Permit Application Status

PRRES20225681


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20225681
Building Permit - Residential
Certificate of Occupancy
MCFARLAND CUSTOM BUILDERS INC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED DECK STOP WORK ORDER generated on 01/13/2023 12:00 AM by username 'Mitchell Schwarz'. STOP WORK ORDER removed on 01/30/2023 12:00 AM by username 'Mitchell Schwarz'. STOP WORK ORDER generated on 08/08/2023 12:00 AM by username 'Mitchell Schwarz'. STOP WORK ORDER removed on 09/05/2023 12:00 AM by username 'Mitchell Schwarz'.
11/11/2022
12/15/2022
06/11/2023
12/19/2024
Locations
Contacts
MCFARLAND CUSTOM BUILDERS, Address:P O BOX 25285, Phone:(816) 215-1660  
MCFARLAND CUSTOM BUILDERS INC, Address:9601 NE BARRY RD STE 130  
Marisa McFarland, Address:suite 130  
BRENT@MCFARLANDKC.COM  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sanitary Sewer Development Fee $1,384.00 $1,384.00 Paid 12/15/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 12/15/2022
7232302-Residential License Tax Fee $1,022.72 $1,022.72 Paid 12/15/2022
8331401-Water Tap Fee $3,730.00 $3,730.00 Paid 12/15/2022
8350015-Water Meter Fee $550.50 $550.50 Paid 12/15/2022
9110078-Valuation Fee New Single Family $2,057.42 $2,057.42 Paid 12/15/2022
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 08/29/2023
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 09/18/2023
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 09/18/2023
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 04/29/2024
9110080-3rd and Subsequent Inspection Fee (Per Hour) $75.00 $75.00 Paid 04/29/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 04/29/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 07/02/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 07/02/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 10/15/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 10/15/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 11/19/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Failed 1/13/2023 1/13/2023 01/13/2023
Misc
Corrective Action Required
01/13/2023
-inspection denied no address -maintain erosion control -footing poured without inspection
Erosion Control Inspection Residential Failed 1/13/2023 01/13/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
01/13/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Misc
Corrective Action Required
01/13/2023
maintain erosion control.
Footing Inspection - Residential Failed - Stop Work 1/13/2023 01/13/2023
Misc
Corrective Action Required
01/13/2023
STOP WORK ISSUED footing poured without inspection. Mitchell Schwarz 01/13/2023 9:05 AM
Sewer Service Inspection - R Passed 1/30/2023 (1:00) 1/30/2023 01/30/2023
Water Service Inspection - R Passed 1/31/2023 01/31/2023
Footing Inspection - Residential Passed 2/15/2023 02/15/2023
Misc
Resolved
02/15/2023
STOP WORK ISSUED footing poured without inspection. Mitchell Schwarz 01/13/2023 9:05 AM
Misc
Resolved
02/15/2023
Misc
Resolved
02/15/2023
Third party inspection completed
Underslab Plumbing Inspection - Residential Failed 2/15/2023 2/15/2023 02/15/2023
Misc
Corrective Action Required
01/13/2023
Support interior drain tile at floor level to flow properly to sump pit. Reinspection required. Reinstall erosion control prior to next inspection.
Erosion Control Inspection Residential Failed 2/15/2023 2/15/2023 02/15/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
01/13/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Misc
Resolved
02/15/2023
maintain erosion control.
Underslab Plumbing Inspection - Residential Not Ready 3/14/2023 3/14/2023 03/14/2023
Misc
Corrective Action Required
02/15/2023
Support interior drain tile at floor level to flow properly to sump pit. Reinspection required. Reinstall erosion control prior to next inspection. Drain tile not addressed -Mitchell Schwarz 3/14/23 1:25pm
Underslab Plumbing Inspection - Residential Passed 3/31/2023 3/31/2023 03/31/2023
Misc
Resolved
03/31/2023
Support interior drain tile at floor level to flow properly to sump pit. Reinspection required. Reinstall erosion control prior to next inspection. Drain tile not addressed -Mitchell Schwarz 3/14/23 1:25pm
Erosion Control Inspection Residential Failed 6/2/2023 06/02/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
06/02/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
06/02/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Erosion Control Inspection Residential Failed 6/22/2023 06/22/2023
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
06/02/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Misc
Corrective Action Required
06/22/2023
-Repair downed silt fence. -maintain vegetation
Electrical Service Inspection Failed 7/20/2023 7/20/2023 07/20/2023
Misc
Corrective Action Required
07/20/2023
-Connect the GEC to the middle grounded bus bar.
Gas Service Inspection - Residential Passed 7/20/2023 7/20/2023 07/20/2023
Erosion Control Inspection Residential Failed 7/20/2023 07/20/2023
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
06/22/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Misc
Corrective Action Required
06/22/2023
-Repair downed silt fence. -maintain vegetation
All Rough Inspection - Residential Failed 7/20/2023 7/20/2023 07/20/2023
Misc
Corrective Action Required
07/20/2023
INSPECTION DENIED NO FURTHER INSPECTIONS UNTIL EROSION CONTROL IS IN COMPLIANCE -no city stamped plans on site -no fire blocking -uncover garage portal frame before inspection
Erosion Control Inspection Residential Failed 7/26/2023 07/26/2023
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
07/20/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Misc
Corrective Action Required
07/20/2023
-Repair downed silt fence. -maintain vegetation around whole lot.
Erosion Control Inspection Residential Failed 8/1/2023 08/01/2023
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
07/26/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Misc
Corrective Action Required
07/26/2023
-Repair downed silt fence. -maintain vegetation around whole lot.
Erosion Control Inspection Residential Failed - Stop Work 8/8/2023 08/08/2023
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
08/01/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Misc
Corrective Action Required
08/01/2023
-Repair downed silt fence. At front and SW side of lot.
Erosion Control Inspection Residential Failed 8/30/2023 8/30/2023 08/30/2023
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
08/08/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Misc
Resolved
08/30/2023
-Repair downed silt fence. At front and SW side of lot.
Misc
Corrective Action Required
08/30/2023
Maintain overgrown vegetation on all of lot
Erosion Control Inspection Residential Partial 9/5/2023 9/5/2023 09/05/2023
DCM3 ESC REQUIRED 2 DAY
Resolved
09/05/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Misc
Resolved
09/05/2023
Maintain overgrown vegetation on all of lot
Misc
Informational
09/05/2023
Erosion control back in compliance.
All Rough Inspection - Residential Not Ready 9/11/2023 9/11/2023 09/11/2023
Misc
Corrective Action Required
07/20/2023
INSPECTION DENIED -no fire blocking -uncover garage portal frame before inspection
Electrical Service Inspection Not Ready 9/11/2023 9/11/2023 09/11/2023
Misc
Corrective Action Required
07/20/2023
-Connect the GEC to the middle grounded bus bar.
All Rough Inspection - Residential Failed 9/21/2023 9/21/2023 09/21/2023
Misc
Resolved
09/21/2023
INSPECTION DENIED -no fire blocking -uncover garage portal frame before inspection
Misc
Corrective Action Required
09/21/2023
-uncover garage portal frame nailing. -double every other floor joist to plans above garage -finish plumbing in garage -missing anchor bolts Sw side of garage -fire block S garage wall to ceiling space and furr down -fireblock N garage wall in furr downs -fire block E garage wall into furr down -nail Guards at top plate near garage entry -roof boots to be installed -fire block pantry furr down -frame breakfast room E wall to cspf specifications -uncover covered rear deck for inspection -address all holes drilled through floor joist above hearth room and kitchen closer than 2” to one another -complete hearth room rear wall to code/plans -fire block living wall to under stair landing -provide some/co within immediate facility of bed rooms 2nd floor -complete laundry furr out wall and fire block -master bath toilet missing bath vent -address snow blocking through out. Missing areas and gaps in blocking -provide support and hold down for ridge above bed 4 to plans 2 2x4 each side and 2 h2.5 each side -connect ufer ground to middle grounded bus bar -remove bonding screw from sub panel -tighten all anchor bolts throughout -complete water line under garage entry bath -sold block under cantilever basement E wall -stud pack under lvl basement E wall -missing steel columns in basement -anchor steel columns in basement and garage
Electrical Service Inspection Failed 9/21/2023 9/21/2023 09/21/2023
Misc
Corrective Action Required
09/11/2023
-Connect the GEC to the middle grounded bus bar. -remove the ufer ground connection at the sub panel -remove the bonding screw from the sub panel
All Rough Inspection - Residential Failed 11/14/2023 11/14/2023
Misc
Corrective Action Required
09/21/2023
-fire block S garage wall to ceiling space and furr down -fireblock N garage wall in furr downs -fire block E garage wall into furr down -roof boots to be installed and/or holes covered see bed -fire block pantry furr down -uncover covered rear deck for inspection -address all holes drilled through floor joist above hearth room and kitchen closer than 2” to one another add where missing -provide support and hold down for ridge above bed 4 to plans 2 2x4 each side and 2 h2.5 each side -tighten all anchor bolts throughout -complete water line under garage entry bath -sold block under cantilever basement E wall -stud pack under lvl basement E wall -missing steel columns in basement (have design professional address if not required)
Electrical Service Inspection Passed 11/14/2023 11/14/2023
Misc
Resolved
11/14/2023
-Connect the GEC to the middle grounded bus bar. -remove the year for ground connection at the sub panel -remove the bonding screw from the sub panel
All Rough Inspection - Residential Failed 11/14/2023 11/14/2023 11/14/2023
Misc
Corrective Action Required
11/14/2023
-fire block S garage wall to ceiling space and furr down -fireblock N garage wall in furr downs -fire block E garage wall into furr down -roof boots to be installed and/or holes covered see bed -fire block pantry furr down -uncover covered rear deck for inspection -address all holes drilled through floor joist above hearth room and kitchen closer than 2” to one another add where missing -provide support and hold down for ridge above bed 4 to plans 2 2x4 each side and 2 h2.5 each side -missing steel columns in basement (have design professional address if not required)
All Rough Inspection - Residential Failed 11/16/2023 11/16/2023 11/16/2023
Misc
Corrective Action Required
11/14/2023
-fire block S garage wall to ceiling space and furr down -uncover covered rear deck for inspection -address all holes drilled through floor joist above hearth room and kitchen closer than 2” to one another add where missing -missing steel columns in basement (have design professional address if not required) Okay to insulate
All Rough Inspection - Residential Failed 11/20/2023 11/20/2023 11/20/2023
Misc
Partial Correction
11/20/2023
-uncover covered rear deck for inspection -address all holes drilled through floor joist above hearth room and kitchen closer than 2” to one another add where missing Okay to insulate
All Rough Inspection - Residential Passed 12/4/2023 12/4/2023 12/04/2023
Misc
Partial Correction
11/20/2023
-uncover covered rear deck for inspection -address all holes drilled through floor joist above hearth room and kitchen closer than 2” to one another add where missing Okay to insulate
Piers/Caissons Inspection - Residential Failed 2/6/2024 2/6/2024 02/06/2024
Misc
Corrective Action Required
02/06/2024
(7) 24x36piers Not placed to plans
Driveway Inspection Partial 2/7/2024 2/7/2024 02/07/2024
Misc
Informational
02/07/2024
2-7-24 Dustin A, DW is formed and aggregate is compacted. Approved to pour.
Sidewalk Inspection Partial 2/7/2024 2/7/2024 02/07/2024
Misc
Informational
02/07/2024
2-7-24 Dustin A SW is formed and aggregate is compacted. Slopes are in compliance with city specs. Approved to pour.
Driveway Inspection Failed 2/21/2024 2/21/2024 02/20/2024
Misc
Informational
02/07/2024
2-7-24 Dustin A, DW is formed and aggregate is compacted. Approved to pour. 2-20-24 Dustin A, Dw is poured. Right panel does not meet city specs, Slopes are almost 3 percent. fail
Sidewalk Inspection Failed 2/21/2024 2/21/2024 02/20/2024
Misc
Corrective Action Required
02/20/2024
2-20-24 Dustin A, Sw has been poured, Sw is cracked in several panels. Will need to be replaced
Occupancy Inspection - Codes Residential Failed 4/8/2024 4/8/2024 04/08/2024
Misc
Corrective Action Required
04/08/2024
No further inspections until erosion control is in compliance -final grade and sod -splash blocks and sump pump discharge to extend 36” from foundation -un cover covered water meter -address pending sidewalk and driveway inspection -address failed pier inspection -fix all electrical in garage (receptacle not working, non GFCI double pull, receptacles not tamper proof) -address open j boxes in garage -garage door to be self closing and latching -smoke/CO outside bedrooms -complete hood install in kitchen -provide covers for boxes under kitchen shelves -address guard rail to have no gaps greater than 4” -address deck stairs top and bottom step no in compliance -handrail required at deck stairs -address all deck post to beam connections -provide proper hanger for deck triple joist -deck landing to extend 36” in the direction of travel -no flood lamp at rear -provide tamper resistant outlets -afci protection for (fridge, microwave & breakfast/rec) -provide GFCI protection for receptacles in basement or lable single pull receptacles as non GFCI -security screws at rear exterior door hinges and strike plates -
Plot Plan Inspection Failed 4/16/2024 04/16/2024
Misc
Corrective Action Required
04/16/2024
address grading on south side of lot Address piled dirt on neighbors fence
Driveway Inspection Passed 4/22/2024 4/22/2024 04/22/2024
Misc
Informational
02/20/2024
2-7-24 Dustin A, DW is formed and aggregate is compacted. Approved to pour. 2-20-24 Dustin A, Dw is poured. Right panel does not meet city specs, Slopes are almost 3 percent. fail 4-22-24 Dustin A, Panel has been replaced, and meets city spec
Sidewalk Inspection Passed 4/22/2024 04/22/2024
Misc
Informational
04/22/2024
4-22-24 Dustin A panel replaced.Passed
Sidewalk Inspection Passed 4/22/2024 04/22/2024
Occupancy Inspection - Codes Residential Failed 4/23/2024 4/23/2024 04/23/2024
Misc
Corrective Action Required
04/08/2024
No further inspections until erosion control is in compliance -final grade and sod (remove dirt off of neighbors fence) -splash blocks and sump pump discharge to extend 36” from foundation -un cover covered water meter -address pending sidewalk and driveway inspection -address failed pier inspection -fix all electrical in garage all Non gfci outlets to be single receptacle and labeled. Missing cover plate in outlet as well -address deck stairs bottom step not in compliance -handrail required at deck stairs (address mounting failing) -address all deck post to beam connections -provide proper hanger for deck triple joist -provide tamper resistant outlets throughout(all receptacles) -provide GFCI protection for receptacles in basement or lable single pull receptacles as non GFCi -
Occupancy Inspection - Codes Residential Not Ready 4/25/2024 4/25/2024 04/25/2024
Misc
Corrective Action Required
04/23/2024
No further inspections until erosion control is in compliance -final grade and sod (remove dirt off of neighbors fence) -splash blocks and sump pump discharge to extend 36” from foundation -un cover covered water meter -address pending sidewalk and driveway inspection -address failed pier inspection -fix all electrical in garage all Non gfci outlets to be single receptacle and labeled. Missing cover plate in outlet as well -address deck stairs bottom step not in compliance -handrail required at deck stairs (address mounting failing) -address all deck post to beam connections -provide proper hanger for deck triple joist -provide tamper resistant outlets throughout(all receptacles) -provide GFCI protection for receptacles in basement or lable single pull receptacles as non GFCi -
Misc
Corrective Action Required
04/25/2024
Erosion control, not in compliance inspection denied.
Erosion Control Inspection Residential Failed 4/25/2024 04/25/2024
Misc
Resolved
04/25/2024
Erosion control back in compliance.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
04/25/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
04/25/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Misc
Corrective Action Required
04/25/2024
Maintain erosion control around entire lot where needed. Remove dirt off of neighbors fence
Erosion Control Inspection Residential Failed 4/26/2024 4/26/2024 04/26/2024
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
04/25/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
04/25/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Misc
Corrective Action Required
04/25/2024
Maintain erosion control around entire lot where needed. Remove dirt off of neighbors fence
Occupancy Inspection - Codes Residential Failed 4/26/2024 4/26/2024 04/26/2024
Misc
Corrective Action Required
04/25/2024
No further inspections until erosion control is in compliance -final grade and sod (remove dirt off of neighbors fence) Provide fall protection at all areas around front stoop and stairs greater than 30” to ground 36” out -splash blocks and sump pump discharge to extend 36” from foundation -un cover covered water meter (ensure 14”-18” from meter top to ring well lid) -address failed pier inspection -handrail required at deck stairs (address height) -provide tamper resistant outlets throughout(all receptacles required by 4002.14)
Misc
Corrective Action Required
04/25/2024
Erosion control, not in compliance
Occupancy Inspection - Codes Residential Failed 4/29/2024 4/29/2024 04/26/2024
Misc
Corrective Action Required
04/26/2024
No further inspections until erosion control is in compliance -final grade and sod (remove dirt off of neighbors fence) Provide fall protection at all areas around front stoop and stairs greater than 30” to ground 36” out -splash blocks and sump pump discharge to extend 36” from foundation -un cover covered water meter (ensure 14”-18” from meter top to ring well lid) -address failed pier inspection -provide tamper resistant outlets throughout(all receptacles required by 4002.14) still not done OK to move homeowners items into garage
Misc
Corrective Action Required
04/26/2024
Erosion control, not in compliance
Occupancy Inspection - Codes Residential Ready for Temp CO 4/29/2024 4/29/2024 04/29/2024
Misc
Corrective Action Required
04/26/2024
No further inspections until erosion control is in compliance -final grade and sod (remove dirt off of neighbors fence) -Provide fall protection at all areas around front stoop and stairs greater than 30” to ground 36” out -splash blocks and sump pump discharge to extend 36” from foundation -un cover covered water meter (ensure 14”-18” from meter top to ring well lid) -address failed pier inspection (update plans to show pier placement )
Misc
Corrective Action Required
04/26/2024
Erosion control, not in compliance
Erosion Control Inspection Residential Failed 4/29/2024 4/29/2024 04/29/2024
DCM3 ESC REQUIRED 2 DAY
Resolved
04/29/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
04/29/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Misc
Resolved
04/29/2024
Maintain erosion control around entire lot where needed. Remove dirt off of neighbors fence
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
04/29/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Spoke with builder, erosion control will be in compliance 4/29/24 per Andy.
Miscellaneous Inspection Failed 5/22/2024 05/22/2024
Misc
Corrective Action Required
05/22/2024
EMAILED Kenny Mcfarland 2 times to ask him to contact the owner at 2409. Keith at 2409 has contacted me multiple times to correct the issue of silt and sod entering his yard and covereing the sod. i have seen no action from McFarland homes. MARK HARDING 05/22/2024 7:44 AM
Occupancy Inspection - Codes Residential Failed 5/29/2024 05/31/2024
Misc
Corrective Action Required
04/29/2024
No further inspections until erosion control is in compliance -final grade and sod (remove dirt off of neighbors fence) -Provide fall protection at all areas around front stoop and stairs greater than 30” to ground 36” out -splash blocks and sump pump discharge to extend 36” from foundation -un cover covered water meter (ensure 14”-18” from meter top to ring well lid) -address failed pier inspection (update plans to show pier placement )
Misc
Corrective Action Required
04/29/2024
Erosion control, not in compliance
Misc
Corrective Action Required
05/31/2024
reached out to builder to submit tco extension request with no response. "NOV" issued
Plot Plan Inspection Passed 6/21/2024 06/21/2024
Misc
Resolved
06/21/2024
address grading on south side of lot Address piled dirt on neighbors fence
Erosion Control Inspection Residential Failed 6/21/2024 06/21/2024
DCM3 ESC REQUIRED 2 DAY
Resolved
06/21/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Spoke with builder, erosion control will be in compliance 4/29/24 per Andy.
Misc
Corrective Action Required
06/21/2024
Erosion control still not in compliance. Appears Builder did pull some dirt away from neighbors fence.
Erosion Control Inspection Residential Failed 6/27/2024 6/27/2024 06/27/2024
Misc
Corrective Action Required
06/21/2024
Erosion control still not in compliance. Appears Builder did pull some dirt away from neighbors fence. 06/27/24- no changed have been made since last visit. See attached photos
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
06/27/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. 06/27/24- no changed have been made since last visit. See attached photos in permit
Occupancy Inspection - Codes Residential Failed 8/2/2024 8/2/2024 08/02/2024
Misc
Corrective Action Required
05/31/2024
-splash blocks and sump pump discharge to extend 36” from foundation -address failed pier inspection (update plans to show pier placement )
Misc
Resolved
08/02/2024
Erosion control, not in compliance
Misc
Resolved
08/02/2024
reached out to builder to submit tco extension request with no response. "NOV" issued
Occupancy Inspection - Codes Residential Failed 8/2/2024 08/02/2024
Misc
Corrective Action Required
08/02/2024
-splash blocks and sump pump discharge to extend 36” from foundation -address failed pier inspection (update plans to show pier placement )
Misc
Resolved
08/02/2024
Erosion control, not in compliance
Misc
Resolved
08/02/2024
reached out to builder to submit tco extension request with no response. "NOV" issued
Miscellaneous Inspection Failed 10/3/2024 10/03/2024
Misc
Resolved
10/03/2024
EMAILED Kenny Mcfarland 2 times to ask him to contact the owner at 2409. Keith at 2409 has contacted me multiple times to correct the issue of silt and sod entering his yard and covereing the sod. i have seen no action from McFarland homes. MARK HARDING 05/22/2024 7:44 AM
Misc
Informational
10/03/2024
SPOKE WITH BRENT ABOUT WARPING THIS UP, HE WILL TALK WITH ARCHITECT TO GET ISSUES RESOLVED. Mitchell Schwarz 10/03/2024 2:47 PM
Occupancy Inspection - Codes Residential Ready for Temp CO 10/3/2024 11/14/2024 11/14/2024
Misc
Corrective Action Required
08/02/2024
-splash blocks and sump pump discharge to extend 36” from foundation -address failed pier inspection (update plans to show pier placement )
Occupancy Inspection - Codes Residential Full C of O 12/19/2024 12/19/2024
Misc
Resolved
12/19/2024
-splash blocks and sump pump discharge to extend 36” from foundation -address failed pier inspection (update plans to show pier placement )
Documents & Images
Date Uploaded File Type Document Name
11/23/2022 permit app
11/23/2022 Excise tax
11/29/2022 Permit Codes Residential Plan Review
12/13/2022 Permit Codes Residential Plan Review
12/13/2022 Plot Plan approved plot plan
12/15/2022 Approved Plans APPROVED PLANS
12/15/2022 Permit Codes Residential Plan Review
12/15/2022 Permit DS Building Permit
12/15/2022 Receipt Receipt for transaction:2022-009533
01/13/2023 Letter INSPECTION SUMMARY
01/13/2023 Letter INSPECTION SUMMARY
01/13/2023 Letter Stop Work Order
01/30/2023 Letter INSPECTION SUMMARY
01/31/2023 Letter INSPECTION SUMMARY
02/03/2023 M L Crose 2405 SW River Trail Rd LSMO Eagle Creek Lot 662 Footing Inspection Report 12-16-22
02/07/2023 M L Crose 2405 SW River Trail Rd LSMO Eagle Creek Lot 662 Footing Inspection Report 12-16-22
02/15/2023 Letter INSPECTION SUMMARY
02/15/2023 Letter INSPECTION SUMMARY
02/15/2023 Letter INSPECTION SUMMARY
02/15/2023 Letter INSPECTION SUMMARY
03/14/2023 Letter INSPECTION SUMMARY
03/31/2023 Letter INSPECTION SUMMARY
04/07/2023 2405 SW River Trail Rd - garage & bsmnt & insul
06/02/2023 Letter INSPECTION SUMMARY
06/22/2023 Letter INSPECTION SUMMARY
07/20/2023 Letter INSPECTION SUMMARY
07/20/2023 Letter INSPECTION SUMMARY
07/20/2023 Letter INSPECTION SUMMARY
07/20/2023 Letter INSPECTION SUMMARY
07/26/2023 Letter INSPECTION SUMMARY
08/01/2023 Letter INSPECTION SUMMARY
08/08/2023 Letter Stop Work Order
08/15/2023 IMG_0870
08/15/2023 IMG_0875
08/15/2023 IMG_0876
08/29/2023 Receipt Receipt for transaction:2023-006709
08/30/2023 Letter INSPECTION SUMMARY
09/05/2023 Letter INSPECTION SUMMARY
09/11/2023 Letter INSPECTION SUMMARY
09/11/2023 Letter INSPECTION SUMMARY
09/18/2023 Receipt Receipt for transaction:2023-007144
09/21/2023 Letter INSPECTION SUMMARY
09/21/2023 Letter INSPECTION SUMMARY
09/21/2023 Letter INSPECTION SUMMARY
10/20/2023 2405 SW River Trail Rd - framing & strapping & waterline
11/14/2023 Letter INSPECTION SUMMARY
11/14/2023 Letter INSPECTION SUMMARY
11/14/2023 Letter INSPECTION SUMMARY
11/16/2023 Letter INSPECTION SUMMARY
11/20/2023 Letter INSPECTION SUMMARY
12/04/2023 Letter INSPECTION SUMMARY
02/06/2024 Letter INSPECTION SUMMARY
02/07/2024 Letter INSPECTION SUMMARY
02/07/2024 Letter INSPECTION SUMMARY
02/20/2024 Letter INSPECTION SUMMARY
02/20/2024 Letter INSPECTION SUMMARY
02/20/2024 Letter INSPECTION SUMMARY
02/20/2024 Letter INSPECTION SUMMARY
04/08/2024 Letter INSPECTION SUMMARY
04/16/2024 Letter INSPECTION SUMMARY
04/22/2024 Letter INSPECTION SUMMARY
04/22/2024 Letter INSPECTION SUMMARY
04/22/2024 Letter INSPECTION SUMMARY
04/23/2024 Letter INSPECTION SUMMARY
04/24/2024 scan0346
04/25/2024 Letter INSPECTION SUMMARY
04/25/2024 Letter INSPECTION SUMMARY
04/26/2024 Letter INSPECTION SUMMARY
04/26/2024 Letter INSPECTION SUMMARY
04/26/2024 Letter INSPECTION SUMMARY
04/29/2024 Letter INSPECTION SUMMARY
04/29/2024 Certificate/License Codes Temporary Certificate of Occupancy
04/29/2024 Receipt Receipt for transaction:2024-002726
05/22/2024 Letter INSPECTION SUMMARY
05/31/2024 Letter INSPECTION SUMMARY
05/31/2024 Letter Codes 10 Day Letter
06/12/2024 Eagle Creek 15th Lot 662 AB 24_0611
06/12/2024 Plot Plan approved as graded plot plan
06/21/2024 Letter INSPECTION SUMMARY
06/21/2024 Letter INSPECTION SUMMARY
06/27/2024 IMG_1235
06/27/2024 IMG_1236
06/27/2024 Letter INSPECTION SUMMARY
07/02/2024 Letter Codes 10 Day Letter
07/02/2024 Certificate/License Codes Temporary Certificate of Occupancy
07/02/2024 Certificate/License Codes Temporary Certificate of Occupancy
07/02/2024 Receipt Receipt for transaction:2024-005436
08/02/2024 Letter INSPECTION SUMMARY
08/02/2024 Letter INSPECTION SUMMARY
08/02/2024 Letter INSPECTION SUMMARY
10/15/2024 Letter Codes 10 Day Letter
10/15/2024 Certificate/License Codes Temporary Certificate of Occupancy
10/15/2024 Certificate/License Codes Temporary Certificate of Occupancy
10/15/2024 Receipt Receipt for transaction:2024-008346
11/19/2024 Certificate/License Codes Temporary Certificate of Occupancy
11/19/2024 Receipt Receipt for transaction:2024-009028
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home