Permit Application Status

PRRES20241112


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20241112
Building Permit - Residential
Certificate of Occupancy
NEW DUPLEX
NEW HOUSE. UNFINISHED BASEMENT. UNCOVERED DECK. ROOF TRUSSES.
03/11/2024
03/21/2024
09/15/2024
10/16/2024
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee for New Duplex $2,905.65 $2,905.65 Paid 03/21/2024
Water Tap Fee $7,520.00 $7,520.00 Paid 03/21/2024
Water Meter Fee $1,360.92 $1,360.92 Paid 03/21/2024
Sanitary Sewer Development Fee $4,318.00 $4,318.00 Paid 03/21/2024
Right of Way Permit Fee $85.00 $85.00 Paid 03/21/2024
Residential Excise Tax Fee $1,240.32 $1,240.32 Paid 03/21/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 09/24/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 09/24/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 09/24/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 09/24/2024
Water Meter Fee $81.59 $81.59 Paid 09/24/2024
$1,360.92
Temporary Occupancy Fee $50.00 $50.00 Paid 10/16/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 4/1/2024 04/01/2024
Miscellaneous Correction
Informational
04/01/2024
Footing passed by a third party. No mention of piers were in the footing report
Erosion Control Inspection Residential Partial 4/1/2024 04/01/2024
Miscellaneous Correction
Informational
04/01/2024
Erosion control is in place at the time of footing inspection. Full erosion measures must be in place until CofO
Underslab Plumbing Inspection - Residential Failed 4/16/2024 4/16/2024 04/16/2024
Miscellaneous Correction
Corrective Action Required
04/16/2024
Remove all wood forms from foundation
Underslab Plumbing Inspection - Residential Failed 4/17/2024 4/17/2024 04/17/2024
Miscellaneous Correction
Resolved
04/17/2024
Remove all wood forms from foundation
Miscellaneous Correction
Corrective Action Required
04/17/2024
Underslab plumbing Underslab plumbing will not pass until all wood from forms which includes stakes are removed from contact of the ground. R317.1.2 ground contact
Sewer Service Inspection - R Passed 4/17/2024 4/17/2024 04/17/2024
Water Service Inspection - R Passed 4/19/2024 04/19/2024
Underslab Plumbing Inspection - Residential Not Ready 4/22/2024 4/22/2024 04/22/2024
Miscellaneous Correction
Resolved
04/22/2024
Underslab plumbing Underslab plumbing will not pass until all wood from forms which includes stakes are removed from contact of the ground. R317.1.2 ground contact
Miscellaneous Correction
Corrective Action Required
04/22/2024
Underslab plumbing Underslab plumbing will not pass until all wood from forms which includes stakes are removed from contact of the ground. R317.1.2 ground contact No improvements were made from last inspection. 04/22/2024. KBEARD Not ready
Underslab Plumbing Inspection - Residential Passed 4/24/2024 4/24/2024 04/24/2024
Miscellaneous Correction
Resolved
04/24/2024
Underslab plumbing Underslab plumbing will not pass until all wood from forms which includes stakes are removed from contact of the ground. R317.1.2 ground contact No improvements were made from last inspection. 04/22/2024. KBEARD Not ready
Erosion Control Inspection Residential Partial 4/24/2024 04/24/2024
Miscellaneous Correction
Resolved
04/24/2024
Erosion control is in place at the time of footing inspection. Full erosion measures must be in place until CofO
Miscellaneous Correction
Informational
04/24/2024
Erosion control is in place at the time of footing inspection. Full erosion measures must be in place until CofO
All Rough Inspection - Residential Failed 6/14/2024 6/14/2024 06/14/2024
Misc
Informational
06/14/2024
Exterior PFH only OK to cover at both units
Erosion Control Inspection Residential Failed 06/14/2024
Miscellaneous Correction
Informational
04/24/2024
6/14/24 -Maintain erososion control methods at front of lot. -Full erosion measures must be in place until CofO
Erosion Control Inspection Residential Partial 7/11/2024 07/11/2024
Miscellaneous Correction
Resolved
07/11/2024
6/14/24 -Maintain erososion control methods at front of lot. -Full erosion measures must be in place until CofO
Miscellaneous Correction
Informational
07/11/2024
Full erosion control is in place and must be maintained until CofO
All Rough Inspection - Residential Not Ready 7/11/2024 7/11/2024 07/11/2024
Misc
Informational
06/14/2024
Exterior PFH only OK to cover at both units
Miscellaneous Correction
Corrective Action Required
07/11/2024
-Plans not on jobs site -Official city stamped plans must be on site until CofO Not ready for inspection 07/11/2024 KBEARD 9:45am
All Rough Inspection - Residential Not Ready 7/15/2024 7/15/2024 07/15/2024
Misc
Resolved
07/15/2024
Exterior PFH only OK to cover at both units
Miscellaneous Correction
Resolved
07/15/2024
-Plans not on jobs site -Official city stamped plans must be on site until CofO Not ready for inspection 07/11/2024 KBEARD 9:45am
Miscellaneous Correction
Corrective Action Required
07/15/2024
3729 and 3731 SW Knoxville. All rough 3729 Garage 5/8 inch anchor bolts are not located in the middle 1/3 of sole plate and are not tightened down Garage anchor bolts need to be tightened down Nail garage S/W corner to code Fire block holes in top plate in garage Fire block top of chase in garage to powder bathroom Fire block 1 3/4 inch waste line in garage horizontal chase Inspection stopped due to no fire blocking of both units Walk your property before scheduling inspections Both units are not ready for inspection Not a complete list
Electrical Service Inspection Passed 7/17/2024 7/17/2024 07/17/2024
Gas Service Inspection - Residential Failed 7/17/2024 7/17/2024 07/17/2024
Miscellaneous Correction
Corrective Action Required
07/17/2024
Gas in unit 3729 read 0 at the time of inspection Unit 3731 passed
All Rough Inspection - Residential Failed 7/17/2024 7/17/2024 07/17/2024
Miscellaneous Correction
Resolved
07/17/2024
3729 and 3731 SW Knoxville. All rough 3729 Garage 5/8 inch anchor bolts are not located in the middle 1/3 of sole plate and are not tightened down Garage anchor bolts need to be tightened down Nail garage S/W corner to code Fire block holes in top plate in garage Fire block top of chase in garage to powder bathroom Fire block 1 3/4 inch waste line in garage horizontal chase Inspection stopped due to no fire blocking of both units Walk your property before scheduling inspections Both units are not ready for inspection Not a complete list
Miscellaneous Correction
Corrective Action Required
07/17/2024
3729 and 3731 SW Knoxville. All rough Garage anchor bolts need to be tightened down Garage anchor bolts need to be located in the middle 1/3 of sole plate Have engineer address where the garage South side sole plate does not fully rest on the foundation wall Nail garage exterior corners to code Top of chase in garage needs to be fire blocked at Powder bathroom ceiling/floor joist needs to be doubled for tub above LIB in hallway to basement only is strapped on one side LSTRA 15 strap is not installed in entry LIB in bedroom one is not installed Nail is missing in bedroom 1 joist hanger at girder truss and truss All of stud pack in bedroom 1 S/E corner has been notched. Have engineer address LIB in bathroom 1 is not nailed down Attic access hatch? Nail upper stair well corner to code (N/W corner) Have engineer address broken truss with sistered 2x4 above bedroom 4 LIB in bedroom two is not nailed off completely Third 2x10 flush at stair way is not supported and is load bearing Fire block electrical ground wire at fire wall Gas gauge is at 0 PSI 3731 Tighten down anchor bolts in garage Two air supply lines in garage has a unbraced span over 10 feet Install anchor bolt within 4-12 inches from the end at garage North wall Have engineer address garage Northside sole plate not fully supported by foundation wall Installed garage anchor bolts in the middle 1/3 of sole plate Fire block top of chase in garage Install double ceiling/floor joist in powder bathroom to support tub above per plan Install LFSTA in entry LIB in stairwell is missing its second strap 2x10 ceiling joist in garage behind entry closet has been over notched for waste line LIB behind shower in bathroom 1 is missing nails Nail walk in closet corner to code Attic access hatch? Nail outside corner of bedroom 3 to code Nail upper stairwell S/W corner to code Triple 2x10 in basement is not fully supported by wall at the basement stairs Blocked off ceiling/floor joist in basement above HVAC needs joist hangers installed
Rated Assembly Inspection Failed 7/17/2024 7/17/2024 07/17/2024
Miscellaneous Correction
Corrective Action Required
07/17/2024
3729 and 3731. Rated assembly 3729 Fire block large gap at ridge 3731 Fire block large gap at ridge Fire decking joints that are larger than 1/4 of an inch wide needs to be fire sealed
Erosion Control Inspection Residential Partial 7/17/2024 07/17/2024
Miscellaneous Correction
Resolved
07/17/2024
Full erosion control is in place and must be maintained until CofO
Miscellaneous Correction
Informational
07/17/2024
Full erosion control is in place and must be maintained until CofO
All Rough Inspection - Residential Failed 7/24/2024 7/24/2024 07/24/2024
Miscellaneous Correction
Resolved
07/24/2024
3729 and 3731 SW Knoxville. All rough 3729 Garage anchor bolts need to be located in the middle 1/3 of sole plate Address over notched stud in garage on south side at sole plate Nail garage exterior corners to code Top of chase in garage needs to be fire blocked at waste line and HVAC LIB in hallway to basement only is strapped on one side (one stud is not nailed) All of stud pack in bedroom 1 S/E corner has been notched. Have engineer address LIB in bathroom 1 is not nailed down LIB in bedroom two is not nailed off completely Fire block electrical ground (bond) wire at fire wall 3731 Fire block top of chase in garage LIB in stairwell is missing its second strap (not all studs are nailed) LIB behind shower in bathroom 1 is missing nails (still missing one stud)
Miscellaneous Correction
Corrective Action Required
07/24/2024
3729 and 3731 SW Knoxville. All rough 3729 Garage anchor bolts need to be located in the middle 1/3 of sole plate Address over notched stud in garage on south side at sole plate Nail garage exterior corners to code Top of chase in garage needs to be fire blocked at waste line and HVAC LIB in hallway to basement only is strapped on one side (one stud is not nailed) All of stud pack in bedroom 1 S/E corner has been notched. Have engineer address LIB in bathroom 1 is not nailed down LIB in bedroom two is not nailed off completely Fire block electrical ground (bond) wire at fire wall 3731 Fire block top of chase in garage LIB in stairwell is missing its second strap (not all studs are nailed) LIB behind shower in bathroom 1 is missing nails (still missing one stud)
Gas Service Inspection - Residential Passed 7/24/2024 7/24/2024 07/24/2024
Miscellaneous Correction
Resolved
07/24/2024
Gas in unit 3729 read 0 at the time of inspection Unit 3731 passed
Rated Assembly Inspection Failed 7/24/2024 7/24/2024 07/24/2024
Miscellaneous Correction
Resolved
07/24/2024
3729 and 3731. Rated assembly 3729 Passed 3731 Fire decking joints that are larger than 1/4 of an inch wide needs to be fire sealed
Miscellaneous Correction
Corrective Action Required
07/24/2024
3729 and 3731. Rated assembly 3729 Passed 3731 Fire decking joints that are larger than 1/4 of an inch wide needs to be fire sealed
All Rough Inspection - Residential Passed 7/25/2024 7/25/2024 07/25/2024
Miscellaneous Correction
Resolved
07/25/2024
3729 and 3731 SW Knoxville. All rough 3729 Garage anchor bolts need to be located in the middle 1/3 of sole plate Address over notched stud in garage on south side at sole plate Nail garage exterior corners to code Top of chase in garage needs to be fire blocked at waste line and HVAC LIB in hallway to basement only is strapped on one side (one stud is not nailed) All of stud pack in bedroom 1 S/E corner has been notched. Have engineer address LIB in bathroom 1 is not nailed down LIB in bedroom two is not nailed off completely Fire block electrical ground (bond) wire at fire wall 3731 Fire block top of chase in garage LIB in stairwell is missing its second strap (not all studs are nailed) LIB behind shower in bathroom 1 is missing nails (still missing one stud)
Rated Assembly Inspection Passed 7/26/2024 7/26/2024 07/26/2024
Miscellaneous Correction
Corrective Action Required
07/24/2024
3729 and 3731. Rated assembly 3729 Passed 3731 Passed
Driveway Inspection Partial 8/5/2024 08/05/2024
Misc
Informational
08/05/2024
8-5-24 PS Driveway approach pre pour, forms in place and aggregate compacted, approved to pour
Sidewalk Inspection Partial 8/5/2024 08/05/2024
Misc
Informational
08/05/2024
8-5-24 PS Sidewalk pre pour, forms in place, aggregate compacted, approved to pour
Piers/Caissons Inspection - Residential Not Ready 8/12/2024 08/12/2024
Miscellaneous Correction
Corrective Action Required
08/12/2024
Permit holder scheduled a pier inspection on a duplex. Only one side of the duplex was ready and passed a pier inspection (3731). The other side was not ready for inspection.
Erosion Control Inspection Residential Failed 8/12/2024 08/12/2024
Miscellaneous Correction
Resolved
08/12/2024
Full erosion control is in place and must be maintained until CofO
Miscellaneous Correction
Corrective Action Required
08/12/2024
-Front of the property is missing proper erosion control measures. -Full erosion control must be in place and maintained until CofO
Piers/Caissons Inspection - Residential Passed 8/14/2024 08/14/2024
Miscellaneous Correction
Resolved
08/14/2024
Permit holder scheduled a pier inspection on a duplex. Only one side of the duplex was ready and passed a pier inspection (3731). The other side was not ready for inspection.
Sidewalk Inspection Passed 8/22/2024 8/22/2024 08/22/2024
Misc
Informational
08/05/2024
8-5-24 PS Sidewalk pre pour, forms in place, aggregate compacted, approved to pour 8-22-24 PS Sidewalk meets ADA and LS specs
Driveway Inspection Passed 8/22/2024 8/22/2024 08/22/2024
Misc
Informational
08/05/2024
8-5-24 PS Driveway approach pre pour, forms in place and aggregate compacted, approved to pour 8-22-24 PS Driveway approach meets LS and ADA specs
Occupancy Inspection - Codes Residential Failed 9/24/2024 9/24/2024 09/24/2024
Miscellaneous Correction
Corrective Action Required
09/24/2024
3729 and 3731 SW Knoxville. Occupancy 3729 First riser up from the main living area is greater than code allowed 7 3/4 inches Corner bracket in back deck ledger board to house ledger is not installed Water anti hammer arrestor is not installed under the sink Fire block gap in the sheet rock located in the garage where the overhead door track meets the ceiling Hand rail going up stairs does not allow 1 1/2 inch’s of grip space First to second riser going into the basement has more the the codes Allowance 3/8 of an inch difference Sump pump receptacle needs to state it is non GFCI protected Hot water tank needs a lock out installed at the panel 3731 First riser going up stairs from the main entry is greater than the code allowance of 7 3/4 inches in height Hand rail going up stairs does not allow for the code allowance of 1 1/2 inches of grip space Hot water tank needs a lock out installed at the panel Both units sod and splash pads needs to be installed Seal all exterior penetrations As graded plot plan is not uploaded Pay $381.59 in fees associated with this permit
Occupancy Inspection - Codes Residential Ready for Temp CO 9/26/2024 9/26/2024 09/26/2024
Miscellaneous Correction
Resolved
09/26/2024
3729 and 3731 SW Knoxville. Occupancy 3729 First riser up from the main living area is greater than code allowed 7 3/4 inches Corner bracket in back deck ledger board to house ledger is not installed Water anti hammer arrestor is not installed under the sink Fire block gap in the sheet rock located in the garage where the overhead door track meets the ceiling Hand rail going up stairs does not allow 1 1/2 inch’s of grip space First to second riser going into the basement has more the the codes Allowance 3/8 of an inch difference Sump pump receptacle needs to state it is non GFCI protected Hot water tank needs a lock out installed at the panel 3731 First riser going up stairs from the main entry is greater than the code allowance of 7 3/4 inches in height Hand rail going up stairs does not allow for the code allowance of 1 1/2 inches of grip space Hot water tank needs a lock out installed at the panel Both units sod and splash pads needs to be installed Seal all exterior penetrations As graded plot plan is not uploaded Pay $381.59 in fees associated with this permit
Miscellaneous Correction
Corrective Action Required
09/26/2024
3729 and 3731 SW Knoxville. Occupancy (2) Both units sod and splash pads needs to be installed Seal all exterior penetrations As graded plot plan is not uploaded Check back decks for missing nails at hangers and missing bracket at ledger to rim joist Both units passed for TCO only
Erosion Control Inspection Residential Partial 9/26/2024 09/26/2024
Miscellaneous Correction
Resolved
09/26/2024
-Front of the property is missing proper erosion control measures. -Full erosion control must be in place and maintained until CofO
Miscellaneous Correction
Informational
09/26/2024
Full erosion control measures are in place and must be maintained until CofO
Plot Plan Inspection Passed 10/9/2024 10/09/2024
Erosion Control Inspection Residential Passed 10/9/2024 10/09/2024
Miscellaneous Correction
Resolved
10/09/2024
Full erosion control measures are in place and must be maintained until CofO
Occupancy Inspection - Codes Residential Full C of O 10/16/2024 10/16/2024 10/16/2024
Miscellaneous Correction
Resolved
10/16/2024
3729 and 3731 SW Knoxville. Occupancy (2) Both units sod and splash pads needs to be installed Seal all exterior penetrations As graded plot plan is not uploaded Check back decks for missing nails at hangers and missing bracket at ledger to rim joist Both units passed for TCO only
Documents & Images
Date Uploaded File Type Document Name
03/11/2024 OS #84 - ENGINEERED PLANS
03/11/2024 OS #84 - Permit App
03/11/2024 OS #84 - PLOT PLAN
03/11/2024 OS #84 - TRUSS DETAILS
03/11/2024 OS #84 - TRUSS LAYOUT
03/14/2024 Plot Plan APPROVED PLOT PLAN
03/14/2024 Permit Codes Residential Plan Review
03/15/2024 24-0315 OS #84 - Twin Honeydew - Farmhouse - DL10x12 - CITY COMMENTS
03/18/2024 Permit Codes Residential Plan Review
03/19/2024 24-0228 OS #84 - Twin Honeydew - Farmhouse - DL10x12
03/19/2024 Permit Codes Residential Plan Review
03/20/2024 OS #84 - Twin Honeydew 240307
03/21/2024 Approved Plans APPROVED PLANS
03/21/2024 Approved Plans APPROVED TRUSS PACKAGE
03/21/2024 Approved Plans APPROVED TRUSS LAYOUT
03/21/2024 Permit Codes Residential Plan Review
03/21/2024 Permit DS Building Permit
03/21/2024 Receipt Receipt for transaction:2024-001792
03/29/2024 3RD Party Insp Report 3rd Party Footing Inspection Report 3-29-24
04/01/2024 Letter INSPECTION SUMMARY
04/01/2024 Letter INSPECTION SUMMARY
04/16/2024 Letter INSPECTION SUMMARY
04/17/2024 Letter INSPECTION SUMMARY
04/17/2024 Letter INSPECTION SUMMARY
04/19/2024 Letter INSPECTION SUMMARY
04/22/2024 Letter INSPECTION SUMMARY
04/24/2024 Letter INSPECTION SUMMARY
04/24/2024 Letter INSPECTION SUMMARY
06/14/2024 Letter INSPECTION SUMMARY
06/14/2024 Letter INSPECTION SUMMARY
07/11/2024 Letter INSPECTION SUMMARY
07/11/2024 Letter INSPECTION SUMMARY
07/15/2024 Letter INSPECTION SUMMARY
07/17/2024 Letter INSPECTION SUMMARY
07/17/2024 Letter INSPECTION SUMMARY
07/17/2024 Letter INSPECTION SUMMARY
07/17/2024 Letter INSPECTION SUMMARY
07/17/2024 Letter INSPECTION SUMMARY
07/22/2024 SUMMIT - FJ UNDER TUB - 240719
07/24/2024 3RD Party Insp Report OS 84 - FIELD ISSUES - 240723
07/24/2024 3RD Party Insp Report OS 84 Truss letter
07/24/2024 Letter INSPECTION SUMMARY
07/24/2024 Letter INSPECTION SUMMARY
07/24/2024 Letter INSPECTION SUMMARY
07/25/2024 Letter INSPECTION SUMMARY
07/26/2024 Letter INSPECTION SUMMARY
08/05/2024 Letter INSPECTION SUMMARY
08/05/2024 Letter INSPECTION SUMMARY
08/12/2024 Letter INSPECTION SUMMARY
08/12/2024 Letter INSPECTION SUMMARY
08/14/2024 Letter INSPECTION SUMMARY
08/22/2024 Letter INSPECTION SUMMARY
08/22/2024 Letter INSPECTION SUMMARY
09/24/2024 Receipt Receipt for transaction:2024-007877
09/24/2024 Letter INSPECTION SUMMARY
09/26/2024 Letter INSPECTION SUMMARY
09/26/2024 Letter INSPECTION SUMMARY
10/08/2024 Plot Plan approved as graded plot plan
10/09/2024 Letter INSPECTION SUMMARY
10/09/2024 Letter INSPECTION SUMMARY
10/16/2024 Certificate/License Codes Temporary Certificate of Occupancy
10/16/2024 Receipt Receipt for transaction:2024-008361
10/16/2024 Letter Field Certificate of Occupancy
10/16/2024 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home