Permit Application Status

PRRES20240700


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20240700
Building Permit - Residential
Issued
NEW DUPLEX
NEW DUPLEX - UNFINISHED BASEMENT - STOP WORK ORDER generated on 06/10/2024 12:00 AM by username 'Shawn Hoffman'. STOP WORK ORDER removed on 06/12/2024 12:00 AM by username 'Robb Popp'. APPROVED PLANS 11/7/24 WERE NOT STAMPED FULLY WHEN PUT IN THE PORTAL. HARD COPY STAMPED AT THE COUNTER AND SIGNED CHANGED PAGES Andrea Sessler 11/13/2024 3:24 PM STOP WORK ORDER generated on 11/22/2024 12:00 AM by username 'Khanh Nguyen'. STOP WORK ORDER removed on 11/27/2024 12:00 AM by username 'Khanh Nguyen'. STOP WORK ORDER generated on 01/22/2025 12:00 AM by username 'Robb Popp'. STOP WORK ORDER removed on 03/24/2025 12:00 AM by username 'John Jackson'.
02/19/2024
05/02/2024
10/29/2024
Locations
Contacts
ORCHARD PARK DEVELOPMENT LLC, Address:8 SW AA HWY, Phone:(816) 405-6688  
James Edward Tompkins, Address:612 NW Kay Dr, Phone:(816) 525-9833  
daburton@mail.com  
CLIMATE RESTORATION SERVICES LLC, Address:PO BOX 574, Phone:(816) 694-8164  
HOWERTON PLUMBING LLC, Address:195 NW AA HWY, Phone:(816) 694-0303  
PREMIER ELECTRIC & LIGHTING DESIGN, Address:PO BOX 1311, Phone:(816) 564-7660  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for New Duplex $2,240.42 $2,240.42 Paid 05/02/2024
8331507-Sanitary Sewer Development Fee $4,318.00 $4,318.00 Paid 05/02/2024
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 05/02/2024
7232302-Residential License Tax Fee $1,240.32 $1,240.32 Paid 05/02/2024
8331401-Water Tap Fee $7,520.00 $7,520.00 Paid 05/02/2024
8350015-Water Meter Fee $1,360.92 $1,360.92 Paid 05/02/2024
Outstanding Fees Amount Paid Owing Date Paid
9110080-Not Ready Inspection Fee $75.00 $0.00 $75.00 Not Paid
9110080-3rd and Subsequent Inspection Fee (Per Hour) $75.00 $0.00 $75.00 Not Paid
9110080-3rd and Subsequent Inspection Fee (Per Hour) $75.00 $0.00 $75.00 Not Paid
9110080-3rd and Subsequent Inspection Fee (Per Hour) $75.00 $0.00 $75.00 Not Paid


$300.00    Add Fees to My Cart
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Plot Plan Inspection Pending
Foundation Inspection - Commercial Pending
Underslab Electrical Inspection - Residential Pending
Occupancy Inspection - Codes Residential Pending
Investigation Inspection Pending
Rated Assembly Inspection Pending
Misc
Corrective Action Required
01/27/2025
-Unit 205 approved Unit 207- firetape attic space, seal all gaps and penetrations
Erosion Control Inspection Residential Pending
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
03/24/2025
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -Re establish erosion control methods at perimeter, post address, clean silt from street
Underslab Plumbing Inspection - Residential Failed - Stop Work 6/10/2024 6/10/2024 06/10/2024
Misc
Corrective Action Required
06/10/2024
STOP WORK - NO FOOTING INSPECTION ON FILE.
Footing Inspection - Residential Passed 6/12/2024 6/12/2024 06/12/2024
Misc
Informational
06/12/2024
Approved by David Ainsworth on 5/29/24
Erosion Control Inspection Residential Partial 6/12/2024 06/12/2024
Misc
Informational
06/12/2024
6/12/24 BMP in compliance at time of inspection
Underslab Plumbing Inspection - Residential Failed 6/13/2024 6/13/2024 06/13/2024
Misc
Corrective Action Required
06/10/2024
Backfill around foundation to provide access for inspection
Erosion Control Inspection Residential Partial 6/13/2024 06/13/2024
Misc
Informational
06/12/2024
6/13/24 BMP in compliance at time of inspection
Erosion Control Inspection Residential Partial 6/18/2024 06/18/2024
Misc
Informational
06/13/2024
6/18/24 BMP in compliance at time of inspection
Underslab Plumbing Inspection - Residential Passed 6/18/2024 6/18/2024 06/18/2024
Misc
Resolved
06/18/2024
Backfill around foundation to provide access for inspection
Rated Assembly Inspection Failed 7/22/2024 07/22/2024
Misc
Corrective Action Required
07/22/2024
Inspection for firewall only: -Complete MEPs -Provide UL assembly details, number, and screw pattern information -City approved, stamped plans must be on site for all inspections
Erosion Control Inspection Residential Failed 07/22/2024
Misc
Corrective Action Required
07/22/2024
-Restore BMPs at perimeter of lot
Gas Service Inspection - Residential Failed 9/17/2024 09/17/2024
G2417.4.1 Test Pressure
Corrective Action Required
09/17/2024
INSPECTION, TESTING AND PURGING. AMENDED 7-945. The test pressure to be used shall be not less than one and one-half times the proposed maximum working pressure, but not less than 10 psig (68.9kPa) irrespective of design pressure. For welded piping, and for piping carrying gas at pressures in excess of fourteen (14) inches water column pressure, the test pressure shall not be less than 60 psig. Where the test pressure exceeds 125 psig (862 kPa gauge), the test pressure shall not exceed a value that produces a hoop stress in the piping greater than 50 percent of the specified minimum yield strength of the pipe.
Electrical Service Inspection Failed 9/17/2024 09/17/2024
Misc
Corrective Action Required
09/17/2024
-PROVIDE PERMANENT LABELS AT EACH METER -EXPOSE UFER GROUND CONNECTION-THIS MUST BE ACCESSIBLE AT ALL TIMES
All Rough Inspection - Residential Failed 9/17/2024 09/17/2024
Misc
Corrective Action Required
09/17/2024
Not ready -complete all Fireblocking before rescheduling
Gas Service Inspection - Residential Failed 9/25/2024 09/25/2024
G2417.4.1 Test Pressure
Corrective Action Required
09/17/2024
INSPECTION, TESTING AND PURGING. AMENDED 7-945. The test pressure to be used shall be not less than one and one-half times the proposed maximum working pressure, but not less than 10 psig (68.9kPa) irrespective of design pressure. For welded piping, and for piping carrying gas at pressures in excess of fourteen (14) inches water column pressure, the test pressure shall not be less than 60 psig. Where the test pressure exceeds 125 psig (862 kPa gauge), the test pressure shall not exceed a value that produces a hoop stress in the piping greater than 50 percent of the specified minimum yield strength of the pipe. -Gauge does not work
Electrical Service Inspection Failed 9/25/2024 09/25/2024
Misc
Corrective Action Required
09/17/2024
-PROVIDE PERMANENT LABELS AT EACH METER -UFER GROUND CONNECTION MUST BE ACCESSIBLE AT ALL TIMES
All Rough Inspection - Residential Failed 9/23/2024 9/25/2024 09/25/2024
Misc
Corrective Action Required
09/17/2024
*Not Ready. Too many discrepancies between plans and on site conditions to perfom a complete inspection. This list shall serve as a general list for both units and is understood to be incomplete. -Install 5/8" anchor bolts at PFH per detail -Nail exterior sheathing at PFH header per detail -Land electrical at garage -Provide bocca plates and protection plates at all dwv 1.25" to face of framing or less -Back wall at dining not per plan and has no braced wall panel -Missing PFH at back corner -Protect electrical at island min of 6" above floor -NM insulation not landing inside of boxes min 1/2" multiple locations -Seal plate penetrations throughout -Nail all ceiling joists to rafters and rafters to plate per code -Nail all exterior corners and intersecting walls per code -Use approved fasteners at all stud shoes and straps -Protect dryer duct min 2" below plate line -Fireblock dead space at 2nd floor HVAC chase -Correct overbored or discontinous top plates throughout (dryer duct, return air, etc, dwv, etc.) -Trap arm length to be min 2 pipe size diameter at washer -Engineer to address rafters landing on knee wall and not connected to joists at top plate 2nd floor -Rafter not bearing on top plate second floor bathroom -Secure nm in attic space, garage and chases per code -Protect nm within 6' of attic access -Solid block between joists above load bearing walls -Provide vent to roof for all new fixtures -Any AAV must be accessible -Complete DWV in basement -Correct overbored studs throughout at bearing and non bearing walls -Remove closet wall and door in garage and revise plans -Revise firewall detail as previously discussed on rated assembly inspection -(2) walls on second floor changed location -Header size at rear wall not per plan -Roof supports in wrong location and landing on non bearing walls -Header at kitchen/dining supporting 2nd floor and exterior and ceilnig joists not on plans -Bearing wall on second floor is not above 1st floor LVL -Vertical vent stacks cannot recieve waste from water closets -Have engineer address all framing issues discussed on site with Mark Harding, revise and resubmit plans before any further inspections
Erosion Control Inspection Residential Partial 11/14/2024 11/14/2024 11/14/2024
Misc
Resolved
11/14/2024
-Restore BMPs at perimeter of lot
Electrical Service Inspection Failed 11/14/2024 11/14/2024 11/14/2024
Misc
Corrective Action Required
09/25/2024
-PROVIDE PERMANENT LABELS AT EACH METER -UFER GROUND CONNECTION MUST BE ACCESSIBLE AT ALL TIMES
Gas Service Inspection - Residential Failed 11/14/2024 11/14/2024 11/14/2024
G2417.4.1 Test Pressure
Corrective Action Required
09/25/2024
INSPECTION, TESTING AND PURGING. AMENDED 7-945. The test pressure to be used shall be not less than one and one-half times the proposed maximum working pressure, but not less than 10 psig (68.9kPa) irrespective of design pressure. For welded piping, and for piping carrying gas at pressures in excess of fourteen (14) inches water column pressure, the test pressure shall not be less than 60 psig. Where the test pressure exceeds 125 psig (862 kPa gauge), the test pressure shall not exceed a value that produces a hoop stress in the piping greater than 50 percent of the specified minimum yield strength of the pipe. -Gauge does not work
All Rough Inspection - Residential Not Ready 11/14/2024 11/14/2024
Misc
Corrective Action Required
09/25/2024
11/14/24 *Not Ready. Too many deficiencies and items not addressed from previous inspection. Complete items on this list before rescheduling. This list shall serve as a general list for both units and is understood to be incomplete. -Remove tyvek to expose nailing pattern at all braced walls -Install 5/8" anchor bolts at PFH per detail-Not done -Nail exterior sheathing at PFH header per detail-Not done -Land electrical at garage-Not done -Anchor bolts to be in middle third of plate at garage -Strap top plate lapped less than 24” at garage wall -Fur down ceiling joists at hvac in garage for R30 insulation -Provide bocca plates and protection plates at all dwv 1.25" to face of framing or less-Not done -Structural strap both sides load bearing stairwell wall at over bored top plate lapped less than 24” at garage -Use proper fasteners at stud shoes -Missing PFH at kitchen and living room-Provide engineered correction -NM insulation not landing inside of boxes min 1/2" multiple locations -Seal plate penetration at stairwell wall -Nail all ceiling joists to rafters and rafters to plate per code-not done -Nail all exterior corners and intersecting walls per code-Not done -Use approved fasteners at all stud shoes and straps -Protect dryer duct min 2" below plate line-not done -Fireblock dead space at 2nd floor HVAC chase -Correct overbored or discontinous top plates throughout (dryer duct, return air, etc, dwv, etc.)-not done -Trap arm length to be min 2 pipe size diameter at washer -Engineer to address rafters landing on knee wall and not connected to joists at top plate 2nd floor-not done -Rafter not bearing on top plate second floor bathroom-not addressed -Secure nm in attic space, garage and chases per code -Protect nm within 6' of attic access -Solid block between joists above load bearing walls-not done -Provide vent to roof for all new fixtures -Any AAV must be accessible -Complete DWV in basement -Correct overbored studs throughout at bearing and non bearing walls -Missing (3) 2x10 beam in kitchen per revised drawings -Missing (2) 11 7/8” LVLs at living/dining room/Stairwell per revised drawings -Roof supports in wrong location and landing on non bearing walls -Header at kitchen/dining supporting 2nd floor and exterior and ceiling joists not on plans -Bearing wall on second floor is not above 1st floor LVL -Vertical vent stacks cannot receive waste from water closets -Have engineer address all framing issues discussed on site with Mark Harding, revise and resubmit plans before any further inspections
All Rough Inspection - Residential Failed - Stop Work 11/22/2024 11/22/2024 11/22/2024
Misc
Corrective Action Required
11/14/2024
11/22/24 **Inspection denied and stop-work issued. Insulation already installed at garage ceiling and floor rim without approval. Shall remove all insulation before scheduling an inspection 11/14/24 *Not Ready. Too many deficiencies and items not addressed from previous inspection. Complete items on this list before rescheduling. This list shall serve as a general list for both units and is understood to be incomplete. -Remove tyvek to expose nailing pattern at all braced walls -Install 5/8" anchor bolts at PFH per detail-Not done -Nail exterior sheathing at PFH header per detail-Not done -Land electrical at garage-Not done -Anchor bolts to be in middle third of plate at garage -Strap top plate lapped less than 24” at garage wall -Fur down ceiling joists at hvac in garage for R30 insulation -Provide bocca plates and protection plates at all dwv 1.25" to face of framing or less-Not done -Structural strap both sides load bearing stairwell wall at over bored top plate lapped less than 24” at garage -Use proper fasteners at stud shoes -Missing PFH at kitchen and living room-Provide engineered correction -NM insulation not landing inside of boxes min 1/2" multiple locations -Seal plate penetration at stairwell wall -Nail all ceiling joists to rafters and rafters to plate per code-not done -Nail all exterior corners and intersecting walls per code-Not done -Use approved fasteners at all stud shoes and straps -Protect dryer duct min 2" below plate line-not done -Fireblock dead space at 2nd floor HVAC chase -Correct overbored or discontinous top plates throughout (dryer duct, return air, etc, dwv, etc.)-not done -Trap arm length to be min 2 pipe size diameter at washer -Engineer to address rafters landing on knee wall and not connected to joists at top plate 2nd floor-not done -Rafter not bearing on top plate second floor bathroom-not addressed -Secure nm in attic space, garage and chases per code -Protect nm within 6' of attic access -Solid block between joists above load bearing walls-not done -Provide vent to roof for all new fixtures -Any AAV must be accessible -Complete DWV in basement -Correct overbored studs throughout at bearing and non bearing walls -Missing (3) 2x10 beam in kitchen per revised drawings -Missing (2) 11 7/8” LVLs at living/dining room/Stairwell per revised drawings -Roof supports in wrong location and landing on non bearing walls -Header at kitchen/dining supporting 2nd floor and exterior and ceiling joists not on plans -Bearing wall on second floor is not above 1st floor LVL -Vertical vent stacks cannot receive waste from water closets -Have engineer address all framing issues discussed on site with Mark Harding, revise and resubmit plans before any further inspections
Gas Service Inspection - Residential Failed 11/27/2024 11/27/2024
G2417.4.1 Test Pressure
Corrective Action Required
11/14/2024
INSPECTION, TESTING AND PURGING. AMENDED 7-945. The test pressure to be used shall be not less than one and one-half times the proposed maximum working pressure, but not less than 10 psig (68.9kPa) irrespective of design pressure. For welded piping, and for piping carrying gas at pressures in excess of fourteen (14) inches water column pressure, the test pressure shall not be less than 60 psig. Where the test pressure exceeds 125 psig (862 kPa gauge), the test pressure shall not exceed a value that produces a hoop stress in the piping greater than 50 percent of the specified minimum yield strength of the pipe. -Gauge does not work
Electrical Service Inspection Passed 11/27/2024 11/27/2024
Misc
Resolved
11/27/2024
Erosion Control Inspection Residential Partial 11/27/2024 11/27/2024 11/27/2024
Misc
Corrective Action Required
11/27/2024
Erosion control in compliance
All Rough Inspection - Residential Failed 11/27/2024 11/27/2024
Misc
Corrective Action Required
11/22/2024
Unit 205: -Install flashing above window trim -Strap top plate lapped less than 24” at garage wall -Vent master bathroom shower trap. Support plumbing at 4 ft or less -Fb duct chase from soffit and joist space -Provide 5/8” type X rock at fire separation wall inside duct chases and soffit space; take care of the rated wall before all-rough can be approved -Provide 4-stud pack at stair -Toe nail joists to wall top plates -Nail rear PFH wall sheathing to headers and rim -Protect refrigerator water line at bottom wall plate. Use BOCA strike plate -Fb laundry wall at top plate -Provide wall receptacle at master bedroom wall exceeding 2 ft -Washer plumbing outside of wall space -Protect water lines at master bathroom shower -Protect nm across studdings within 6' of attic access -Protect dryer duct min 2" below plate line -Provide direct illumination of basement stair treads per code -Gas test failed. No pressure -Provide a stud directly under (2)2x10 above bottom stair landing -Fb basement wall from all soffits -Provide venting for basement bathroom sink. Vent connection cannot be below trap weir -Provide stud shoes for basement non-bearing wall studs bored more than 60% -Vent half bathroom water closet per code. Cannot use the 3” waste stack to vent the water closet -Provide 5/8” type X rock at fire separation wall at back of furnace -Toe nail joists to wall sill plates -Staple wiring minimum 1.25” away from nailing surface -Remove insulation and expose the rim below the rear PFH walls **DO NOT INSULATE Unit 207: -Install flashing above window trim -Strap top plate lapped less than 24” at garage wall -Support plumbing above garage at 4 ft or less -Provide 5/8” type X rock at fire separation wall inside duct chases and soffit space; take care of the rated wall before all-rough can be approved -Vent 2nd floor bathroom tub trap -Reinforce notched joist (same location as above) -Fb duct chase from soffit and joist space -Protect water lines at half bathroom/duct chase wall -Provide 4-stud pack at stair -Provide full support for (2)2x10 above entry door header -Toe nail joists to wall top plates -Tighten down the PFH wall hold down nut at rear dining -Nail rear PFH wall sheathing to headers (with 3” grid pattern) and rim -Protect wiring at rear dining wall corner -Protect refrigerator water line at bottom wall plate. Use BOCA strike plate -Install stud shoe at laundry wall where bored more than 60% -Provide wall receptacle at master bedroom wall exceeding 2 ft -Protect nm across studdings within 6' of attic access -Protect dryer duct min 2" below plate line -Provide direct illumination of basement stair treads per code -Provide a stud directly under (2)2x10 above bottom stair landing -Fb basement wall from all soffits -Provide stud shoes for basement non-bearing wall studs bored more than 60% -Vent half bathroom water closet per code. Cannot use the 3” waste stack to vent the water closet -Provide 5/8” type X rock at fire separation wall at back of furnace -Toe nail joists to wall sill plates -Staple wiring minimum 1.25” away from nailing surface **DO NOT INSULATE
All Rough Inspection - Residential Failed 12/5/2024 12/5/2024 12/05/2024
Misc
Corrective Action Required
11/27/2024
Unit 205: -Install flashing above window trim -Vent master bathroom shower trap. Support plumbing at 4 ft or less -Fb duct chase from soffit and joist space-seal gaps and penetrations -Provide 5/8” type X rock at fire separation wall inside duct chases and soffit space; take care of the rated wall before all-rough can be approved-Secure drywall and seal gaps -Provide wall receptacle at master bedroom wall exceeding 2 ft-seal plate penetrations -Protect water lines at master bathroom shower-DWV outside of shower wall -Provide a stud directly under (2)2x10 above bottom stair landing-Use stud grade material and nail 12" oc -Fb basement wall from all soffits-seal gaps -Strap load bearing wall both sides at top plate stairwell wall overbored for vent -Provide venting for basement bathroom sink. Vent connection cannot be below trap weir -Block between all ceiling joists above load bearing walls -Provide stud shoes for basement non-bearing wall studs bored more than 60%-Use proper nails -Protect DWV at stairwell wall -Egress windows in 2nd floor above 44"-must comply with R310 -Complete DWV in basement -Secure receptacle at garage -Engineer to provide specs for hold down devices used as alternative on back wall PFH locations **DO NOT INSULATE Unit 207: -Install flashing above window trim -Support plumbing above garage at 4 ft or less -Provide 5/8” type X rock at fire separation wall inside duct chases and soffit space; take care of the rated wall before all-rough can be approved -Reinforce notched joist (same location as above) (Garage) -Fb duct chase from soffit and joist space-Seal gaps -Protect water lines at half bathroom/duct chase wall -Provide 4-stud pack at stair-Use stud grade lumber -Tighten down the PFH wall hold down nut at rear dining -Protect wiring at rear dining wall corner -Protect refrigerator water line at bottom wall plate. Use BOCA strike plate -Install stud shoe at laundry wall where bored more than 60%-Use proper fasteners -Provide wall receptacle at master bedroom wall exceeding 2 ft-seal penetrations -Protect dryer duct min 2" below plate line -Provide a stud directly under (2)2x10 above bottom stair landing-Use stud grade lumber -Fb basement wall from all soffits-Seal gaps -Provide stud shoes for basement non-bearing wall studs bored more than 60%-Use nails -Vent half bathroom water closet per code. Cannot use the 3” waste stack to vent the water closet -Provide 5/8” type X rock at fire separation wall at back of furnace -Engineer to provide specs for hold down devices used as alternative on back wall PFH locations -Egress windows in 2nd floor above 44"-must comply with R310 **DO NOT INSULATE
All Rough Inspection - Residential Failed 12/10/2024 12/10/2024 12/10/2024
Misc
Corrective Action Required
12/05/2024
Unit 205: -Fb duct chase from soffit and joist space-seal gaps and penetrations -Protect water lines at master bathroom shower-DWV outside of shower wall -Fb basement wall from all soffits-seal gaps -Provide stud shoes for basement non-bearing wall studs bored more than 60%-Use proper nails -Egress windows in 2nd floor above 44"-must comply with R310 -Complete DWV in basement -Engineer to provide specs for hold down devices used as alternative on back wall PFH locations **DO NOT INSULATE Unit 207: -Provide 5/8” type X rock at fire separation wall inside duct chases and soffit space; take care of the rated wall before all-rough can be approved-Seal gaps and penetrations -Fb duct chase from soffit and joist space-Seal gaps -Install stud shoe at laundry wall where bored more than 60%-Use proper fasteners -Provide wall receptacle at master bedroom wall exceeding 2 ft-seal penetrations -Protect dryer duct min 2" below plate line -Fb basement wall from all soffits-Seal gaps -Provide stud shoes for basement non-bearing wall studs bored more than 60%-Use nails -Provide 5/8” type X rock at fire separation wall at back of furnace -Engineer to provide specs for hold down devices used as alternative on back wall PFH locations -Egress windows in 2nd floor above 44"-must comply with R310
All Rough Inspection - Residential Failed 12/13/2024 12/13/2024 12/13/2024
Misc
Corrective Action Required
12/10/2024
Unit 205: -DWV outside of shower wall-NOT ADDRESSED -Complete DWV at grinder pump (Can verify when complete) *OK to insulate, do not cover inspection items Unit 207: -Complete DWV at grinder pump (Can verify when complete)
Water Service Inspection - R Passed 12/16/2024 12/16/2024 12/16/2024
Sewer Service Inspection - R Passed 12/17/2024 12/17/2024 12/17/2024
All Rough Inspection - Residential Passed 12/18/2024 12/18/2024 12/18/2024
Misc
Resolved
12/18/2024
Unit 205: -DWV outside of shower wall-NOT ADDRESSED -Complete DWV at grinder pump (Can verify when complete) *OK to insulate, do not cover inspection items Unit 207: -Complete DWV at grinder pump (Can verify when complete)
Gas Service Inspection - Residential Failed 1/17/2025 01/17/2025
G2417.4.1 Test Pressure
Corrective Action Required
11/27/2024
INSPECTION, TESTING AND PURGING. AMENDED 7-945. The test pressure to be used shall be not less than one and one-half times the proposed maximum working pressure, but not less than 10 psig (68.9kPa) irrespective of design pressure. For welded piping, and for piping carrying gas at pressures in excess of fourteen (14) inches water column pressure, the test pressure shall not be less than 60 psig. Where the test pressure exceeds 125 psig (862 kPa gauge), the test pressure shall not exceed a value that produces a hoop stress in the piping greater than 50 percent of the specified minimum yield strength of the pipe. -Gauge does not work
Misc
Corrective Action Required
01/17/2025
1/17/25 -no access
Gas Service Inspection - Residential Passed 1/22/2025 1/22/2025 01/22/2025
G2417.4.1 Test Pressure
Resolved
01/22/2025
INSPECTION, TESTING AND PURGING. AMENDED 7-945. The test pressure to be used shall be not less than one and one-half times the proposed maximum working pressure, but not less than 10 psig (68.9kPa) irrespective of design pressure. For welded piping, and for piping carrying gas at pressures in excess of fourteen (14) inches water column pressure, the test pressure shall not be less than 60 psig. Where the test pressure exceeds 125 psig (862 kPa gauge), the test pressure shall not exceed a value that produces a hoop stress in the piping greater than 50 percent of the specified minimum yield strength of the pipe. -Gauge does not work
Misc
Resolved
01/22/2025
1/17/25 -no access
Rated Assembly Inspection Failed - Stop Work 1/22/2025 1/22/2025 01/22/2025
Misc
Corrective Action Required
07/22/2024
-Entire 1 hour rated separation wall has been covered without inspections on both units
Rated Assembly Inspection Failed 1/27/2025 1/27/2025 01/27/2025
Misc
Corrective Action Required
01/22/2025
-Unit 205 approved Unit 207- firetape attic space, seal all gaps and penetrations
Erosion Control Inspection Residential Failed 2/4/2025 2/4/2025 02/04/2025
Misc
Resolved
02/04/2025
Erosion control in compliance
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
02/04/2025
2/4/25 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -Provide erosion control methods at perimeter -Maintain gravel filter with min 6" lift of min 3/4" gravel -Clean silt and debris from street
Erosion Control Inspection Residential Failed 3/24/2025 3/24/2025 03/24/2025
DCM3 ESC REQUIRED 2 DAY
Resolved
03/24/2025
3/24/25 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -Provide erosion control methods at perimeter -Maintain gravel filter with min 6" lift of min 3/4" gravel -Clean silt and debris from street
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
03/24/2025
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -Re establish erosion control methods at perimeter, post address, clean silt from street
Driveway Inspection Partial 3/24/2025 3/24/2025 03/24/2025
Misc
Informational
03/24/2025
Pre-inspection Driveway forms and materials appear to meet specification.
Driveway Inspection Passed 03/26/2025
Misc
Informational
03/24/2025
Pre-inspection Driveway forms and materials appear to meet specification. 03/26/25 Wednesday JMJ Driveway passed final inspection.
Documents & Images
Date Uploaded File Type Document Name
02/19/2024 2020-01_Sequoia Duplex Central - Basement Alternate 8-3-23
02/19/2024 Sequoia Residential Building 1
02/19/2024 License_Tax_Application #1
02/20/2024 2020-01_Sequoia Duplex Central - 19 Basement Alternate 8-10-23
02/20/2024 Application Form Residental Permit Application Building 1
02/21/2024 Permit Codes Residential Plan Review
03/12/2024 2020-01_Sequoia Duplex Central - 19_Building 1_03_03_2024_SIGNED
03/12/2024 Permit Codes Residential Plan Review
03/19/2024 2020-0708 Structural Details FINAL
03/19/2024 Residental Permit Application Building 1
03/19/2024 Permit Codes Residential Plan Review
03/25/2024 2020-0708 Structural Details FINAL
03/25/2024 2020-0708 Structural Details FINAL
03/25/2024 2020-01_Sequoia Duplex Central - 19_Building 1_03_23_2024_SIGNED
03/27/2024 Permit Codes Residential Plan Review
04/23/2024 Sequoia Combined for city
04/25/2024 Permit Codes Residential Plan Review
04/29/2024 Plans Sequoia 2nd code Response COMBINED
04/30/2024 Permit Codes Residential Plan Review
05/01/2024 Plans plans
05/02/2024 Approved Plans APPROVED PLANS
05/02/2024 Plot Plan APPROVED PLOT PLAN
05/02/2024 Permit Codes Residential Plan Review
05/02/2024 Application NEW
05/02/2024 Application Form APPLICATION FRONT PAGE
05/02/2024 Permit Codes Residential Plan Review
05/02/2024 Permit DS Building Permit
05/02/2024 Receipt Receipt for transaction: 2024-002874
06/06/2024 Re-Submittal 6-6-24
06/06/2024 Sequoia A100-rev 6-3-24
06/07/2024 Approved Plans APPROVED REVISED BASEMENT PLAN
06/10/2024 Letter Stop Work Order
06/11/2024 3RD Party Insp Report M L Crose 205 & 207 NW Orchard Ct LSMO 3rd Party Footing Inspection Report 5-29-24
06/12/2024 Letter INSPECTION SUMMARY
06/12/2024 Letter INSPECTION SUMMARY
06/13/2024 Letter INSPECTION SUMMARY
06/13/2024 Letter INSPECTION SUMMARY
06/18/2024 Letter INSPECTION SUMMARY
07/22/2024 Letter INSPECTION SUMMARY
07/22/2024 Letter INSPECTION SUMMARY
07/22/2024 Letter INSPECTION SUMMARY
09/17/2024 Letter INSPECTION SUMMARY
09/17/2024 Letter INSPECTION SUMMARY
09/17/2024 Letter INSPECTION SUMMARY
09/25/2024 Letter INSPECTION SUMMARY
09/25/2024 Letter INSPECTION SUMMARY
09/25/2024 Letter INSPECTION SUMMARY
11/06/2024 205 NW Orchard Court Review Response 11-6-24
11/07/2024 Approved Plans APPROVED REVISED PLANS
11/14/2024 Letter INSPECTION SUMMARY
11/14/2024 Letter INSPECTION SUMMARY
11/14/2024 Letter INSPECTION SUMMARY
11/14/2024 Letter INSPECTION SUMMARY
11/19/2024 205 NW ORCHARD COURT REVIEW RESPONSE 11-18-24
11/19/2024 A-102 - 1 - 11-18-24
11/19/2024 Approved Plans approved sheet A102
11/22/2024 Letter Stop Work Order
11/27/2024 Letter INSPECTION SUMMARY
11/27/2024 Letter INSPECTION SUMMARY
11/27/2024 Letter INSPECTION SUMMARY
11/27/2024 Letter INSPECTION SUMMARY
12/05/2024 205-207 NW ORCHARD CT FRAMING INSP 12-4-24
12/05/2024 Letter INSPECTION SUMMARY
12/10/2024 Letter INSPECTION SUMMARY
12/11/2024 Engineer Report/Study PFH Hold-downs
12/13/2024 Letter INSPECTION SUMMARY
12/16/2024 Letter INSPECTION SUMMARY
12/17/2024 Letter INSPECTION SUMMARY
12/18/2024 Letter INSPECTION SUMMARY
01/17/2025 Letter INSPECTION SUMMARY
01/22/2025 Letter INSPECTION SUMMARY
01/22/2025 Letter Stop Work Order
01/27/2025 Letter INSPECTION SUMMARY
02/04/2025 Letter INSPECTION SUMMARY
03/24/2025 Letter INSPECTION SUMMARY
03/24/2025 Letter INSPECTION SUMMARY
03/26/2025 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home