Summary
PRRES20215064
Building Permit - Residential
Certificate of Occupancy
CLAYTON PROPERTIES GROUP INC
NEW 3 OR 4 FAMILY
NEW FOUR PLEX - FINISHED AND UNFINISHED BASEMENT - UNCOVERED DECK - ROOF TRUSSES
09/28/2021
10/05/2021
03/28/2022
10/17/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CLAYTON PROPERTIES GROUP INC, Address:120 SE 30TH ST  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for New 3 or 4 Family $4,745.87 $4,745.87 Paid 10/05/2021
8331507-Sewer Connection Fee $1,440.00 $1,440.00 Paid 10/05/2021
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 10/05/2021
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 10/05/2021
8331401-Water Tap Fee $14,620.00 $14,620.00 Paid 10/05/2021
8350015-Water Meter Fee $1,916.96 $1,916.96 Paid 10/05/2021
8331504-EFHB Middle Big Creek, Full $1,607.04 $1,607.04 Paid 10/05/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 09/12/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 09/12/2022
9110080-3rd and Subsequent Inspection Fee (Per Hour) $200.00 $200.00 Paid 09/12/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 09/13/2022
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 10/05/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 10/11/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 11/29/2021 11/29/2021 11/29/2021
Misc
Informational
11/29/2021
Ufer ground rods are located in the back garage walls as indicated on the third party inspection.
Underslab Plumbing Inspection - Residential Passed 12/22/2021 12/22/2021 12/22/2021
Sewer Service Inspection - R Partial 5/9/2022 (10:15) 5/9/2022 05/09/2022
Misc
Corrective Action Required
05/09/2022
3711, 3713 OK
Sewer Service Inspection - R Partial 5/10/2022 (9:00) 5/10/2022 05/10/2022
Misc
Corrective Action Required
05/09/2022
3711, 3713, 3715 OK
Sewer Service Inspection - R Passed 5/10/2022 05/10/2022
Misc
Corrective Action Required
05/10/2022
3711, 3713, 3715,3717 OK
Water Service Inspection - R Partial 5/12/2022 (9:45) 5/12/2022 05/12/2022
Erosion Control Inspection Residential Failed 05/12/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
05/12/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Electrical Service Inspection Failed 5/24/2022 5/24/2022 05/24/2022
Misc
Corrective Action Required
05/24/2022
COMPLETE ELECTRICAL
Gas Service Inspection - Residential Failed 5/24/2022 5/24/2022 05/24/2022
Misc
Corrective Action Required
05/24/2022
COMPLETE GAS
All Rough Inspection - Residential Failed 5/24/2022 5/24/2022 05/24/2022
Misc
Corrective Action Required
05/24/2022
UNIT 3717: -Fireblock HVAC at garage entry closet -provide solid blocking between studs at party rated wall 7.5’ per engineer letter -seal top and bottom plate penetrations at great room -nail joist hangers at foyer -seal top plate penetrations for DWV, 2nd floor hall -seal unused top plate bore 2nd floor bedroom -nail off corner strap 2nd floor bedroom exterior wall -provide joist hangers at floor joists 4’ or more at basement mech sump pump area -provide joist hanger at joist to header connection above furnace - The fire rated wall separating townhouses shall be continuous from foundation to the underside of roof sheathing, fire rating shall extend the full length of wall or assembly, IRC R302.2.3 NO INSPECTION PERFORMED ON UNITS 3711, 3713, 3715
Rated Assembly Inspection Failed 5/24/2022 5/24/2022 05/24/2022
Misc
Corrective Action Required
05/24/2022
UNIT 3717: - The fire rated wall separating townhouses shall be continuous from foundation to the underside of roof sheathing, fire rating shall extend the full length of wall or assembly, IRC R302.2.3 NO INSPECTION PERFORMED ON UNITS 3711, 3713, 3715
Erosion Control Inspection Residential Failed 5/24/2022 5/24/2022 05/24/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
05/12/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
All Rough Inspection - Residential Not Ready 5/26/2022 5/26/2022 05/26/2022
Misc
Corrective Action Required
05/24/2022
5/26/22 NOT READY UNIT 3717: -Fireblock HVAC at garage entry closet -provide solid blocking between studs at party rated wall 7.5’ per engineer letter -seal top and bottom plate penetrations at great room -nail joist hangers at foyer -seal top plate penetrations for DWV, 2nd floor hall -seal unused top plate bore 2nd floor bedroom -nail off corner strap 2nd floor bedroom exterior wall -provide joist hangers at floor joists 4’ or more at basement mech sump pump area -provide joist hanger at joist to header connection above furnace - The fire rated wall separating townhouses shall be continuous from foundation to the underside of roof sheathing, fire rating shall extend the full length of wall or assembly, IRC R302.2.3 NO INSPECTION PERFORMED ON UNITS 3711, 3713, 3715
Rated Assembly Inspection Failed 5/26/2022 5/26/2022 05/26/2022
Misc
Corrective Action Required
05/24/2022
UNIT 3717: - The fire rated wall separating townhouses shall be continuous from foundation to the underside of roof sheathing, fire rating shall extend the full length of wall or assembly, IRC R302.2.3 NO INSPECTION PERFORMED ON UNITS 3711, 3713, 3715
Erosion Control Inspection Residential Partial 05/26/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
05/26/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
All Rough Inspection - Residential Not Ready 5/27/2022 5/27/2022 05/27/2022
Misc
Corrective Action Required
05/26/2022
5/26/22 NOT READY UNIT 3717: -Fireblock HVAC at garage entry closet -provide solid blocking between studs at party rated wall 7.5’ per engineer letter -seal top and bottom plate penetrations at great room -nail joist hangers at foyer -seal top plate penetrations for DWV, 2nd floor hall -seal unused top plate bore 2nd floor bedroom -nail off corner strap 2nd floor bedroom exterior wall -provide joist hangers at floor joists 4’ or more at basement mech sump pump area -provide joist hanger at joist to header connection above furnace - The fire rated wall separating townhouses shall be continuous from foundation to the underside of roof sheathing, fire rating shall extend the full length of wall or assembly, IRC R302.2.3 NO INSPECTION PERFORMED ON UNITS 3711, 3713, 3715
Rated Assembly Inspection Failed 5/27/2022 5/27/2022 05/27/2022
Misc
Corrective Action Required
05/26/2022
UNIT 3717: - The fire rated wall separating townhouses shall be continuous from foundation to the underside of roof sheathing, fire rating shall extend the full length of wall or assembly, IRC R302.2.3 NO INSPECTION PERFORMED ON UNITS 3711, 3713, 3715
All Rough Inspection - Residential Failed 6/2/2022 6/2/2022 06/02/2022
Misc
Corrective Action Required
05/27/2022
6/2/22 - INSPECTION DENIED, ENGINEER LETTER REJECTED, SEE EMAIL UNIT 3717: -Fireblock HVAC at garage entry closet -provide solid blocking between studs at party rated wall 7.5’ per engineer letter -seal top and bottom plate penetrations at great room -nail joist hangers at foyer -seal top plate penetrations for DWV, 2nd floor hall -seal unused top plate bore 2nd floor bedroom -nail off corner strap 2nd floor bedroom exterior wall -provide joist hangers at floor joists 4’ or more at basement mech sump pump area -provide joist hanger at joist to header connection above furnace - The fire rated wall separating townhouses shall be continuous from foundation to the underside of roof sheathing, fire rating shall extend the full length of wall or assembly, IRC R302.2.3 NO INSPECTION PERFORMED ON UNITS 3711, 3713, 3715
Rated Assembly Inspection Failed 6/2/2022 6/2/2022 06/02/2022
Misc
Corrective Action Required
05/27/2022
6/2/22 - INSPECTION DENIED, ENGINEER LETTER REJECTED, SEE EMAIL UNIT 3717: - The fire rated wall separating townhouses shall be continuous from foundation to the underside of roof sheathing, fire rating shall extend the full length of wall or assembly, IRC R302.2.3 NO INSPECTION PERFORMED ON UNITS 3711, 3713, 3715
Electrical Service Inspection Failed 6/24/2022 6/24/2022 06/24/2022
Misc
Corrective Action Required
05/24/2022
UNIT 3717,3715 OK SERVICE NOT YET INSPECTED
Gas Service Inspection - Residential Failed 6/24/2022 6/24/2022 06/24/2022
Misc
Corrective Action Required
05/24/2022
UNIT 3717 : PRESSURE 3 PSI, MUST MAINTAIN 10 PSI UNIT 3715: BOND GAS LINE, PRESSURE OK
Rated Assembly Inspection Failed 6/24/2022 6/24/2022 06/24/2022
Misc
Corrective Action Required
06/02/2022
UNIT 3717: - The fire rated wall separating townhouses shall be continuous from foundation to the underside of roof sheathing, fire rating shall extend the full length of wall or assembly, IRC R302.2.3 (remove lap siding at exterior to see rated osb) UNIT 3715: -Firecaulk SE cable penetration firewall
All Rough Inspection - Residential Failed 6/24/2022 6/24/2022 06/24/2022
Misc
Corrective Action Required
06/02/2022
UNIT 3717: - The fire rated wall separating townhouses shall be continuous from foundation to the underside of roof sheathing, fire rating shall extend the full length of wall or assembly, IRC R302.2.3 (remove lap siding at exterior to see rated osb) UNIT 3715: -Missing double 2x10 above garage -seal penetration into furr down in garage -missing lib bracing in garage -uncover covered front porch for inspection of framing -address holes drilled closer than 2” in joists above foyer -missing nails in hangers above foyer -cspf nailing to plans and code -address gb bracing at time of sheet rock -furr out for sump line -fire block in furr down see stairs/Rec room -address holes in floor joist drilled closer than 2” to the bottom of joist see basement hallway -complete basement bath vent -support gas line in basement to code -address over board joist under -Firecaulk SE cable penetration firewall -Bath exhaust fan duct to exterior basement bath -fur out sump pump discharge basement den -joist hanger at joist to header basement mech NO INSPECTION PERFORMED ON UNITS 3711, 3713
Electrical Service Inspection Failed 7/1/2022 7/1/2022 07/01/2022
Misc
Corrective Action Required
06/24/2022
UNIT 3717,3715 OK SERVICE NOT YET INSPECTED
Gas Service Inspection - Residential Failed 7/1/2022 7/1/2022 07/01/2022
Misc
Corrective Action Required
06/24/2022
UNIT 3717 : PRESSURE 3 PSI, MUST MAINTAIN 10 PSI UNIT 3715: BOND GAS LINE, PRESSURE OK
Rated Assembly Inspection Failed 7/1/2022 7/1/2022 07/01/2022
Misc
Corrective Action Required
06/24/2022
UNIT 3717: - The fire rated wall separating townhouses shall be continuous from foundation to the underside of roof sheathing, fire rating shall extend the full length of wall or assembly, IRC R302.2.3 (remove lap siding at exterior to see rated osb) UNIT 3715 OK
All Rough Inspection - Residential Failed 7/1/2022 7/1/2022 07/01/2022
Misc
Corrective Action Required
06/24/2022
UNIT 3717: - The fire rated wall separating townhouses shall be continuous from foundation to the underside of roof sheathing, fire rating shall extend the full length of wall or assembly, IRC R302.2.3 (remove lap siding at exterior to see rated osb, confirm design per engineer detail) UNIT 3715: -Missing double 2x10 above garage -address holes drilled closer than 2” in joists above foyer (SUBMIT ENGINEER LETTER FOR N FIELD FIX WITH STRAPS) -address holes in floor joist drilled closer than 2” to the bottom of joist see basement hallway (SUBMIT ENGINEER LETTER ON FIELD FIX) -Bath exhaust fan duct to exterior basement bath NO INSPECTION PERFORMED ON UNITS 3711, 3713 NO CITY STAMPED PLANS ON SITE AT TIME OF INSEPCTION
Gas Service Inspection - Residential Passed 7/6/2022 7/6/2022 07/06/2022
Misc
Resolved
07/06/2022
Electrical Service Inspection Failed 7/6/2022 7/6/2022 07/06/2022
Misc
Corrective Action Required
07/01/2022
-UFER GEC LAND AT NEUTRAL BAR SERVICE -LABEL METERS/DISCONNECTS WITH ADDRESS
Rated Assembly Inspection Passed 7/6/2022 7/6/2022 07/06/2022
Misc
Resolved
07/06/2022
UNIT 3717, 3711 - The fire rated wall separating townhouses shall be continuous from foundation to the underside of roof sheathing, fire rating shall extend the full length of wall or assembly, IRC R302.2.3 (remove lap siding at exterior to see rated osb)
All Rough Inspection - Residential Failed 7/6/2022 7/6/2022 07/06/2022
Misc
Corrective Action Required
07/01/2022
-NAIL EXTERIOR SHEATHING CS-PF AT REAR ALL UNITS PER PLANS UNIT 3717: OK UNIT 3715: -address holes drilled closer than 2” in joists above foyer (SUBMIT ENGINEER LETTER FOR FIELD FIX WITH STRAPS) -address holes in floor joist drilled closer than 2” to the bottom of joist see basement hallway (SUBMIT ENGINEER LETTER ON FIELD FIX) UNIT 3713: -tighten x bracing straps, (2) nails each stud and plate -LIB x bracing at foyer per plans -LIB x bracing at 2nd floor per plans -min 16” oc stud spacing at walls with LIB bracing, see laundry -attic access per code 2nd floor -protect all NM within 6’ of attic entry -solid block all sheathing breaks -move outlets out from behind fur out at basement den -complete bath exhaust fan duct basement bath -fireblock vertical to horizontal at furred down soffit ends basement -seal all top plate penetrations at basement bedroom -provide joist hangers at joist basement stairs foyer, joists must bear 1 1/2” on wood -(3) 2x10 at basement stairs per plans -complete sump pump discharge line at fir out basement den UNIT 3711: -dbl top plate requires min 24” offset between breaks - see garage -dbl 2x10 joists at garage per plans -provide engineer letter on field fix with straps for joists bored less than 2” apart at foyer -(2) nails each stud/plate LIB x bracing straps -tighten LIB x bracing straps -solid block all sheathing breaks -attic access per code at 2nd floor -protect all NM within 6’ of attic entry -anchor bolts within 12” of plate breaks at basement -fireblock vertical to horizontal at furred down soffit ends basement
Driveway Inspection Failed 7/7/2022 7/7/2022 07/07/2022
Misc
Corrective Action Required
07/07/2022
On 7.7.2022 there was no driveway approach sub-grade to be inspected.
Electrical Service Inspection Failed 7/18/2022 7/18/2022 07/18/2022
Misc
Corrective Action Required
07/06/2022
-UFER GEC LAND AT NEUTRAL BAR SERVICE -LABEL METERS/DISCONNECTS WITH ADDRESS
All Rough Inspection - Residential Failed 7/18/2022 7/18/2022 07/18/2022
Misc
Corrective Action Required
07/06/2022
-NAIL EXTERIOR SHEATHING CS-PF AT REAR ALL UNITS PER PLANS UNIT 3717: OK TO INSULATE AND ROCK UNIT 3715:OK TO INSULATE AND ROCK UNIT 3713: -min 16” oc stud spacing at walls with LIB bracing, see laundry -protect all NM within 6’ of attic entry -move outlets out from behind fur out at basement den -complete bath exhaust fan duct basement bath -fireblock vertical to horizontal at furred down soffit ends basement -seal all top plate penetrations at basement bedroom -(3) 2x10 at basement stairs per plans UNIT 3711: OK TO INSULATE AND ROCK, SCREW PATTERN INSPECTION REQUIRED FOR GB BRACING LOCATIONS BEFORE MUD AND TAPE
All Rough Inspection - Residential Failed 7/19/2022 7/19/2022 07/19/2022
Misc
Corrective Action Required
07/18/2022
-NAIL EXTERIOR SHEATHING CS-PF AT REAR ALL UNITS PER PLANS UNIT 3717: OK TO INSULATE AND ROCK (GB SCREW PATTERN APPROVED 7/18/22) UNIT 3715:OK TO INSULATE AND ROCK (GB SCREW PATTERN APPROVED 7/18/22) UNIT 3713: -min 16” oc stud spacing at walls with LIB bracing, see laundry -protect all NM within 6’ of attic entry -move outlets out from behind fur out at basement den -complete bath exhaust fan duct basement bath -fireblock vertical to horizontal at furred down soffit ends basement -seal all top plate penetrations at basement bedroom -(3) 2x10 at basement stairs per plans UNIT 3711: OK TO INSULATE AND ROCK, SCREW PATTERN INSPECTION REQUIRED FOR GB BRACING LOCATIONS BEFORE MUD AND TAPE
Electrical Service Inspection Passed 7/27/2022 7/27/2022 07/27/2022
Misc
Resolved
07/27/2022
-UFER GEC LAND AT NEUTRAL BAR SERVICE -LABEL METERS/DISCONNECTS WITH ADDRESS
All Rough Inspection - Residential Failed 7/27/2022 7/27/2022 07/27/2022
Misc
Corrective Action Required
07/19/2022
-NAIL EXTERIOR SHEATHING CS-PF AT REAR ALL UNITS PER PLANS (NOT DONE, SEE PLANS/ IRC R602.10.6.4 FOR DETAIL AND NAILING PATTERN) UNIT 3717: OK TO INSULATE AND ROCK (GB SCREW PATTERN APPROVED 7/18/22) UNIT 3715:OK TO INSULATE AND ROCK (GB SCREW PATTERN APPROVED 7/18/22) UNIT 3713:OK TO INSULATE AND ROCK, SCREW PATTERN INSPECTION REQUIRED FOR GB BRACING LOCATIONS BEFORE MUD AND TAPE UNIT 3711: OK TO INSULATE AND ROCK, SCREW PATTERN INSPECTION REQUIRED FOR GB BRACING LOCATIONS BEFORE MUD AND TAPE
All Rough Inspection - Residential Failed 7/28/2022 7/28/2022 07/28/2022
Misc
Corrective Action Required
07/27/2022
-NAIL EXTERIOR SHEATHING CS-PF AT REAR ALL UNITS PER PLANS (NOT DONE, SEE PLANS/ IRC R602.10.6.4 FOR DETAIL AND NAILING PATTERN) UNIT 3717: OK TO INSULATE AND ROCK (GB SCREW PATTERN APPROVED 7/18/22) UNIT 3715:OK TO INSULATE AND ROCK (GB SCREW PATTERN APPROVED 7/18/22) UNIT 3713:OK TO INSULATE AND ROCK, SCREW PATTERN INSPECTION REQUIRED FOR GB BRACING LOCATIONS BEFORE MUD AND TAPE UNIT 3711: OK TO INSULATE AND ROCK (GB SCREW PATTERN APPROVED 7/28/22)
All Rough Inspection - Residential Failed 8/1/2022 8/1/2022 08/01/2022
Misc
Corrective Action Required
07/28/2022
-NAIL EXTERIOR SHEATHING CS-PF AT REAR ALL UNITS PER PLANS (NOT DONE, SEE PLANS/ IRC R602.10.6.4 FOR DETAIL AND NAILING PATTERN) UNIT 3717: OK TO INSULATE AND ROCK (GB SCREW PATTERN APPROVED 7/18/22) UNIT 3715:OK TO INSULATE AND ROCK (GB SCREW PATTERN APPROVED 7/18/22) UNIT 3713:OK TO INSULATE AND ROCK (GB SCREW PATTERN APPROVED 8/1/22) UNIT 3711: OK TO INSULATE AND ROCK (GB SCREW PATTERN APPROVED 7/28/22)
Driveway Inspection Partial 8/1/2022 8/1/2022 08/01/2022
Misc
Corrective Action Required
07/07/2022
On 7.7.2022 there was no driveway to be inspected 8.1.2022 I performed a driveway inspection for all 4 units and passed the sub-grade to pour concrete.
Sidewalk Inspection Partial 7/7/2022 7/7/2022 08/01/2022
Misc
Corrective Action Required
07/07/2022
On 7.7.2022 there is no sidewalk sub-grade to be inspected. 8.1.2022 I performed a sidewalk inspection for all four units and pass the sub-grade to pour concrete.
Driveway Inspection Passed 08/04/2022
Misc
Corrective Action Required
08/01/2022
On 7.7.2022 there was no driveway to be inspected 8.1.2022 I performed a driveway inspection for all 4 units and passed the sub-grade to pour concrete. 8.4.2022 Driveway appears to be in compliance
Sidewalk Inspection Passed 8/1/2022 8/1/2022 08/04/2022
Misc
Corrective Action Required
07/07/2022
On 7.7.2022 there is no sidewalk sub-grade to be inspected 8.1.2022 I performed a sidewalk inspection and pass the subgrade to pour concrete 8.4.2022 The sidewalk appears to be in compliance
All Rough Inspection - Residential Passed 8/18/2022 8/18/2022 08/18/2022
Misc
Resolved
08/18/2022
Piers/Caissons Inspection - Residential Partial 8/29/2022 (1:45) 8/29/2022 08/29/2022
Misc
Corrective Action Required
08/29/2022
UNIT 3717 OK
Piers/Caissons Inspection - Residential Partial 9/1/2022 (10:30) 9/1/2022 09/01/2022
Misc
Corrective Action Required
08/29/2022
UNIT 3717, 3711 OK
Piers/Caissons Inspection - Residential Passed 9/2/2022 9/2/2022 09/02/2022
Misc
Corrective Action Required
09/01/2022
UNIT 3717, 3711 OK
Water Service Inspection - R Passed 9/9/2022 (1:30) 9/9/2022 09/09/2022
Misc
Informational
09/09/2022
**WATER SERVICE PASSED 5/24/22**
Occupancy Inspection - Codes Residential Failed 9/12/2022 9/12/2022 09/12/2022
Misc
Corrective Action Required
09/12/2022
-maintain erosion control -resolve outstanding inspection fees -final grade and sod -splash blocks -Sump pump discharge 36” from foundation UNIT 3717: -hammer arrestor for dishwasher -provide code required access for sump pump at crawl space, shield light fixture at crawl space -check GFCI fixture at rear beneath deck, no power at outlet -flood light at rear yard required, ORD 7-1409.2
Occupancy Inspection - Codes Residential Ready for Temp CO 9/13/2022 9/13/2022 09/13/2022
Misc
Corrective Action Required
09/12/2022
-maintain erosion control -final grade and sod -splash blocks -Sump pump discharge 36” from foundation UNIT 3717: OK FOR TCO NO INSPECTION PERFORMED ON UNITS 3711, 3713, 3715
Occupancy Inspection - Codes Residential Temporary C of O 09/13/2022
Misc
Corrective Action Required
09/13/2022
-maintain erosion control -final grade and sod -splash blocks -Sump pump discharge 36” from foundation UNIT 3717: OK FOR TCO NO INSPECTION PERFORMED ON UNITS 3711, 3713, 3715
Occupancy Inspection - Codes Residential Failed 9/14/2022 9/14/2022 09/14/2022
Misc
Corrective Action Required
09/13/2022
-maintain erosion control -final grade and sod -splash blocks -Sump pump discharge 36” from foundation -provide (2) 1/2” through bolts each post/beam connection at deck UNIT 3717: OK FOR TCO UNIT 3715: -provide cover plates all outlets -GFCI protection kitchen counter outlet next to fridge NO INSPECTION PERFORMED ON UNITS 3711, 3713
Occupancy Inspection - Codes Residential Failed 9/15/2022 9/15/2022 09/15/2022
Misc
Corrective Action Required
09/14/2022
-maintain erosion control -final grade and sod -splash blocks -Sump pump discharge 36” from foundation -provide (2) 1/2” through bolts each post/beam connection at deck UNIT 3717: OK FOR TCO UNIT 3715: OK FOR TCO UNIT 3713: -open junction box at front entry -provide stairs at garage -open junction box in basement -provide access for clean out under stairs NO INSPECTION PERFORMED ON UNITS 3711
Occupancy Inspection - Codes Residential Failed 9/16/2022 9/16/2022 09/16/2022
Misc
Corrective Action Required
09/15/2022
-maintain erosion control -final grade and sod -splash blocks -Sump pump discharge 36” from foundation -provide (2) 1/2” through bolts each post/beam connection at deck UNIT 3717: OK FOR TCO UNIT 3715: OK FOR TCO UNIT 3713: OK FOR TCO NO INSPECTION PERFORMED ON UNITS 3711
Occupancy Inspection - Codes Residential Failed 9/19/2022 9/19/2022 09/19/2022
Misc
Corrective Action Required
09/16/2022
-maintain erosion control -final grade and sod -splash blocks -Sump pump discharge 36” from foundation -provide (2) 1/2” through bolts each post/beam connection at deck UNIT 3717: OK FOR TCO UNIT 3715: OK FOR TCO UNIT 3713: OK FOR TCO UNIT 3711: -complete stairs garage -garage door self closing -provide hammer arrestor dishwasher kitchen -provide access for sump pump/clean out under basement stairs
Occupancy Inspection - Codes Residential Failed 9/20/2022 9/20/2022 09/20/2022
Misc
Corrective Action Required
09/19/2022
-splash blocks -Sump pump discharge 36” from foundation -Uncover manhole covers MH 7-2 and MH 7-1 at front of lot as shown on plot plan UNIT 3717: OK FOR TCO UNIT 3715: OK FOR TCO UNIT 3713: OK FOR TCO UNIT 3711: OK FOR TCO
Occupancy Inspection - Codes Residential Not Ready 9/21/2022 9/21/2022 09/21/2022
Misc
Corrective Action Required
09/20/2022
-splash blocks -Sump pump discharge 36” from foundation -Uncover manhole covers MH 7-2 and MH 7-1 at front of lot as shown on plot plan -Pay inspection fee UNIT 3717: OK FOR TCO UNIT 3715: OK FOR TCO UNIT 3713: OK FOR TCO UNIT 3711: OK FOR TCO
Erosion Control Inspection Residential Passed 10/6/2022 10/6/2022 10/06/2022
Occupancy Inspection - Codes Residential Failed 10/6/2022 10/6/2022 10/06/2022
Misc
Corrective Action Required
09/21/2022
-raise manhole MH7-2 at front of lot to grade UNIT 3717: OK FOR TCO UNIT 3715: OK FOR TCO UNIT 3713: OK FOR TCO UNIT 3711: OK FOR TCO
Plot Plan Inspection Failed 10/6/2022 10/6/2022 10/06/2022
Misc
Corrective Action Required
10/06/2022
-raise manhole MH7-2 at front of lot to grade
Occupancy Inspection - Codes Residential Ready for Temp CO 10/11/2022 10/11/2022 10/11/2022
Misc
Corrective Action Required
10/06/2022
-raise manhole MH7-2 at front of lot to grade UNIT 3717: OK FOR TCO UNIT 3715: OK FOR TCO UNIT 3713: OK FOR TCO UNIT 3711: OK FOR TCO 10/10/22 - EXTENSION REQUEST RECEIVED/APPROVED
Plot Plan Inspection Passed 10/17/2022 10/17/2022 10/17/2022
Misc
Resolved
10/17/2022
-raise manhole MH7-2 at front of lot to grade
Occupancy Inspection - Codes Residential Full C of O 10/17/2022 10/17/2022 10/17/2022
Misc
Resolved
10/17/2022
-raise manhole MH7-2 at front of lot to grade UNIT 3717: OK FOR TCO UNIT 3715: OK FOR TCO UNIT 3713: OK FOR TCO UNIT 3711: OK FOR TCO 10/10/22 - EXTENSION REQUEST RECEIVED/APPROVED
Documents & Images
Date Uploaded File Type Document Name
09/28/2021 LOT 11 FINAL 9-3-21
09/28/2021 Application Form OS #11 - PERMIT APP
09/28/2021 Lot 11 OS
09/28/2021 OS #11 - Emerald Townhome - Sheets - Signed
09/28/2021 Approved Plans APPROVED TRUSS LAYOUT
09/28/2021 Approved Plans APPROVED TRUSS PACKAGE
09/28/2021 Approved Plans APPROVED TRUSS LAYOUT
09/28/2021 Approved Plans APPROVED TRUSS PACKAGE
09/29/2021 OS #11 - Emerald Townhome - Sheets - Signed Unlocked for City Review
09/29/2021 Permit Codes Residential Plan Review
10/05/2021 LOT 11 CITY
10/05/2021 Plot Plan APPROVED PLOT PLAN
10/05/2021 Engineer Report/Study ENGINEER REPORT
10/05/2021 Permit Codes Residential Plan Review
10/05/2021 Permit DS Building Permit
10/05/2021 Receipt Receipt for transaction:2021-007794
11/23/2021 3711, 3713, 3715, & 3717 SW Maryvill Pl LSMO 4 Plex Footing Inspection Report 11-18-21
11/29/2021 Letter INSPECTION SUMMARY
12/22/2021 Letter INSPECTION SUMMARY
01/27/2022 Approved Plans APPROVED PLANS
05/02/2022 11 osage letter #2- signed
05/09/2022 Letter INSPECTION SUMMARY
05/10/2022 Letter INSPECTION SUMMARY
05/10/2022 Letter INSPECTION SUMMARY
05/12/2022 Letter INSPECTION SUMMARY
05/12/2022 Letter INSPECTION SUMMARY
05/16/2022 11 osage letter #3
05/24/2022 Letter INSPECTION SUMMARY
05/24/2022 Letter INSPECTION SUMMARY
05/24/2022 Letter INSPECTION SUMMARY
05/24/2022 Letter INSPECTION SUMMARY
05/24/2022 Letter INSPECTION SUMMARY
05/26/2022 Letter INSPECTION SUMMARY
05/26/2022 Letter INSPECTION SUMMARY
05/26/2022 Letter INSPECTION SUMMARY
05/27/2022 Letter INSPECTION SUMMARY
05/27/2022 Letter INSPECTION SUMMARY
06/01/2022 11 osage letter #4
06/02/2022 Letter INSPECTION SUMMARY
06/02/2022 Letter INSPECTION SUMMARY
06/23/2022 Emerald Townhome - FIRE WALL UPDATE 6_15_22
06/24/2022 Letter INSPECTION SUMMARY
06/24/2022 Letter INSPECTION SUMMARY
06/24/2022 Letter INSPECTION SUMMARY
06/24/2022 Letter INSPECTION SUMMARY
07/01/2022 Letter INSPECTION SUMMARY
07/01/2022 Letter INSPECTION SUMMARY
07/01/2022 Letter INSPECTION SUMMARY
07/01/2022 Letter INSPECTION SUMMARY
07/06/2022 Letter INSPECTION SUMMARY
07/06/2022 Letter INSPECTION SUMMARY
07/06/2022 Letter INSPECTION SUMMARY
07/06/2022 Letter INSPECTION SUMMARY
07/06/2022 Email RE_ Osage 11 - Flameblock Data Sheet
07/07/2022 11 osage letter #5
07/18/2022 Letter INSPECTION SUMMARY
07/18/2022 Letter INSPECTION SUMMARY
07/19/2022 Letter INSPECTION SUMMARY
07/21/2022 Letter INSPECTION SUMMARY
07/21/2022 Letter INSPECTION SUMMARY
07/21/2022 Letter INSPECTION SUMMARY
07/27/2022 Letter INSPECTION SUMMARY
07/27/2022 Letter INSPECTION SUMMARY
07/28/2022 Letter INSPECTION SUMMARY
08/01/2022 Letter INSPECTION SUMMARY
08/02/2022 Letter INSPECTION SUMMARY
08/02/2022 Letter INSPECTION SUMMARY
08/02/2022 Letter INSPECTION SUMMARY
08/02/2022 Letter INSPECTION SUMMARY
08/02/2022 Letter INSPECTION SUMMARY
08/02/2022 Letter INSPECTION SUMMARY
08/02/2022 Letter INSPECTION SUMMARY
08/18/2022 Letter INSPECTION SUMMARY
08/29/2022 Letter INSPECTION SUMMARY
09/01/2022 Letter INSPECTION SUMMARY
09/02/2022 Letter INSPECTION SUMMARY
09/02/2022 Letter INSPECTION SUMMARY
09/02/2022 Letter INSPECTION SUMMARY
09/09/2022 Letter INSPECTION SUMMARY
09/12/2022 Letter INSPECTION SUMMARY
09/12/2022 Receipt Receipt for transaction:2022-007459
09/13/2022 Receipt Receipt for transaction:2022-007489
09/13/2022 Letter Codes Temporary Certificate of Occupancy
09/14/2022 Letter INSPECTION SUMMARY
09/15/2022 Letter INSPECTION SUMMARY
09/16/2022 Letter INSPECTION SUMMARY
09/19/2022 Letter INSPECTION SUMMARY
09/20/2022 Letter INSPECTION SUMMARY
09/21/2022 Letter INSPECTION SUMMARY
10/05/2022 Receipt Receipt for transaction:2022-008048
10/06/2022 Letter INSPECTION SUMMARY
10/06/2022 Letter INSPECTION SUMMARY
10/06/2022 Letter INSPECTION SUMMARY
10/10/2022 Extension Request Form
10/11/2022 Certificate/License Codes Temporary Certificate of Occupancy
10/11/2022 Receipt Receipt for transaction:2022-008162
10/17/2022 Letter INSPECTION SUMMARY
10/17/2022 Letter Field Certificate of Occupancy
10/17/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home