Planning Application Status

PL2024136




 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PL2024136
Village at Discovery Park, Lot 5-8
Commercial Final Development Plan
Commercial Final Development Plan
Approved
05/23/2024
Two Mixed Use Buildings, Animal Hospital, Animal Daycare
Locations
Contacts
Brian Maenner - Intrinsic Development, Address:3622 Endeavor Ave., Ste. 101, Phone:(573) 881-0280  
Nolan Dixon, Address:1000 W. Nifong Blvd., Phone:(573) 447-0292  
Matthew Braden, Address:1000 W. Nifong Blvd., Phone:(573) 447-0292  
Reviews
Review Type Outcome Est. Completion Date Completed
Planning Review No Comments 04/10/2025 04/09/2025
Hector Soto Jr.
Engineering Review No Comments 04/10/2025 04/07/2025
Sue Pyles, P.E.
Engineering Review No Comments 02/20/2025 02/24/2025
Sue Pyles, P.E.
DE C&O #07 Easements
Corrective Action Required
02/06/2025

All permanent off-site easements, in a form acceptable to the City, shall be executed and recorded with the Jackson County Recorder of Deeds prior to the issuance of a Certificate of Substantial Completion or approval of the final plat. A certified copy shall be submitted to the City for verification.
DE Contact Field Eng. Inspector
Corrective Action Required
02/06/2025

Prior to the commencement of any construction activities, the Contractor shall contact Field Engineering Inspections at (816) 969-1200 to coordinate a preconstruction meeting / conference with the assigned Field Engineering Inspector.
DE Engineers Estimate
Corrective Action Required
02/06/2025

The Engineer’s Estimate of Probable Construction Costs has been accepted for this project, and the Engineering Plan Review and Inspection Fee (which is calculated as 3% of the total infrastructure cost plus a water test inspection fee(s)), and the water tap and meter setup fee have been included. These must be paid prior to the issuance of an infrastructure permit and/or the final processing of a building permit. $304,357.55
Revisions to approved plans submitted by applicant, Sue only discipline needing to review
Engineering Review Approved with Conditions 09/10/2024 09/10/2024
Sue Pyles, P.E.
DE C&O #07 Easements
Corrective Action Required
09/10/2024

All permanent off-site easements, in a form acceptable to the City, shall be executed and recorded with the Jackson County Recorder of Deeds prior to the issuance of a Certificate of Substantial Completion or approval of the final plat. A certified copy shall be submitted to the City for verification.
DE Contact Field Eng. Inspector
Corrective Action Required
09/10/2024

Prior to the commencement of any construction activities, the Contractor shall contact Field Engineering Inspections at (816) 969-1200 to coordinate a preconstruction meeting / conference with the assigned Field Engineering Inspector.
DE Engineers Estimate
Corrective Action Required
09/10/2024

The Engineer’s Estimate of Probable Construction Costs has been accepted for this project, and the Engineering Plan Review and Inspection Fee (which is calculated as 3% of the total infrastructure cost plus a water test inspection fee(s)), and the water tap and meter setup fee have been included. These must be paid prior to the issuance of an infrastructure permit and/or the final processing of a building permit. $304,357.55
Engineering Review Corrections 08/09/2024 08/12/2024
Sue Pyles, P.E.
Miscellaneous Correction
Resolved
08/09/2024

Sheets CE6.1 & CE6.2: • What does the cross-hatching represent? Please clarify. • Please label flowline elevations of all pipe separations that are 2 feet or less. • Include the following note on any profile sheet applicable: “Compacted Fill shall be placed to a minimum 18” above the top of the pipe prior to installation.” Show and label the limits of the compacted fill placement in the Profile view. Use hatching for clarity. • Please review drops across structures and verify that they all meet the City’s requirements shown in the Design and Construction Manual Section 5604.5. • A pipe crossing appears to be missing on Line 1 (downstream of Structure 1F) and Line 7. Please include. 8/1: It appears that the drops thru the following structures do noy meet City requirements, please evaluate and revise as necessary: 1B, 1C, 2B, 2C, 4A, 6B.
Corrective Action Required
08/09/2024

Please review the submitted estimate quantities. In spot checking the storm sewer quantities, I was coming up with different pipe quantities as well as different quantities on a few of the structures. I didn't check any beyond those, so please review the all items and revise as needed. Please include storm sewer connection to existing structures and structure conversions, and sanitary sewer wyes to the estimate.
Corrective Action Required
08/09/2024

Please submit the entire sanitary easement document, which includes the exhibit, for review. The private water line is shown parallel to the sanitary sewer within the sanitary easement. The private water line is not allowed to be within the limits of the sanitary easement. Please revise accordingly.
Engineering Review Corrections 07/31/2024 08/01/2024
Sue Pyles, P.E.
Miscellaneous Correction
Resolved
08/02/2024

General: The curb and gutter detail or pavement detail must show that the aggregate base and compaction of native subgrade extends a minimum of one (1) foot beyond the back of curb.
Miscellaneous Correction
Resolved
08/02/2024

Sheet CE2.1: Please include a legend for the different shading, if not labeled, on this sheet and throughout the plan set.
Miscellaneous Correction
Resolved
08/02/2024

Sheet CE3.0: Existing contours are missing from the SW corner.
Miscellaneous Correction
Resolved
08/02/2024

Sheets CE4.1 & CE4.2: Please include water meter sizes and pipe sizes. Additional vault comments may be forthcoming based on sizes provided.
Miscellaneous Correction
Resolved
08/02/2024

Sheet CE5.1: • What does the cross-hatching represent? Please clarify. • Please label flowline elevations of all pipe separations that are 2 feet or less.
Miscellaneous Correction
Partial Correction
08/01/2024

Sheets CE6.1 & CE6.2: • What does the cross-hatching represent? Please clarify. • Please label flowline elevations of all pipe separations that are 2 feet or less. • Include the following note on any profile sheet applicable: “Compacted Fill shall be placed to a minimum 18” above the top of the pipe prior to installation.” Show and label the limits of the compacted fill placement in the Profile view. Use hatching for clarity. • Please review drops across structures and verify that they all meet the City’s requirements shown in the Design and Construction Manual Section 5604.5. • A pipe crossing appears to be missing on Line 1 (downstream of Structure 1F) and Line 7. Please include. 8/1: It appears that the drops thru the following structures do noy meet City requirements, please evaluate and revise as necessary: 1B, 1C, 2B, 2C, 4A, 6B.
Traffic Review No Comments 07/31/2024 07/31/2024
Erin Ralovo
Fire Review Approved with Conditions 07/31/2024 07/31/2024
Jim Eden
Code Statement
Partial Correction
08/02/2024

All issues pertaining to life safety and property protection from the hazards of fire, explosion or dangerous conditions in new and existing buildings, structures and premises, and to the safety to fire fighters and emergency responders during emergency operations, shall be in accordance with the 2018 International Fire Code.
Hydrants
Resolved
07/31/2024

IFC 507.5.1 - Where a portion of the facility or building hereafter constructed or moved into or within the jurisdiction is more than 300 feet from a hydrant on a fire apparatus access road, as measured by an approved route around the exterior of the facility or building, on-site fire hydrants and mains shall be provided where required by the fire code official. The 300' distance is exceeded on Buildings 5, 7 and 8.
Miscellaneous Correction
Resolved
07/31/2024

D105.3 Proximity to building. One or more of the required access routes meeting this condition shall be located not less than 15 feet (4572 mm) and not greater than 30 feet (9144 mm) from the building, and shall be positioned parallel to one entire side of the building. The side of the building on which the aerial fire apparatus access road is positioned shall be approved by the fire code official. How will this be met on Building 5? How will this be met
FDC
Resolved
07/31/2024

IFC 903.3.7 - Fire department connections. The location of fire department connections shall be approved by the fire code official. Connections shall be a 4 inch Storz type fitting and located within 100 feet of a fire hydrant, or as approved by the code official. Building 5 does not have a hydrant within 100 feet of the FDC.
Planning Review Approved with Conditions 07/31/2024 07/31/2024
Hector Soto Jr.
Corrective Action Required
07/31/2024

MECHANICAL SCREENING. Building perspectives and elevations have been provided and appear to show that building parapet wall heights are sufficient to fully screen all RTUs from view on all sides. Confirmation of adequate screening shall be done at the time of occupancy inspection. Should it be found at that time that adequate screening via the parapet wall heights is not achieved, screening of any visible RTUs shall be required using a metal screen system. This comment is only informational and requires no further action at this time.
Building Codes Review No Comments 07/31/2024 07/30/2024
Joe Frogge
Miscellaneous Correction
Resolved
07/30/2024

Inadeqquate information to complete review. Provide the following: - Specify type of connection at mains (corps provided by LSW) - Specify all water pipe sizes - Specify type of water piping. - Specify type and size of meters.
Engineering Review Corrections 06/11/2024 06/12/2024
Sue Pyles, P.E.
Miscellaneous Correction
Corrective Action Required
06/12/2024

General: The curb and gutter detail or pavement detail must show that the aggregate base and compaction of native subgrade extends a minimum of one (1) foot beyond the back of curb.
Miscellaneous Correction
Corrective Action Required
06/12/2024

Sheet CE2.1: Please include a legend for the different shading, if not labeled, on this sheet and throughout the plan set.
Miscellaneous Correction
Corrective Action Required
06/12/2024

Sheet CE3.0: Existing contours are missing from the SW corner.
Miscellaneous Correction
Corrective Action Required
06/12/2024

Sheets CE4.1 & CE4.2: Please include water meter sizes and pipe sizes. Additional vault comments may be forthcoming based on sizes provided.
Miscellaneous Correction
Corrective Action Required
06/12/2024

Sheet CE5.1: • What does the cross-hatching represent? Please clarify. • Please label flowline elevations of all pipe separations that are 2 feet or less.
Miscellaneous Correction
Corrective Action Required
06/12/2024

Sheets CE6.1 & CE6.2: • What does the cross-hatching represent? Please clarify. • Please label flowline elevations of all pipe separations that are 2 feet or less. • Include the following note on any profile sheet applicable: “Compacted Fill shall be placed to a minimum 18” above the top of the pipe prior to installation.” Show and label the limits of the compacted fill placement in the Profile view. Use hatching for clarity. • Please review drops across structures and verify that they all meet the City’s requirements shown in the Design and Construction Manual Section 5604.5. • A pipe crossing appears to be missing on Line 1 (downstream of Structure 1F) and Line 7. Please include.
Building Codes Review Corrections 06/11/2024 06/11/2024
Joe Frogge
Miscellaneous Correction
Corrective Action Required
06/11/2024

Inadeqquate information to complete review. Provide the following: - Specify type of connection at mains (corps provided by LSW) - Specify all water pipe sizes - Specify type of water piping. - Specify type and size of meters.
Fire Review Corrections 06/11/2024 06/11/2024
Jim Eden
Code Statement
Informational
07/30/2024

All issues pertaining to life safety and property protection from the hazards of fire, explosion or dangerous conditions in new and existing buildings, structures and premises, and to the safety to fire fighters and emergency responders during emergency operations, shall be in accordance with the 2018 International Fire Code.
Hydrants
Corrective Action Required
06/11/2024

IFC 507.5.1 - Where a portion of the facility or building hereafter constructed or moved into or within the jurisdiction is more than 300 feet from a hydrant on a fire apparatus access road, as measured by an approved route around the exterior of the facility or building, on-site fire hydrants and mains shall be provided where required by the fire code official. The 300' distance is exceeded on Buildings 5, 7 and 8.
Miscellaneous Correction
Corrective Action Required
06/11/2024

D105.3 Proximity to building. One or more of the required access routes meeting this condition shall be located not less than 15 feet (4572 mm) and not greater than 30 feet (9144 mm) from the building, and shall be positioned parallel to one entire side of the building. The side of the building on which the aerial fire apparatus access road is positioned shall be approved by the fire code official. How will this be met on Building 5?
FDC
Corrective Action Required
06/11/2024

IFC 903.3.7 - Fire department connections. The location of fire department connections shall be approved by the fire code official. Connections shall be a 4 inch Storz type fitting and located within 100 feet of a fire hydrant, or as approved by the code official. Building 5 does not have a hydrant within 100 feet of the FDC.
Traffic Review Corrections 06/11/2024 06/10/2024
Erin Ralovo
Corrective Action Required
06/10/2024

The trash enclosure in the center of the development is not advised. This could likely interfere with the main drive access durring pick up times.
Corrective Action Required
06/10/2024

Drive radii do not meet the City's requirements and should be 35 FT. Please provide turning movements for the design vehicle. At a minimum the design vehicle should be a fire truck but it there will be truck deliveries to the retail spaces these vehicles will need to be acommodated.
Planning Review Corrections 06/11/2024 06/10/2024
Hector Soto Jr.
Corrective Action Required
06/10/2024

VICINITY MAP. Correct the directional prefix for Colbern Rd from NW to NE.
Corrective Action Required
06/10/2024

STREETS. 1) Add the NE directional prefix to the Trails Edge Blvd, Alura Way and Discovery Ave street name labels on all sheets showing the street name. 2) Correct the directional prefix for Colbern Rd from NW To NE on all sheets showing the street name. Both of these comments apply to Sheets CE 2.1, CE 4.1, CE 4.2, CE 7.1 and CE 7.2. 3) Label the tract width or half-width that contains the named private streets/drives (i.e. Trails Edge Blvd, Alura Way and Discovery Ave).
Corrective Action Required
06/10/2024

PARKING. The parking calculation provided on Sheet CE 7.2 indicates that parking is being provided at a rate of 1.5 spaces/unit. The UDO requires parking be provided for 1-2 bedroom units at a rate of 2.0 spaces/unit (1.5 spaces/unit + 0.5 spaces/unit for visitors). However, the approved preliminary development plan utilized a ULI shared parking model for the development that would provide parking for the residential component at a rate of 1.17 spaces/unit and 0.15 spaces/unit for visitors at peak demand time. Add a note to the plans regarding the lower parking requirement standard approved with preliminary development plan.
Corrective Action Required
06/10/2024

LIGHTING. The photometric plan and fixture schedule only includes information for the parking lot pole lights. No information is provided for any wall-mounted light fixtures. Include information for the all proposed exterior wall-mounted light fixtures. Said fixtures shall comply with the requirements of UDO Sections 8.220, 8.260 and 8.270.
Corrective Action Required
06/10/2024

BUILDING ELEVATIONS. 1) No building elevations are provided for the dog daycare on Lot 8--only renderings are provided. Scalable and dimensioned architectural building elevations of all sides of the building shall be submitted as part of this application. The building elevations shall have callouts of all exterior building materials and colors. Renderings are helpful artistic representations that convey what a building will look like, but they only serve as a supplement to scalable architectural drawings. 2) Provide a color schedule for the exterior building materials on the animal hospital building elevations.
Corrective Action Required
06/10/2024

MECHANICAL SCREENING. All roof-mounted equipment shall be screened entirely from view on all sides by using parapet walls at the same height as the mechanical units. Dash in the location of all roof-top mechanical units on all building elevations to review for compliance with the screening requirement. Take into account the added height from any curbs on which the RTUs will sit when designing the final parapet wall height. Show the location of any ground-mounted equipment on the site plan. Ground mounted equipment shall be totally screened from view by evergreen landscaping or masonry wall up to a height of the units to be screened.
Corrective Action Required
06/10/2024

EXTERIOR BUILDING MATERIALS. The building elevations provided for the animal hospital include the use of metal wall panels as a primary exterior building material. The City's development ordinance only allows the use of metal in an incidental manner (e.g. trim, canopy, standing seam metal, etc.) unless otherwise approved by the City Council as part of a preliminary development plan (PDP). The PDP for Discovery Park Phase 1 included design guidelines governing materials, which did not include the use of metal as a primary exterior material. The rendering of the subject building in the PDP application showed the use of a masonry or cementitous wall panel material where the metal is now shown. Masonry and cementitous panel are both approved materials. Pursuit of the metal wall panel system as shown on the elevations will require a new PDP application that requires public hearings before both the Planning Commission and City Council. Said process typically takes 3 months from the time of application.
Corrective Action Required
06/10/2024

LANDSCAPE PLAN. The landscape compliance table lists the site's current zoning as CP-2 and proposed zoning as PMIX. The site has already been rezoned to PMIX. Revise to reflect the current PMIX zoning.
Corrective Action Required
06/10/2024

LANDSCAPE ISLAND WIDTH. Tree planting areas within landscape islands shall be no less than 10 feet in width. No tree shall be located less than 4 feet from the back of curb. The north-south oriented "canoe" landscape island located between Lots 5 and 7 does not meet the minimum width requirements for tree planting areas. Similarly, the shorter east-west double "canoe" located between Lots 5 and 6 also doesn't meet the minimum width requirement.
Corrective Action Required
06/10/2024

TRASH ENCLOSURES. 1) Trash enclosure areas shall be improved with a Portland cement concrete pad and a Portland cement concrete approach 30 feet in length, measured from the enclosure opening. The pad and approach shall be improved with a minimum six inches of full depth unreinforced Portland cement concrete constructed on a sub-grade of four inches of granular base course. 2) No details for the proposed trash enclosures have been provided. Provide a detail(s) of the proposed enclosures. Each trash enclosure shall be constructed of masonry walls or steel architecturally designed walls with either a solid steel opaque gate painted to be compatible with the color of the masonry or steel walls and building it is to serve or a steel framed semi-opaque gate with a screen mesh material approved by the Director that provides an appropriate visual barrier.
Corrective Action Required
06/10/2024

PARKING GARAGE. 1) Will any ADA accessible spaces be provided in the Lot 7 parking garage? If so, call out said spaces and adjacent access aisle(s). Also dimension the space(s) and access aisle(s). 2) Dimension the widths of the garage entrance/exits and the interior drive aisle lane.
Corrective Action Required
06/10/2024

FENCE/SCREEN. Provide a detail of the fence/screen proposed to be used for the dog daycare outdoor exercise area for review.
Corrective Action Required
06/10/2024

FAA FORM 7460. A Form 7460 shall be sumitted to the FAA and comments received back and provided to the City prior to the issuance of any building permit.
Fees
Paid Fees Amount Paid Owing Date Paid
9110077-Final Development Plan fee $725.00 $725.00 Paid 08/02/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Hearings
Title Location Date Time
Documents & Images
Date Uploaded File Type Document Name
05/28/2024 Plans FDP Plan Set_Rev 0_PL2024136
05/28/2024 Engineer Report/Study Storm Sewer Narative_Rev 0_PL2024136
05/28/2024 Engineer Report/Study Storm Sewer Calculations_Rev 0_PL2024136
05/28/2024 Engineer Report/Study SWPPP_Rev 0_PL2024136
05/28/2024 Engineers Estimate Engineers Cost Estimate_Rev 0_PL2024136
05/28/2024 Application Form Application_PL2024136
06/12/2024 Letter Applicant Letter_PL2024136
07/23/2024 Letter Response Letter_PL2024136
07/23/2024 Letter Lot 5 FAA Determination_PL2024136
07/23/2024 Letter Lot 6 FAA Determination_PL2024136
07/23/2024 Letter Lot 7 FAA Determination_PL2024136
07/23/2024 Letter Lot 8 FAA Determination_PL2024136
07/23/2024 Letter MDNR_Discovery Park Zone 1-4_PL2024136
07/23/2024 Engineers Estimate Engineer's Cost Estimate_Rev1_PL2024136
07/23/2024 Engineer Report/Study Storm Sewer Calculations_PL2024136
07/23/2024 Plans FDP Plan Set_Rev1_PL2024136
07/24/2024 Drawing Public Sewer Esmt_PL2024136
08/02/2024 Letter Applicant Letter_PL2024136
08/02/2024 Receipt Receipt_PL2024136
08/02/2024 Plans FDP Plan Set_Rev2_PL2024136
08/02/2024 Letter Response Letter_PL2024136
08/12/2024 Letter Applicant Letter_PL2024136
09/03/2024 Letter City comment response letter
09/03/2024 Engineers Estimate Cost Estimate_PL2024136
09/04/2024 Plans FDP Plan Set_Rev3_PL2024136
09/11/2024 Letter Applicant Letter - FDP (DFDP)
09/18/2024 Engineers Estimate Engineering Fees_PL2024136
09/30/2024 Approved Plans Stamped Approved Plans_Rev0_PL2024136_Animal Hospital
09/30/2024 Approved Plans Stamped Approved Plans_Rev0_PL2024136_Pet Spa
01/31/2025 Plans Revised Plan Set_PL2024136
01/31/2025 Letter Approved Plan Revision Letter_PL2024136
02/25/2025 Approved Plans Stamped Approved Plans Lot 5_PL2024136
02/25/2025 Approved Plans Stamped Approved Plans Lot 6_Rev1_PL2024136 (Animal Hospital)
02/25/2025 Approved Plans Stamped Approved Plans Lot 7_PL2024136
02/25/2025 Approved Plans Stamped Approved Plans Lot 8__Rev1_PL2024136 (Pet Spa)
04/03/2025 Plans Revised Plans for Lot 5 Building Shift_PL2024136
04/10/2025 Activity Document Private Sewer Easement_PL2024136
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New license, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home