Summary
PRRES20241596
Building Permit - Residential
Certificate of Occupancy
RISING STAR RANCH LLC
NEW SINGLE FAMILY
NEW HOUSE - BEING BUILT ON EXISTING FOUNDATION - PREVIOUS HOUSE BURNT DOWN - ROOF TRUSSES ( DEF ) - OWNER BUILDER DOING ALL OF THE WORK STOP WORK ORDER generated on 09/10/2024 12:00 AM by username 'Robb Popp'. STOP WORK ORDER removed on 12/13/2024 12:00 AM by username 'Mark Harding'.
04/02/2024
04/09/2024
10/01/2024
05/05/2025
Locations
Contacts
RISING STAR RANCH LLC, Address:2807 NW CHIPMAN RD, Phone:(816) 405-9675  
RISINGSTARRANCH@AOL.COM  
RISING STAR RANCH LLC, Address:2807 NW CHIPMAN RD  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
7232302-Residential License Tax Fee $1,022.72 $1,022.72 Paid 04/05/2024
$1,022.72
9110078-Valuation Fee New Single Family $1,160.88 $1,160.88 Paid 04/09/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 01/02/2025
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 02/04/2025
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 03/11/2025
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 05/05/2025
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 04/14/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Miscellaneous Inspection Failed - Stop Work 9/10/2024 9/10/2024 09/10/2024
Misc
Corrective Action Required
09/10/2024
House has been framed, all MEPs installed and sheet rocked. Walls are finished and fixtures are being installed. Electrical has not been ispected. No inspections have been performed. -Remove all sheet rock to expose all framing and MEPs, Expose underslab plumbing, submit engineered truss plans. Stop Work until resolved
Miscellaneous Inspection Failed 12/12/2024 12/13/2024 12/13/2024
Misc
Corrective Action Required
09/10/2024
House has been framed, all MEPs installed and sheet rocked. Walls are finished and fixtures are being installed. Electrical has not been ispected. No inspections have been performed. -Remove all sheet rock to expose all framing and MEPs, Expose underslab plumbing, submit engineered truss plans. Stop Work until resolved
Misc
Corrective Action Required
12/13/2024
Bill came in and met with Steve Robbins and I the week of 12/2. Items were discussed for completing the inspections. Pictures were emailed to me from Bill, although the pictures were not helpfull in determining any approval. Bill schudeled an inspection for 12/12 althought was unclear that he needed to pride the dye for a dye test for the underslab plumbing that was covered without inspection. Also we only had 2 inspectors on the 12th. we moved it to 12/13- He stated he wanted Occupnacy for the hirered hand house and i explained that that was not discussed and untill all aspects of the interior are approved and all inspections have been completed we would not grant him Occupancy.
Occupancy Inspection - Codes Residential Failed 12/13/2024 12/13/2024
Misc
Corrective Action Required
12/13/2024
DO NOT OCCUPY -Complete exterior (Missing siding, gutters, downspouts, window flashing, etc.) -Install code compliant steps at front entry and sliding glass door -Provide tamper resistant schrader valves -Ground electrical service panel per code -All electrical service equipment must comply with 2017 NEC (to be determined) -Provide AFCI protection per code -Provide interconnected smoke and CO alarms -Provide combo smoke/co alarm outside of bedrooms -Provide thermal expansion tank at water heater -Provide hammer arrestors at all quick close valves -Provide second receptacle within 36" of bathroom double vanity -Provide bath fans at restrooms -Provide receptacle within 24" of kitchen sink -Receptacles at kitchen to be GFCI -AC breaker to be max 25 amp -Extension cord in panel not approved wiring method -Provide 100 watt security lighting at rear per LS security code -Provide security screws at entry door per LS security code *DYE TEST APPROVED
Occupancy Inspection - Codes Residential Failed 12/20/2024 12/20/2024 12/20/2024
Misc
Corrective Action Required
12/13/2024
DO NOT OCCUPY -Post address -Complete exterior (Missing siding, gutters, downspouts, window flashing, etc.) -Install code compliant steps at front entry and sliding glass door **The landing at the code-required front exit door must be min 3 ft in depth, as measured in the direction of travel. The rear step is OK. The concrete blockings and wood planks used for the steps and landing are temporary for the purpose of TCO. Permanent steps and landing shall be provided for final CO approval -Provide tamper resistant schrader valves -Ground electrical service panel per code **Bond the service panel enclosure. The bonding screw is missing; install the #6 cu grounding electrode conductor inside the raceway -Label all breakers with correct equipment/location/etc -Install breaker lock for the out-of-sight water heater -Provide AFCI protection per code **Provide AFCI protection for all outlets required per NEC 210.12. All outlets (definition: receptacle, light, utilization equipments, etc) shall be afci-protected unless located in following areas: outdoor, fire alarm outlet, underfloor space, unfinished basement, garage, bathroom, and attic. -Provide hammer arrestors at all quick close valves **Dishwasher and laundry -Provide receptacle within 24" of kitchen sink **The countertop on the right side of the kitchen sink does not have a receptacle. Install a receptacle for this countertop, using the same 20 amp circuit for the other kitchen countertop receptacles -Receptacles at kitchen to be GFCI **Receptacle behind the range is not gfci-protected. You can blank off this receptacle since it's not required by code; the dishwasher receptacle outlet must be gfci-protected and must be at readily accessible location. Since it's located behind the dishwasher, it is not readily accessible. Install a breaker for the dishwasher outlet that provides both gfci and afci protection to meet the readily accessible requirement -Install anti-tipping device for the kitchen range -Provide security screws at entry door per LS security code **Security jamb brace. Contact door supply company **Comment: The PV system has not been changed from the approved pre-existing condition **All interior items and the front landing&step must be corrected in order for TCO to be issued. TCO issuance is subjected to approval by Robb/Mark
Occupancy Inspection - Codes Residential Failed 12/30/2024 12/30/2024 12/30/2024
Misc
Corrective Action Required
12/20/2024
DO NOT OCCUPY -Complete exterior (Missing siding, gutters, downspouts, window flashing, etc.) -Install permanent code compliant steps at front entry and sliding glass door **The concrete blockings and wood planks used for the steps and landing are temporary for the purpose of TCO. Permanent steps and landing shall be provided for final CO approval -Provide tamper resistant schrader valve covers **Comment: The PV system has not been changed from the approved pre-existing condition **All interior items and the front landing&step must be corrected in order for TCO to be issued. TCO issuance is subjected to approval by Robb/Mark
Occupancy Inspection - Codes Residential Ready for Temp CO 1/2/2025 1/2/2025 01/02/2025
Misc
Corrective Action Required
12/30/2024
DO NOT OCCUPY -Complete exterior (Missing siding, gutters, downspouts, window flashing, etc.) -Install permanent code compliant steps at front entry and sliding glass door **The concrete blockings and wood planks used for the steps and landing are temporary for the purpose of TCO. Permanent steps and landing shall be provided for final CO approval -Provide tamper resistant schrader valve covers **Comment: The PV system has not been changed from the approved pre-existing condition **All interior items and the front landing&step must be corrected in order for TCO to be issued. TCO issuance is subjected to approval by Robb/Mark
Misc
Corrective Action Required
01/02/2025
TCO issued for 30 days. Extension form needs to be applied prior to the end of the 30 days and an additional $50 for each extension will be required.
Occupancy Inspection - Codes Residential Ready for Temp CO 2/1/2025 02/04/2025
Misc
Corrective Action Required
01/02/2025
DO NOT OCCUPY -Complete exterior (Missing siding, gutters, downspouts, window flashing, etc.) -Install permanent code compliant steps at front entry and sliding glass door **The concrete blockings and wood planks used for the steps and landing are temporary for the purpose of TCO. Permanent steps and landing shall be provided for final CO approval -Provide tamper resistant schrader valve covers **Comment: The PV system has not been changed from the approved pre-existing condition **All interior items and the front landing&step must be corrected in order for TCO to be issued. TCO issuance is subjected to approval by Robb/Mark
Misc
Corrective Action Required
01/02/2025
TCO issued for 30 days. Extension form needs to be applied prior to the end of the 30 days and an additional $50 for each extension will be required.
Occupancy Inspection - Codes Residential Ready for Temp CO 3/11/2025 03/11/2025
Misc
Corrective Action Required
02/04/2025
DO NOT OCCUPY -Complete exterior (Missing siding, gutters, downspouts, window flashing, etc.) -Install permanent code compliant steps at front entry and sliding glass door **The concrete blockings and wood planks used for the steps and landing are temporary for the purpose of TCO. Permanent steps and landing shall be provided for final CO approval -Provide tamper resistant schrader valve covers **Comment: The PV system has not been changed from the approved pre-existing condition **All interior items and the front landing&step must be corrected in order for TCO to be issued. TCO issuance is subjected to approval by Robb/Mark
Misc
Corrective Action Required
02/04/2025
TCO issued for 30 days. Extension form needs to be applied prior to the end of the 30 days and an additional $50 for each extension will be required.
Occupancy Inspection - Codes Residential Failed 4/11/2025 04/11/2025
Misc
Corrective Action Required
03/11/2025
DO NOT OCCUPY -Complete exterior (Missing siding, gutters, downspouts, window flashing, etc.) -Install permanent code compliant steps at front entry and sliding glass door **The concrete blockings and wood planks used for the steps and landing are temporary for the purpose of TCO. Permanent steps and landing shall be provided for final CO approval -Provide tamper resistant schrader valve covers **Comment: The PV system has not been changed from the approved pre-existing condition **All interior items and the front landing&step must be corrected in order for TCO to be issued. TCO issuance is subjected to approval by Robb/Mark
Misc
Corrective Action Required
03/11/2025
TCO issued for 30 days. Extension form needs to be applied prior to the end of the 30 days and an additional $50 for each extension will be required.
Misc
Corrective Action Required
04/11/2025
4-11-25 10 day notice of violation sent. TCO expired
Occupancy Inspection - Codes Residential Ready for Temp CO 04/14/2025
Misc
Corrective Action Required
04/11/2025
DO NOT OCCUPY -Complete exterior (Missing siding, gutters, downspouts, window flashing, etc.) -Install permanent code compliant steps at front entry and sliding glass door **The concrete blockings and wood planks used for the steps and landing are temporary for the purpose of TCO. Permanent steps and landing shall be provided for final CO approval -Provide tamper resistant schrader valve covers **Comment: The PV system has not been changed from the approved pre-existing condition **All interior items and the front landing&step must be corrected in order for TCO to be issued. TCO issuance is subjected to approval by Robb/Mark
Misc
Corrective Action Required
04/11/2025
TCO issued for 30 days. Extension form needs to be applied prior to the end of the 30 days and an additional $50 for each extension will be required.
Misc
Corrective Action Required
04/11/2025
4-11-25 10 day notice of violation sent. TCO expired
Occupancy Inspection - Codes Residential Failed 5/2/2025 05/02/2025
Misc
Resolved
05/02/2025
DO NOT OCCUPY -Complete exterior (Missing siding, gutters, downspouts, window flashing, etc.) -Install permanent code compliant steps at front entry and sliding glass door **The concrete blockings and wood planks used for the steps and landing are temporary for the purpose of TCO. Permanent steps and landing shall be provided for final CO approval -Provide tamper resistant schrader valve covers **Comment: The PV system has not been changed from the approved pre-existing condition **All interior items and the front landing&step must be corrected in order for TCO to be issued. TCO issuance is subjected to approval by Robb/Mark
Misc
Resolved
05/02/2025
TCO issued for 30 days. Extension form needs to be applied prior to the end of the 30 days and an additional $50 for each extension will be required.
Misc
Corrective Action Required
04/14/2025
Pay outstanding TCO fee
Occupancy Inspection - Codes Residential Full C of O 05/05/2025
Misc
Resolved
05/05/2025
Pay outstanding TCO fee
Documents & Images
Date Uploaded File Type Document Name
04/02/2024 Application Form APPLICATION
04/02/2024 Engineer Report/Study foundation report
04/02/2024 Plans plans
04/04/2024 Permit Codes Residential Plan Review
04/05/2024 PERMIT RESUBMITTAL 4-5-24
04/09/2024 Approved Plans APPROVED PLANS
04/09/2024 Permit Codes Residential Plan Review
04/09/2024 Permit DS Building Permit
04/09/2024 Receipt Receipt for transaction:2024-002248
08/27/2024 Letter Codes 140 Day Letter
09/10/2024 Letter Stop Work Order
09/20/2024 IMG_0014
09/20/2024 IMG_0013
10/22/2024 3RD Party Insp Report ENGINEER REPORT
12/13/2024 Letter INSPECTION SUMMARY
12/13/2024 Letter INSPECTION SUMMARY
12/20/2024 Letter INSPECTION SUMMARY
12/30/2024 Letter INSPECTION SUMMARY
01/02/2025 Certificate/License Codes Temporary Certificate of Occupancy
01/02/2025 Receipt Receipt for transaction:2025-000022
02/03/2025 Application Form TCO EXTENSION
02/04/2025 Letter INSPECTION SUMMARY
02/04/2025 Letter INSPECTION SUMMARY
02/04/2025 Certificate/License Codes Temporary Certificate of Occupancy
02/04/2025 Receipt Receipt for transaction: 2025-000720
03/06/2025 Application Form TCO EXTENSION
03/11/2025 Letter INSPECTION SUMMARY
03/11/2025 Certificate/License Codes Temporary Certificate of Occupancy
03/11/2025 Receipt Receipt for transaction: 2025-001449
04/11/2025 Letter Codes 10 Day Letter
04/11/2025 Letter INSPECTION SUMMARY
04/11/2025 Application Form TCO EXTENSION
04/14/2025 Certificate/License Codes Temporary Certificate of Occupancy
04/14/2025 Receipt Receipt for transaction: 2025-002299
05/02/2025 Letter INSPECTION SUMMARY
05/02/2025 Letter INSPECTION SUMMARY
05/05/2025 Certificate/License Codes Temporary Certificate of Occupancy
05/05/2025 Receipt Receipt for transaction: 2025-002811
05/05/2025 Letter Codes Final Certificate of Occupancy
05/05/2025 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents