Permit Application Status

PRRES20236296


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20236296
Building Permit - Residential
Certificate of Occupancy
NEW DUPLEX
NEW DUPLEX - UNCOVERED DECK - ROOF TRUSSES STOP WORK ORDER generated on 04/19/2024 12:00 AM by username 'Dustin Agcopra'. STOP WORK ORDER removed on 04/23/2024 12:00 AM by username 'Dustin Agcopra'.
11/30/2023
12/06/2023
09/16/2024
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
BRUCER@SUMMITHOMESKC.COM  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
CARUTHERS ELECTRICAL LLC, Address:30905 E TRUMAN RD, Phone:(816) 508-9050  
BILL'S PLUMBING SERVICE LLC, Address:308 E PARK STREET, Phone:(913) 829-8213  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee for New Duplex $1,925.36 $1,925.36 Paid 12/06/2023
Sanitary Sewer Development Fee $4,318.00 $4,318.00 Paid 12/06/2023
Right of Way Permit Fee $85.00 $85.00 Paid 12/06/2023
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 12/06/2023
Water Tap Fee $7,520.00 $7,520.00 Paid 12/06/2023
Water Meter Fee $1,360.92 $1,360.92 Paid 12/06/2023
Residential Excise Tax Fee $217.60 $217.60 Paid 01/02/2024
$1,240.32
Temporary Occupancy Fee $50.00 $50.00 Paid 06/06/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 08/06/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 08/12/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 09/11/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 1/2/2024 01/02/2024
Miscellaneous Correction
Informational
01/02/2024
Footing passed by a third party. Footing inspection did not mention any piers.
Sewer Service Inspection - R Passed 1/18/2024 (10:30) 1/18/2024 01/18/2024
Erosion Control Inspection Residential Partial 1/18/2024 01/18/2024
Miscellaneous Correction
Informational
01/18/2024
Erosion control is in place at the time of sewer inspection. Full erosion control must be maintained until full CofO.
Water Service Inspection - R Partial 1/23/2024 1/23/2024 01/23/2024
Miscellaneous Correction
Informational
01/23/2024
2124 SW Holdbrooks water passed. This is a partial pass only.
Water Service Inspection - R Passed 1/24/2024 01/24/2024
Miscellaneous Correction
Informational
01/23/2024
2124 SW Holdbrooks water passed. This is a partial pass only.
Miscellaneous Correction
Informational
01/24/2024
Water on both sides to the duplex passed
Underslab Plumbing Inspection - Residential Passed 2/1/2024 2/1/2024 02/01/2024
Erosion Control Inspection Residential Partial 2/1/2024 02/01/2024
Miscellaneous Correction
Informational
01/18/2024
Erosion control is in place at the time of sewer inspection. Full erosion control must be maintained until full CofO.
Miscellaneous Correction
Informational
02/01/2024
Full erosion control is in place and needs to be maintained until CofO
Erosion Control Inspection Residential Partial 2/12/2024 02/12/2024
Miscellaneous Correction
Informational
02/01/2024
Erosion control is in place at the time of sewer inspection. Full erosion control must be maintained until full CofO.
Miscellaneous Correction
Informational
02/01/2024
Full erosion control is in place and needs to be maintained until CofO
Miscellaneous Correction
Informational
02/12/2024
Full erosion control is in place and must be maintained until full CofO
Erosion Control Inspection Residential Partial 2/29/2024 02/29/2024
Miscellaneous Correction
Informational
02/12/2024
Erosion control is in place at the time of sewer inspection. Full erosion control must be maintained until full CofO.
Miscellaneous Correction
Informational
02/12/2024
Full erosion control is in place and needs to be maintained until CofO
Miscellaneous Correction
Informational
02/12/2024
Full erosion control is in place and must be maintained until full CofO
Miscellaneous Correction
Informational
02/29/2024
Full erosion control is in place and must be maintained until full CofO
All Rough Inspection - Residential Partial 2/29/2024 2/29/2024 02/29/2024
Misc
Corrective Action Required
02/29/2024
- PORTAL FRAME OK TO COVER
Rated Assembly Inspection Failed 3/13/2024 3/13/2024 03/13/2024
Miscellaneous Correction
Corrective Action Required
03/13/2024
2124 and 2122 SW Holdbrooks rated assembly 2124 (east side) Fire blocking plywood needs to extend out 4 feet from the rated assembly wall Roof vent is within 4 feet of the rated wall assembly Bedroom west wall above garage needs to be of fire rated construction (less than 4 feet from fire wall Fire rated plywood at ridge above upstairs bathroom has a gap greater the 1/4 of an inch 2122 (west side) Bedroom east wall above garage needs to be of fire rated construction (less than 4 feet from fire wall Fire blocking plywood needs to extend out 4 feet from the rated assembly wall Roof vent is within 4 feet of the rated wall assembly
Gas Service Inspection - Residential Failed 3/13/2024 3/13/2024 03/13/2024
Miscellaneous Correction
Corrective Action Required
03/13/2024
Gas gauges are not installed
Electrical Service Inspection Failed 3/13/2024 3/13/2024 03/13/2024
Miscellaneous Correction
Corrective Action Required
03/13/2024
Ufer is not utilized in west side unit 2122 at electrical panel
All Rough Inspection - Residential Failed 3/13/2024 3/13/2024 03/13/2024
Misc
Corrective Action Required
02/29/2024
- PORTAL FRAME OK TO COVER
Miscellaneous Correction
Corrective Action Required
03/13/2024
2122 and 2124 SW Holdbrooks (all rough) 2122 (west side) have engineers letter for garage ceiling joist being notched in the upper 2 inches for plumbing 2 feet from the party wall Garage attic access does not have 30 inches of headroom clearance Garage and entry attic space is not vented Bottom cord of trusses in the great room to back patio are over 4 feet in length and need to have joist hangers installed Bottom cord of trusses in bedroom 1 are over 4 feet in length and need joist hangers installed Attic access in bedroom 1 has a light in the 30 inches of head room Nail off corner in bedroom 3 Attic accessible is not installed Nail corner in bedroom 2 Electrical panel is not attached to this unit’s UFER Bedroom above garage needs to be fire blocked within 4 feet of party wall 2124 (east side) Attic space above garage and entry needs to be vented Bedroom above garage needs no be fire blocked within 4 feet of party wall Garage attic access hatch does not have the required head room height Fire block hole in top plate in garage Ottom truss cords in bedroom 1 and great room need joist hangers installed. Cords are over 4 feet in length Half of double truss in bedroom 1 is not nailed together Top of chase in bathroom 1 needs to be fire blocked Nail corners throughout truss tie down screw is needed in closet in bedroom 3 Fire block top of upstairs bathroom chase on both units Engineers letter is needed for over bored floor joint in basement for plumbing waste line
Erosion Control Inspection Residential Partial 3/14/2024 03/14/2024
Miscellaneous Correction
Informational
02/29/2024
Erosion control is in place at the time of sewer inspection. Full erosion control must be maintained until full CofO.
Miscellaneous Correction
Informational
02/29/2024
Full erosion control is in place and needs to be maintained until CofO
Miscellaneous Correction
Informational
02/29/2024
Full erosion control is in place and must be maintained until full CofO
Miscellaneous Correction
Informational
02/29/2024
Full erosion control is in place and must be maintained until full CofO
Miscellaneous Correction
Informational
03/14/2024
Full erosion control is in place and must be maintained until full CofO
Gas Service Inspection - Residential Passed 3/19/2024 3/19/2024 03/19/2024
Miscellaneous Correction
Resolved
03/19/2024
Gas gauges are not installed
Electrical Service Inspection Passed 3/19/2024 3/19/2024 03/19/2024
Miscellaneous Correction
Resolved
03/19/2024
Ufer is not utilized in west side unit 2122 at electrical panel
Rated Assembly Inspection Failed 3/19/2024 3/19/2024 03/19/2024
Miscellaneous Correction
Corrective Action Required
03/13/2024
2124 and 2122 SW Holdbrooks rated assembly 2124 (east side) Fire blocking plywood needs to extend out 4 feet from the rated assembly wall Roof vent is within 4 feet of the rated wall assembly Bedroom west wall above garage needs to be of fire rated construction (less than 4 feet from fire wall Fire rated plywood at ridge above upstairs bathroom has a gap greater the 1/4 of an inch 2122 (west side) Bedroom east wall above garage needs to be of fire rated construction (less than 4 feet from fire wall Fire blocking plywood needs to extend out 4 feet from the rated assembly wall Roof vent is within 4 feet of the rated wall assembly
All Rough Inspection - Residential Failed 3/19/2024 3/19/2024 03/19/2024
Misc
Corrective Action Required
03/13/2024
- PORTAL FRAME OK TO COVER
Miscellaneous Correction
Corrective Action Required
03/13/2024
2122 and 2124 SW Holdbrooks (all rough) 2122 (west side) have engineers letter for garage ceiling joist being notched in the upper 2 inches for plumbing 2 feet from the party wall Garage attic access does not have 30 inches of headroom clearance Garage and entry attic space is not vented Bottom cord of trusses in the great room to back patio are over 4 feet in length and need to have joist hangers installed Bottom cord of trusses in bedroom 1 are over 4 feet in length and need joist hangers installed Attic access in bedroom 1 has a light in the 30 inches of head room Nail off corner in bedroom 3 Attic accessible is not installed Nail corner in bedroom 2 Electrical panel is not attached to this unit’s UFER Bedroom above garage needs to be fire blocked within 4 feet of party wall 2124 (east side) Attic space above garage and entry needs to be vented Bedroom above garage needs no be fire blocked within 4 feet of party wall Garage attic access hatch does not have the required head room height Fire block hole in top plate in garage Ottom truss cords in bedroom 1 and great room need joist hangers installed. Cords are over 4 feet in length Half of double truss in bedroom 1 is not nailed together Top of chase in bathroom 1 needs to be fire blocked Nail corners throughout truss tie down screw is needed in closet in bedroom 3 Fire block top of upstairs bathroom chase on both units Engineers letter is needed for over bored floor joint in basement for plumbing waste line
Rated Assembly Inspection Passed 3/21/2024 3/21/2024 03/21/2024
Miscellaneous Correction
Resolved
03/21/2024
2124 and 2122 SW Holdbrooks rated assembly 2124 (east side) Fire blocking plywood needs to extend out 4 feet from the rated assembly wall Roof vent is within 4 feet of the rated wall assembly Bedroom west wall above garage needs to be of fire rated construction (less than 4 feet from fire wall Fire rated plywood at ridge above upstairs bathroom has a gap greater the 1/4 of an inch 2122 (west side) Bedroom east wall above garage needs to be of fire rated construction (less than 4 feet from fire wall Fire blocking plywood needs to extend out 4 feet from the rated assembly wall Roof vent is within 4 feet of the rated wall assembly
All Rough Inspection - Residential Failed 3/21/2024 3/21/2024 03/21/2024
Misc
Corrective Action Required
03/19/2024
- PORTAL FRAME OK TO COVER
Miscellaneous Correction
Corrective Action Required
03/19/2024
2122 and 2124 SW Holdbrooks (all rough) 2122 (west side) have engineers letter for garage ceiling joist being notched in the upper 2 inches for plumbing 2 feet from the party wall Garage attic access does not have 30 inches of headroom clearance Garage and entry attic space is not vented Bottom cord of trusses in the great room to back patio are over 4 feet in length and need to have joist hangers installed Bottom cord of trusses in bedroom 1 are over 4 feet in length and need joist hangers installed Attic access in bedroom 1 has a light in the 30 inches of head room Nail off corner in bedroom 3 Attic accessible is not installed Nail corner in bedroom 2 Electrical panel is not attached to this unit’s UFER Bedroom above garage needs to be fire blocked within 4 feet of party wall 2124 (east side) Attic space above garage and entry needs to be vented Bedroom above garage needs no be fire blocked within 4 feet of party wall Garage attic access hatch does not have the required head room height Fire block hole in top plate in garage Ottom truss cords in bedroom 1 and great room need joist hangers installed. Cords are over 4 feet in length Half of double truss in bedroom 1 is not nailed together Top of chase in bathroom 1 needs to be fire blocked Nail corners throughout truss tie down screw is needed in closet in bedroom 3 Fire block top of upstairs bathroom chase on both units Engineers letter is needed for over bored floor joint in basement for plumbing waste line
All Rough Inspection - Residential Passed 3/22/2024 3/22/2024 03/22/2024
Misc
Corrective Action Required
03/21/2024
2018 IFC 3310.1 Required access. Approved vehicle access for fire fighting shall be provided to all construction or demolition sites. Vehicle access shall be provided to within 100 feet (30 480mm) of temporary or permanent fire department connections. Vehicle access shall be provided by either temporary or permanent roads, capable of supporting vehicle loading under all weather conditions. Vehicle access shall be maintained until permanent fire apparatus access roads are available. -------------------------------------- - PORTAL FRAME OK TO COVER
Miscellaneous Correction
Corrective Action Required
03/21/2024
2122 and 2124 SW Holdbrooks (all rough) 2122 (west side) have engineers letter for garage ceiling joist being notched in the upper 2 inches for plumbing 2 feet from the party wall Garage attic access does not have 30 inches of headroom clearance Garage and entry attic space is not vented Bottom cord of trusses in the great room to back patio are over 4 feet in length and need to have joist hangers installed Bottom cord of trusses in bedroom 1 are over 4 feet in length and need joist hangers installed Attic access in bedroom 1 has a light in the 30 inches of head room Nail off corner in bedroom 3 Attic accessible is not installed Nail corner in bedroom 2 Electrical panel is not attached to this unit’s UFER Bedroom above garage needs to be fire blocked within 4 feet of party wall 2124 (east side) Attic space above garage and entry needs to be vented Bedroom above garage needs no be fire blocked within 4 feet of party wall Garage attic access hatch does not have the required head room height Fire block hole in top plate in garage Ottom truss cords in bedroom 1 and great room need joist hangers installed. Cords are over 4 feet in length Half of double truss in bedroom 1 is not nailed together Top of chase in bathroom 1 needs to be fire blocked Nail corners throughout truss tie down screw is needed in closet in bedroom 3 Fire block top of upstairs bathroom chase on both units Engineers letter is needed for over bored floor joint in basement for plumbing waste line
Miscellaneous Correction
Corrective Action Required
03/21/2024
Roof ventilation holes in the 4 foot from party wall has been filled and now the main floor areas do not have enough ventilation per square feet (1/150)
Erosion Control Inspection Residential Failed 4/3/2024 04/03/2024
Miscellaneous Correction
Informational
03/14/2024
Erosion control is in place at the time of sewer inspection. Full erosion control must be maintained until full CofO.
Miscellaneous Correction
Informational
03/14/2024
Full erosion control is in place and needs to be maintained until CofO
Miscellaneous Correction
Informational
03/14/2024
Full erosion control is in place and must be maintained until full CofO
Miscellaneous Correction
Informational
03/14/2024
Full erosion control is in place and must be maintained until full CofO
Miscellaneous Correction
Informational
03/14/2024
Full erosion control is in place and must be maintained until full CofO
Miscellaneous Correction
Corrective Action Required
04/03/2024
Erosion control at the street is torn, blown down or damaged and no long serves its intended purpose. Full erosion control must be maintained until CofO
Driveway Inspection Partial 4/10/2024 4/10/2024 04/10/2024
Misc
Informational
04/10/2024
4-10-24 Dustin A, DW is formed to city specs, Approved to pour
Sidewalk Inspection Partial 4/10/2024 4/10/2024 04/10/2024
Misc
Informational
04/10/2024
4-10-24 Dustin A, SW is formed to city specs. Will need to maintain ADA compliance, Approved to pour
Erosion Control Inspection Residential Partial 04/17/2024
Miscellaneous Correction
Informational
04/03/2024
Erosion control is in place at the time of sewer inspection. Full erosion control must be maintained until full CofO.
Miscellaneous Correction
Informational
04/03/2024
Full erosion control is in place and needs to be maintained until CofO
Miscellaneous Correction
Informational
04/03/2024
Full erosion control is in place and must be maintained until full CofO
Miscellaneous Correction
Informational
04/03/2024
Full erosion control is in place and must be maintained until full CofO
Miscellaneous Correction
Informational
04/03/2024
Full erosion control is in place and must be maintained until full CofO
Miscellaneous Correction
Corrective Action Required
04/03/2024
Erosion control at the street is torn, blown down or damaged and no long serves its intended purpose. Full erosion control must be maintained until CofO
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
04/17/2024
4-17-24 Dustin A. EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Erosion Control Inspection Residential Failed - Stop Work 4/19/2024 4/19/2024 04/19/2024
Miscellaneous Correction
Informational
04/17/2024
Erosion control is in place at the time of sewer inspection. Full erosion control must be maintained until full CofO.
Miscellaneous Correction
Informational
04/17/2024
Full erosion control is in place and needs to be maintained until CofO
Miscellaneous Correction
Informational
04/17/2024
Full erosion control is in place and must be maintained until full CofO
Miscellaneous Correction
Informational
04/17/2024
Full erosion control is in place and must be maintained until full CofO
Miscellaneous Correction
Informational
04/17/2024
Full erosion control is in place and must be maintained until full CofO
Miscellaneous Correction
Corrective Action Required
04/17/2024
Erosion control at the street is torn, blown down or damaged and no long serves its intended purpose. Full erosion control must be maintained until CofO
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
04/17/2024
4-17-24 Dustin A. EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
04/19/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. 4-19-24 Dustin A, Still no erosion control in place
Erosion Control Inspection Residential Passed 04/23/2024
Miscellaneous Correction
Informational
04/19/2024
Erosion control is in place at the time of sewer inspection. Full erosion control must be maintained until full CofO.
Miscellaneous Correction
Informational
04/19/2024
Full erosion control is in place and needs to be maintained until CofO
Miscellaneous Correction
Informational
04/19/2024
Full erosion control is in place and must be maintained until full CofO
Miscellaneous Correction
Informational
04/19/2024
Full erosion control is in place and must be maintained until full CofO
Miscellaneous Correction
Informational
04/19/2024
Full erosion control is in place and must be maintained until full CofO
Miscellaneous Correction
Corrective Action Required
04/19/2024
Erosion control at the street is torn, blown down or damaged and no long serves its intended purpose. Full erosion control must be maintained until CofO
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
04/19/2024
4-17-24 Dustin A. EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
04/19/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. 4-19-24 Dustin A, Still no erosion control in place
Driveway Inspection Partial 4/19/2024 04/23/2024
Misc
Informational
04/10/2024
4-10-24 Dustin A, DW is formed to city specs, Approved to pour 4-23-24 Dustin A, DW is poured to city specs, cannot pass until forms pulled
Sidewalk Inspection Partial 4/19/2024 04/23/2024
Misc
Informational
04/10/2024
4-10-24 Dustin A, SW is formed to city specs. Will need to maintain ADA compliance, Approved to pour 4-23-24 Dustin A, SW poured to city specs, cannot pass until forms pulled
Piers/Caissons Inspection - Residential Partial 5/20/2024 5/20/2024 05/20/2024
Miscellaneous Correction
Informational
05/20/2024
- Piers at 2124 passed. Piers at 2122 were not ready for inspection. - ok to pour piers at 2124 only This is a partial pass only
Piers/Caissons Inspection - Residential Passed 5/28/2024 05/28/2024
Miscellaneous Correction
Resolved
05/28/2024
- Piers at 2124 passed. Piers at 2122 were not ready for inspection. - ok to pour piers at 2124 only This is a partial pass only
Occupancy Inspection - Codes Residential Failed 5/30/2024 5/30/2024 05/30/2024
Miscellaneous Correction
Corrective Action Required
05/30/2024
2122 and 2124 SW Holdbrooks. Occupancy 2122 Front porch guard rail height from the concrete to the bottom rail is over the code 4 inches from the surface First step up from the entry to the stairs has a greater than 7 3/4 inches code required riser height Back porch security lights are only 89 inches in height Back porch base stair landing is not installed Back porch needs a hand rail installed to code Remove dust covers from ceiling mounted detectors Fire block all holes in garage at over head garage door to ceiling Seal all gaps under chase in garage Stairwell to basement does not have the code required 6’8” of head clearance height near the bottom Hot water heater needs a lock out installed at the electrical panel Test button on breaker #17 does not work 2124 Bottom rail of front porch guard rail is over 4 inches in height. Code is no more than 4 inches Entry to first step up stairs has a riser height of greater than the code allowance of 7 3/4 inches Back porch GFCI does not trip Back porch security light is not at least 8 feet off the floor surface Back porch base of stair landing is not installed Fire block all holes in garage at overhead door to ceiling Seal the bottom sides of the chase in the garage Basement step to main entry has a greater riser height than the code allowable 7 3/4 inches Stairwell to the basement does not have the code required head height of 6’8” near the bottom of the stairs Attic access panel is not installed in the upper floor Exterior electrical box needs a cover installed Seal exterior penetration at the gas line to siding Both units Driveway and sidewalk finals needs to pass sod, splash pads and sump pump extensions are not installed Final grading is not done for a plot plan inspection
Driveway Inspection Passed 6/5/2024 6/5/2024 06/05/2024
Misc
Informational
04/23/2024
4-10-24 Dustin A, DW is formed to city specs, Approved to pour 4-23-24 Dustin A, DW is poured to city specs, cannot pass until forms pulled 6-5-24 Dustin A, Forms have been pulled. Passed
Sidewalk Inspection Passed 6/5/2024 6/5/2024 06/05/2024
Misc
Informational
04/23/2024
4-10-24 Dustin A, SW is formed to city specs. Will need to maintain ADA compliance, Approved to pour 4-23-24 Dustin A, SW poured to city specs, cannot pass until forms pulled 6-5-24 Dustin A, Forms have been pulled
Occupancy Inspection - Codes Residential Failed 6/5/2024 6/5/2024 06/05/2024
Miscellaneous Correction
Resolved
06/05/2024
2122 and 2124 SW Holdbrooks. Occupancy 2122 Front porch guard rail height from the concrete to the bottom rail is over the code 4 inches from the surface First step up from the entry to the stairs has a greater than 7 3/4 inches code required riser height Back porch security lights are only 89 inches in height Back porch base stair landing is not installed Back porch needs a hand rail installed to code Remove dust covers from ceiling mounted detectors Fire block all holes in garage at over head garage door to ceiling Seal all gaps under chase in garage Stairwell to basement does not have the code required 6’8” of head clearance height near the bottom Hot water heater needs a lock out installed at the electrical panel Test button on breaker #17 does not work 2124 Bottom rail of front porch guard rail is over 4 inches in height. Code is no more than 4 inches Entry to first step up stairs has a riser height of greater than the code allowance of 7 3/4 inches Back porch GFCI does not trip Back porch security light is not at least 8 feet off the floor surface Back porch base of stair landing is not installed Fire block all holes in garage at overhead door to ceiling Seal the bottom sides of the chase in the garage Basement step to main entry has a greater riser height than the code allowable 7 3/4 inches Stairwell to the basement does not have the code required head height of 6’8” near the bottom of the stairs Attic access panel is not installed in the upper floor Exterior electrical box needs a cover installed Seal exterior penetration at the gas line to siding Both units Driveway and sidewalk finals needs to pass sod, splash pads and sump pump extensions are not installed Final grading is not done for a plot plan inspection
Miscellaneous Correction
Corrective Action Required
06/05/2024
2122 and 2124 SW Holdbrooks. Occupancy (2) 2122 First step up from the entry to the stairs has a greater than 7 3/4 inches code required riser height Test button on breaker #17 does not work 2124 Entry to first step up stairs has a riser height of greater than the code allowance of 7 3/4 inches Seal the bottom sides of the chase in the garage Both units sod, splash pads and sump pump extensions are not installed Final grading is not done for a plot plan inspection
Occupancy Inspection - Codes Residential Ready for Temp CO 6/6/2024 6/6/2024 06/06/2024
Miscellaneous Correction
Resolved
06/06/2024
2122 and 2124 SW Holdbrooks. Occupancy (2) 2122 First step up from the entry to the stairs has a greater than 7 3/4 inches code required riser height Test button on breaker #17 does not work 2124 Entry to first step up stairs has a riser height of greater than the code allowance of 7 3/4 inches Seal the bottom sides of the chase in the garage Both units sod, splash pads and sump pump extensions are not installed Final grading is not done for a plot plan inspection
Miscellaneous Correction
Corrective Action Required
06/06/2024
Both units sod, splash pads and sump pump extensions are not installed Final grading is not done for a plot plan inspection Both units passed for TCO only
Erosion Control Inspection Residential Failed 7/15/2024 07/15/2024
Miscellaneous Correction
Corrective Action Required
07/15/2024
Full erosion control measures are not in place Full erosion control must be maintained until CofO
Plot Plan Inspection Failed 7/15/2024 07/15/2024
Miscellaneous Correction
Corrective Action Required
07/15/2024
Plot has not been final graded for a plot plan inspection
Occupancy Inspection - Codes Residential Not Ready 7/18/2024 07/18/2024
Miscellaneous Correction
Resolved
07/18/2024
Both units sod, splash pads and sump pump extensions are not installed Final grading is not done for a plot plan inspection Both units passed for TCO only
Miscellaneous Correction
Corrective Action Required
07/18/2024
Both units sod, splash pads and sump pump extensions are not installed Final grading is not done for a plot plan inspection Both units passed for TCO only Emailed builder asking for a TCO extension form to be submitted. No reply was ever submitted Not ready
Occupancy Inspection - Codes Residential Ready for Temp CO 8/6/2024 08/06/2024
Miscellaneous Correction
Corrective Action Required
07/18/2024
Both units sod, splash pads and sump pump extensions are not installed Final grading is not done for a plot plan inspection Both units passed for TCO only Emailed builder asking for a TCO extension form to be submitted. No reply was ever submitted Not ready
Occupancy Inspection - Codes Residential Failed 9/6/2024 09/06/2024
Miscellaneous Correction
Corrective Action Required
08/06/2024
Both units sod, splash pads and sump pump extensions are not installed Final grading is not done for a plot plan inspection Both units passed for TCO only Emailed builder asking for a TCO extension form to be submitted. No reply was ever submitted Not ready
Miscellaneous Correction
Corrective Action Required
09/06/2024
-Irrigation permit is required for unit 2124 -Splash pads and sump pump extensions are not installed -Raise water meter to yard height on unit 2124
Plot Plan Inspection Passed 9/6/2024 09/06/2024
Miscellaneous Correction
Resolved
09/06/2024
Plot has not been final graded for a plot plan inspection
Erosion Control Inspection Residential Passed 9/6/2024 09/06/2024
Miscellaneous Correction
Resolved
09/06/2024
Full erosion control measures are not in place Full erosion control must be maintained until CofO
Occupancy Inspection - Codes Residential Ready for Temp CO 9/11/2024 09/11/2024
Miscellaneous Correction
Resolved
09/11/2024
Both units sod, splash pads and sump pump extensions are not installed Final grading is not done for a plot plan inspection Both units passed for TCO only Emailed builder asking for a TCO extension form to be submitted. No reply was ever submitted Not ready
Miscellaneous Correction
Resolved
09/11/2024
-Irrigation permit is required for unit 2124 -Splash pads and sump pump extensions are not installed -Raise water meter to yard height on unit 2124
Miscellaneous Correction
Corrective Action Required
09/11/2024
Irrigation permit is required for unit 2124 -Splash pads and sump pump extensions are not installed -Raise water meter to yard height on unit 2124 Builder sent in their 2nd TCO extension request. Builder is actively working on their building final. Be sure to look over the list of corrections before scheduling your final building inspection for CofO
Occupancy Inspection - Codes Residential Failed 9/16/2024 9/16/2024 09/16/2024
Miscellaneous Correction
Corrective Action Required
09/11/2024
Irrigation permit is required for unit 2124 All completed except for irrigation permit
Occupancy Inspection - Codes Residential Full C of O 9/16/2024 09/16/2024
Miscellaneous Correction
Resolved
09/16/2024
Irrigation permit is required for unit 2124 All completed except for irrigation permit
Documents & Images
Date Uploaded File Type Document Name
11/30/2023 OS # 77 - CERTIFIED PLANS
11/30/2023 OS # 77 - PERMIT APP
11/30/2023 OS # 77 - PLOT PLAN
11/30/2023 OS # 77 - TRUSS DETAILS
11/30/2023 OS # 77 - TRUSS LAYOUT
12/06/2023 Permit Codes Residential Plan Review
12/06/2023 Plot Plan approved plot plan
12/06/2023 Approved Plans APPROVED TRUSS LAYOUT
12/06/2023 Approved Plans APPROVED TRUSS PACKAGE
12/06/2023 Permit DS Building Permit
12/06/2023 Receipt Receipt for transaction:2023-008929
12/31/2023 2122 & 2124 SW Holdbrooks Dr LSMO Osage Lot 77 3rd Party Footing Inspection Report 12-29-23
01/02/2024 Letter INSPECTION SUMMARY
01/02/2024 Receipt Receipt for transaction:2024-000023
01/18/2024 Letter INSPECTION SUMMARY
01/18/2024 Letter INSPECTION SUMMARY
01/23/2024 Letter INSPECTION SUMMARY
01/24/2024 Letter INSPECTION SUMMARY
02/01/2024 Letter INSPECTION SUMMARY
02/01/2024 Letter INSPECTION SUMMARY
02/05/2024 Approved Plans APPROVED REVISED PLANS
02/12/2024 Letter INSPECTION SUMMARY
02/29/2024 Letter INSPECTION SUMMARY
02/29/2024 Letter INSPECTION SUMMARY
02/29/2024 Letter INSPECTION SUMMARY
03/13/2024 Letter INSPECTION SUMMARY
03/13/2024 Letter INSPECTION SUMMARY
03/13/2024 Letter INSPECTION SUMMARY
03/13/2024 Letter INSPECTION SUMMARY
03/14/2024 Letter INSPECTION SUMMARY
03/14/2024 Letter Codes Residential Plan Review
03/19/2024 Letter INSPECTION SUMMARY
03/19/2024 Letter INSPECTION SUMMARY
03/21/2024 Letter INSPECTION SUMMARY
03/21/2024 Letter INSPECTION SUMMARY
03/21/2024 Letter INSPECTION SUMMARY
04/03/2024 Letter INSPECTION SUMMARY
04/03/2024 Letter INSPECTION SUMMARY
04/03/2024 Letter INSPECTION SUMMARY
04/10/2024 Letter INSPECTION SUMMARY
04/10/2024 Letter INSPECTION SUMMARY
04/17/2024 Letter INSPECTION SUMMARY
04/19/2024 Letter Stop Work Order
04/19/2024 Letter Stop Work Order
04/23/2024 Letter INSPECTION SUMMARY
04/23/2024 Letter INSPECTION SUMMARY
04/23/2024 Letter INSPECTION SUMMARY
05/20/2024 Letter INSPECTION SUMMARY
05/28/2024 Letter INSPECTION SUMMARY
05/30/2024 Letter INSPECTION SUMMARY
06/05/2024 Letter INSPECTION SUMMARY
06/05/2024 Letter INSPECTION SUMMARY
06/05/2024 Letter INSPECTION SUMMARY
06/06/2024 Certificate/License Codes Temporary Certificate of Occupancy
06/06/2024 Receipt Receipt for transaction:2024-004453
07/15/2024 Letter INSPECTION SUMMARY
07/15/2024 Letter INSPECTION SUMMARY
07/18/2024 Letter INSPECTION SUMMARY
08/06/2024 Receipt Receipt for transaction:2024-006615
08/06/2024 Application Form TCO EXTENSION REQUEST
08/12/2024 Certificate/License Codes Temporary Certificate of Occupancy
08/12/2024 Receipt Receipt for transaction:2024-006776
09/06/2024 Letter INSPECTION SUMMARY
09/06/2024 Letter INSPECTION SUMMARY
09/06/2024 Letter INSPECTION SUMMARY
09/06/2024 Letter INSPECTION SUMMARY
09/11/2024 OS #77 - TCO Extension Request Form
09/11/2024 Letter INSPECTION SUMMARY
09/11/2024 Certificate/License Codes Temporary Certificate of Occupancy
09/11/2024 Receipt Receipt for transaction:2024-007621
09/16/2024 Letter INSPECTION SUMMARY
09/16/2024 Letter Field Certificate of Occupancy
09/16/2024 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home