room Uploaded truss repair in bedroom 3 Not all 3 2x10’s in basement at stairwell are supported by the 2x4 wall Fire block all air vents in basement at upper floor Fire block between foundation demising wall at Ibeam 3723 Address full sole plate not resting on garage South side foundation wall Garage anchor bolts needs to be placed within 4-12 inches of the ends of sole plates Nail is missing in joist hanger in kitchen/great room 3 feet from exterior wall Fire block top of HVAC chase to upper floor in kitchen LSTRA strap in entry window is not installed Nail front interior entry corner and great room corner to code Fire block top plate in corner of great room Upload truss repair for bedroom 3 Nail exterior corner of bedroom 2 to code Nail S/W corner of bedroom 1 to code LSTRA in not installed in bedroom 1 Nail all corners to code Triple 2x10 in basement at stairwell is not fully supported by the 2x4 wall under it Fire block at Ibeam in basement at demising wall One 14/2 electrical wire in basement needs to be supported by Ibeam
Rated Assembly Inspection Failed 9/10/2024 09/10/2024
Miscellaneous Correction
Resolved
09/10/2024
3723 and 3725 SW Knoxville rated assembly 3723 -Fire block Ibeam at demising wall in basement -Roof sheeting has a vent cut out in it within 4 feet of demising wall -Gaps in roof sheeting exceeds 1/4 of an inch -Remove wood wedges along the demising wall 3725 -Fire block Ibeam at demising wall in basement -Roof sheeting has a vent cut out in it within 4 feet of demising wall -Remove wood wedges along the demising wall
Miscellaneous Correction
Corrective Action Required
09/10/2024
3723 and 3725 SW Knoxville rated assembly (2) 3723 -Fire block Ibeam at demising wall in basement (provide information on sealant used) -Roof sheeting has a vent cut out in it within 4 feet of demising wall -Gaps in roof sheeting exceeds 1/4 of an inch -Remove wood wedges along the demising wall 3725 -Fire block Ibeam at demising wall in basement (provided information on sealant used) -Roof sheeting has a vent cut out in it within 4 feet of demising wall -Remove wood wedges along the demising wall No improvements were made since last inspection (WALK YOUR PROPERTY) before scheduling your inspection
Erosion Control Inspection Residential Failed 9/10/2024 09/10/2024
Miscellaneous Correction
Resolved
09/10/2024
Erosion control is in place and must be maintained until CofO
Miscellaneous Correction
Corrective Action Required
09/10/2024
Damaged erosion control at the front of the property at the street needs to be repaired or replaced Erosion control is in place and must be maintained until CofO
All Rough Inspection - Residential Failed 9/10/2024 9/10/2024 09/10/2024
Miscellaneous Correction
Resolved
09/10/2024
3723 SW Knoxville. All rough 3725 Garage anchor bolts needs to be between 4 to 12 inches from the edge of the sole plate Electrical 14/2 wire in powder bathroom for light fixture is outside the stud cavity LSTRA strap in missing at the entry window Fire block top of HVAC chase in kitchen at upper plywood floor LSTRA missing in bedroom 1 BOCA plate missing for mechanical in bedroom 1/utility room Seal mechanical at 45degree joint in utility room Uploaded truss repair in bedroom 3 Not all 3 2x10’s in basement at stairwell are supported by the 2x4 wall Fire block all air vents in basement at upper floor Fire block between foundation demising wall at Ibeam 3723 Address full sole plate not resting on garage South side foundation wall Garage anchor bolts needs to be placed within 4-12 inches of the ends of sole plates Nail is missing in joist hanger in kitchen/great room 3 feet from exterior wall Fire block top of HVAC chase to upper floor in kitchen LSTRA strap in entry window is not installed Nail front interior entry corner and great room corner to code Fire block top plate in corner of great room Upload truss repair for bedroom 3 Nail exterior corner of bedroom 2 to code Nail S/W corner of bedroom 1 to code LSTRA in not installed in bedroom 1 Nail all corners to code Triple 2x10 in basement at stairwell is not fully supported by the 2x4 wall under it Fire block at Ibeam in basement at demising wall One 14/2 electrical wire in basement needs to be supported by Ibeam
Miscellaneous Correction
Corrective Action Required
09/10/2024
3723 and 3725 SW Knoxville all rough (2) 3725 Garage anchor bolts needs to be between 4 to 12 inches from the edge of the sole plate (sheet rock is blocking inspection) LSTRA strap in missing at the entry window (still not installed) Fire block top of HVAC chase in kitchen at upper plywood floor (can not be accessed because of sheet rock) Seal mechanical at 45degree joint in utility room. (Still not completed) Fire block all air vents in basement at upper floor (still no improvements) Fire block between foundation demising wall at Ibeam (new product information used) 3723 Address full sole plate not resting on garage South side foundation wall ( access is block by sheet rock) Garage anchor bolts needs to be placed within 4-12 inches of the ends of sole plates (access is block by sheet rock) Fire block top of HVAC chase to upper floor in kitchen (access is blocked by sheet rock) LSTRA strap in entry window is not installed (still not installed) Fire block at Ibeam in basement at demising wall (supply information on product used)
All Rough Inspection - Residential Passed 9/12/2024 9/12/2024 09/12/2024
Miscellaneous Correction
Resolved
09/12/2024
3723 and 3725 SW Knoxville all rough (2) 3725 Garage anchor bolts needs to be between 4 to 12 inches from the edge of the sole plate (sheet rock is blocking inspection) LSTRA strap in missing at the entry window (still not installed) Fire block top of HVAC chase in kitchen at upper plywood floor (can not be accessed because of sheet rock) Seal mechanical at 45degree joint in utility room. (Still not completed) Fire block all air vents in basement at upper floor (still no improvements) Fire block between foundation demising wall at Ibeam (new product information used) 3723 Address full sole plate not resting on garage South side foundation wall ( access is block by sheet rock) Garage anchor bolts needs to be placed within 4-12 inches of the ends of sole plates (access is block by sheet rock) Fire block top of HVAC chase to upper floor in kitchen (access is blocked by sheet rock) LSTRA strap in entry window is not installed (still not installed) Fire block at Ibeam in basement at demising wall (supply information on product used)
Rated Assembly Inspection Failed 9/19/2024 9/19/2024 09/19/2024
Miscellaneous Correction
Corrective Action Required
09/10/2024
3723 and 3725 SW Knoxville rated assembly (2) 3723 -Fire block Ibeam at demising wall in basement (provide information on sealant used) -Roof sheeting has a vent cut out in it within 4 feet of demising wall -Gaps in roof sheeting exceeds 1/4 of an inch -Remove wood wedges along the demising wall 3725 -Fire block Ibeam at demising wall in basement (provided information on sealant used) -Roof sheeting has a vent cut out in it within 4 feet of demising wall -Remove wood wedges along the demising wall No improvements were made since last inspection (WALK YOUR PROPERTY) before scheduling your inspection Screw pattern inspection can not be preformed until these items list above have passed KBEARD 9:45am
Erosion Control Inspection Residential Partial 9/19/2024 09/19/2024
Miscellaneous Correction
Resolved
09/19/2024
Damaged erosion control at the front of the property at the street needs to be repaired or replaced Erosion control is in place and must be maintained until CofO
Miscellaneous Correction
Informational
09/19/2024
Erosion control is in place and must be maintained until CofO
Driveway Inspection Partial 9/20/2024 9/20/2024 09/20/2024
Misc
Informational
09/20/2024
9-20-24 Dustin A, Dw is formed and compacted. Depth is in compliance . Will need to maintain ada compliance . Approved to pour.
Sidewalk Inspection Partial 9/20/2024 9/20/2024 09/20/2024
Misc
Informational
09/20/2024
9-20-24 Dustin A, Sw is formed and compacted and slopes are in compliance. Approved to pour .
Driveway Inspection Passed 9/27/2024 9/27/2024 09/25/2024
Misc
Informational
09/20/2024
9-20-24 Dustin A, Dw is formed and compacted. Depth is in compliance . Will need to maintain ada compliance . Approved to pour. 9-25-24 Dustin A, DW is poured to city specs and slopes are in compliance. Passed
Sidewalk Inspection Failed 9/27/2024 9/27/2024 09/25/2024
Misc
Informational
09/20/2024
9-20-24 Dustin A, Sw is formed and compacted and slopes are in compliance. Approved to pour . 9-25-24 Dustin A, SW is poured. Slopes are in compliance. There is a trip hazard on the south side where it attaches to a existing that will need to be fixed as well as the sw is seperating .
Rated Assembly Inspection Passed 10/4/2024 10/4/2024 10/04/2024
Miscellaneous Correction
Resolved
10/04/2024
3723 and 3725 SW Knoxville rated assembly (2) 3723 -Fire block Ibeam at demising wall in basement (provide information on sealant used) -Roof sheeting has a vent cut out in it within 4 feet of demising wall -Gaps in roof sheeting exceeds 1/4 of an inch -Remove wood wedges along the demising wall 3725 -Fire block Ibeam at demising wall in basement (provided information on sealant used) -Roof sheeting has a vent cut out in it within 4 feet of demising wall -Remove wood wedges along the demising wall No improvements were made since last inspection (WALK YOUR PROPERTY) before scheduling your inspection Screw pattern inspection can not be preformed until these items list above have passed KBEARD 9:45am
Erosion Control Inspection Residential Failed 10/4/2024 10/04/2024
Miscellaneous Correction
Resolved
10/04/2024
Erosion control is in place and must be maintained until CofO
Miscellaneous Correction
Corrective Action Required
10/04/2024
Some erosion control at the front of the lot is damaged and no longer serves its intended purpose Clean lot up from trash debris
Piers/Caissons Inspection - Residential Failed 10/31/2024 10/31/2024 10/31/2024
Miscellaneous Correction
Informational
10/31/2024
3725 passed only This is a partial pass only
Piers/Caissons Inspection - Residential Passed 11/1/2024 11/1/2024 11/01/2024
Miscellaneous Correction
Resolved
11/01/2024
3725 passed only This is a partial pass only
Erosion Control Inspection Residential Partial 11/19/2024 11/19/2024
Miscellaneous Correction
Resolved
11/19/2024
Some erosion control at the front of the lot is damaged and no longer serves its intended purpose Clean lot up from trash debris
Miscellaneous Correction
Informational
11/19/2024
Erosion control is in place and must be properly maintained until CofO
Occupancy Inspection - Codes Residential Failed 11/19/2024 11/19/2024 11/19/2024
Miscellaneous Correction
Informational
11/19/2024
Builder canceled inspection as I was walking up to the property. No inspection was done
Occupancy Inspection - Codes Residential Failed 11/20/2024 11/20/2024 11/20/2024
Miscellaneous Correction
Resolved
11/20/2024
Builder canceled inspection as I was walking up to the property. No inspection was done
Miscellaneous Correction
Corrective Action Required
11/20/2024
3725 SW Knoxville only First riser going upstairs from the main living area has a height greater than the code allowance of 7 3/4 of an inch Fire block gaps in the garage above the overhead door and around the bottom areas of the chases Install lock out at electrical panel for HWT A/C whip at the exterior condenser is not not hooked up Back deck stairway landing pad is not installed Back deck is missing a joist hanger at the corner of rim board and ledger Sod, splash pads, gutters and sump pump extension are not installed As graded plot plan is required before sodding Sidewalk inspection must pass
Erosion Control Inspection Residential Partial 11/20/2024 11/20/2024
Miscellaneous Correction
Informational
11/19/2024
Erosion control is in place and must be properly maintained until CofO
Plot Plan Inspection Failed 11/20/2024 11/20/2024
Miscellaneous Correction
Corrective Action Required
11/20/2024
As graded plot plan is required before sodding
Sidewalk Inspection Passed 11/20/2024
Misc
Informational
09/25/2024
9-20-24 Dustin A, Sw is formed and compacted and slopes are in compliance. Approved to pour . 9-25-24 Dustin A, SW is poured. Slopes are in compliance. There is a trip hazard on the south side where it attaches to a existing that will need to be fixed as well as the sw is seperating . 11-20-24 Dustin A, corrected passed
Occupancy Inspection - Codes Residential Ready for Temp CO 11/22/2024 11/22/2024 11/22/2024
Miscellaneous Correction
Resolved
11/22/2024
3725 SW Knoxville only First riser going upstairs from the main living area has a height greater than the code allowance of 7 3/4 of an inch Fire block gaps in the garage above the overhead door and around the bottom areas of the chases Install lock out at electrical panel for HWT A/C whip at the exterior condenser is not not hooked up Back deck stairway landing pad is not installed Back deck is missing a joist hanger at the corner of rim board and ledger Sod, splash pads, gutters and sump pump extension are not installed As graded plot plan is required before sodding Sidewalk inspection must pass
Miscellaneous Correction
Corrective Action Required
11/22/2024
3725 SW Knoxville Back deck stairway landing pad is not installed Sod, splash pads, gutters and sump pump extension are not installed As graded plot plan is required before sodding Sidewalk inspection must pass Unit 3723 was not requested to be inspected Unit 3725 passed for TCO only This is a partial pass only
Plot Plan Inspection Passed 12/11/2024 12/11/2024
Miscellaneous Correction
Resolved
12/11/2024
As graded plot plan is required before sodding
Plot Plan Inspection Failed 12/12/2024 12/12/2024
Misc
Corrective Action Required
12/12/2024
as-graded submitted although final grade is incomplete. reschedule when there is fall away from house and final grade has been complete.
Occupancy Inspection - Codes Residential Not Ready 12/12/2024 12/12/2024 12/12/2024
Miscellaneous Correction
Corrective Action Required
11/22/2024
3725 SW Knoxville Back deck stairway landing pad is not installed Sod, splash pads, gutters and sump pump extension are not installed As graded plot plan is required before sodding Sidewalk inspection must pass Unit 3723 was not requested to be inspected Unit 3725 passed for TCO only This is a partial pass only
Misc
Corrective Action Required
12/12/2024
3723- 12/12/24 1. -Stair excessive rise top basement step over 3/8” 2. -Basement gfci not working. 3. -1st floor bath ,no fixtures installed. 4. -Garage:seal all ceiling penetrations at garage door hangers . Seal all box outs with approve material at the floor. 5. -Provide outlet for south side car space in garage. 2 outlets are on the left side of the garage 6. tread depth over 3/8” in difference top step in garage. 7. Bathroom faucets not installed 8. Missing front porch guard rail, over 30”. 9. Complete final grade, no grading at rear of house. 10. Install sewer tracer wire box. 11. Splash blocks not installed 12. Sump pump discharge 13. Water meter not flush with grade. 14. Final grade incomplete, re-schedule plot plan inspection when final grade is completed.( as-graded was submitted 12/10
Occupancy Inspection - Codes Residential Ready for Temp CO 12/17/2024 12/17/2024 12/17/2024
Miscellaneous Correction
Corrective Action Required
12/12/2024
3725 SW Knoxville Back deck stairway landing pad is not installed Sod, splash pads, gutters and sump pump extension are not installed As graded plot plan is required before sodding Sidewalk inspection must pass Unit 3723 was not requested to be inspected Unit 3725 passed for TCO only This is a partial pass only
Misc
Resolved
12/17/2024
3723- 12/12/24 1. -Stair excessive rise top basement step over 3/8” 2. -Basement gfci not working. 3. -1st floor bath ,no fixtures installed. 4. -Garage:seal all ceiling penetrations at garage door hangers . Seal all box outs with approve material at the floor. 5. -Provide outlet for south side car space in garage. 2 outlets are on the left side of the garage 6. tread depth over 3/8” in difference top step in garage. 7. Bathroom faucets not installed 8. Missing front porch guard rail, over 30”. 9. Complete final grade, no grading at rear of house. 10. Install sewer tracer wire box. 11. Splash blocks not installed 12. Sump pump discharge 13. Water meter not flush with grade. 14. Final grade incomplete, re-schedule plot plan inspection when final grade is completed.( as-graded was submitted 12/10
Miscellaneous Correction
Corrective Action Required
12/17/2024
3723 - Complete final grade, no grading at rear of house. - Install sewer tracer wire box. - Splash blocks not installed - Sump pump discharge - Water meter not flush with grade. - Final grade incomplete, re-schedule plot plan inspection when final grade is completed.( as-graded was submitted 12/10 3725 SW Knoxville Back deck stairway landing pad is not installed Sod, splash pads, gutters and sump pump extension are not installed As graded plot plan is required before sodding Sidewalk inspection must pass Both units passed for TCO only
Occupancy Inspection - Codes Residential Ready for Temp CO 12/20/2024 12/20/2024
Miscellaneous Correction
Resolved
12/20/2024
3725 SW Knoxville Back deck stairway landing pad is not installed Sod, splash pads, gutters and sump pump extension are not installed As graded plot plan is required before sodding Sidewalk inspection must pass Unit 3723 was not requested to be inspected Unit 3725 passed for TCO only This is a partial pass only
Miscellaneous Correction
Resolved
12/20/2024
3723 - Complete final grade, no grading at rear of house. - Install sewer tracer wire box. - Splash blocks not installed - Sump pump discharge - Water meter not flush with grade. - Final grade incomplete, re-schedule plot plan inspection when final grade is completed.( as-graded was submitted 12/10 3725 SW Knoxville Back deck stairway landing pad is not installed Sod, splash pads, gutters and sump pump extension are not installed As graded plot plan is required before sodding Sidewalk inspection must pass Both units passed for TCO only
Miscellaneous Correction
Corrective Action Required
12/20/2024
3723 - Complete final grade, no grading at rear of house. - Install sewer tracer wire box. - Splash blocks not installed - Sump pump discharge - Water meter not flush with grade. - Final grade incomplete, re-schedule plot plan inspection when final grade is completed.( as-graded was submitted 12/10 3725 SW Knoxville Sod, splash pads, gutters and sump pump extension are not installed Both units passed for TCO only TCO extension form was sent in and accepted by the city for 3725 only New expiration date for 3725 will be 01/22/2025
Occupancy Inspection - Codes Residential Ready for Temp CO 1/13/2025 01/13/2025
Miscellaneous Correction
Resolved
01/13/2025
3723 - Complete final grade, no grading at rear of house. - Install sewer tracer wire box. - Splash blocks not installed - Sump pump discharge - Water meter not flush with grade. - Final grade incomplete, re-schedule plot plan inspection when final grade is completed.( as-graded was submitted 12/10 3725 SW Knoxville Sod, splash pads, gutters and sump pump extension are not installed Both units passed for TCO only TCO extension form was sent in and accepted by the city for 3725 only New expiration date for 3725 will be 01/22/2025
Miscellaneous Correction
Corrective Action Required
01/13/2025
3723 - Complete final grade, no grading at rear of house. - Install sewer tracer wire box. - Splash blocks not installed - Sump pump discharge - Water meter not flush with grade. - Final grade incomplete, re-schedule plot plan inspection when final grade is completed.( as-graded was submitted 12/10 3725 SW Knoxville Sod, splash pads, gutters and sump pump extension are not installed Both units passed for TCO only Builder sent in a TCO extension request form New expiration date will be 02/22/2025
Occupancy Inspection - Codes Residential Ready for Temp CO 2/5/2025 02/05/2025
Miscellaneous Correction
Resolved
02/05/2025
3723 - Complete final grade, no grading at rear of house. - Install sewer tracer wire box. - Splash blocks not installed - Sump pump discharge - Water meter not flush with grade. - Final grade incomplete, re-schedule plot plan inspection when final grade is completed.( as-graded was submitted 12/10 3725 SW Knoxville Sod, splash pads, gutters and sump pump extension are not installed Both units passed for TCO only Builder sent in a TCO extension request form New expiration date will be 02/22/2025
Miscellaneous Correction
Corrective Action Required
02/05/2025
3723 and 3725 - Install sewer tracer wire box. - Splash blocks not installed - Sump pump discharge - Water meter not flush with grade. - Final grade incomplete, re-schedule plot plan inspection when final grade is completed.( as-graded was submitted 12/10 Sod, splash pads, gutters and sump pump extension are not installed Both units passed for TCO only Builder sent in a TCO extension request form New expiration date will be 03/22/2025
Occupancy Inspection - Codes Residential Failed 3/10/2025 03/10/2025
Miscellaneous Correction
Corrective Action Required
02/05/2025
3723 and 3725 - Install sewer tracer wire box. - Splash blocks not installed - Sump pump discharge - Water meter not flush with grade. - Final grade incomplete, re-schedule plot plan inspection when final grade is completed.( as-graded was submitted 12/10 Sod, splash pads, gutters and sump pump extension are not installed Both units passed for TCO only Builder sent in a TCO extension request form New expiration date will be 03/22/2025
Misc
Corrective Action Required
03/10/2025
TCO expired , please send in Extension form when items will be comopleted.
Plot Plan Inspection Passed 05/02/2025
Misc
Resolved
05/02/2025
as-graded submitted although final grade is incomplete. reschedule when there is fall away from house and final grade has been complete.
Erosion Control Inspection Residential Passed 05/02/2025
Miscellaneous Correction
Resolved
05/02/2025
Erosion control is in place and must be properly maintained until CofO
Occupancy Inspection - Codes Residential Failed 5/2/2025 5/2/2025 05/02/2025
Miscellaneous Correction
Corrective Action Required
03/10/2025
3723 and 3725 - Install sewer tracer wire box
Misc
Corrective Action Required
03/10/2025
TCO expired , please send in Extension form when items will be comopleted.
Occupancy Inspection - Codes Residential Ready for Temp CO 5/27/2025 05/27/2025
Miscellaneous Correction
Corrective Action Required
05/02/2025
3723 and 3725 - Install sewer tracer wire box
Misc
Corrective Action Required
05/02/2025
TCO expired , please send in Extension form when items will be comopleted.
Occupancy Inspection - Codes Residential Full C of O 6/18/2025 6/18/2025 06/18/2025
Miscellaneous Correction
Corrective Action Required
05/27/2025
3723 and 3725 - Install sewer tracer wire box
Misc
Corrective Action Required
05/27/2025
TCO expired , please send in Extension form when items will be comopleted.
Documents & Images
Date Uploaded File Type Document Name
04/25/2024 OS #85 - ENGINEERED PLANS
04/25/2024 OS #85 - PERMIT APP
04/25/2024 OS #85 - PLOT PLAN
04/25/2024 OS #85 - TRUSS DETAILS
04/25/2024 OS #85 - TRUSS LAYOUT
04/29/2024 Permit Codes Residential Plan Review
04/29/2024 Approved Plans APPROVED TRUSS LAYOUT
04/29/2024 Approved Plans APPROVED TRUSS PACKAGE
04/29/2024 Approved Plans APPROVED PLANS
05/02/2024 LOT 85 CITY
05/02/2024 Plot Plan APPROVED PLOT PLAN
05/02/2024 Permit Codes Residential Plan Review
05/02/2024 Permit DS Building Permit
05/02/2024 Receipt Receipt for transaction:2024-002876
05/11/2024 3RD Party Insp Report Footing Inspection Report 5-8-24
05/14/2024 Letter INSPECTION SUMMARY
05/14/2024 Letter INSPECTION SUMMARY
05/14/2024 Letter INSPECTION SUMMARY
05/14/2024 Letter INSPECTION SUMMARY
05/14/2024 Letter INSPECTION SUMMARY
05/14/2024 Letter INSPECTION SUMMARY
05/22/2024 Letter INSPECTION SUMMARY
05/23/2024 Letter INSPECTION SUMMARY
05/31/2024 Letter INSPECTION SUMMARY
05/31/2024 Letter INSPECTION SUMMARY
05/31/2024 Letter INSPECTION SUMMARY
07/19/2024 Letter INSPECTION SUMMARY
07/25/2024 Letter INSPECTION SUMMARY
08/28/2024 Letter INSPECTION SUMMARY
08/28/2024 Letter INSPECTION SUMMARY
08/28/2024 Letter INSPECTION SUMMARY
08/28/2024 Letter INSPECTION SUMMARY
09/03/2024 Engineer Report/Study OFFSET SILL PLATE ENGINEER LETTER
09/09/2024 Engineer Report/Study ENGINEER TRUSS LETTER
09/10/2024 Letter INSPECTION SUMMARY
09/10/2024 Letter INSPECTION SUMMARY
09/10/2024 Letter INSPECTION SUMMARY
09/12/2024 Letter INSPECTION SUMMARY
09/19/2024 Letter INSPECTION SUMMARY
09/19/2024 Letter INSPECTION SUMMARY
09/20/2024 Letter INSPECTION SUMMARY
09/20/2024 Letter INSPECTION SUMMARY
09/25/2024 Letter INSPECTION SUMMARY
09/25/2024 Letter INSPECTION SUMMARY
09/25/2024 Letter INSPECTION SUMMARY
10/04/2024 Letter INSPECTION SUMMARY
10/04/2024 Letter INSPECTION SUMMARY
10/31/2024 Letter INSPECTION SUMMARY
11/01/2024 Letter INSPECTION SUMMARY
11/19/2024 Letter INSPECTION SUMMARY
11/19/2024 Letter INSPECTION SUMMARY
11/20/2024 Letter INSPECTION SUMMARY
11/20/2024 Letter INSPECTION SUMMARY
11/20/2024 Letter INSPECTION SUMMARY
11/20/2024 Letter INSPECTION SUMMARY
11/22/2024 Letter INSPECTION SUMMARY
11/22/2024 Certificate/License Codes Temporary Certificate of Occupancy
11/22/2024 Receipt Receipt for transaction:2024-009112
07/19/2024 Letter INSPECTION SUMMARY
12/10/2024 Plot Plan approved as graded plot plan
12/12/2024 Letter INSPECTION SUMMARY
12/12/2024 Letter INSPECTION SUMMARY
12/13/2024 Application Form TCO EXTENSION
12/17/2024 Letter INSPECTION SUMMARY
12/17/2024 Certificate/License Codes Temporary Certificate of Occupancy
12/17/2024 Receipt Receipt for transaction:2024-009559
12/20/2024 Letter INSPECTION SUMMARY
12/20/2024 Certificate/License Codes Temporary Certificate of Occupancy
12/20/2024 Receipt Receipt for transaction:2024-009618
01/09/2025 Application Form EXTENSION FORM
01/13/2025 Letter INSPECTION SUMMARY
01/13/2025 Certificate/License Codes Temporary Certificate of Occupancy
01/13/2025 Receipt Receipt for transaction:2025-000194
02/04/2025 OS #85 - TCO Extension 2_4_25
02/05/2025 Letter INSPECTION SUMMARY
02/05/2025 Certificate/License Codes Temporary Certificate of Occupancy
02/05/2025 Receipt Receipt for transaction:2025-000758
05/01/2025 Certificate/License Codes Temporary Certificate of Occupancy
05/01/2025 Receipt Receipt for transaction:2025-002733
05/02/2025 Letter INSPECTION SUMMARY
05/02/2025 Letter INSPECTION SUMMARY
05/02/2025 Letter INSPECTION SUMMARY
05/22/2025 Application Form TCO EXTENSION
05/27/2025 Letter INSPECTION SUMMARY
05/28/2025 Certificate/License Codes Temporary Certificate of Occupancy
05/28/2025 Receipt Receipt for transaction:2025-003913
06/18/2025 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home