Summary
PRRES20224156
Building Permit - Residential
Issued
MILLIGAN TYLER & ERIN
NEW SINGLE FAMILY
NEW HOUSE - SUSPENDED SLAB - ENG FLOOR SYSTEM (DEF) - ENG ROOF SYSTEM (DEF) - TILE ROOF - 600 AMP SERVICE
08/26/2022
11/17/2022
05/14/2023
Locations
Contacts
STARR HOMES LLC, Address:7555 W 160TH ST, Phone:(913) 663-4548  
MILLIGAN TYLER & ERIN, Address:1600 NE DALTONS RIDGE DR  
Thomas Freeman, Address:7555 W 160th St, Phone:(913) 245-9336  
Crown Electric, Address:1213 SE 11th Ter, Phone:(816) 272-5379  
United Heating & Cooling, Address:301 Duck Rd, Phone:(816) 761-5262  
Century Plumbing, Address:14001 Century Ln, Phone:(816) 765-6066  
MILLIGAN TYLER & ERIN, Address:1600 NE DALTONS RIDGE DR  
TFREEMAN@STARRHOMES.NET  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sanitary Sewer Development Fee $1,384.00 $1,384.00 Paid 11/17/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 11/17/2022
7232302-Residential License Tax Fee $1,022.72 $1,022.72 Paid 11/17/2022
8331401-Water Tap Fee $3,730.00 $3,730.00 Paid 11/17/2022
8350015-Water Meter Fee $550.50 $550.50 Paid 11/17/2022
9110078-Valuation Fee New Single Family $5,702.38 $5,702.38 Paid 11/17/2022
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 11/25/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Plot Plan Inspection Pending
Piers/Caissons Inspection - Residential Pending
Sewer Service Inspection - R Pending
Occupancy Inspection - Codes Residential Pending
Footing Inspection - Residential Pending
Misc
Corrective Action Required
03/01/2023
-Footing- ok to pour **Pool bath and storage deleted **detached garage inspected by engineer
Foundation Inspection - Residential Pending
Misc
Corrective Action Required
03/27/2023
Provide engineer detail for the foundation wall. The plan calls for 18"x18' wall, but 12" wall is formed. Reinforcement detail lacking on the plan **3/27-Footing under 18' wall must be resolved first before the foundation wall inspection
Driveway Inspection Pending
Misc
Informational
12/05/2024
2-26-24 NS Site visited no activity as of right now.
All Rough Inspection - Residential Pending
Misc
Corrective Action Required
12/30/2024
-Gas piping union fitting cannot be in concealed space **Make this accessible -Complete installing feeder to detached garage panel -Fb detached garage wall vertically with 3/4” sheathing or other approved material **OK TO ROCK HOUSE
Erosion Control Inspection Residential Pending
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
12/30/2024
EROSION CONTROL IN COMPLIANCE.
Footing Inspection - Residential Not Ready 2/27/2023 (1:00) 2/27/2023 02/27/2023
Misc
Corrective Action Required
02/27/2023
**2/27/23-Inspection denied. Erosion control shall be installed per requirement within two business days and before scheduling an inspection. Failure to install erosion control will result in a stop-work order
Erosion Control Inspection Residential Failed 2/27/2023 02/27/2023
DCM5 ESC INSP DENIED
Corrective Action Required
02/27/2023
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION.
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
02/27/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Footing Inspection - Residential Partial 2/28/2023 (1:00) 2/28/2023 02/28/2023
Misc
Corrective Action Required
02/27/2023
-Footing on the west side of west stair- ok to pour **detached garage inspected by engineer
Footing Inspection - Residential Partial 3/1/2023 (1:00) 3/1/2023 03/01/2023
Misc
Corrective Action Required
02/28/2023
-Footing- ok to pour **Pool bath and storage deleted **detached garage inspected by engineer
Foundation Inspection - Residential Partial 3/6/2023 03/06/2023
Misc
Corrective Action Required
03/06/2023
Partial, foundation forms around basket ball court not complete
Foundation Inspection - Residential Failed 3/22/2023 (9:00) 3/22/2023 03/22/2023
Misc
Corrective Action Required
03/06/2023
Provide engineer detail for the foundation wall. The plan calls for 18"x18' wall, but 12" wall is formed. Reinforcement detail lacking on the plan
Foundation Inspection - Residential Failed 3/27/2023 (10:15) 3/27/2023 03/27/2023
Misc
Corrective Action Required
03/22/2023
Provide engineer detail for the foundation wall. The plan calls for 18"x18' wall, but 12" wall is formed. Reinforcement detail lacking on the plan **3/27-Footing under 18' wall must be resolved first before the foundation wall inspection
Underslab Plumbing Inspection - Residential Failed 5/19/2023 5/19/2023 05/19/2023
Misc
Corrective Action Required
05/19/2023
Vent all basement bathroom shower traps per code. The vent connections shall be above trap weirs
Underslab Plumbing Inspection - Residential Passed 5/24/2023 05/24/2023
Misc
Resolved
05/24/2023
Vent all basement bathroom shower traps per code. The vent connections shall be above trap weirs
Driveway Inspection Partial 2/26/2024 02/26/2024
Misc
Informational
02/26/2024
2-26-24 NS Site visited no activity as of right now.
Water Service Inspection - R Partial 10/23/2024 10/23/2024 10/23/2024
Misc
Corrective Action Required
10/23/2024
- partial, poly ou of foundation 55 foot.
Electrical Service Inspection Passed 11/7/2024 11/07/2024
Informational
11/07/2024
800 amp electrical service approved for release
Gas Service Inspection - Residential Failed 11/7/2024 11/07/2024
Misc
Corrective Action Required
11/07/2024
Not ready
Erosion Control Inspection Residential Partial 11/7/2024 11/07/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
02/27/2023
EROSION CONTROL IN COMPLIANCE.
All Rough Inspection - Residential Partial 11/7/2024 11/7/2024 11/07/2024
Misc
Corrective Action Required
11/07/2024
Inspection not completed
All Rough Inspection - Residential Failed 11/8/2024 11/8/2024 11/08/2024
Misc
Corrective Action Required
11/07/2024
Inspection not completed
Water Service Inspection - R Passed 11/12/2024 11/12/2024 11/12/2024
Misc
Resolved
11/12/2024
- partial, poly ou of foundation 55 foot.
All Rough Inspection - Residential Failed 11/12/2024 11/12/2024 11/12/2024
Misc
Corrective Action Required
11/08/2024
-Submit engineer approval for foundation wall -Anchor garage sill plate 3.5”-12” from sill plates breaks -Garage exterior wall sheathing not nailed to sill plates -Provide full support for truss girder above garage -Provide two 1/2” anchors at each garage PFH wall -Missing THJA26 hanger at CJ03 -Tie down GT D07 and adjacent trusses E12 and D08 -Fb half bathroom wall from roof -Parallel electrical inside return air space at Prep rm -Fb penetration of prep/pantry/kitchen wall plates -Tie down trusses above dining rm -Support plumbing at max ten ft vertically -Protect dryer duct at Erin’s WIC -Provide engineer repair for damaged truss above Erin’s WIC -Fb dead space at corner of Erin’s WIC from both roof and space below -Anchor sill plates per code at Sloan’s area -Strap top plate at south garage where notched more than 60% -Install tension straps for south garage PFH walls per plan -Fb penetrations of top plates at foyer -Secure wiring in truss space per NEC 334.30 -Provide 10 ft vertical fire-blocking in sport/gym space; fb sport closet both vertical and at ceiling level; fb elevator wall from floor space -Fb golf simulation room wall per code; draft stop ceiling space into equal spaces of no more than 1000 square ft -Engineer address rear exterior wall at game room -Protect plumbing at lower level kitchen wall -Provide two lag screws at each end of deck ledger board -Gas piping union fitting cannot be in concealed space -Fb basement fireplace space from ceiling space; fb plumbing space in Sloan’s closet; fb all basement wall space from ceiling space throughout -Provide minimum clearance from basement fireplace flue to combustible materials -Wall top plates and studs cut off in Sloan’s future room -Submit revised plan to city
Driveway Inspection Partial 12/5/2024 12/05/2024
Misc
Informational
02/26/2024
2-26-24 NS Site visited no activity as of right now.
Erosion Control Inspection Residential Partial 12/13/2024 12/13/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
11/07/2024
EROSION CONTROL IN COMPLIANCE.
All Rough Inspection - Residential Failed 12/13/2024 12/13/2024 12/13/2024
Misc
Corrective Action Required
11/12/2024
-Fb half bathroom wall from roof -Protect plumbing at pantry wall -Fb sport closet both vertical and at ceiling level; fb elevator wall from floor space -Draft stop ceiling space into equal spaces of no more than 1000 square ft -Gas piping union fitting cannot be in concealed space **Make this accessible -Fb basement guest bedroom&bathroom wall space from ceiling space -Complete installing feeder to detached garage panel -Fb detached garage wall vertically with 3/4” sheathing or other approved material **OK TO INSULATE
Gas Service Inspection - Residential Failed 12/13/2024 12/13/2024
Misc
Corrective Action Required
11/07/2024
Not ready. Gauge defective
Gas Service Inspection - Residential Passed 12/30/2024 12/30/2024
Misc
Resolved
12/30/2024
Not ready. Gauge defective
All Rough Inspection - Residential Partial 12/30/2024 12/30/2024 12/30/2024
Misc
Corrective Action Required
12/13/2024
-Gas piping union fitting cannot be in concealed space **Make this accessible -Complete installing feeder to detached garage panel -Fb detached garage wall vertically with 3/4” sheathing or other approved material **OK TO ROCK HOUSE
Erosion Control Inspection Residential Partial 12/30/2024 12/30/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
12/13/2024
EROSION CONTROL IN COMPLIANCE.
Documents & Images
Date Uploaded File Type Document Name
08/26/2022 Milligan Eng plot plan 8-10-22
08/30/2022 Application Form excise tax
08/30/2022 Application Form APPLICATION
08/31/2022 Permit Codes Residential Plan Review
09/19/2022 Approved Plans APPROVED PLANS
09/19/2022 Permit Codes Residential Plan Review
11/04/2022 Permit Codes Residential Plan Review
11/15/2022 Permit Codes Residential Plan Review
11/17/2022 Plot Plan approved plot plan
11/17/2022 Permit Codes Residential Plan Review
11/17/2022 Permit DS Building Permit
11/17/2022 Receipt Receipt for transaction:2022-009010
02/27/2023 Letter INSPECTION SUMMARY
02/27/2023 Letter INSPECTION SUMMARY
02/28/2023 Letter INSPECTION SUMMARY
03/01/2023 Letter INSPECTION SUMMARY
03/06/2023 Letter INSPECTION SUMMARY
03/07/2023 Engineer Report/Study DW PIER INSPECTION LETTER Milligan Residence Lot 3A and 4E 512 NE Promised View Dr 2-8-23
03/22/2023 Letter INSPECTION SUMMARY
03/27/2023 Letter INSPECTION SUMMARY
03/31/2023 Engineer Report/Study DW FOOTING ALTERNATE
05/19/2023 Letter INSPECTION SUMMARY
05/24/2023 Letter INSPECTION SUMMARY
08/24/2023 Milligan Rev Eng 8-24-2023
08/24/2023 Milligan Truss & I-Joist Layout Stamped 7-13-2023
08/24/2023 Milligan Roof Seals 6-6-2023
08/24/2023 Milligan Floor Seals 6-6-023
08/24/2023 Approved Plans APPROVED TRUSS PACKAGE
08/24/2023 Approved Plans APPROVED TRUSS LAYOUT
08/24/2023 Approved Plans approved plans
08/24/2023 Approved Plans APPROVED FLOOR JOIST PACKAGE
10/18/2023 Milligan 3rd Party Garage Portal Insp
02/26/2024 Letter INSPECTION SUMMARY
10/11/2024 Letter Codes 180 Day Letter
10/23/2024 Letter INSPECTION SUMMARY
11/07/2024 Letter INSPECTION SUMMARY
11/07/2024 Letter INSPECTION SUMMARY
11/07/2024 Letter INSPECTION SUMMARY
11/07/2024 Letter INSPECTION SUMMARY
11/08/2024 Letter INSPECTION SUMMARY
11/12/2024 Letter INSPECTION SUMMARY
11/12/2024 Engineer Report/Study Engineering Letter
11/12/2024 Letter INSPECTION SUMMARY
11/14/2024 Application Form EXTENSION FORM
11/25/2024 Receipt Receipt for transaction:2024-009133
11/27/2024 Engineer Report/Study ENGINEER FRAMING INSPECTION LETTER
11/27/2024 Engineer Report/Study TRUSS REPAIR LETTER
11/27/2024 3RD Party Insp Report THIRD PARTY FOUNDATION LETTER
12/05/2024 Letter INSPECTION SUMMARY
12/13/2024 Letter INSPECTION SUMMARY
12/13/2024 Letter INSPECTION SUMMARY
12/13/2024 Letter INSPECTION SUMMARY
12/30/2024 Letter INSPECTION SUMMARY
12/30/2024 Letter INSPECTION SUMMARY
12/30/2024 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home