Permit Application Status

PRRES20242294


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20242294
Building Permit - Residential
Temporary Occupancy
DOMAIN TIMBERLAKE MULTISTATE LLC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - ROOF TRUSSES -
05/07/2024
05/08/2024
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
DOMAIN TIMBERLAKE MULTISTATE LLC, Address:590 MADISON AVE FL 13TH  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
BRUCER@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 05/08/2024
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 05/08/2024
7232302-Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 05/08/2024
8331401-Water Tap Fee $3,760.00 $3,760.00 Paid 05/08/2024
8350015-Water Meter Fee $680.46 $680.46 Paid 05/08/2024
9110078-Valuation Fee New Single Family $1,359.99 $1,359.99 Paid 05/08/2024
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 12/12/2024
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 12/12/2024
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 12/12/2024
9110080-3rd and Subsequent Inspection Fee (Per Hour) $75.00 $75.00 Paid 12/12/2024
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 12/12/2024
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 12/12/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 12/18/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 01/17/2025
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 02/07/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Pending
Occupancy Inspection - Codes Residential Pending
Misc
Corrective Action Required
04/11/2025
sump pump discharge to extend 36” from foundation
Sewer Service Inspection - R Passed 6/4/2024 06/04/2024
Footing Inspection - Residential Passed 6/4/2024 06/04/2024
Underslab Plumbing Inspection - Residential Failed 6/18/2024 6/18/2024 06/18/2024
Misc
Corrective Action Required
06/18/2024
Provide address for inspection
Underslab Plumbing Inspection - Residential Passed 6/20/2024 6/20/2024 06/20/2024
Misc
Resolved
06/20/2024
Provide address for inspection
Erosion Control Inspection Residential Partial 6/20/2024 06/20/2024
Misc
Informational
06/20/2024
Erosion control in compliance at time of inspection.
Water Service Inspection - R Passed 7/2/2024 7/2/2024 07/02/2024
All Rough Inspection - Residential Failed 7/29/2024 7/29/2024 07/29/2024
Misc
Corrective Action Required
07/29/2024
NO FURTHER INSPECTIONS UNTIL EROSION CONTROL IS IN COMPLIANCE Garage portal frame okay to cover Front porch area not nailed to plans
Erosion Control Inspection Residential Failed 7/29/2024 07/29/2024
Misc
Resolved
07/29/2024
Erosion control in compliance at time of inspection.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
07/29/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Repair down silt fence and maintain erosion control at front of lot
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
07/29/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Erosion Control Inspection Residential Partial 7/31/2024 07/31/2024
DCM3 ESC REQUIRED 2 DAY
Resolved
07/31/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Repair down silt fence and maintain erosion control at front of lot
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
07/31/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Misc
Informational
07/31/2024
7/31/24 In compliance at time of inspection
All Rough Inspection - Residential Failed 7/31/2024 07/31/2024
Misc
Informational
07/31/2024
Garage portal frame and front porch area only okay to cover
All Rough Inspection - Residential Not Ready 9/19/2024 9/19/2024 09/19/2024
Misc
Informational
07/31/2024
Garage portal frame and front porch area only okay to cover
Misc
Corrective Action Required
09/19/2024
No city stamped plans on site. Not ready
All Rough Inspection - Residential Not Ready 9/20/2024 9/20/2024 09/20/2024
Misc
Informational
09/19/2024
Garage portal frame and front porch area only okay to cover
Misc
Resolved
09/20/2024
No city stamped plans on site. Not ready
Misc
Corrective Action Required
09/20/2024
HOME NOT READY FOR INSPECTION COMPLETE ALL ITEMPS BEFORE CALLING FOR RE INSPECTION MAIN FLOOR ONLY INSPECTED. -install Lib to plans -address top plate notched for dryer vent strap top plate to code -protect dryer vent at top plate -fire block furr out wall at top plate -address electrical panel not installed -strap top plate to code at dwv in bath 1 exterior wall where over notched. -seal dead space at bath 1 -seal top plate penetration at bed 1 entry -strap top plate bed 1 SE corner -fire block top of fireplace to ceiling space -fire block kitchen dead space to ceiling space -missing lateral bracing throughout -complete all framing and MEP IN basement Basement not inspected
All Rough Inspection - Residential Not Ready 10/1/2024 10/1/2024 10/01/2024
Misc
Informational
09/20/2024
Garage portal frame and front porch area only okay to cover
Misc
Corrective Action Required
09/20/2024
HOME NOT READY FOR INSPECTION COMPLETE ALL ITEMPS BEFORE CALLING FOR RE INSPECTION MAIN FLOOR ONLY INSPECTED. -install Lib to plans -address top plate notched for dryer vent strap top plate to code -protect dryer vent at top plate -fire block furr out wall at top plate -address electrical panel not installed -strap top plate to code at dwv in bath 1 exterior wall where over notched. -seal dead space at bath 1 -seal top plate penetration at bed 1 entry -strap top plate bed 1 SE corner -fire block top of fireplace to ceiling space -fire block kitchen dead space to ceiling space -missing lateral bracing throughout -complete all framing and MEP IN basement Basement not inspected
Misc
Corrective Action Required
10/01/2024
INSPECTION DENIED NOT READY NO PLANS ON SIGHT
All Rough Inspection - Residential Failed 10/4/2024 10/4/2024 10/04/2024
Misc
Informational
10/01/2024
Garage portal frame and front porch area only okay to cover
Misc
Resolved
10/04/2024
Misc
Resolved
10/04/2024
Misc
Corrective Action Required
10/04/2024
- address over bored studs on bearing wall at electrical panel -fire block kitchen dead space to ceiling space ( height change, fire block at lower top plate) - fire block floor penetration at fireplace gas line - Secure CSST at fireplace - No UFER bond to electrical panel - Sold block cantilever basement back wall - Seal gaps at top plate west wall basement - Seal gaps south wall around soffit basement - Fire block top plate above windows in basement - Seal gaps at top plate basement bedroom 4 - Provide exhaust fan and complete ductwork basement bathroom - Vent bar sink to outside in basement
Gas Service Inspection - Residential Passed 10/4/2024 10/4/2024 10/04/2024
Electrical Service Inspection Failed 10/4/2024 10/4/2024 10/04/2024
Misc
Corrective Action Required
10/04/2024
No UFER ground to fist means of disconnect
All Rough Inspection - Residential Failed 10/11/2024 10/11/2024 10/11/2024
Misc
Resolved
10/11/2024
Garage portal frame and front porch area only okay to cover
Misc
Corrective Action Required
10/04/2024
NO FURTHER INSPECTIONS UNTIL EROSION CONTROL IS IN COMPLIANCE - address over bored studs on bearing wall at electrical panel -fire block kitchen dead space to ceiling space ( height change, fire block at lower top plate) - fire block floor penetration at fireplace gas line - Secure CSST at fireplace - No UFER bond to electrical panel - Sold block cantilever basement back wall - Seal gaps at top plate west wall basement - Seal gaps south wall around soffit basement - Fire block top plate above windows in basement - Seal gaps at top plate basement bedroom 4 - Provide exhaust fan and complete ductwork basement bathroom - Vent bar sink to outside in basement
All Rough Inspection - Residential Failed 10/11/2024 10/11/2024 10/11/2024
Misc
Corrective Action Required
10/11/2024
NO FURTHER INSPECTIONS UNTIL EROSION CONTROL IS IN COMPLIANCE - address over bored studs on bearing wall at electrical panel -fire block kitchen dead space to ceiling space ( height change, fire block at lower top plate) - fire block floor penetration at fireplace gas line - Secure CSST at fireplace - No UFER bond to electrical panel - Seal gaps south wall around soffit basement - Fire block top plate above windows in basement (seal gaps)
Erosion Control Inspection Residential Failed 10/11/2024 10/11/2024
Misc
Resolved
10/11/2024
7/31/24 In compliance at time of inspection
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
10/11/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
10/11/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
10/11/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. CLEAN TRASH FROM LOT AND REPAIR EROSION CONTROL
All Rough Inspection - Residential Not Ready 10/15/2024 10/15/2024 10/15/2024
Misc
Corrective Action Required
10/11/2024
EROSION CONTROL STILL NOT IN COMPLIANCE NO FURTHER INSPECTIONS UNTIL EROSION CONTROL IS IN COMPLIANCE - address over bored studs on bearing wall at electrical panel -fire block kitchen dead space to ceiling space ( height change, fire block at lower top plate) - fire block floor penetration at fireplace gas line - Secure CSST at fireplace - No UFER bond to electrical panel - Seal gaps south wall around soffit basement - Fire block top plate above windows in basement (seal gaps)
All Rough Inspection - Residential Not Ready 10/16/2024 10/16/2024 10/16/2024
Misc
Corrective Action Required
10/15/2024
- address over bored stud on bearing wall at electrical panel -fire block kitchen dead space to ceiling space ( height change, fire block at lower top plate) - Secure CSST at fireplace - Seal gaps south wall around soffit basement (see SW corner) - Fire block top plate above windows in basement (seal gaps)
Electrical Service Inspection Passed 10/16/2024 10/16/2024 10/16/2024
Misc
Resolved
10/16/2024
No UFER ground to first means of disconnect
All Rough Inspection - Residential Failed 10/17/2024 10/17/2024 10/17/2024
Misc
Corrective Action Required
10/16/2024
-fire block kitchen dead space to ceiling space ( height change, fire block at lower top plate) - Secure CSST at fireplace - Fire block top plate above windows in basement (seal gaps)
All Rough Inspection - Residential Passed 10/18/2024 10/18/2024 10/18/2024
Misc
Resolved
10/18/2024
-fire block kitchen dead space to ceiling space ( height change, fire block at lower top plate) - Secure CSST at fireplace - Fire block top plate above windows in basement (seal gaps)
Driveway Inspection Partial 11/21/2024 11/21/2024 11/21/2024
Misc
Corrective Action Required
11/21/2024
11-21-24 Dustin A, DW is formed and compacted. Must cover overnight. Approved to pour
Erosion Control Inspection Residential Failed 11/26/2024 11/26/2024
DCM2 ESC DEFICIENT INSTALLATION
Resolved
11/26/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
DCM3 ESC REQUIRED 2 DAY
Resolved
11/26/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
11/26/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. CLEAN TRASH FROM LOT AND REPAIR EROSION CONTROL
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
11/26/2024
11/26/24 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -Install proper ESC methods at perimeter
Erosion Control Inspection Residential Partial 12/2/2024 12/2/2024 12/02/2024
DCM3 ESC REQUIRED 2 DAY
Resolved
12/02/2024
11/26/24 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -Install proper ESC methods at perimeter
Driveway Inspection Partial 12/2/2024 12/2/2024 12/02/2024
Misc
Corrective Action Required
11/21/2024
11-21-24 Dustin A, DW is formed and compacted. Must cover overnight. Approved to pour 12-2-24 Dustin A, DW poured to city specs. Cannot pass until forms pulled
Occupancy Inspection - Codes Residential Failed 12/13/2024 12/13/2024 12/13/2024
Misc
Corrective Action Required
12/13/2024
No address posted inspection denied
Occupancy Inspection - Codes Residential Failed 12/16/2024 12/16/2024 12/16/2024
Misc
Corrective Action Required
12/13/2024
-obtain issued lawn irrigation permit -address pending driveway inspection -final grade and sod -splash blocks and sump pump discharge to extend 36” from foundation -will check water meter at Time of final grade and sod. Ensure water meter pit lid flush with grade. Ensure 14”-18” from top of meter to well lid ring -identify sewer tracer wire -seal all exterior penetrations -all receptacles in unfinished spaces to be GFCI protected or single pull receptacle and labeled “non GFCI”
Driveway Inspection Passed 12/16/2024 12/16/2024 12/16/2024
Misc
Corrective Action Required
12/02/2024
11-21-24 Dustin A, DW is formed and compacted. Must cover overnight. Approved to pour 12-2-24 Dustin A, DW poured to city specs. Cannot pass until forms pulled 12-16-24 Dustin A, forms pulled, Passed
Plot Plan Inspection Passed 12/17/2024 12/17/2024
Occupancy Inspection - Codes Residential Failed 12/17/2024 12/17/2024 12/17/2024
Misc
Corrective Action Required
12/16/2024
-final grade and sod -splash blocks and sump pump discharge to extend 36” from foundation -will check water meter at Time of final grade and sod. Ensure water meter pit lid flush with grade. Ensure 14”-18” from top of meter to well lid ring -identify sewer tracer wire -seal all exterior penetrations -all receptacles in unfinished spaces to be GFCI protected or single pull receptacle and labeled “non GFCI”
Occupancy Inspection - Codes Residential Ready for Temp CO 12/18/2024 12/18/2024 12/18/2024
Misc
Corrective Action Required
12/17/2024
-final grade and sod -obtain issued lawn irrigation permit -splash blocks and sump pump discharge to extend 36” from foundation -will check water meter at Time of final grade and sod. Ensure water meter pit lid flush with grade. Ensure 14”-18” from top of meter to well lid ring -identify sewer tracer wire -seal all exterior penetrations
Occupancy Inspection - Codes Residential Ready for Temp CO 1/17/2025 01/17/2025
Misc
Corrective Action Required
12/18/2024
-final grade and sod -obtain issued lawn irrigation permit -splash blocks and sump pump discharge to extend 36” from foundation -will check water meter at Time of final grade and sod. Ensure water meter pit lid flush with grade. Ensure 14”-18” from top of meter to well lid ring -identify sewer tracer wire -seal all exterior penetrations
Occupancy Inspection - Codes Residential Ready for Temp CO 2/7/2025 02/07/2025
Misc
Corrective Action Required
01/17/2025
-final grade and sod -obtain issued lawn irrigation permit -splash blocks and sump pump discharge to extend 36” from foundation -will check water meter at Time of final grade and sod. Ensure water meter pit lid flush with grade. Ensure 14”-18” from top of meter to well lid ring -identify sewer tracer wire -seal all exterior penetrations
Occupancy Inspection - Codes Residential Failed 3/14/2025 3/14/2025 03/14/2025
Misc
Corrective Action Required
02/07/2025
sump pump discharge to extend 36” from foundation -identify sewer tracer wire
Occupancy Inspection - Codes Residential Failed 4/11/2025 4/11/2025 04/11/2025
Misc
Corrective Action Required
03/14/2025
sump pump discharge to extend 36” from foundation
Documents & Images
Date Uploaded File Type Document Name
05/07/2024 HT #184 - ENGINEERED PLANS
05/07/2024 HT #184 - PERMIT APP
05/07/2024 HT #184 - PLOT PLAN
05/07/2024 HT #184 - TRUSS DETAILS
05/07/2024 HT #184 - TRUSS LAYOUT
05/07/2024 Approved Plans APPROVED PLANS
05/07/2024 Plot Plan APPROVED PLOT PLAN
05/07/2024 Approved Plans APPROVED TRUSS LAYOUT
05/07/2024 Approved Plans APPROVED TRUSS PACKAGE
05/08/2024 Permit Codes Residential Plan Review
05/08/2024 Permit DS Building Permit
05/08/2024 Receipt Receipt for transaction:2024-003129
05/23/2024 M L Crose 1609 SW Arborway Terr LSMO Footing Inspection Report 5-23-24
06/04/2024 Letter INSPECTION SUMMARY
06/04/2024 Letter INSPECTION SUMMARY
06/18/2024 Letter INSPECTION SUMMARY
06/20/2024 Letter INSPECTION SUMMARY
06/20/2024 Letter INSPECTION SUMMARY
07/02/2024 Letter INSPECTION SUMMARY
07/29/2024 Letter INSPECTION SUMMARY
07/29/2024 Letter INSPECTION SUMMARY
07/31/2024 Letter INSPECTION SUMMARY
07/31/2024 Letter INSPECTION SUMMARY
09/19/2024 Letter INSPECTION SUMMARY
09/20/2024 Letter INSPECTION SUMMARY
10/04/2024 Letter INSPECTION SUMMARY
10/04/2024 Letter INSPECTION SUMMARY
10/04/2024 Letter INSPECTION SUMMARY
10/04/2024 Letter INSPECTION SUMMARY
10/11/2024 Letter INSPECTION SUMMARY
10/11/2024 Letter INSPECTION SUMMARY
10/11/2024 Letter INSPECTION SUMMARY
10/15/2024 Letter INSPECTION SUMMARY
10/16/2024 Letter INSPECTION SUMMARY
10/16/2024 Letter INSPECTION SUMMARY
10/17/2024 Letter INSPECTION SUMMARY
10/18/2024 Letter INSPECTION SUMMARY
11/21/2024 Letter INSPECTION SUMMARY
11/26/2024 Letter INSPECTION SUMMARY
12/02/2024 Letter INSPECTION SUMMARY
12/02/2024 Letter INSPECTION SUMMARY
12/12/2024 Receipt Receipt for transaction:2024-009484
12/13/2024 Letter INSPECTION SUMMARY
12/16/2024 Letter INSPECTION SUMMARY
12/16/2024 Letter INSPECTION SUMMARY
12/17/2024 Letter INSPECTION SUMMARY
12/17/2024 Letter INSPECTION SUMMARY
12/18/2024 Letter INSPECTION SUMMARY
12/18/2024 Certificate/License Codes Temporary Certificate of Occupancy
12/18/2024 Receipt Receipt for transaction:2024-009582
01/07/2025 Application Form EXTENSION FORM
01/17/2025 Certificate/License Codes Temporary Certificate of Occupancy
01/17/2025 Receipt Receipt for transaction:2025-000318
01/17/2025 Letter INSPECTION SUMMARY
02/06/2025 HT #184 - TCO Extension App 2_6_25
02/07/2025 Certificate/License Codes Temporary Certificate of Occupancy
02/07/2025 Receipt Receipt for transaction:2025-000812
02/27/2025 HT #184 - TCO Extension App 2_27_25
03/14/2025 Letter INSPECTION SUMMARY
03/14/2025 Letter INSPECTION SUMMARY
04/11/2025 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home