Permit Application Status

PRCOM20250089


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRCOM20250089
Building Permit - Commercial
Issued - Partial
NEW COMMERCIAL
REUNION AT BLACKWELL - NEW CLUBHOUSE Mike Weisenborn 03/31/2025 9:56 AM - Foundation and underlsab plumbing only released at this time. Substantial completion on the santiary and water before private connections can be made. Full access and live hydrants required prior to release of vertical construction.
01/08/2025
08/06/2025
Locations
Contacts
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
RED DOG ELECTRIC SERVICES, Address:PO BOX 1, Phone:(913) 208-4816  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
COLLINS WEBB ARCHITECTURE LLC, Address:307 SW MARKET ST, Unit B, Phone:(816) 249-2270  
Avital Homes, LLC, Address:7500 W 151st Street, #23100, Phone:(816) 914-7128  
Doug Jenson - Avital Homes, Phone:(816) 266-0685  
Reviews
Review Type Outcome Est. Completion Date Completed
Building Plan Review Approved with Conditions 02/25/2025 03/24/2025
Joe Frogge
IBC 502.1 - Address Identification
Corrective Action Required
02/18/2025

2018 IBC 502.1 Address identification. New and existing buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property. Address identification characters shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be a minimum of 4 inches high with a minimum stroke width of ½ inch. Where required by the fire code official, address identification shall be provided in additional approved locations to facilitate emergency response. Where access is by means of a private road and the building address cannot be viewed from the public way, a monument, pole or other approved sign or means shall be used to identify the structure. Address identification shall be maintained. Action required: Comment is informational. 2/4/2025 - Acknowledged in letter.
Misc
Resolved
02/24/2025

This review is for clubhouse and maintenance garage only. (some townhome drawings are in the plan set) Action required: Comment is informational. Submit application form for garage to get that process started. 2/4/2025 - Acknowledged in letter.
Engineered truss package
Corrective Action Required
02/18/2025

Copies of the engineered truss package were not provided at the time of permit application. Action required: Comment is informational. Deferred per request. 2/4/2025 - Acknowledged in letter.
IBC 1103.1 Where required - accessibility
Resolved
02/21/2025

2018 IBC 1103.1 Where required. Sites, buildings, structures, facilities, elements and spaces, temporary or permanent, shall be accessible to persons with physical disabilities. Action required: Work area to be fully accessible. Provide 60" turning space and label cabinetry as maximum 34" tall. 2/4/2025 - Work Area (between Leasing & Manager) still not accessible. Revise.
IPC 604.8 Water pressure reducing valve
Corrective Action Required
02/18/2025

2018 IPC 604.8 Water Pressure reducing valve or regulator. Where water pressure within a building exceeds 80 psi static, an approved water-pressure reducing valve conforming to ASSE 1003 or CSA B356 with strainer shall be installed to reduce the pressure in the building water distribution piping to not greater than 80 psi static. Action required: Provide pressure reducing valve at water entry. (Our Water Department requires PRV installation in all locations regardless of pressure) To be field verified
Miscellaneous Correction
Corrective Action Required
02/24/2025

Informational notes for townhome review. Items not found in plans that will be verified during inspections. - Doors between garages and living units must be 20 minute fire rated and be self closing. - Wall insulation to be minimum R-13. - Ceiling insulation to be minimum R-30. (or R-19 if part of roof assembly)
Miscellaneous Correction
Corrective Action Required
04/03/2025

Foundation and underlsab plumbing only released at this time. Substantial completion on the santiary and water before private connections can be made. Full access and live hydrants required prior to release of vertical construction.
Fire Plan Review Approved with Conditions 02/25/2025 02/24/2025
Joe Frogge
Portable fire extinguishers - general
Corrective Action Required
02/18/2025

2018 IFC 906.2- General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Information Only
Licensed Contractors Approved 02/25/2025 02/21/2025
Joe Frogge
Fire Plan Review Approved with Conditions 02/05/2025 02/05/2025
Craig Hill
Type I hood - Where required
Resolved
02/05/2025

2018 IFC 609.2- Where required. A Type I hood shall be installed at or above all commercial cooking appliances and domestic cooking appliances used for commercial purposes that produce grease vapors. Action Required: Clarify use of "kitchen." A Type I hood may be required.
Portable fire extinguishers - general
Corrective Action Required
01/29/2025

2018 IFC 906.2- General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Information Only
Building Plan Review Rejected 02/05/2025 02/04/2025
Joe Frogge
IBC 502.1 - Address Identification
Corrective Action Required
01/29/2025

2018 IBC 502.1 Address identification. New and existing buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property. Address identification characters shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be a minimum of 4 inches high with a minimum stroke width of ½ inch. Where required by the fire code official, address identification shall be provided in additional approved locations to facilitate emergency response. Where access is by means of a private road and the building address cannot be viewed from the public way, a monument, pole or other approved sign or means shall be used to identify the structure. Address identification shall be maintained. Action required: Comment is informational. 2/4/2025 - Acknowledged in letter.
Misc
Corrective Action Required
01/29/2025

This review is for clubhouse and maintenance garage only. (some townhome drawings are in the plan set) Action required: Comment is informational. Submit application form for garage to get that process started. 2/4/2025 - Acknowledged in letter.
Engineered truss package
Corrective Action Required
01/29/2025

Copies of the engineered truss package were not provided at the time of permit application. Action required: Comment is informational. Deferred per request. 2/4/2025 - Acknowledged in letter.
Miscellaneous Correction
Resolved
02/04/2025

Clarify use of "kitchen." If the oven will be used to cook for the public it needs a Type I hood and Jackson County Health Department approval. Assuming all food is prepared off-site and the oven is only for warming purposes, Actions required: - Add a note designating oven as warming only. - Provide permanent signage at the oven with similar verbiage. - Do not use the title of "kitchen."
IBC 1103.1 Where required - accessibility
Corrective Action Required
01/29/2025

2018 IBC 1103.1 Where required. Sites, buildings, structures, facilities, elements and spaces, temporary or permanent, shall be accessible to persons with physical disabilities. Action required: Work area to be fully accessible. Provide 60" turning space and label cabinetry as maximum 34" tall. 2/4/2025 - Work Area (between Leasing & Manager) still not accessible. Revise.
IBC 1208.2 Attic spaces
Resolved
02/04/2025

2018 IBC 1208.2 Attic spaces. An opening not less than 20 inches by 30 inches shall be provided to any attic area having a clear height of over 30 inches. Clear headroom of not less than 30 inches shall be provided in the attic space at or above the access opening. Action required: Provide compliant access to attic.
Misc
Resolved
02/04/2025

MEP designs not found in submittal. Action required: Provide complete MEP designs. Must be sealed/signed by MO State architect or engineer.
Planning - Screening of ground mounted equipment
Resolved
02/04/2025

Unified Development Ordinance Article 8, Section 8.180.F Ground mounted equipment – Ground mounted equipment shall be totally screened from view by landscaping or masonry wall up to a height of the units to be screened. Action required: Make needed corrections to drawings that provide details as to how mechanical equipment (clubhouse condensing unit) will be screened from all 4 sides per referenced UDO section.
IBC 1209.2 Finish materials
Resolved
02/04/2025

2018 IBC 1209.2 Finish Materials. Walls, Floors and partitions in toilet and bathrooms shall comply with Sections 209.2.1 through 1209.2.4. 2018 1209.2.1 Floors and wall bases. In other than dwelling units, toilet, bathing and shower room floor finish materials shall have a smooth, hard, nonabsorbent surface. The intersections of such floors with walls shall have a smooth, hard, nonabsorbent vertical base that extends upward onto the walls not less than 4 inches. 2018 1209.2.2 Walls and partitions. Walls and partitions within 2 feet of service sinks, urinals and water closets shall have a smooth, hard, nonabsorbent surface, to a height of not less than 4 feet above the floor, and except for structural elements, the materials used in such walls shall be of a type that is not adversely affected by moisture. (See code section for possible exceptions.) Action required: Specify compliant wall finishes at water closets, urinals, and mop sink.
IPC 604.8 Water pressure reducing valve
Corrective Action Required
02/04/2025

2018 IPC 604.8 Water Pressure reducing valve or regulator. Where water pressure within a building exceeds 80 psi static, an approved water-pressure reducing valve conforming to ASSE 1003 or CSA B356 with strainer shall be installed to reduce the pressure in the building water distribution piping to not greater than 80 psi static. Action required: Provide pressure reducing valve at water entry. (Our Water Department requires PRV installation in all locations regardless of pressure)
Licensed Contractors Approved 02/05/2025 02/04/2025
Joe Frogge
LC - General Contractor
Resolved
02/04/2025

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawful for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances. Action required: Either a Class A or Class B license is required. Provide the company name of the licensed general contractor and the name, email address & phone number for the on-site contact. (Avital is currently a Class C which is residential only)
Final Development Plan Review Approved 01/23/2025 01/30/2025
Mike Weisenborn
Fire Plan Review Rejected 01/23/2025 01/23/2025
Craig Hill
Miscellaneous Correction
Corrective Action Required
01/21/2025

MEP designs not found in submittal. Action required: Provide complete MEP designs to show emergency and exit lighting.
Type I hood - Where required
Corrective Action Required
01/21/2025

2018 IFC 609.2- Where required. A Type I hood shall be installed at or above all commercial cooking appliances and domestic cooking appliances used for commercial purposes that produce grease vapors. Action Required: Clarify use of "kitchen." A Type I hood may be required.
Portable fire extinguishers - general
Corrective Action Required
01/21/2025

2018 IFC 906.2- General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Information Only
Portable fire extinguishers - conspicuous locations
Corrective Action Required
01/21/2025

2018 IFC 906.5- Conspicuous location. Portable fire extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. Action Required: Provide fire extinguishers in accordance with IFC 2018
Building Plan Review Rejected 01/23/2025 01/21/2025
Joe Frogge
IBC 502.1 - Address Identification
Corrective Action Required
01/08/2025

2018 IBC 502.1 Address identification. New and existing buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property. Address identification characters shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be a minimum of 4 inches high with a minimum stroke width of ½ inch. Where required by the fire code official, address identification shall be provided in additional approved locations to facilitate emergency response. Where access is by means of a private road and the building address cannot be viewed from the public way, a monument, pole or other approved sign or means shall be used to identify the structure. Address identification shall be maintained. Action required: Comment is informational.
Misc
Corrective Action Required
01/21/2025

This review is for clubhouse and maintenance garage only. (some townhome drawings are in the plan set) Action required: Comment is informational. Submit application form for garage to get that process started.
Engineered truss package
Corrective Action Required
01/21/2025

Copies of the engineered truss package were not provided at the time of permit application. Action required: Comment is informational. Deferred per request.
Miscellaneous Correction
Corrective Action Required
01/21/2025

Clarify use of "kitchen." If the oven will be used to cook for the public it needs a Type I hood and Jackson County Health Department approval. Assuming all food is prepared off-site and the oven is only for warming purposes, Actions required: - Add a note designating oven as warming only. - Provide permanent signage at the oven with similar verbiage. - Do not use the title of "kitchen."
IBC 1103.1 Where required - accessibility
Corrective Action Required
01/21/2025

2018 IBC 1103.1 Where required. Sites, buildings, structures, facilities, elements and spaces, temporary or permanent, shall be accessible to persons with physical disabilities. Action required: Work area to be fully accessible. Provide 60" turning space and label cabinetry as maximum 34" tall.
IBC 1208.2 Attic spaces
Corrective Action Required
01/21/2025

2018 IBC 1208.2 Attic spaces. An opening not less than 20 inches by 30 inches shall be provided to any attic area having a clear height of over 30 inches. Clear headroom of not less than 30 inches shall be provided in the attic space at or above the access opening. Action required: Provide compliant access to attic.
Misc
Corrective Action Required
01/21/2025

MEP designs not found in submittal. Action required: Provide complete MEP designs. Must be sealed/signed by MO State architect or engineer.
Planning - Screening of ground mounted equipment
Corrective Action Required
01/21/2025

Unified Development Ordinance Article 8, Section 8.180.F Ground mounted equipment – Ground mounted equipment shall be totally screened from view by landscaping or masonry wall up to a height of the units to be screened. Action required: Make needed corrections to drawings that provide details as to how mechanical equipment (clubhouse condensing unit) will be screened from all 4 sides per referenced UDO section.
IBC 1209.2 Finish materials
Corrective Action Required
01/21/2025

2018 IBC 1209.2 Finish Materials. Walls, Floors and partitions in toilet and bathrooms shall comply with Sections 209.2.1 through 1209.2.4. 2018 1209.2.1 Floors and wall bases. In other than dwelling units, toilet, bathing and shower room floor finish materials shall have a smooth, hard, nonabsorbent surface. The intersections of such floors with walls shall have a smooth, hard, nonabsorbent vertical base that extends upward onto the walls not less than 4 inches. 2018 1209.2.2 Walls and partitions. Walls and partitions within 2 feet of service sinks, urinals and water closets shall have a smooth, hard, nonabsorbent surface, to a height of not less than 4 feet above the floor, and except for structural elements, the materials used in such walls shall be of a type that is not adversely affected by moisture. (See code section for possible exceptions.) Action required: Specify compliant wall finishes at water closets, urinals, and mop sink.
Licensed Contractors Rejected 01/23/2025 01/21/2025
Joe Frogge
LC - General Contractor
Corrective Action Required
01/21/2025

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawful for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances. Action required: Either a Class A or Class B license is required. Provide the company name of the licensed general contractor and the name, email address & phone number for the on-site contact. (Avital is currently a Class C which is residential only)
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for New Commercial $1,800.00 $1,800.00 Paid 04/03/2025
8331401-Water Tap Fee $10,595.00 $10,595.00 Paid 04/03/2025
8350015-Water Meter Fee $1,066.76 $1,066.76 Paid 04/03/2025
8331507-Sanitary Sewer Development Fee $6,101.00 $6,101.00 Paid 04/03/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Pending
Piers/Caissons Inspection - Commercial Pending
Underslab Plumbing Inspection - Commercial Pending
Sewer Service Inspection Pending
Verify Final Inspection Status - New Com Development Pending 7/2/2025
Footing Inspection - Commercial Passed 4/28/2025 4/28/2025 04/28/2025
Documents & Images
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home