Permit Application Status

PRRES20236539


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20236539
Building Permit - Residential
Certificate of Occupancy
NEW 3 OR 4 FAMILY
NEW FOURPLEX. FINISHED/UNFINISHED BASEMENT. ROOF TRUSSES. STOP WORK ORDER generated on 02/08/2024 12:00 AM by username 'Kyle Beard'. STOP WORK ORDER removed on 02/09/2024 12:00 AM by username 'Kyle Beard'. STOP WORK ORDER generated on 04/25/2024 12:00 AM by username 'Dustin Agcopra'. STOP WORK ORDER removed on 04/25/2024 12:00 AM by username 'Dustin Agcopra'.
12/14/2023
01/02/2024
06/19/2024
09/16/2024
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
CARUTHERS ELECTRICAL LLC, Address:30905 E TRUMAN RD, Phone:(816) 508-9050  
BILL'S PLUMBING SERVICE LLC, Address:308 E PARK STREET, Phone:(913) 829-8213  
JASONH@CLOVERANDHIVE.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee for New Duplex $4,448.75 $4,448.75 Paid 01/02/2024
Water Tap Fee $15,040.00 $15,040.00 Paid 01/02/2024
Water Meter Fee $2,721.84 $2,721.84 Paid 01/02/2024
Sanitary Sewer Development Fee $8,636.00 $8,636.00 Paid 01/02/2024
Right of Way Permit Fee $85.00 $85.00 Paid 01/02/2024
Residential Excise Tax Fee $2,480.64 $2,480.64 Paid 01/02/2024
3rd and Subsequent Inspection Fee (Per Hour) $75.00 $75.00 Paid 06/14/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 06/14/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 06/21/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 06/21/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 06/25/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 06/25/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 06/25/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 08/22/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 08/22/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Failed 2/6/2024 02/06/2024
Miscellaneous Correction
Corrective Action Required
02/06/2024
All units for this permit needs to have gravel spread for lot access and erosion control measures. Full erosion control must be completed and maintained until CofO.
Sewer Service Inspection - R Partial 2/8/2024 02/08/2024
Miscellaneous Correction
Informational
02/08/2024
3737 sewer passed. This is a partial pass only. Other units will be called in at a later date
Footing Inspection - Residential Passed 2/9/2024 02/09/2024
Miscellaneous Correction
Informational
02/09/2024
Footing inspection passed by a third party
Erosion Control Inspection Residential Partial 2/12/2024 2/12/2024 02/12/2024
Miscellaneous Correction
Resolved
02/12/2024
All units for this permit needs to have gravel spread for lot access and erosion control measures. Full erosion control must be completed and maintained until CofO.
Miscellaneous Correction
Corrective Action Required
02/12/2024
Full erosion control is in place. Full erosion control must be maintained until CofO
Sewer Service Inspection - R Passed 2/13/2024 02/13/2024
Miscellaneous Correction
Informational
02/08/2024
3737 sewer passed. This is a partial pass only. Other units will be called in at a later date
Water Service Inspection - R Passed 2/14/2024 02/14/2024
Miscellaneous Correction
Informational
02/14/2024
All four units passed
Underslab Electrical Inspection - Residential Passed 2/16/2024 2/16/2024 02/16/2024
Underslab Plumbing Inspection - Residential Failed 2/16/2024 2/16/2024 02/16/2024
Miscellaneous Correction
Corrective Action Required
02/16/2024
Drain tile must have a minimum of 2 inches of crushed stone or gravel under it according to the approved plans under foundation drain and raised slab detail Remove all lumber from forms in contact with the earth R408.5
Underslab Plumbing Inspection - Residential Passed 2/16/2024 02/16/2024
Miscellaneous Correction
Resolved
02/16/2024
Drain tile must have a minimum of 2 inches of crushed stone or gravel under it according to the approved plans under foundation drain and raised slab detail Remove all lumber from forms in contact with the earth R408.5
All Rough Inspection - Residential Partial 3/21/2024 3/21/2024 03/21/2024
Miscellaneous Correction
Informational
03/21/2024
-Garage portal passed only. Okay to cover This is a partial pass only
Erosion Control Inspection Residential Failed 4/11/2024 04/11/2024
Miscellaneous Correction
Resolved
04/11/2024
Full erosion control is in place. Full erosion control must be maintained until CofO
Miscellaneous Correction
Corrective Action Required
04/11/2024
Repair or replace damaged silt fence along the street and between buildings. Full erosion control must be maintained until CofO
Rated Assembly Inspection Failed 4/15/2024 4/15/2024 04/15/2024
Miscellaneous Correction
Corrective Action Required
04/15/2024
3733 SW Clayton. Rated assembly Ok 3735 garage south wall at the top has plywood attached to it Entry north wall has metal bent and exposes a gap Fire blocking nominal Luis missing along north wall on main floor Rafter bracing repair in upstairs bedroom 1 needs to be replaced by fire protection plywood 3737 entry rated wall has plywood attached to the top Electrical service cable along north wall needs to be fire caulked Gap at the south rated wall along the roof line Gap above ceiling in bedroom 1 to the north/west corner 3739 Roof decking has a larger than 1/4 inch gap on the east side
Electrical Service Inspection Passed 4/15/2024 4/15/2024 04/15/2024
Gas Service Inspection - Residential Passed 4/15/2024 4/15/2024 04/15/2024
All Rough Inspection - Residential Failed 4/15/2024 4/15/2024 04/15/2024
Miscellaneous Correction
Informational
03/21/2024
-Garage portal passed only. Okay to cover This is a partial pass only
Miscellaneous Correction
Corrective Action Required
04/15/2024
3733 SW Clayton. All rough HVAC supply lines in garage ceiling, needs to be supported at 10 feet on center or less Fire blocking is missing in two cavities on front porch ceiling Front entry corner and bedroom 2 corner needs to be nailed to code GB bracing missing in kitchen LIB is missing in the utility north to south wall Water faucet pipe is out of the wall in corner of rec room Electrical service line is below the ceiling height in basement closet of bedroom 3 A/C supply line is below the ceiling height in bedroom 3 3735 Fire blocking is missing on front porch cantilever Cut ceiling joist in garage for blocked out plumbing needs joist hangers installed Top plate in entry closet needs to be fire blocked Vertical 2x4’s in entry at stairwell have been cut into instead of a solid column Have engineers report on broken truss above main living area at stairwell Nail corners to code GB bracing is missing in kitchen Have engineers report on trusses in bedroom 1 Nails are missing in LIB at the top corner in bedroom 1 Top of chase in rec room needs to be fire blocked Electrical receptacle is in between two walls in the basement rec room Electric service cable and gas line are below ceiling height in bedroom 3 closet 3737 HVAC line in garage ceiling needs a support bracket installed being over 10 feet between supports LIB along north garage wall is not installed Blocked out ceiling joist in garage for plumbing needs joist hangers installed Vertical 2x4’s in entry at stairwell have been cut into instead of a solid column GB bracing in kitchen is not installed Chase in bedroom 2 needs to be fire blocked at the ceiling Nails missing in LIB in bathroom 1 Top of chases in rec room needs to be fire blocked Electrical in rec room is in between walls Plumbing waste line in basement closet needs a BOCA plate installed Top plate in basement closet needs to be fire blocked Closet in bedroom 3 has electrical and gas lines below ceiling height 3739 Fire blocking is broken out above Ibeam in garage Second LIB in garage is not installed GB bracing in kitchen is not installed Fire block top of chase in rec room Fire block top plate in closet of basement Nail all units CS-WSP according to code
Rated Assembly Inspection Failed 4/18/2024 4/18/2024 04/18/2024
Miscellaneous Correction
Resolved
04/18/2024
3733 SW Clayton. Rated assembly Ok 3735 garage south wall at the top has plywood attached to it Entry north wall has metal bent and exposes a gap Fire blocking nominal Luis missing along north wall on main floor Rafter bracing repair in upstairs bedroom 1 needs to be replaced by fire protection plywood 3737 entry rated wall has plywood attached to the top Electrical service cable along north wall needs to be fire caulked Gap at the south rated wall along the roof line Gap above ceiling in bedroom 1 to the north/west corner 3739 Roof decking has a larger than 1/4 inch gap on the east side
Miscellaneous Correction
Corrective Action Required
04/18/2024
3733 SW Clayton. Rated assembly Chase ceiling in bedroom 2 has 7/16 plywood installed for Fire blocking. Code requires 3/4 of an inch or larger 3735 garage south wall at the top has plywood attached to it Rafter bracing repair in upstairs bedroom 1 south wall needs to be replaced by fire protection plywood Chase ceiling in bedroom 2 has 7/16 plywood installed for Fire blocking. Code requires 3/4 of an inch or larger Replace hole in rated assembly in basement bathroom 3737 entry rated wall has plywood attached to the top Electrical service cable along north wall needs to be fire caulked Chase ceiling in bedroom 2 has 7/16 plywood installed for Fire blocking. Code requires 3/4 of an inch or larger Gap above ceiling in bedroom 1 to the north/west corner (normal 7/16 plywood is not considered rated fire blocking material) 3739 Chase ceiling in bedroom 2 has 7/16 plywood installed for Fire blocking. Code requires 3/4 of an inch or larger
All Rough Inspection - Residential Failed 4/18/2024 4/18/2024 04/18/2024
Miscellaneous Correction
Informational
04/15/2024
-Garage portal passed only. Okay to cover This is a partial pass only
Miscellaneous Correction
Resolved
04/18/2024
3733 SW Clayton. All rough HVAC supply lines in garage ceiling, needs to be supported at 10 feet on center or less Fire blocking is missing in two cavities on front porch ceiling Front entry corner and bedroom 2 corner needs to be nailed to code GB bracing missing in kitchen LIB is missing in the utility north to south wall Water faucet pipe is out of the wall in corner of rec room Electrical service line is below the ceiling height in basement closet of bedroom 3 A/C supply line is below the ceiling height in bedroom 3 3735 Fire blocking is missing on front porch cantilever Cut ceiling joist in garage for blocked out plumbing needs joist hangers installed Top plate in entry closet needs to be fire blocked Vertical 2x4’s in entry at stairwell have been cut into instead of a solid column Have engineers report on broken truss above main living area at stairwell Nail corners to code GB bracing is missing in kitchen Have engineers report on trusses in bedroom 1 Nails are missing in LIB at the top corner in bedroom 1 Top of chase in rec room needs to be fire blocked Electrical receptacle is in between two walls in the basement rec room Electric service cable and gas line are below ceiling height in bedroom 3 closet 3737 HVAC line in garage ceiling needs a support bracket installed being over 10 feet between supports LIB along north garage wall is not installed Blocked out ceiling joist in garage for plumbing needs joist hangers installed Vertical 2x4’s in entry at stairwell have been cut into instead of a solid column GB bracing in kitchen is not installed Chase in bedroom 2 needs to be fire blocked at the ceiling Nails missing in LIB in bathroom 1 Top of chases in rec room needs to be fire blocked Electrical in rec room is in between walls Plumbing waste line in basement closet needs a BOCA plate installed Top plate in basement closet needs to be fire blocked Closet in bedroom 3 has electrical and gas lines below ceiling height 3739 Fire blocking is broken out above Ibeam in garage Second LIB in garage is not installed GB bracing in kitchen is not installed Fire block top of chase in rec room Fire block top plate in closet of basement Nail all units CS-WSP according to code
All Rough Inspection - Residential Failed 4/19/2024 4/19/2024 04/19/2024
Miscellaneous Correction
Resolved
04/19/2024
-Garage portal passed only. Okay to cover This is a partial pass only
Miscellaneous Correction
Corrective Action Required
04/19/2024
3733 SW Clayton. All rough HVAC supply lines in garage ceiling, needs to be supported at 10 feet on center or less 3735 Vertical 2x4’s in entry at stairwell have been cut into instead of a solid column (studs were added but vertical load under new studs needs to be supported for proper load transfer) Have engineers report on broken truss above main living area at stairwell Replace hole in rated assembly in basement bathroom 3737 Vertical 2x4’s in entry at stairwell have been cut into instead of a solid column (support vertical load of new studs that were installed for proper load transfer) Plumbing waste line in basement closet needs a BOCA plate installed Top plate in basement closet needs to be fire blocked Replace hole in rated assembly in basement bathroom 3739 Nail all units CS-WSP according to code
Rated Assembly Inspection Failed 4/19/2024 4/19/2024 04/19/2024
Miscellaneous Correction
Resolved
04/19/2024
3733 SW Clayton. Rated assembly Chase ceiling in bedroom 2 has 7/16 plywood installed for Fire blocking. Code requires 3/4 of an inch or larger 3735 garage south wall at the top has plywood attached to it Rafter bracing repair in upstairs bedroom 1 south wall needs to be replaced by fire protection plywood Chase ceiling in bedroom 2 has 7/16 plywood installed for Fire blocking. Code requires 3/4 of an inch or larger Replace hole in rated assembly in basement bathroom 3737 entry rated wall has plywood attached to the top Electrical service cable along north wall needs to be fire caulked Chase ceiling in bedroom 2 has 7/16 plywood installed for Fire blocking. Code requires 3/4 of an inch or larger Gap above ceiling in bedroom 1 to the north/west corner (normal 7/16 plywood is not considered rated fire blocking material) 3739 Chase ceiling in bedroom 2 has 7/16 plywood installed for Fire blocking. Code requires 3/4 of an inch or larger
Miscellaneous Correction
Corrective Action Required
04/19/2024
3733 SW Clayton. Rated assembly Chase ceiling in bedroom 2 has 7/16 plywood installed for Fire blocking. Code requires 3/4 of an inch or larger 3735 garage south wall at the top has plywood attached to it Rafter bracing repair in upstairs bedroom 1 south wall needs to be replaced by fire protection plywood Chase ceiling in bedroom 2 has 7/16 plywood installed for Fire blocking. Code requires 3/4 of an inch or larger Replace hole in rated assembly in basement bathroom 3737 entry rated wall has plywood attached to the top Electrical service cable along north wall needs to be fire caulked Chase ceiling in bedroom 2 has 7/16 plywood installed for Fire blocking. Code requires 3/4 of an inch or larger Gap above ceiling in bedroom 1 to the north/west corner (normal 7/16 plywood is not considered rated fire blocking material) Replace hole in rated assembly in basement north wall 3739 Chase ceiling in bedroom 2 has 7/16 plywood installed for Fire blocking. Code requires 3/4 of an inch or larger
All Rough Inspection - Residential Passed 4/23/2024 4/23/2024 04/23/2024
Miscellaneous Correction
Resolved
04/23/2024
3733 SW Clayton. All rough HVAC supply lines in garage ceiling, needs to be supported at 10 feet on center or less 3735 Vertical 2x4’s in entry at stairwell have been cut into instead of a solid column (studs were added but vertical load under new studs needs to be supported for proper load transfer) Have engineers report on broken truss above main living area at stairwell Replace hole in rated assembly in basement bathroom 3737 Vertical 2x4’s in entry at stairwell have been cut into instead of a solid column (support vertical load of new studs that were installed for proper load transfer) Plumbing waste line in basement closet needs a BOCA plate installed Top plate in basement closet needs to be fire blocked Replace hole in rated assembly in basement bathroom 3739 Nail all units CS-WSP according to code
Rated Assembly Inspection Passed 4/23/2024 4/23/2024 04/23/2024
Miscellaneous Correction
Resolved
04/23/2024
3733 SW Clayton. Rated assembly Chase ceiling in bedroom 2 has 7/16 plywood installed for Fire blocking. Code requires 3/4 of an inch or larger 3735 garage south wall at the top has plywood attached to it Rafter bracing repair in upstairs bedroom 1 south wall needs to be replaced by fire protection plywood Chase ceiling in bedroom 2 has 7/16 plywood installed for Fire blocking. Code requires 3/4 of an inch or larger Replace hole in rated assembly in basement bathroom 3737 entry rated wall has plywood attached to the top Electrical service cable along north wall needs to be fire caulked Chase ceiling in bedroom 2 has 7/16 plywood installed for Fire blocking. Code requires 3/4 of an inch or larger Gap above ceiling in bedroom 1 to the north/west corner (normal 7/16 plywood is not considered rated fire blocking material) Replace hole in rated assembly in basement north wall 3739 Chase ceiling in bedroom 2 has 7/16 plywood installed for Fire blocking. Code requires 3/4 of an inch or larger
Erosion Control Inspection Residential Passed 04/25/2024
Miscellaneous Correction
Corrective Action Required
04/11/2024
Repair or replace damaged silt fence along the street and between buildings. Full erosion control must be maintained until CofO
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
04/25/2024
4-25-24 Dustin A, .EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Rated Assembly Inspection Passed 5/1/2024 05/01/2024
Driveway Inspection Passed 5/10/2024 5/10/2024 05/17/2024
Misc
Informational
05/10/2024
5-10-24 Dustin A, This is for units 3733-3739, DW has been formed and compacted to city specs. Approved to pour 5-17-24 Dustin A, DW's are poured to city specs. Passed
Sidewalk Inspection Passed 5/10/2024 5/10/2024 05/17/2024
Misc
Informational
05/10/2024
5-10-24 Dustin A, SW has been formed and compacted to city specs, Approved to pour 5-17-24 Dustin A, SW's has been pouredto city specs, Passed
Driveway Inspection Passed 5/17/2024 5/17/2024 05/17/2024
Misc
Informational
05/10/2024
5-10-24 Dustin A, This is for units 3733-3739, DW has been formed and compacted to city specs. Approved to pour
Sidewalk Inspection Passed 5/17/2024 5/17/2024 05/17/2024
Piers/Caissons Inspection - Residential Failed 6/12/2024 6/12/2024 06/12/2024
Miscellaneous Correction
Informational
06/12/2024
3737 piers for back deck passed only This is a partial pass for piers. Other units will be scheduled at a later date
Occupancy Inspection - Codes Residential Not Ready 6/13/2024 6/13/2024 06/13/2024
Miscellaneous Correction
Corrective Action Required
06/13/2024
3733, 3735, 3737 and 3739 SW Clayton Occupancy 3733 Front porch needs guard rail fall protection installed Main living area sliding patio door needs fall protection installed Kitchen backsplash receptacles needs spark rings installed Remove dust covers from smoke detectors Stairs to the basement have 8 inches of riser height. Code is no more than 7 3/4 inches in riser height Garage to house self closing and locking door needs to be adjusted to close Fire block all garage holes and or penetrations in sheet rock 3735 Front porch needs a guard rail installed Main living room sliding patio door needs fall protection installed Remove smoke dust covers Basement patio door does not have a secondary lock installed Electrical whip for hot water heater needs to be secured Garage to house door is missing the seal and could not be tested Fire block all garage holes and or penetrations in sheet rock 3737 Entry to main floor is missing the stair hand rail Unit is not ready for inspection 3739 Main entry stair well has first to second riser height difference of more than 3/8 of an inch Spark ring is not installed in kitchen backsplash electrical receptacle Spindle in upper stair well is not properly secured Remove smoke detector dust covers Attic access panel is not properly sealed Back patio is being installed and is not ready for inspection Garage to house self closing door is not sealing correctly Fire block garage holes and or penetrations in sheet rock -Not all units have exterior A/C units installed for inspection Not ready for inspection -All units still needs sod, splash pads and sump pump extensions installed -All units have not been graded for plot plan inspection Pay not ready fees associated with this permit
Erosion Control Inspection Residential Failed 6/13/2024 06/13/2024
Miscellaneous Correction
Resolved
06/13/2024
Repair or replace damaged silt fence along the street and between buildings. Full erosion control must be maintained until CofO
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
06/13/2024
4-25-24 Dustin A, .EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Miscellaneous Correction
Corrective Action Required
06/13/2024
Erosion control measures are not in place at the from of the property. Full erosion control measures must be maintained until full CofO
Piers/Caissons Inspection - Residential Failed 6/13/2024 6/13/2024 06/13/2024
Miscellaneous Correction
Informational
06/12/2024
3737 and 3739 piers for back deck passed This is a partial pass for piers. Other units will be scheduled at a later date
Piers/Caissons Inspection - Residential Failed 6/17/2024 6/17/2024 06/17/2024
Miscellaneous Correction
Informational
06/13/2024
3737,3739 and 3735 piers for back deck passed This is a partial pass for piers. Other units will be scheduled at a later date
Erosion Control Inspection Residential Failed 6/17/2024 06/17/2024
Miscellaneous Correction
Corrective Action Required
06/13/2024
Erosion control measures are not in place at the front of the property. Full erosion control measures must be maintained until full CofO
Occupancy Inspection - Codes Residential Failed 6/17/2024 6/17/2024 06/17/2024
Miscellaneous Correction
Resolved
06/17/2024
3733, 3735, 3737 and 3739 SW Clayton Occupancy 3733 Front porch needs guard rail fall protection installed Main living area sliding patio door needs fall protection installed Kitchen backsplash receptacles needs spark rings installed Remove dust covers from smoke detectors Stairs to the basement have 8 inches of riser height. Code is no more than 7 3/4 inches in riser height Garage to house self closing and locking door needs to be adjusted to close Fire block all garage holes and or penetrations in sheet rock 3735 Front porch needs a guard rail installed Main living room sliding patio door needs fall protection installed Remove smoke dust covers Basement patio door does not have a secondary lock installed Electrical whip for hot water heater needs to be secured Garage to house door is missing the seal and could not be tested Fire block all garage holes and or penetrations in sheet rock 3737 Entry to main floor is missing the stair hand rail Unit is not ready for inspection 3739 Main entry stair well has first to second riser height difference of more than 3/8 of an inch Spark ring is not installed in kitchen backsplash electrical receptacle Spindle in upper stair well is not properly secured Remove smoke detector dust covers Attic access panel is not properly sealed Back patio is being installed and is not ready for inspection Garage to house self closing door is not sealing correctly Fire block garage holes and or penetrations in sheet rock -Not all units have exterior A/C units installed for inspection Not ready for inspection -All units still needs sod, splash pads and sump pump extensions installed -All units have not been graded for plot plan inspection Pay not ready fees associated with this permit
Miscellaneous Correction
Corrective Action Required
06/17/2024
3733, 3735, 3737 and 3739 SW Clayton Occupancy 3733 Front porch needs guard rail fall protection installed Main living area sliding patio door needs fall protection installed Kitchen backsplash receptacles needs spark rings installed Remove dust covers from smoke detectors Stairs to the basement have 8 inches of riser height. Code is no more than 7 3/4 inches in riser height Garage to house self closing and locking door needs to be adjusted to close Fire block all garage holes and or penetrations in sheet rock 3735 Front porch needs a guard rail installed Main living room sliding patio door needs fall protection installed Remove smoke dust covers Basement patio door does not have a secondary lock installed Electrical whip for hot water heater needs to be secured Garage to house door is missing the seal and could not be tested Fire block all garage holes and or penetrations in sheet rock 3737 Stair spindle is not properly installed in stair case from main living area to upper rooms Remove protective covering from alarm detector in mechanical room 3739 Main entry stair well has first to second riser height difference of more than 3/8 of an inch Spark ring is not installed in kitchen backsplash electrical receptacle Spindle in upper stair well is not properly secured Remove smoke detector dust covers Attic access panel is not properly sealed Back patio is being installed and is not ready for inspection Garage to house self closing door is not sealing correctly Fire block garage holes and or penetrations in sheet rock -All units still needs sod, splash pads and sump pump extensions installed -All units have not been graded for plot plan inspection
Piers/Caissons Inspection - Residential Passed 6/18/2024 6/18/2024 06/18/2024
Miscellaneous Correction
Resolved
06/18/2024
3737,3739 and 3735 piers for back deck passed This is a partial pass for piers. Other units will be scheduled at a later date
Occupancy Inspection - Codes Residential Ready for Temp CO 6/19/2024 6/19/2024 06/19/2024
Miscellaneous Correction
Resolved
06/19/2024
3733, 3735, 3737 and 3739 SW Clayton Occupancy 3733 Front porch needs guard rail fall protection installed Main living area sliding patio door needs fall protection installed Kitchen backsplash receptacles needs spark rings installed Remove dust covers from smoke detectors Stairs to the basement have 8 inches of riser height. Code is no more than 7 3/4 inches in riser height Garage to house self closing and locking door needs to be adjusted to close Fire block all garage holes and or penetrations in sheet rock 3735 Front porch needs a guard rail installed Main living room sliding patio door needs fall protection installed Remove smoke dust covers Basement patio door does not have a secondary lock installed Electrical whip for hot water heater needs to be secured Garage to house door is missing the seal and could not be tested Fire block all garage holes and or penetrations in sheet rock 3737 Stair spindle is not properly installed in stair case from main living area to upper rooms Remove protective covering from alarm detector in mechanical room 3739 Main entry stair well has first to second riser height difference of more than 3/8 of an inch Spark ring is not installed in kitchen backsplash electrical receptacle Spindle in upper stair well is not properly secured Remove smoke detector dust covers Attic access panel is not properly sealed Back patio is being installed and is not ready for inspection Garage to house self closing door is not sealing correctly Fire block garage holes and or penetrations in sheet rock -All units still needs sod, splash pads and sump pump extensions installed -All units have not been graded for plot plan inspection
Miscellaneous Correction
Corrective Action Required
06/19/2024
3733, 3735, 3737 and 3739 SW Clayton Occupancy 3733 Front porch needs guard rail fall protection installed Main living area sliding patio door needs fall protection installed Kitchen backsplash receptacles needs spark rings installed Remove dust covers from smoke detectors Stairs to the basement have 8 inches of riser height. Code is no more than 7 3/4 inches in riser height Garage to house self closing and locking door needs to be adjusted to close Fire block all garage holes and or penetrations in sheet rock 3735 Front porch needs a guard rail installed Main living room sliding patio door needs fall protection installed Remove smoke dust covers Basement patio door does not have a secondary lock installed Electrical whip for hot water heater needs to be secured Garage to house door is missing the seal and could not be tested Fire block all garage holes and or penetrations in sheet rock 3737 Passed for TCO only 3739 Main entry stair well has first to second riser height difference of more than 3/8 of an inch Spark ring is not installed in kitchen backsplash electrical receptacle Spindle in upper stair well is not properly secured Remove smoke detector dust covers Attic access panel is not properly sealed Back patio is being installed and is not ready for inspection Garage to house self closing door is not sealing correctly Fire block garage holes and or penetrations in sheet rock -All units still needs sod, splash pads and sump pump extensions installed -All units still need to have back patio stair to ground pads installed -All units have not been graded for plot plan inspection
Occupancy Inspection - Codes Residential Not Ready 6/21/2024 6/21/2024 06/21/2024
Miscellaneous Correction
Resolved
06/21/2024
3733, 3735, 3737 and 3739 SW Clayton Occupancy 3733 Front porch needs guard rail fall protection installed Main living area sliding patio door needs fall protection installed Kitchen backsplash receptacles needs spark rings installed Remove dust covers from smoke detectors Stairs to the basement have 8 inches of riser height. Code is no more than 7 3/4 inches in riser height Garage to house self closing and locking door needs to be adjusted to close Fire block all garage holes and or penetrations in sheet rock 3735 Front porch needs a guard rail installed Main living room sliding patio door needs fall protection installed Remove smoke dust covers Basement patio door does not have a secondary lock installed Electrical whip for hot water heater needs to be secured Garage to house door is missing the seal and could not be tested Fire block all garage holes and or penetrations in sheet rock 3737 Passed for TCO only 3739 Main entry stair well has first to second riser height difference of more than 3/8 of an inch Spark ring is not installed in kitchen backsplash electrical receptacle Spindle in upper stair well is not properly secured Remove smoke detector dust covers Attic access panel is not properly sealed Back patio is being installed and is not ready for inspection Garage to house self closing door is not sealing correctly Fire block garage holes and or penetrations in sheet rock -All units still needs sod, splash pads and sump pump extensions installed -All units still need to have back patio stair to ground pads installed -All units have not been graded for plot plan inspection
Miscellaneous Correction
Corrective Action Required
06/21/2024
3733, 3735, 3737 and 3739 SW Clayton Occupancy (2) 3733 Kitchen backsplash receptacle needs spark ring installed (still not installed) Stairs to the basement have 8 inches of riser height. Code is no more than 7 3/4 inches in riser height (still not ready for reinspection) Back patio deck N/E corner bracket is missing a fastener Back deck stair to ground pad is not installed Not ready for inspection 3735 Garage to house door is missing the seal and could not be tested (still not installed) Back deck joist hanger is missing fasteners Back deck stair to ground pad is not installed Not ready for reinspection 3737 Already passed for TCO only 3739 Back deck stair to ground pad is not installed Passed for TCO only -All units still needs sod, splash pads and sump pump extensions installed -All units have not been graded for plot plan inspection -All units needs as graded plot plan uploaded
Occupancy Inspection - Codes Residential Not Ready 6/24/2024 6/24/2024 06/24/2024
Miscellaneous Correction
Corrective Action Required
06/21/2024
3733, 3735, 3737 and 3739 SW Clayton Occupancy (2) -Inspection at 3733 started at 8:00am, first item checked was the kitchen backsplash receptacle spark ring. Item was not completed. -No other items were checked, due to not being ready -This is not a complete list NOT READY. Walk you property before scheduling inspections 3733 Kitchen backsplash receptacle needs spark ring installed (still not installed) Stairs to the basement have 8 inches of riser height. Code is no more than 7 3/4 inches in riser height (still not ready for reinspection) Back patio deck N/E corner bracket is missing a fastener Back deck stair to ground pad is not installed Not ready for inspection 3735 Garage to house door is missing the seal and could not be tested (still not installed) Back deck joist hanger is missing fasteners Back deck stair to ground pad is not installed Not ready for reinspection 3737 Already passed for TCO only 3739 Back deck stair to ground pad is not installed Passed for TCO only -All units still needs sod, splash pads and sump pump extensions installed -All units have not been graded for plot plan inspection -All units needs as graded plot plan uploaded
Occupancy Inspection - Codes Residential Not Ready 6/25/2024 6/25/2024 06/25/2024
Miscellaneous Correction
Resolved
06/25/2024
3733, 3735, 3737 and 3739 SW Clayton Occupancy (2) -Inspection at 3733 started at 8:00am, first item checked was the kitchen backsplash receptacle spark ring. Item was not completed. -No other items were checked, due to not being ready -This is not a complete list NOT READY. Walk you property before scheduling inspections 3733 Kitchen backsplash receptacle needs spark ring installed (still not installed) Stairs to the basement have 8 inches of riser height. Code is no more than 7 3/4 inches in riser height (still not ready for reinspection) Back patio deck N/E corner bracket is missing a fastener Back deck stair to ground pad is not installed Not ready for inspection 3735 Garage to house door is missing the seal and could not be tested (still not installed) Back deck joist hanger is missing fasteners Back deck stair to ground pad is not installed Not ready for reinspection 3737 Already passed for TCO only 3739 Back deck stair to ground pad is not installed Passed for TCO only -All units still needs sod, splash pads and sump pump extensions installed -All units have not been graded for plot plan inspection -All units needs as graded plot plan uploaded
Miscellaneous Correction
Corrective Action Required
06/25/2024
3733, 3735, 3737 and 3739 SW Clayton Occupancy (3) 3733 Kitchen microwave #17 breaker will not trip Kitchen #18 breaker needs to be an AFCI Refrigerator #9 breaker does not trip Back patio deck N/E corner bracket is missing a fastener Not ready for inspection 3735 Garage to house self closing door will not properly latch shut (Not ready for inspection. Walk your property before scheduling an inspection) 3737 Already passed for TCO only 3739 Passed for TCO only -All units still needs sod, splash pads and sump pump extensions installed -All units have not been graded for plot plan inspection -All units needs as graded plot plan uploaded Pay not ready fee associated with this
Occupancy Inspection - Codes Residential Ready for Temp CO 6/25/2024 06/25/2024
Miscellaneous Correction
Resolved
06/25/2024
3733, 3735, 3737 and 3739 SW Clayton Occupancy (3) 3733 Kitchen microwave #17 breaker will not trip Kitchen #18 breaker needs to be an AFCI Refrigerator #9 breaker does not trip Back patio deck N/E corner bracket is missing a fastener Not ready for inspection 3735 Garage to house self closing door will not properly latch shut (Not ready for inspection. Walk your property before scheduling an inspection) 3737 Already passed for TCO only 3739 Passed for TCO only -All units still needs sod, splash pads and sump pump extensions installed -All units have not been graded for plot plan inspection -All units needs as graded plot plan uploaded Pay not ready fee associated with this
Miscellaneous Correction
Corrective Action Required
06/25/2024
3733, 3735, 3737 and 3739 SW Clayton Occupancy (3) 3733 Passed for TCO only 3735 Passed for TCO only 3737 Passed for TCO only 3739 Passed for TCO only -All units still needs sod, splash pads and sump pump extensions installed -All units have not been graded for plot plan inspection -All units needs as graded plot plan uploaded
Occupancy Inspection - Codes Residential Failed 7/26/2024 07/26/2024
Miscellaneous Correction
Corrective Action Required
06/25/2024
3733, 3735, 3737 and 3739 SW Clayton Occupancy (3) 3733 Passed for TCO only 3735 Passed for TCO only 3737 Passed for TCO only 3739 Passed for TCO only -All units still needs sod, splash pads and sump pump extensions installed -All units have not been graded for plot plan inspection -All units needs as graded plot plan uploaded
Erosion Control Inspection Residential Partial 8/13/2024 08/13/2024
Miscellaneous Correction
Resolved
08/13/2024
Erosion control measures are not in place at the front of the property. Full erosion control measures must be maintained until full CofO
Miscellaneous Correction
Informational
08/13/2024
Erosion control measures are in place and must be maintained until CofO
Occupancy Inspection - Codes Residential Ready for Temp CO 8/13/2024 08/13/2024
Miscellaneous Correction
Resolved
08/13/2024
3733, 3735, 3737 and 3739 SW Clayton Occupancy (3) 3733 Passed for TCO only 3735 Passed for TCO only 3737 Passed for TCO only 3739 Passed for TCO only -All units still needs sod, splash pads and sump pump extensions installed -All units have not been graded for plot plan inspection -All units needs as graded plot plan uploaded
Miscellaneous Correction
Corrective Action Required
08/13/2024
3733, 3735, 3737 and 3739 SW Clayton Occupancy (3) 3733 Passed for TCO only 3735 Passed for TCO only 3737 Passed for TCO only 3739 Passed for TCO only -All units still needs sod, splash pads and sump pump extensions installed -All units have not been graded for plot plan inspection -All units needs as graded plot plan uploaded Builder sent in a TCO extension form and was expected by the City
Plot Plan Inspection Passed 8/21/2024 08/21/2024
Occupancy Inspection - Codes Residential Ready for Temp CO 8/21/2024 08/21/2024
Miscellaneous Correction
Corrective Action Required
08/13/2024
3733, 3735, 3737 and 3739 SW Clayton Occupancy (3) 3733 Passed for TCO only 3735 Passed for TCO only 3737 Passed for TCO only 3739 Passed for TCO only -All units still needs sod, splash pads and sump pump extensions installed -All units have not been graded for plot plan inspection -All units needs as graded plot plan uploaded Builder sent in a TCO extension form and was expected by the City
Miscellaneous Correction
Corrective Action Required
08/21/2024
3733,3735, 3737 and 3739 SW Clayton Occupancy extension 3733 Passed for TCO only 3735 Passed for TCO only 3737 Passed for TCO only 3739 Passed for TCO only -All units still needs sod, splash pads and sump pump extensions installed Builder sent in a TCO extension form dated 08/19/2024. The City approved the extension. The new TCO will expire on 09/16/2024
Erosion Control Inspection Residential Passed 9/12/2024 09/12/2024
Miscellaneous Correction
Resolved
09/12/2024
Erosion control measures are in place and must be maintained until CofO
Occupancy Inspection - Codes Residential Full C of O 9/16/2024 9/16/2024 09/16/2024
Miscellaneous Correction
Resolved
09/16/2024
3733, 3735, 3737 and 3739 SW Clayton Occupancy (3) 3733 Passed for TCO only 3735 Passed for TCO only 3737 Passed for TCO only 3739 Passed for TCO only -All units still needs sod, splash pads and sump pump extensions installed -All units have not been graded for plot plan inspection -All units needs as graded plot plan uploaded Builder sent in a TCO extension form and was expected by the City
Miscellaneous Correction
Resolved
09/16/2024
3733,3735, 3737 and 3739 SW Clayton Occupancy extension 3733 Passed for TCO only 3735 Passed for TCO only 3737 Passed for TCO only 3739 Passed for TCO only -All units still needs sod, splash pads and sump pump extensions installed Builder sent in a TCO extension form dated 08/19/2024. The City approved the extension. The new TCO will expire on 09/16/2024
Documents & Images
Date Uploaded File Type Document Name
12/14/2023 OS # 48 - PERMIT APP
12/18/2023 Permit Codes Residential Plan Review
12/21/2023 Plot Plan APPROVED PLOT PLAN
12/21/2023 Approved Plans APPROVED PLANS
12/21/2023 Permit Codes Residential Plan Review
12/22/2023 Permit Codes Residential Plan Review
12/22/2023 Approved Plans APPROVED TRUSS PACKAGE
01/02/2024 Approved Plans APPROVED TRUSS LAYOUT
01/02/2024 Permit Codes Residential Plan Review
01/02/2024 Permit DS Building Permit
01/02/2024 Receipt Receipt for transaction:2024-000025
01/10/2024 LOT 48 FINAL 1-10-24
02/06/2024 Letter INSPECTION SUMMARY
02/08/2024 Letter INSPECTION SUMMARY
02/08/2024 M L Crose 3733 3735, 3737, 3739 SW Clayton Pl LSMO Osage Lot 48 Clayton P 2023-6539 3rd Party Footing Inspection Report 1-26-24
02/09/2024 Letter INSPECTION SUMMARY
02/12/2024 Letter INSPECTION SUMMARY
02/13/2024 Letter INSPECTION SUMMARY
02/14/2024 Letter INSPECTION SUMMARY
02/16/2024 Letter INSPECTION SUMMARY
02/16/2024 Letter INSPECTION SUMMARY
02/16/2024 Letter INSPECTION SUMMARY
02/27/2024 48 OSAGE - EMERALD - 231220
03/21/2024 Letter INSPECTION SUMMARY
04/11/2024 Letter INSPECTION SUMMARY
04/11/2024 48 OSAGE - EMERALD - 240411
04/12/2024 LOT 48 FINAL 1-10-24
04/15/2024 Letter INSPECTION SUMMARY
04/15/2024 Letter INSPECTION SUMMARY
04/15/2024 Letter INSPECTION SUMMARY
04/15/2024 Letter INSPECTION SUMMARY
04/16/2024 Plot Plan 4-16-24 PLOT PLAN
04/16/2024 Approved Plans 4-16-24 APPROVED PLANS
04/16/2024 Engineer Report/Study OS 48 Roof truss repair
04/18/2024 Letter INSPECTION SUMMARY
04/18/2024 Letter INSPECTION SUMMARY
04/19/2024 Letter INSPECTION SUMMARY
04/19/2024 Letter INSPECTION SUMMARY
04/23/2024 Letter INSPECTION SUMMARY
04/23/2024 Letter INSPECTION SUMMARY
04/23/2024 OS 48 truss repair
04/25/2024 Letter Stop Work Order
04/25/2024 Letter Stop Work Order
04/25/2024 Letter INSPECTION SUMMARY
05/01/2024 Letter INSPECTION SUMMARY
05/10/2024 Letter INSPECTION SUMMARY
05/10/2024 Letter INSPECTION SUMMARY
05/17/2024 Letter INSPECTION SUMMARY
05/17/2024 Letter INSPECTION SUMMARY
05/17/2024 Letter INSPECTION SUMMARY
05/17/2024 Letter INSPECTION SUMMARY
05/17/2024 Letter INSPECTION SUMMARY
05/17/2024 Letter INSPECTION SUMMARY
06/12/2024 Letter INSPECTION SUMMARY
06/13/2024 Letter INSPECTION SUMMARY
06/13/2024 Letter INSPECTION SUMMARY
06/13/2024 Letter INSPECTION SUMMARY
06/14/2024 Receipt Receipt for transaction:2024-004756
06/17/2024 Letter INSPECTION SUMMARY
06/17/2024 Letter INSPECTION SUMMARY
06/17/2024 Letter INSPECTION SUMMARY
06/18/2024 Letter INSPECTION SUMMARY
06/19/2024 Letter INSPECTION SUMMARY
06/21/2024 Certificate/License Codes Temporary Certificate of Occupancy
06/21/2024 Receipt Receipt for transaction:2024-005000
06/21/2024 Letter INSPECTION SUMMARY
06/21/2024 Receipt Receipt for transaction:2024-005019
06/24/2024 Letter INSPECTION SUMMARY
06/25/2024 Letter INSPECTION SUMMARY
06/25/2024 Receipt Receipt for transaction:2024-005130
06/25/2024 Letter INSPECTION SUMMARY
06/25/2024 Certificate/License Codes Temporary Certificate of Occupancy
06/25/2024 Receipt Receipt for transaction:2024-005158
07/26/2024 Letter Codes 10 Day Letter
07/29/2024 OS #481 - TCO Extension Request Form
07/29/2024 OS #482 - TCO Extension Request Form
07/29/2024 OS #483 - TCO Extension Request Form
07/29/2024 OS #484 - TCO Extension Request Form
08/13/2024 Letter INSPECTION SUMMARY
08/13/2024 Letter INSPECTION SUMMARY
08/13/2024 Letter Codes 10 Day Letter
08/13/2024 Letter INSPECTION SUMMARY
08/20/2024 Plot Plan APPROVED AS BUILT PLOT PLAN
08/21/2024 Letter INSPECTION SUMMARY
08/21/2024 Letter INSPECTION SUMMARY
08/21/2024 Letter INSPECTION SUMMARY
08/22/2024 OS 48 TCOExtension Request Form
08/22/2024 Certificate/License Codes Temporary Certificate of Occupancy
08/22/2024 Certificate/License Codes Temporary Certificate of Occupancy
08/22/2024 Receipt Receipt for transaction:2024-007098
09/12/2024 Letter INSPECTION SUMMARY
09/16/2024 Letter Field Certificate of Occupancy
09/16/2024 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home