Review Type |
Outcome |
Est. Completion Date |
Completed |
Engineering Review - Water
|
No Comments
|
05/06/2025
|
05/06/2025
|
|
Gene Williams, P.E.
|
|
|
Engineering Review - Sanitary
|
No Comments
|
04/30/2025
|
04/30/2025
|
|
Gene Williams, P.E.
|
|
|
Traffic Review - Streets
|
Approved with Conditions
|
02/28/2025
|
02/28/2025
|
|
Erin Ralovo
|
|
Miscellaneous Correction
Corrective Action Required
After email conversations with staff and the developer, it has been agreed that a design for a 3-legged intersection will be sufficient submittal for permit. The design must accomodate the improvements required by Ovation so that none of the equipment will need to be moved at a later date.
|
|
|
Traffic Review - Streets
|
Approved with Conditions
|
02/06/2025
|
02/05/2025
|
|
Erin Ralovo
|
|
Misc
Corrective Action Required
Traffic staff gives conditional approval of the Public Infrastructure plans. MoDOT approval of the plans for the signal at the intersection of MO 150 and Sunset Ridge Drive will be required before any substantial completion will be allowed on the project.
|
|
|
Traffic Review - Streets
|
Corrections
|
01/24/2025
|
01/24/2025
|
|
Erin Ralovo
|
|
Misc
Improvements along 150 HWY should be included with this submittal. MoDOT will have to give final approval but the staff will need to review as well.
Staff is in discussions with MODOT about how to procees with the traffic signal required at Sunset Ridge. Final approval will not be given before MoDOT advises how to proceed.
|
|
Miscellaneous Correction
The merge lane for northbound traffic seems unnecessary. A single lane with a wider island may be a better fit.
Striping for the extra widening should be yellow if on the lfet hand side of the roadway.
|
|
Miscellaneous Correction
Corrective Action Required
Staff has spoken with MoDOT about the planned signal at Sunset Ridge and it has been determined that the signal will be required before occupancy of the project. Plans should be submitted to MoDOT for review and approval must be given to the City before approval is given on these plans with the understanding that construction is not required until a later time.
|
|
|
Engineering Review - Sanitary
|
Approved with Conditions
|
01/24/2025
|
01/23/2025
|
|
Gene Williams, P.E.
|
|
Miscellaneous Correction
Corrective Action Required
An MDNR permit shall be required for this project. Informational comment.
|
|
|
Engineering Review - Water
|
Approved with Conditions
|
01/24/2025
|
01/23/2025
|
|
Gene Williams, P.E.
|
|
Miscellaneous Correction
There are multiple points on the water line where pipe deflection curvature of radius is less than 1200 ft. Show locations of all fittings needed to keep the deflection curvature greater than 1200 feet. Corrections required.
|
|
Miscellaneous Correction
Sheet 4: Station 10+00 is missing 4 gate valves at the cross. Correction required.
|
|
Miscellaneous Correction
Sheet 4: Station 12+21 is missing one (1) gate valve on the south side of the tee. Correction required.
|
|
Miscellaneous Correction
Sheet 5: Extend water line B and move the hydrant to the next property line so the service line for lot 25 can be connected without crossing the property line. Correction required.
|
|
Miscellaneous Correction
Additional fire hydrant is required on Fern Ln. to the south of 26th St. Correction required.
|
|
Miscellaneous Correction
Corrective Action Required
MDNR construction permit shall be required prior to formal approval. Informational comment.
|
|
|
Engineering Review - Street and Storm
|
Approved with Conditions
|
01/24/2025
|
01/23/2025
|
|
Gene Williams, P.E.
|
|
Miscellaneous Correction
S denotes "slab" basement on the Master Drainage Plan. Is this what you intend? Assuming you wish to change this designation to represent a "standard" basement. Informational comment, and corrections required if appropriate. Otherwise, only slab on grade homes will be allowed without special permission from the designer.
|
|
Miscellaneous Correction
Cost estimate required prior to formal approval. Informational comment.
|
|
|
Engineering Review - Water
|
Corrections
|
12/10/2024
|
12/11/2024
|
|
Gene Williams, P.E.
|
|
Miscellaneous Correction
Sheet C201: Change Line 2-FF to “PROP 12” WATER". Correction required.
|
|
Miscellaneous Correction
Sheet C202: The limits of the casing pipe appear to extend to the 12” water main running along HWY 150 at Sta. 1+15.00. The casing pipe should start north of the butterfly valve. Correction required.
|
|
Miscellaneous Correction
Sheet C202: Three (3) valves are required at all tees. There should be three valves installed at the tee at Sta. 1+00. Correction required.
|
|
Miscellaneous Correction
Sheet C204: Why move the 12” water main to the west side of Sunset Ridge? There is room to place the 12” water main in the 15’ UE on the east side of Sunset Ridge, and avoids jogs and reducers. Correction required.
|
|
Miscellaneous Correction
Overview Sheet: Label all street names on overview sheet. Correction required.
|
|
Miscellaneous Correction
Overview Sheet C201: Line FF is mislabeled as an 8 inch line. This should be a 12 inch line. Correction required.
|
|
Miscellaneous Correction
Sheet C202: Gate valves are desired for 12 inch lines. Butterfly valves should only be used for valves larger than 12 inch. Correction required.
|
|
Miscellaneous Correction
An MDNR permit shall be required prior to formal approval. Informational comment.
|
|
|
Engineering Review - Sanitary
|
Approved with Conditions
|
12/10/2024
|
12/10/2024
|
|
Gene Williams, P.E.
|
|
Miscellaneous Correction
Label all street names on the general overview sheet. Correction required.
|
|
Miscellaneous Correction
Please label existing manholes with the official City manhole number. Connection point of line D is 58-063. Line H is 58-067. Line B is 58-051. Correction required.
|
|
Miscellaneous Correction
Relocate manhole H-3 to not exceed 400 feet in length from the next manhole H-4. Correction required.
|
|
Miscellaneous Correction
Eliminate manhole H-2 and direct connect to existing City manhole 58-067. Correction required.
|
|
Miscellaneous Correction
Line B appears to be located in an easement that is too narrow. Required width is twice the depth assuming the line is centered within the easement. Correction required on plans and plat.
|
|
Miscellaneous Correction
Corrective Action Required
An MDNR permit shall be required for this project. Informational comment.
|
|
|
Engineering Review - Street and Storm
|
Corrections
|
12/10/2024
|
12/10/2024
|
|
Gene Williams, P.E.
|
|
Miscellaneous Correction
Stormwater manhole lid shall meet new requirement for lettering. Standard detail to be sent separate from this applicant letter. Corrections required.
|
|
Miscellaneous Correction
Sheet C051: All asphaltic concrete to be KCMMB mix. Correction required.
|
|
Miscellaneous Correction
Typical Pavement Section Views: Recommend a re-review by the engineer for the most up-to-date design criteria for residential local access, and residential collector. Design criteria is shown on Table LS-2 of the most up-to-date version of the table within Section 5200 of the Lee's Summit Design and Construction Manual. Some criteria became less stringent, others more. Most changes are related to aggregate thickness, which mostly were decreased from the past version of the Design and Construction Manual. Correction required.
|
|
Miscellaneous Correction
Recommend removing the light blue, blue, and purple phasing lines from Sheet C101. These plans are for Cobey Creek 2nd Plat, and Sheet C101 should concentrate on the 2nd plat/phase rather than showing the entire phasing of the project. Recommend "graying-out". Correction required.
|
|
Miscellaneous Correction
S denotes "slab" basement on the Master Drainage Plan. Is this what you intend? Assuming you wish to change this designation to represent a "standard" basement. Informational comment, and corrections required if appropriate. Otherwise, only slab on grade homes will be allowed without special permission from the designer.
|
|
Miscellaneous Correction
Sheet C501: A cross-hatched area representing what is shown in the legend to be a drainage swale does not appear to make sense. Correction required.
|
|
Miscellaneous Correction
Offsite existing elevation contours shown on Sheet C104 do not appear to match what is shown on Sheet C500 "Inlet Drainage Area". Reviewing Sheet C500, it would appear additional inlets and pipe are needed. Reviewing other sheets, it would appear this is not necessary. Evaluate and correct if necessary.
|
|
Miscellaneous Correction
There are mid-block crossings shown on the plans with 1.5% maximum cross-slope callouts. This may introduce a bump in the road, and is not desired. Mid-block crossings can match existing grade as long as the running slope does not exceed 5%. Evaluate and revise as appropriate.
|
|
Miscellaneous Correction
The existing north detention basin shall include a detailed design showing how the basin will be converted to a sediment basin. This shall include any skimmer(s) to be installed, sizing of the skimmers, installation of the skimmers, block-offs of the existing outlet structure water quality orifices, etc. Correction required.
|
|
Miscellaneous Correction
A note shall be provided on the erosion and sediment control plan in bold lettering that states "SEDIMENT BASIN CONVERSION TO OCCUR PRIOR TO ANY CONSTRUCTION ACTIVITIES" or equivalent language. Correction required.
|
|
Miscellaneous Correction
Master Drainage Plan: Label finished elevation contours to the extent they can be understood (i.e., not all need be labeled, only to the extent that others can be interpolated). Correction required.
|
|
Miscellaneous Correction
Sheet C400: Notes on bottom left hand corner are incomplete with the "xxxx" designation. Correction required.
|
|
Miscellaneous Correction
Sheet C401: The truncated domes on bottom right exceed the maximum 5.0 feet distance to back of curb. Correction required.
|
|
Miscellaneous Correction
ADA-accessible routes across intersections: Ensure non-stop controlled intersections match road grade (max 5%) to eliminate any bump (i.e., change in grade) at the non-stop controlled intersection. It appears all ADA-accessible routes across intersections were designed with 1.5% cross-slope, which is not desireable for non-stop controlled intersections. Correction required.
|
|
Miscellaneous Correction
Many of the notes for the ADA-accessible routes across streets and intersections state "5.00 ft. max". This should be called out as 5.00 feet, not "max". Correction required.
|
|
Miscellaneous Correction
SWPPP is required prior to formal approval. Correction required.
|
|
Miscellaneous Correction
Corrective Action Required
Cost estimate required prior to formal approval. Informational comment.
|
|
|
Traffic Review - Streets
|
Corrections
|
12/10/2024
|
12/09/2024
|
|
Erin Ralovo
|
|
Misc
Corrective Action Required
Improvements along 150 HWY should be included with this submittal. MoDOT will have to give final approval but the staff will need to review as well.
Staff is in discussions with MODOT about how to procees with the traffic signal required at Sunset Ridge. Final approval will not be given before MoDOT advises how to proceed.
|
|
Miscellaneous Correction
Speed Limit sign at Sta. 4+28.73 should be 25 MPH not 15.
|
|
Miscellaneous Correction
Corrective Action Required
The merge lane for northbound traffic seems unnecessary. A single lane with a wider island may be a better fit.
Striping for the extra widening should be yellow if on the lfet hand side of the roadway.
|
|
Miscellaneous Correction
Divided Road sign at Sta. 5+69.76 should be a Keep Right (R4-7).
|
|
Miscellaneous Correction
Stop Sign at Sta. 6+72.45 should be removed.
|
|
Miscellaneous Correction
Stop signs on side streets should also have street name signs (D-3)
|
|
Miscellaneous Correction
Both Sta. 1+83.32 4" solid white are pointing to the wrong lines.
|
|
Miscellaneous Correction
The striped out lane should have 24" chevrons not 18".
|
|
Miscellaneous Correction
The through arrows going NB are not needed.
|
|
Miscellaneous Correction
Corrective Action Required
Staff has spoken with MoDOT about the planned signal at Sunset Ridge and it has been determined that the signal will be required before occupancy of the project. Plans should be submitted to MoDOT for review and approval must be given to the City before approval is given on these plans with the understanding that construction is not required until a later time.
|
|
|
Engineering Review - Water
|
Corrections
|
10/30/2024
|
10/30/2024
|
|
Gene Williams, P.E.
|
|
Miscellaneous Correction
Corrective Action Required
Sheet C201: Change Line 2-FF to “PROP 12” WATER". Correction required.
|
|
Miscellaneous Correction
Corrective Action Required
Sheet C202: The limits of the casing pipe appear to extend to the 12” water main running along HWY 150 at Sta. 1+15.00. The casing pipe should start north of the butterfly valve. Correction required.
|
|
Miscellaneous Correction
Corrective Action Required
Sheet C202: Three (3) valves are required at all tees. There should be three valves installed at the tee at Sta. 1+00. Correction required.
|
|
Miscellaneous Correction
Corrective Action Required
Sheet C204: Why move the 12” water main to the west side of Sunset Ridge? There is room to place the 12” water main in the 15’ UE on the east side of Sunset Ridge, and avoids jogs and reducers. Correction required.
|
|
Miscellaneous Correction
Corrective Action Required
Overview Sheet: Label all street names on overview sheet. Correction required.
|
|
Miscellaneous Correction
Corrective Action Required
Overview Sheet C201: Line FF is mislabeled as an 8 inch line. This should be a 12 inch line. Correction required.
|
|
Miscellaneous Correction
Corrective Action Required
Sheet C202: Gate valves are desired for 12 inch lines. Butterfly valves should only be used for valves larger than 12 inch. Correction required.
|
|
Miscellaneous Correction
Corrective Action Required
An MDNR permit shall be required prior to formal approval. Informational comment.
|
|
|
Engineering Review - Sanitary
|
Corrections
|
10/30/2024
|
10/30/2024
|
|
Gene Williams, P.E.
|
|
Miscellaneous Correction
Corrective Action Required
Label all street names on the general overview sheet. Correction required.
|
|
Miscellaneous Correction
Corrective Action Required
Please label existing manholes with the official City manhole number. Connection point of line D is 58-063. Line H is 58-067. Line B is 58-051. Correction required.
|
|
Miscellaneous Correction
Corrective Action Required
Relocate manhole H-3 to not exceed 400 feet in length from the next manhole H-4. Correction required.
|
|
Miscellaneous Correction
Corrective Action Required
Eliminate manhole H-2 and direct connect to existing City manhole 58-067. Correction required.
|
|
Miscellaneous Correction
Corrective Action Required
Line B appears to be located in an easement that is too narrow. Required width is twice the depth assuming the line is centered within the easement. Correction required on plans and plat.
|
|
Miscellaneous Correction
Corrective Action Required
An MDNR permit shall be required for this project. Informational comment.
|
|
|
Engineering Review - Street and Storm
|
Corrections
|
10/30/2024
|
10/30/2024
|
|
Gene Williams, P.E.
|
|
Miscellaneous Correction
Corrective Action Required
Stormwater manhole lid shall meet new requirement for lettering. Standard detail to be sent separate from this applicant letter. Corrections required.
|
|
Miscellaneous Correction
Corrective Action Required
Sheet C051: All asphaltic concrete to be KCMMB mix. Correction required.
|
|
Miscellaneous Correction
Corrective Action Required
Typical Pavement Section Views: Recommend a re-review by the engineer for the most up-to-date design criteria for residential local access, and residential collector. Design criteria is shown on Table LS-2 of the most up-to-date version of the table within Section 5200 of the Lee's Summit Design and Construction Manual. Some criteria became less stringent, others more. Most changes are related to aggregate thickness, which mostly were decreased from the past version of the Design and Construction Manual. Correction required.
|
|
Miscellaneous Correction
Corrective Action Required
Recommend removing the light blue, blue, and purple phasing lines from Sheet C101. These plans are for Cobey Creek 2nd Plat, and Sheet C101 should concentrate on the 2nd plat/phase rather than showing the entire phasing of the project. Recommend "graying-out". Correction required.
|
|
Miscellaneous Correction
Corrective Action Required
Master Drainage Plan was missing the basement type for each lot (e.g., walkout, daylight, or standard). Correction required.
|
|
Miscellaneous Correction
Corrective Action Required
Sheet C501: A cross-hatched area representing what is shown in the legend to be a drainage swale does not appear to make sense. Correction required.
|
|
Miscellaneous Correction
Corrective Action Required
Offsite existing elevation contours shown on Sheet C104 do not appear to match what is shown on Sheet C500 "Inlet Drainage Area". Reviewing Sheet C500, it would appear additional inlets and pipe are needed. Reviewing other sheets, it would appear this is not necessary. Evaluate and correct if necessary.
|
|
Miscellaneous Correction
Corrective Action Required
There are mid-block crossings shown on the plans with 1.5% maximum cross-slope callouts. This may introduce a bump in the road, and is not desired. Mid-block crossings can match existing grade as long as the running slope does not exceed 5%. Evaluate and revise as appropriate.
|
|
Miscellaneous Correction
Corrective Action Required
The existing north detention basin shall include a detailed design showing how the basin will be converted to a sediment basin. This shall include any skimmer(s) to be installed, sizing of the skimmers, installation of the skimmers, block-offs of the existing outlet structure water quality orifices, etc. Correction required.
|
|
Miscellaneous Correction
Corrective Action Required
A note shall be provided on the erosion and sediment control plan in bold lettering that states "SEDIMENT BASIN CONVERSION TO OCCUR PRIOR TO ANY CONSTRUCTION ACTIVITIES" or equivalent language. Correction required.
|
|
Miscellaneous Correction
Corrective Action Required
Master Drainage Plan: Label finished elevation contours to the extent they can be understood (i.e., not all need be labeled, only to the extent that others can be interpolated). Correction required.
|
|
Miscellaneous Correction
Corrective Action Required
Sheet C400: Notes on bottom left hand corner are incomplete with the "xxxx" designation. Correction required.
|
|
Miscellaneous Correction
Corrective Action Required
Sheet C401: The truncated domes on bottom right exceed the maximum 5.0 feet distance to back of curb. Correction required.
|
|
Miscellaneous Correction
Corrective Action Required
ADA-accessible routes across intersections: Ensure non-stop controlled intersections match road grade (max 5%) to eliminate any bump (i.e., change in grade) at the non-stop controlled intersection. It appears all ADA-accessible routes across intersections were designed with 1.5% cross-slope, which is not desireable for non-stop controlled intersections. Correction required.
|
|
Miscellaneous Correction
Corrective Action Required
Many of the notes for the ADA-accessible routes across streets and intersections state "5.00 ft. max". This should be called out as 5.00 feet, not "max". Correction required.
|
|
Miscellaneous Correction
Corrective Action Required
SWPPP is required prior to formal approval. Correction required.
|
|
|
Traffic Review - Streets
|
Corrections
|
10/23/2024
|
10/11/2024
|
|
Erin Ralovo
|
|
Misc
Corrective Action Required
Improvements along 150 HWY should be included with this submittal. MoDOT will have to give final approval but the staff will need to review as well.
|
|
Miscellaneous Correction
Corrective Action Required
Speed Limit sign at Sta. 4+28.73 should be 25 MPH not 15.
|
|
Miscellaneous Correction
Corrective Action Required
The merge lane for northbound traffic seems unnecessary. A single lane with a wider island may be a better fit.
|
|
Miscellaneous Correction
Corrective Action Required
Divided Road sign at Sta. 5+69.76 should be a Keep Right (R4-7).
|
|
Miscellaneous Correction
Corrective Action Required
Stop Sign at Sta. 6+72.45 should be removed.
|
|
Miscellaneous Correction
Corrective Action Required
Stop signs on side streets should also have street name signs (D-3)
|
|
Miscellaneous Correction
Corrective Action Required
Both Sta. 1+83.32 4" solid white are pointing to the wrong lines.
|
|
Miscellaneous Correction
Corrective Action Required
The striped out lane should have 24" chevrons not 18".
|
|
Miscellaneous Correction
Corrective Action Required
The through arrows going NB are not needed.
|
|
|