Summary
PRRES20242945
Building Permit - Residential
Temporary Occupancy
NEW DUPLEX
NEW DUPLEX - FINISHED AND UNFINISHED BASEMENT - ROOF TRUSSES - UNCOVERED DECK
06/07/2024
06/21/2024
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
BRUCER@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee for New Duplex $2,256.07 $2,256.07 Paid 06/21/2024
Sanitary Sewer Development Fee $4,318.00 $4,318.00 Paid 06/21/2024
Right of Way Permit Fee $85.00 $85.00 Paid 06/21/2024
Residential Excise Tax Fee $1,240.32 $1,240.32 Paid 06/21/2024
Water Tap Fee $7,520.00 $7,520.00 Paid 06/21/2024
Water Meter Fee $1,360.92 $1,360.92 Paid 06/21/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 11/26/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 11/26/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 11/26/2024
3rd and Subsequent Inspection Fee (Per Hour) $75.00 $75.00 Paid 11/26/2024
3rd and Subsequent Inspection Fee (Per Hour) $75.00 $75.00 Paid 11/26/2024
3rd and Subsequent Inspection Fee (Per Hour) $75.00 $75.00 Paid 11/26/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 11/26/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 02/05/2025
Temporary Occupancy Fee $50.00 $50.00 Paid 02/18/2025
Temporary Occupancy Fee $50.00 $50.00 Paid 03/21/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Pending
Miscellaneous Correction
Informational
11/19/2024
Erosion control measures are in place and must be properly maintained until CofO
Driveway Inspection Pending
Misc
Informational
02/03/2025
12-9-24 Dustin A, Both driveways are formed and compacted. Approved to pour 12-16-24 Dustin A, Forms still on 2-3-25 Dustin A, Forms are still on
Plot Plan Inspection Pending
Misc
Corrective Action Required
06/04/2025
Needs sod and splash blocks
Occupancy Inspection - Codes Residential Pending 4/20/2025
Miscellaneous Correction
Corrective Action Required
03/20/2025
3716 Passed for TCO only 3718 Passed for TCO only Both units sod and splash pads are not installed Land sewer tracer wire in boxes Side walks are not installed Driveway finals are not completed Plot has not had final grading Sump pump extensions must extend out 3 feet from the foundation
Sewer Service Inspection - R Failed 8/28/2024 08/28/2024
Miscellaneous Correction
Informational
08/28/2024
Unit 3718 passed. Other unit will be scheduled at a later date. This is a partial pass only
Sewer Service Inspection - R Passed 8/29/2024 08/29/2024
Miscellaneous Correction
Resolved
08/29/2024
Unit 3718 passed. Other unit will be scheduled at a later date. This is a partial pass only
Erosion Control Inspection Residential Partial 8/29/2024 08/29/2024
Miscellaneous Correction
Informational
08/29/2024
Erosion control measures are in place and must be maintained until CofO
Water Service Inspection - R Failed 8/29/2024 08/29/2024
Miscellaneous Correction
Informational
08/29/2024
-Both units have about 20 feet of PEX ran out from the foundation towards the street -Okay to cover PEX This is a partial pass only
Water Service Inspection - R Failed 8/30/2024 08/30/2024
Miscellaneous Correction
Resolved
08/30/2024
-Both units have about 20 feet of PEX ran out from the foundation towards the street -Okay to cover PEX This is a partial pass only
Miscellaneous Correction
Corrective Action Required
08/30/2024
Both waters passed and are okay to cover. Footing was never passed so water inspection failed
Water Service Inspection - R Passed 9/3/2024 09/03/2024
Miscellaneous Correction
Resolved
09/03/2024
Both waters passed and are okay to cover. Footing was never passed so water inspection failed
Footing Inspection - Residential Passed 9/3/2024 09/03/2024
Miscellaneous Correction
Informational
09/03/2024
Footing passed by a third party. Exterior piers were not mentioned in the footing report
Underslab Plumbing Inspection - Residential Passed 9/4/2024 9/4/2024 09/04/2024
Erosion Control Inspection Residential Partial 9/4/2024 09/04/2024
Miscellaneous Correction
Informational
08/29/2024
Erosion control measures are in place and must be maintained until CofO
Erosion Control Inspection Residential Partial 10/24/2024 10/24/2024
Miscellaneous Correction
Informational
09/04/2024
Erosion control measures are in place and must be maintained until CofO
All Rough Inspection - Residential Not Ready 10/24/2024 10/24/2024 10/24/2024
Miscellaneous Correction
Corrective Action Required
10/24/2024
3716 - 3718 SW Knoxville. All rough 3716 Garage anchor bolts are not installed in the middle 1/3 of sole plate Garage anchor bolts need to be installed 4-12 inches from the ends of the sole plate Garage anchor bolts need to be tightened down Some cantilevered fire blocking is missing over the overhead garage door Electrical is not started Fire blocking is not started House is not ready on either side This is not a complete list
All Rough Inspection - Residential Failed 10/29/2024 10/29/2024 10/29/2024
Miscellaneous Correction
Resolved
10/29/2024
3716 - 3718 SW Knoxville. All rough 3716 Garage anchor bolts are not installed in the middle 1/3 of sole plate Garage anchor bolts need to be installed 4-12 inches from the ends of the sole plate Garage anchor bolts need to be tightened down Some cantilevered fire blocking is missing over the overhead garage door Electrical is not started Fire blocking is not started House is not ready on either side This is not a complete list
Miscellaneous Correction
Informational
10/29/2024
Exterior of garage sheeting (PHF) passed and is okay to cover This is a partial pass only
Erosion Control Inspection Residential Failed 11/1/2024 11/01/2024
Miscellaneous Correction
Resolved
11/01/2024
Erosion control measures are in place and must be maintained until CofO
Miscellaneous Correction
Corrective Action Required
11/01/2024
Erosion control measures at the front of the lot are either damaged or missing and needs to be repaired or replaced Full erosion control measures must be in place and properly maintained until CofO
Gas Service Inspection - Residential Failed 10/24/2024 11/5/2024 11/05/2024
Miscellaneous Correction
Corrective Action Required
11/05/2024
Gas gauge at 3716 is below 5 PSI 3718 passed
Rated Assembly Inspection Not Ready 11/5/2024 11/05/2024
Miscellaneous Correction
Corrective Action Required
11/05/2024
Vertical fire blocking is not done This is not a complete list Walk your property before scheduling inspections. Not ready
All Rough Inspection - Residential Not Ready 11/5/2024 11/5/2024 11/05/2024
Miscellaneous Correction
Informational
10/29/2024
Exterior of garage sheeting (PHF) passed and is okay to cover This is a partial pass only
Miscellaneous Correction
Corrective Action Required
11/05/2024
Fire blocking in not completed throughout This is not a complete list Walk your property before scheduling inspections. Not ready
Erosion Control Inspection Residential Failed 11/8/2024 11/08/2024
Miscellaneous Correction
Corrective Action Required
11/01/2024
Erosion control measures at the front of the lot are either damaged or missing and needs to be repaired or replaced Full erosion control measures must be in place and properly maintained until CofO Second notice
Rated Assembly Inspection Failed 11/8/2024 11/8/2024 11/08/2024
Miscellaneous Correction
Resolved
11/08/2024
Vertical fire blocking is not done This is not a complete list Walk your property before scheduling inspections. Not ready
Miscellaneous Correction
Corrective Action Required
11/08/2024
Fire rated roof sheathing at ridge in unit 3716 has a gap larger than 1/4 of an inch
All Rough Inspection - Residential Failed 11/8/2024 11/8/2024 11/08/2024
Miscellaneous Correction
Resolved
11/08/2024
Exterior of garage sheeting (PHF) passed and is okay to cover This is a partial pass only
Miscellaneous Correction
Resolved
11/08/2024
Fire blocking in not completed throughout This is not a complete list Walk your property before scheduling inspections. Not ready
Miscellaneous Correction
Corrective Action Required
11/08/2024
? Kyle Beard ? 3812 SW Ravengate. All rough (5) Garage anchor bolts need to be in the middle 1/3 of sole plate Garage jack stud at overhead garage door header needs a electrical nail guard S/W corner Garage jack studs at N/W corner are over cut at electrical Garage walls are missing 2 2x6 and 3 2x4 king studs Garage LIB is not installed to length Electrical nail guard is needed in powder bathroom south wall Fire block top of chase upstairs above HVAC (new fire blocking must be 3/4 of an inch or more) Provide blocking for snow flashing at gable ends Joist hangers are not installed in the basement above the stairs for 2x10 floor ( straighten out bent over nails at installed joist hanger) Basement wall at the stairs, needs to be vertically fire blocked at 10 feet on center
Electrical Service Inspection Passed 10/24/2024 11/8/2024 11/08/2024
Gas Service Inspection - Residential Failed 11/8/2024 11/8/2024 11/08/2024
Miscellaneous Correction
Corrective Action Required
11/05/2024
Gas gauge at 3716 is below 5 PSI 3718 passed
All Rough Inspection - Residential Failed 11/8/2024 11/08/2024
Miscellaneous Correction
Resolved
11/08/2024
? Kyle Beard ? 3812 SW Ravengate. All rough (5) Garage anchor bolts need to be in the middle 1/3 of sole plate Garage jack stud at overhead garage door header needs a electrical nail guard S/W corner Garage jack studs at N/W corner are over cut at electrical Garage walls are missing 2 2x6 and 3 2x4 king studs Garage LIB is not installed to length Electrical nail guard is needed in powder bathroom south wall Fire block top of chase upstairs above HVAC (new fire blocking must be 3/4 of an inch or more) Provide blocking for snow flashing at gable ends Joist hangers are not installed in the basement above the stairs for 2x10 floor ( straighten out bent over nails at installed joist hanger) Basement wall at the stairs, needs to be vertically fire blocked at 10 feet on center
Miscellaneous Correction
Corrective Action Required
11/08/2024
3716 and 3718 SW Knoxville. All rough 3716 Garage anchor bolts needs to be located in the middle 1/3 of bottom plate Tightened down PFH anchor bolts Garage anchor bolts must be between 4-12 inches from bottom plate ends Provide missing fire blocking at overhead garage door for cantilevered floor trusses Fire blocking is broken out over garage Ibeam Holes are closer than 2 inches together at electrical in PFH north side leg Vertical fire blocking is missing for 1/2 of king stud in garage at demising wall Seal gaps in fire blocking above entry door Electrical nail guards are needed in the pantry Provide blocking for snow flashing at gable end Fire rated roof sheathing at the ridge can have more than 1/4 of an inch gap Gas gauge is at 0 PSI 3718 Garage anchor bolts need to be located in the middle 1/3 of bottom plate Tightened down PFH anchor bolts Install missing cantilever fire blocking above garage overhead door Repair LIB in garage by overhead door Seal top of garage chase at plumbing lines for fire blocking Hole in vertical fire blocking in great room at demising wall Provide blocking for snow flashing at gable end Provide more fire caulking around electrical service wire at demising wall for proper coverage and around electrical bonding wire
Rated Assembly Inspection Failed 11/15/2024 11/15/2024 11/15/2024
Miscellaneous Correction
Corrective Action Required
11/08/2024
Fire rated roof sheathing at ridge in unit 3716 has a gap larger than 1/4 of an inch (Provide information on caulking used) 3718 Better seal electrical service cable and bonding wire at demising wall
Gas Service Inspection - Residential Passed 11/15/2024 11/15/2024 11/15/2024
Miscellaneous Correction
Resolved
11/15/2024
Gas gauge at 3716 is below 5 PSI 3718 passed
All Rough Inspection - Residential Failed 11/15/2024 11/15/2024 11/15/2024
Miscellaneous Correction
Resolved
11/15/2024
3716 and 3718 SW Knoxville. All rough 3716 Garage anchor bolts needs to be located in the middle 1/3 of bottom plate Tightened down PFH anchor bolts Garage anchor bolts must be between 4-12 inches from bottom plate ends Provide missing fire blocking at overhead garage door for cantilevered floor trusses Fire blocking is broken out over garage Ibeam Holes are closer than 2 inches together at electrical in PFH north side leg Vertical fire blocking is missing for 1/2 of king stud in garage at demising wall Seal gaps in fire blocking above entry door Electrical nail guards are needed in the pantry Provide blocking for snow flashing at gable end Fire rated roof sheathing at the ridge can have more than 1/4 of an inch gap Gas gauge is at 0 PSI 3718 Garage anchor bolts need to be located in the middle 1/3 of bottom plate Tightened down PFH anchor bolts Install missing cantilever fire blocking above garage overhead door Repair LIB in garage by overhead door Seal top of garage chase at plumbing lines for fire blocking Hole in vertical fire blocking in great room at demising wall Provide blocking for snow flashing at gable end Provide more fire caulking around electrical service wire at demising wall for proper coverage and around electrical bonding wire
Miscellaneous Correction
Corrective Action Required
11/15/2024
3716 and 3718 SW Knoxville. 3716 Garage anchor bolts needs to be located in the middle 1/3 of bottom plate (missing one along the south wall) Provide missing fire blocking at overhead garage door for cantilevered floor trusses Fire blocking is broken out over garage Ibeam Holes are closer than 2 inches together at electrical in PFH north side leg Vertical fire blocking is missing for 1/2 of king stud in garage at demising wall Fire rated roof sheathing at the ridge can have more than 1/4 of an inch gap (provide caulking information that was used) 3718 Seal top of garage chase at plumbing lines for fire blocking (still missing some Fire blocking) Hole in vertical fire blocking in great room at demising wall (about 8 feet up from the floor) Provide more fire caulking around electrical service wire at demising wall for proper coverage and around electrical bonding wire
All Rough Inspection - Residential Failed 11/19/2024 11/19/2024 11/19/2024
Miscellaneous Correction
Resolved
11/19/2024
3716 and 3718 SW Knoxville. 3716 Garage anchor bolts needs to be located in the middle 1/3 of bottom plate (missing one along the south wall) Provide missing fire blocking at overhead garage door for cantilevered floor trusses Fire blocking is broken out over garage Ibeam Holes are closer than 2 inches together at electrical in PFH north side leg Vertical fire blocking is missing for 1/2 of king stud in garage at demising wall Fire rated roof sheathing at the ridge can have more than 1/4 of an inch gap (provide caulking information that was used) 3718 Seal top of garage chase at plumbing lines for fire blocking (still missing some Fire blocking) Hole in vertical fire blocking in great room at demising wall (about 8 feet up from the floor) Provide more fire caulking around electrical service wire at demising wall for proper coverage and around electrical bonding wire
Miscellaneous Correction
Corrective Action Required
11/19/2024
3716 Holes are closer than 2 inches together at electrical in PFH north side leg (3) holes are within a 2 inch span and effect the structure support Vertical fire blocking is missing for 1/2 of king stud in garage at demising wall Fire rated roof sheathing at the ridge can have more than 1/4 of an inch gap (provide caulking information that was used) (2x4’s used are not considered for fire rated assembly requirements) 3718 Hole in vertical fire blocking in great room at demising wall (about 8 feet up from the floor) Provide more fire caulking around electrical service wire at demising wall for proper coverage and around electrical bonding wire
Erosion Control Inspection Residential Partial 11/19/2024 11/19/2024
Miscellaneous Correction
Resolved
11/19/2024
Erosion control measures at the front of the lot are either damaged or missing and needs to be repaired or replaced Full erosion control measures must be in place and properly maintained until CofO Second notice
Miscellaneous Correction
Informational
11/19/2024
Erosion control measures are in place and must be properly maintained until CofO
Rated Assembly Inspection Failed 11/19/2024 11/19/2024 11/19/2024
Miscellaneous Correction
Corrective Action Required
11/15/2024
Fire rated roof sheathing at ridge in unit 3716 has a gap larger than 1/4 of an inch (Provide information on caulking used) 2x4’s used at ridge are not considered applicable for a rated assembly 3718 Better seal electrical service cable and bonding wire at demising wall
Rated Assembly Inspection Failed 11/22/2024 11/22/2024 11/22/2024
Miscellaneous Correction
Resolved
11/22/2024
Fire rated roof sheathing at ridge in unit 3716 has a gap larger than 1/4 of an inch (Provide information on caulking used) 2x4’s used at ridge are not considered applicable for a rated assembly 3718 Better seal electrical service cable and bonding wire at demising wall
Miscellaneous Correction
Corrective Action Required
11/22/2024
3718 Better seal electrical service cable and bonding wire at demising wall (Firewall/Rated assembly wall)
All Rough Inspection - Residential Failed 11/22/2024 11/22/2024 11/22/2024
Miscellaneous Correction
Corrective Action Required
11/19/2024
3716 Holes are closer than 2 inches together at electrical in PFH north side leg (3) holes are within a 2 inch span and effect the structure support Vertical fire blocking is missing for 1/2 of king stud in garage at demising wall Fire rated roof sheathing at the ridge can have more than 1/4 of an inch gap (provide caulking information that was used) (2x4’s used are not considered for fire rated assembly requirements) 3718 Hole in vertical fire blocking in great room at demising wall (about 8 feet up from the floor) Provide more fire caulking around electrical service wire at demising wall for proper coverage and around electrical bonding wire
Miscellaneous Correction
Corrective Action Required
11/22/2024
Provide more fire caulking around electrical service wire at demising (rated assembly)wall for proper coverage and around electrical bonding wire
Rated Assembly Inspection Not Ready 11/25/2024 11/25/2024 11/25/2024
Miscellaneous Correction
Corrective Action Required
11/22/2024
3718 Better seal electrical service cable and bonding wire at demising wall (Firewall/Rated assembly wall) -No improvements made from last inspection -Not ready 11/25/2024. KBEARD
All Rough Inspection - Residential Failed 11/25/2024 11/25/2024 11/25/2024
Miscellaneous Correction
Corrective Action Required
11/22/2024
3716 Holes are closer than 2 inches together at electrical in PFH north side leg (3) holes are within a 2 inch span and effect the structure support Vertical fire blocking is missing for 1/2 of king stud in garage at demising wall Fire rated roof sheathing at the ridge can have more than 1/4 of an inch gap (provide caulking information that was used) (2x4’s used are not considered for fire rated assembly requirements) 3718 Hole in vertical fire blocking in great room at demising wall (about 8 feet up from the floor) Provide more fire caulking around electrical service wire at demising wall for proper coverage and around electrical bonding wire
Miscellaneous Correction
Corrective Action Required
11/22/2024
Provide more fire caulking around electrical service wire at demising (rated assembly)wall for proper coverage and around electrical bonding wire
Rated Assembly Inspection Passed 11/26/2024 11/26/2024 11/26/2024
Miscellaneous Correction
Resolved
11/26/2024
3718 Better seal electrical service cable and bonding wire at demising wall (Firewall/Rated assembly wall) -No improvements made from last inspection -Not ready 11/25/2024. KBEARD
All Rough Inspection - Residential Passed 11/26/2024 11/26/2024 11/26/2024
Miscellaneous Correction
Resolved
11/26/2024
3716 Holes are closer than 2 inches together at electrical in PFH north side leg (3) holes are within a 2 inch span and effect the structure support Vertical fire blocking is missing for 1/2 of king stud in garage at demising wall Fire rated roof sheathing at the ridge can have more than 1/4 of an inch gap (provide caulking information that was used) (2x4’s used are not considered for fire rated assembly requirements) 3718 Hole in vertical fire blocking in great room at demising wall (about 8 feet up from the floor) Provide more fire caulking around electrical service wire at demising wall for proper coverage and around electrical bonding wire
Miscellaneous Correction
Resolved
11/26/2024
Provide more fire caulking around electrical service wire at demising (rated assembly)wall for proper coverage and around electrical bonding wire No improvements were made
Rated Assembly Inspection Failed 12/6/2024 12/6/2024 12/06/2024
Misc
Corrective Action Required
12/06/2024
16 - Repair sheet rock garage demise wall - More Screws needed at basement bedroom - No rock behind shower enclosure at basement - No sheet rock behind second floor shower 18 - No rock behind shower enclosure at basement - No sheet rock behind second floor shower - Screw off sill plate garage Denise wall
Driveway Inspection Partial 12/9/2024 12/9/2024 12/09/2024
Misc
Informational
12/09/2024
12-9-24 Dustin A, Both driveways are formed and compacted. Approved to pour
Rated Assembly Inspection Partial 12/11/2024 12/11/2024 12/11/2024
Misc
Resolved
12/11/2024
16 - Repair sheet rock garage demise wall - More Screws needed at basement bedroom 18 - - Screw off sill plate garage Denise wall
Rated Assembly Inspection Passed 12/11/2024 12/11/2024
Driveway Inspection Partial 12/16/2024 12/16/2024 12/16/2024
Misc
Informational
12/09/2024
12-9-24 Dustin A, Both driveways are formed and compacted. Approved to pour 12-16-24 Dustin A, Forms still on
Driveway Inspection Partial 2/3/2025 2/3/2025 02/03/2025
Misc
Informational
12/16/2024
12-9-24 Dustin A, Both driveways are formed and compacted. Approved to pour 12-16-24 Dustin A, Forms still on 2-3-25 Dustin A, Forms are still on
Sidewalk Inspection Failed 2/3/2025 2/3/2025 02/03/2025
Misc
Corrective Action Required
02/03/2025
2-3-25 Dustin A, sw has still not been poured
Occupancy Inspection - Codes Residential Failed 2/3/2025 2/3/2025 02/03/2025
Miscellaneous Correction
Corrective Action Required
02/03/2025
3716 • Seal penetrations in garage ceiling at overhead door track brackets • Back patio steps are on the wrong side of door exiting the house • Microwave plug is not installed • Anti hammer arrestor under sink is not installed • Secondly lock at patio door is not installed • Utility room washer anti hammer devices are not installed • Seal hatch under stairs in basement • Sump pump extension is not long enough (3ft minimum) 3718 • Patio door missing secondary lock • Electrical face plate for refrigerator is not installed Anti hammer • Seal hatch under stairs in basement • Electrical panel is not installed Both units • sod and splash pads are not installed • Land sewer tracer wire in boxes • Side walks are not installed • Driveway finals are not completed • Plot has not had final grading
Occupancy Inspection - Codes Residential Ready for Temp CO 2/5/2025 2/5/2025 02/05/2025
Miscellaneous Correction
Resolved
02/05/2025
3716 • Seal penetrations in garage ceiling at overhead door track brackets • Back patio steps are on the wrong side of door exiting the house • Microwave plug is not installed • Anti hammer arrestor under sink is not installed • Secondly lock at patio door is not installed • Utility room washer anti hammer devices are not installed • Seal hatch under stairs in basement • Sump pump extension is not long enough (3ft minimum) 3718 • Patio door missing secondary lock • Electrical face plate for refrigerator is not installed Anti hammer • Seal hatch under stairs in basement • Electrical panel is not installed Both units • sod and splash pads are not installed • Land sewer tracer wire in boxes • Side walks are not installed • Driveway finals are not completed • Plot has not had final grading
Miscellaneous Correction
Corrective Action Required
02/14/2025
3716 • Seal penetrations in garage ceiling at overhead door track brackets 3718 • passed for TCO only Both units • sod and splash pads are not installed • Land sewer tracer wire in boxes • Side walks are not installed • Driveway finals are not completed • Plot has not had final grading Sump pump extensions need to extened at least 3 feet out from the foundation
Miscellaneous Correction
Resolved
02/14/2025
3716 • Seal penetrations in garage ceiling at overhead door track brackets • Back patio steps are on the wrong side of door exiting the house • Microwave plug is not installed • Anti hammer arrestor under sink is not installed • Secondly lock at patio door is not installed • Utility room washer anti hammer devices are not installed • Seal hatch under stairs in basement • Sump pump extension is not long enough (3ft minimum) 3718 • passed for TCO only Both units • sod and splash pads are not installed • Land sewer tracer wire in boxes • Side walks are not installed • Driveway finals are not completed • Plot has not had final grading
Occupancy Inspection - Codes Residential Failed 2/14/2025 2/14/2025 02/14/2025
Miscellaneous Correction
Corrective Action Required
02/05/2025
3716 • Seal penetrations in garage ceiling at overhead door track brackets • Back patio steps are on the wrong side of door exiting the house • Microwave plug is not installed • Anti hammer arrestor under sink is not installed • Secondly lock at patio door is not installed • Utility room washer anti hammer devices are not installed • Seal hatch under stairs in basement • Sump pump extension is not long enough (3ft minimum) 3718 • passed for TCO only Both units • sod and splash pads are not installed • Land sewer tracer wire in boxes • Side walks are not installed • Driveway finals are not completed • Plot has not had final grading
Occupancy Inspection - Codes Residential Failed 2/14/2025 02/14/2025
Miscellaneous Correction
Corrective Action Required
02/14/2025
3716 Seal penetrations in garage ceiling at overhead door track brackets 3718 Passed for TCO only Both units sod and splash pads are not installed Land sewer tracer wire in boxes Side walks are not installed Driveway finals are not completed Plot has not had final grading Sump pump extensions must extend out 3 feet from the foundation
Occupancy Inspection - Codes Residential Ready for Temp CO 2/18/2025 2/18/2025 02/18/2025
Miscellaneous Correction
Resolved
02/18/2025
3716 Seal penetrations in garage ceiling at overhead door track brackets 3718 Passed for TCO only Both units sod and splash pads are not installed Land sewer tracer wire in boxes Side walks are not installed Driveway finals are not completed Plot has not had final grading Sump pump extensions must extend out 3 feet from the foundation
Miscellaneous Correction
Corrective Action Required
02/18/2025
3716 Passed for TCO only 3718 Passed for TCO only Both units sod and splash pads are not installed Land sewer tracer wire in boxes Side walks are not installed Driveway finals are not completed Plot has not had final grading Sump pump extensions must extend out 3 feet from the foundation
Sidewalk Inspection Partial 3/10/2025 3/10/2025 03/10/2025
Misc
Corrective Action Required
02/03/2025
2-3-25 Dustin A, sw has still not been poured 03-10-25 Jamie S, SW is compacted, and slopes are in compliance. Approved to pour.
Sidewalk Inspection Passed 3/17/2025 3/17/2025 03/17/2025
Misc
Corrective Action Required
03/10/2025
2-3-25 Dustin A, sw has still not been poured 03-10-25 Jamie S, SW is compacted, and slopes are in compliance. Approved to pour. 3-17-25 Dustin A, Sw has been poured to city specs. Slopes are in compliance. Pass
Occupancy Inspection - Codes Residential Ready for Temp CO 3/20/2025 03/20/2025
Miscellaneous Correction
Corrective Action Required
02/18/2025
3716 Passed for TCO only 3718 Passed for TCO only Both units sod and splash pads are not installed Land sewer tracer wire in boxes Side walks are not installed Driveway finals are not completed Plot has not had final grading Sump pump extensions must extend out 3 feet from the foundation
Plot Plan Inspection Failed 6/4/2025 06/04/2025
Misc
Corrective Action Required
06/04/2025
Needs sod and splash blocks
Documents & Images
Date Uploaded File Type Document Name
06/07/2024 OS #79 - ENGINEERED PLANS
06/07/2024 OS #79 - PERMIT APP
06/07/2024 OS #79 - PLOT PLAN
06/07/2024 OS #79 - TRUSS DETAILS
06/07/2024 OS #79 - TRUSS LAYOUT
06/11/2024 Approved Plans APPROVED PLANS
06/11/2024 Plot Plan APPROVED PLOT PLAN
06/11/2024 Approved Plans APPROVED TRUSS LAYOUT
06/11/2024 Approved Plans APPROVED TRUSS PACKAGE
06/11/2024 Permit Codes Residential Plan Review
06/21/2024 Permit DS Building Permit
06/21/2024 Receipt Receipt for transaction:2024-005001
08/28/2024 Letter INSPECTION SUMMARY
08/29/2024 Letter INSPECTION SUMMARY
08/29/2024 Letter INSPECTION SUMMARY
08/29/2024 Letter INSPECTION SUMMARY
08/30/2024 Letter INSPECTION SUMMARY
08/30/2024 3716 & 3718 Knoxville Ct LSMO Footing Inspection Report 8-20-24
09/03/2024 Letter INSPECTION SUMMARY
09/03/2024 Letter INSPECTION SUMMARY
09/04/2024 Letter INSPECTION SUMMARY
09/04/2024 Letter INSPECTION SUMMARY
10/24/2024 Letter INSPECTION SUMMARY
10/24/2024 Letter INSPECTION SUMMARY
10/29/2024 Letter INSPECTION SUMMARY
10/29/2024 Email Osage Duplexes Rear Wall Email
11/01/2024 Letter INSPECTION SUMMARY
11/05/2024 Letter INSPECTION SUMMARY
11/05/2024 Letter INSPECTION SUMMARY
11/05/2024 Letter INSPECTION SUMMARY
11/08/2024 Letter INSPECTION SUMMARY
11/08/2024 Letter INSPECTION SUMMARY
11/08/2024 Letter INSPECTION SUMMARY
11/08/2024 Letter INSPECTION SUMMARY
11/08/2024 Letter INSPECTION SUMMARY
11/15/2024 Letter INSPECTION SUMMARY
11/15/2024 Letter INSPECTION SUMMARY
11/15/2024 Letter INSPECTION SUMMARY
11/19/2024 Letter INSPECTION SUMMARY
11/19/2024 Letter INSPECTION SUMMARY
11/19/2024 Letter INSPECTION SUMMARY
11/19/2024 Letter INSPECTION SUMMARY
11/19/2024 Letter INSPECTION SUMMARY
11/22/2024 Letter INSPECTION SUMMARY
11/22/2024 Letter INSPECTION SUMMARY
11/25/2024 Letter INSPECTION SUMMARY
11/25/2024 Letter INSPECTION SUMMARY
11/26/2024 Receipt Receipt for transaction:2024-009169
11/26/2024 Letter INSPECTION SUMMARY
12/06/2024 Letter INSPECTION SUMMARY
12/06/2024 Letter INSPECTION SUMMARY
12/09/2024 Letter INSPECTION SUMMARY
12/11/2024 Letter INSPECTION SUMMARY
12/16/2024 Letter INSPECTION SUMMARY
02/03/2025 Letter INSPECTION SUMMARY
02/03/2025 Letter INSPECTION SUMMARY
02/03/2025 Letter INSPECTION SUMMARY
02/05/2025 Certificate/License Codes Temporary Certificate of Occupancy
02/05/2025 Receipt Receipt for transaction:2025-000753
02/14/2025 Letter INSPECTION SUMMARY
02/18/2025 Letter INSPECTION SUMMARY
02/18/2025 Certificate/License Codes Temporary Certificate of Occupancy
02/18/2025 Receipt Receipt for transaction:2025-000955
03/10/2025 Letter INSPECTION SUMMARY
03/17/2025 Letter INSPECTION SUMMARY
03/17/2025 Letter INSPECTION SUMMARY
03/20/2025 Letter INSPECTION SUMMARY
03/21/2025 Certificate/License Codes Temporary Certificate of Occupancy
03/21/2025 Receipt Receipt for transaction:2025-001709
04/11/2025 OS #79 - TCO Extension 4_11_25
06/03/2025 Plot Plan APPROVED AS GRADED PLOT PLAN
06/04/2025 Letter INSPECTION SUMMARY
06/04/2025 Letter INSPECTION SUMMARY
06/04/2025 Letter INSPECTION SUMMARY
06/04/2025 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home