Summary
PRRES20241188
Building Permit - Residential
Temporary Occupancy
NEW DUPLEX
NEW DUPLEX - FINISHED AND UNFINISHED BASEMENT - SUSPENDED SLAB
03/14/2024
04/02/2024
09/17/2024
Locations
Contacts
ROCK CREEK HOMES, Address:6126 METCALF LANE, Phone:(913) 522-1945  
Kevin Guinan, Address:6126 Metcalf Lane  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
PRIDE SERVICES INC, Address:3842 GEORGIA TERR, Phone:(785) 242-9700  
BILL'S PLUMBING SERVICE LLC, Address:308 E PARK STREET, Phone:(913) 829-8213  
KEVIN@ROCKCREEKHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for New Duplex $2,610.45 $2,610.45 Paid 04/02/2024
8331507-Sanitary Sewer Development Fee $4,318.00 $4,318.00 Paid 04/02/2024
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 04/02/2024
8331401-Water Tap Fee $7,520.00 $7,520.00 Paid 04/02/2024
8350015-Water Meter Fee $1,360.92 $1,360.92 Paid 04/02/2024
7232302-Residential License Tax Fee $1,240.32 $1,240.32 Paid 04/02/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 04/29/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Pending
Miscellaneous Correction
Informational
11/01/2024
Full erosion control measures are in place at time of inspection.
Driveway Inspection Pending
Misc
Informational
02/04/2025
2-4-25 BR Driveway is formed up and aggregate is place and compacted ready for concrete.
Sidewalk Inspection Pending
Misc
Corrective Action Required
04/25/2025
4-25-25 RH. Sidewalk is missing at corner of Winthrop and Winthrop. Connection was not made due to utility box being in the way. Utility Box will need to be moved for sidewalk to be put in.
Occupancy Inspection - Codes Residential Pending
Misc
Corrective Action Required
04/29/2025
Both sides -address pending driveway and sidewalk inspection -final grade and sod
Plot Plan Inspection Pending 5/8/2025
Erosion Control Inspection Residential Partial 7/10/2024 07/10/2024
Misc
Corrective Action Required
07/10/2024
MAINTAIN EROSION CONTROL THROUGHOUT CONSTRUCTION
Footing Inspection - Residential Passed 7/10/2024 7/10/2024 07/10/2024
Sewer Service Inspection - R Passed 7/25/2024 07/25/2024
Erosion Control Inspection Residential Partial 7/25/2024 07/25/2024
Misc
Corrective Action Required
07/10/2024
MAINTAIN EROSION CONTROL THROUGHOUT CONSTRUCTION
Water Service Inspection - R Partial 7/25/2024 07/25/2024
Misc
Corrective Action Required
07/25/2024
-Partial inspection, pit and meter not installed
Erosion Control Inspection Residential Partial 7/30/2024 07/30/2024
Misc
Corrective Action Required
07/25/2024
MAINTAIN EROSION CONTROL THROUGHOUT CONSTRUCTION
Misc
Corrective Action Required
07/25/2024
Maintain erosion control throughout construction process
Misc
Informational
07/30/2024
Erosion control was in compliance at the time of inspection.
Underslab Electrical Inspection - Residential Passed 7/30/2024 07/30/2024
Water Service Inspection - R Passed 7/30/2024 07/30/2024
Misc
Informational
07/30/2024
1454 and 1456
Erosion Control Inspection Residential Partial 8/15/2024 08/15/2024
Misc
Resolved
08/15/2024
MAINTAIN EROSION CONTROL THROUGHOUT CONSTRUCTION
Misc
Resolved
08/15/2024
Maintain erosion control throughout construction process
Misc
Resolved
08/15/2024
Erosion control was in compliance at the time of inspection.
Misc
Corrective Action Required
08/15/2024
- EROSION CONTROL IN PLACE AT TIME OF INSPECION. 1454 & 1456
Underslab Plumbing Inspection - Residential Passed 8/15/2024 08/15/2024
Informational
08/15/2024
1454 & 1456 APPROVED
Suspended Slab Inspection Passed 9/13/2024 09/13/2024
Misc
Informational
09/13/2024
- INSPECTION BY THIRD PARTY, APEX BOTH 1454, 1456
Rated Assembly Inspection Partial 9/17/2024 9/17/2024 09/17/2024
THE FOLLOWING AREAS ARE APPROVED
Informational
09/17/2024
ABOVE CEILING ON BOTH SIDES.
Erosion Control Inspection Residential Partial 10/8/2024 10/08/2024
Misc
Resolved
10/08/2024
- EROSION CONTROL IN PLACE AT TIME OF INSPECION. 1454 & 1456
Miscellaneous Correction
Informational
10/08/2024
Full erosion control measures are in place and must be properly maintained until CofO
Rated Assembly Inspection Partial 10/17/2024 10/17/2024 10/17/2024
THE FOLLOWING AREAS ARE APPROVED
Informational
09/17/2024
ABOVE CEILING and RIM BOARD 1454 -Address missing double top plate at master bedroom Protect rafter at back of master bedroom 1456 - Protect gap above master bedroom - Seal gap back corner of rim board
Erosion Control Inspection Residential Partial 10/28/2024 10/28/2024 10/28/2024
Miscellaneous Correction
Informational
10/08/2024
Full erosion control measures are in place and must be properly maintained until CofO
Electrical Service Inspection Passed 10/28/2024 10/28/2024 10/28/2024
Gas Service Inspection - Residential Passed 10/28/2024 10/28/2024 10/28/2024
All Rough Inspection - Residential Failed 10/28/2024 10/28/2024 10/28/2024
Misc
Corrective Action Required
10/28/2024
**Location of 16” lvl support stud pack is wrong on the plan. Have engineer redraw 1454: -Nail ZIP sheathing to rear exterior wall studs per code. -Reinforce non-continuous studs at plate line of front bedroom gable wall -Fully nail hanger to lvl beam above basement stair -Install support device for header joists above transom window in basement -Staple north basement closet light wiring min 1.25” from nailing surface -Secure NM wiring at max 4.5 ft intervals within soffit framing -Fb basement bathroom wall from soffit -Protect plumbing at basement bathroom bottom&top wall plates with BOCA plates -Seal gap and penetration of joist return air space 1456: -Reinforce non-continuous studs at plate line of front bedroom gable wall -Fb front closet wall from roof -Protect wiring running across top of ceiling joists located within six ft of attic access -Install support device for header joists above transom window in basement -Staple south basement closet light wiring min 1.25” from nailing surface -Secure NM wiring at max 4.5 ft intervals within soffit framing -Identify feeder EGC and grounded conductors inside panel with proper color; isolate grounded bus bar from equipment grounding bus bar **OK TO INSULATE
Rated Assembly Inspection Failed 10/28/2024 10/28/2024 10/28/2024
THE FOLLOWING AREAS ARE APPROVED
Informational
10/17/2024
ABOVE CEILING and RIM BOARD 1454: -Close off gap at roof deck above garage; fire-caulk around penetrations of membrane (above master shower and at ridge; mud&tape seam above master bedroom -Extend 1-hr wall through soffit at front of garage 1456: -Close off hole in attic wall above master bathroom/bedroom corner; fire-caulk around penetrations of membrane at ridge -Extend 1-hr wall through soffit at front of garage
All Rough Inspection - Residential Failed 10/30/2024 10/30/2024 10/30/2024
Misc
Corrective Action Required
10/28/2024
1454: -Staple north basement closet light wiring min 1.25” from nailing surface -Protect plumbing at basement bathroom bottom&top wall plates with BOCA plates **protect the PVC at bottom wall plate per code -Seal gap and penetration of joist return air space above basement bathroom wall 1456: -Identify feeder EGC and grounded conductors inside panel with proper color; isolate grounded bus bar from equipment grounding bus bar **Tape the feeder EGC with green tape. Yellow tripe is not a proper identifier for EGC; remove the bar that connects the EGC bus bar and the neutral bus bar **OK TO INSULATE
Rated Assembly Inspection Partial 10/30/2024 10/30/2024 10/30/2024
THE FOLLOWING AREAS ARE APPROVED
Informational
10/28/2024
ABOVE CEILING and RIM BOARD ONLY: 1454: -Extend 1-hr wall through soffit at front of garage 1456: -Extend 1-hr wall through soffit at front of garage DWELLING SEPARATION:
Erosion Control Inspection Residential Partial 10/30/2024 10/30/2024 10/30/2024
Miscellaneous Correction
Informational
10/28/2024
Full erosion control measures are in place and must be properly maintained until CofO
All Rough Inspection - Residential Passed 11/1/2024 11/1/2024 11/01/2024
Misc
Informational
11/01/2024
BOTH 1454, 1456
Erosion Control Inspection Residential Partial 11/1/2024 11/01/2024
Miscellaneous Correction
Informational
10/30/2024
Full erosion control measures are in place at time of inspection.
Rated Assembly Inspection Partial 11/15/2024 11/15/2024 11/15/2024
THE FOLLOWING AREAS ARE APPROVED
Resolved
11/15/2024
ABOVE CEILING and RIM BOARD ONLY: 1454: -Extend 1-hr wall through soffit at front of garage 1456: -Extend 1-hr wall through soffit at front of garage DWELLING SEPARATION:
Misc
Corrective Action Required
11/15/2024
- Screw pattern approved both sides ready for tape and mud.
Rated Assembly Inspection Passed 11/18/2024 11/18/2024
Misc
Resolved
11/18/2024
- Screw pattern approved both sides ready for tape and mud.
Driveway Inspection Passed 2/4/2025 2/4/2025 02/07/2025
Misc
Informational
02/04/2025
2-4-25 BR Driveway is formed up and aggregate is place and compacted ready for concrete. 2-7-25 BR Driveway is constructed to LS specifications.
Sidewalk Inspection Passed 4/17/2025 4/17/2025 04/22/2025
Misc
Informational
04/17/2025
04-17-25 Jamie S, SW is formed, compacted and slopes are in compliance with city standards. 4-22-25 BR Sidewalk is constructed to LS specifications.
Sidewalk Inspection Passed 4/24/2025 4/24/2025 04/22/2025
Misc
Informational
04/17/2025
04-17-25 Jamie S, SW is formed, compacted and slopes are in compliance with city standards. 4-22-25 BR Sidewalk is constructed to LS specifications.
Occupancy Inspection - Codes Residential Failed 4/25/2025 4/25/2025 04/25/2025
Misc
Corrective Action Required
04/25/2025
Both sides -provide plans/design for retaining wall greater than 4’ -address pending driveway inspection -final grade and sod -uncover covered water meters for inspection -seal all exterior penetrations -seal top of A/c disconnect - 1454 -provide gfci and afci protection for circuits 36,38,40 1456 -provide gfci and afci protection for circuits 36,38,40
Sidewalk Inspection Partial 04/25/2025
Misc
Corrective Action Required
04/25/2025
4-25-25 RH. Sidewalk is missing at corner of Winthrop and Winthrop. Connection was not made due to utility box being in the way. Utility Box will need to be moved for sidewalk to be put in.
Occupancy Inspection - Codes Residential Ready for Temp CO 4/29/2025 4/29/2025 04/29/2025
Misc
Corrective Action Required
04/25/2025
Both sides -address pending driveway and sidewalk inspection -final grade and sod
Documents & Images
Date Uploaded File Type Document Name
03/14/2024 Application - Lot 55
03/14/2024 Plot Plan - Lot 55
03/14/2024 Tax Form - Lot 55
03/14/2024 Permit Set - Lot 55
03/18/2024 Permit Codes Residential Plan Review
03/20/2024 Permit Set - Lot 55
03/20/2024 Revision Letter - Lot 55_pages
03/20/2024 Plot Plan - Lot 55
03/21/2024 Permit Codes Residential Plan Review
03/22/2024 Permit Set - Lot 55
03/22/2024 Plot Plan - Lot 55
03/25/2024 Approved Plans APPROVED PLANS
03/25/2024 Approved Plans approved plot plan
03/25/2024 Permit Codes Residential Plan Review
04/02/2024 Permit DS Building Permit
04/02/2024 Receipt Receipt for transaction: 2024-002080
04/10/2024 Permit Set - Lot 55
04/10/2024 Approved Plans APPROVED PLANS
05/09/2024 Permit Set - Lot 55
05/09/2024 Approved Plans APPROVED REVISED PLANS
07/10/2024 Letter INSPECTION SUMMARY
07/10/2024 Letter INSPECTION SUMMARY
07/25/2024 Letter INSPECTION SUMMARY
07/30/2024 Letter INSPECTION SUMMARY
07/30/2024 Letter INSPECTION SUMMARY
07/30/2024 Letter INSPECTION SUMMARY
07/30/2024 Letter INSPECTION SUMMARY
07/30/2024 Letter INSPECTION SUMMARY
08/15/2024 Letter INSPECTION SUMMARY
08/15/2024 Letter INSPECTION SUMMARY
08/15/2024 Letter INSPECTION SUMMARY
08/29/2024 3RD Party Insp Report ENGINEER THIRD PARTY SUSPENDED SLAB EINSPECTION
09/13/2024 Letter INSPECTION SUMMARY
09/17/2024 Letter INSPECTION SUMMARY
10/08/2024 Letter INSPECTION SUMMARY
10/17/2024 Letter INSPECTION SUMMARY
10/28/2024 Letter INSPECTION SUMMARY
10/28/2024 Letter INSPECTION SUMMARY
10/28/2024 Letter INSPECTION SUMMARY
10/28/2024 Letter INSPECTION SUMMARY
10/28/2024 Letter INSPECTION SUMMARY
10/28/2024 Letter INSPECTION SUMMARY
10/29/2024 Approved Plans APPROVED REVISED PLANS
10/30/2024 Letter INSPECTION SUMMARY
10/30/2024 Letter INSPECTION SUMMARY
10/30/2024 Letter INSPECTION SUMMARY
11/01/2024 Letter INSPECTION SUMMARY
11/01/2024 Letter INSPECTION SUMMARY
11/15/2024 Letter INSPECTION SUMMARY
11/18/2024 Letter INSPECTION SUMMARY
02/04/2025 Letter INSPECTION SUMMARY
02/07/2025 Letter INSPECTION SUMMARY
02/07/2025 Letter INSPECTION SUMMARY
04/17/2025 Letter INSPECTION SUMMARY
04/22/2025 Letter INSPECTION SUMMARY
04/22/2025 Letter INSPECTION SUMMARY
04/22/2025 Letter INSPECTION SUMMARY
04/25/2025 Letter INSPECTION SUMMARY
04/25/2025 Letter INSPECTION SUMMARY
04/29/2025 Letter INSPECTION SUMMARY
04/29/2025 Certificate/License Codes Temporary Certificate of Occupancy
04/29/2025 Receipt Receipt for transaction:2025-002689
05/06/2025 As Grade Plot Plan - Lot 55
05/07/2025 Plot Plan APPROVED AS GRADED PLOT PLAN
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home