Permit Application Status

PRRES20210438


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20210438
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED PATIO TILE ROOF
02/01/2021
02/03/2021
07/31/2021
05/26/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
MIKE@SUMMITHOMESKC.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 02/05/2021 02/03/2021
Kim Brennan
Spot elevations
Corrective Action Required
02/03/2021

Spot elevations and/or drainage flow arrows shall be provided throughout the lot. No drainage flow arrows provided
Basement opening elevations
Corrective Action Required
02/03/2021

Minimum Building Opening Elevation (MBOE) and location on structure must be provided on the plot plan. Missing the MLO's for the right and left rear
Residential Plan Review Approved 02/05/2021 02/03/2021
Kim Brennan
Planning Review (RES) Approved 02/03/2021 02/02/2021
Shannon McGuire
Plot Plan Review Rejected 02/03/2021 02/01/2021
Kim Brennan
Spot elevations
Corrective Action Required
02/01/2021

Spot elevations and/or drainage flow arrows shall be provided throughout the lot. No drainage flow arrows provided
Basement opening elevations
Corrective Action Required
02/01/2021

Minimum Building Opening Elevation (MBOE) and location on structure must be provided on the plot plan. Missing the MLO's for the right and left rear
Residential Plan Review Approved 02/03/2021 02/01/2021
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $986.13 $986.13 Paid 02/03/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 02/03/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 02/03/2021
8331507-Sewer Connection Fee $390.00 $390.00 Paid 02/03/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 02/03/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 02/03/2021
9110080-3rd and Subsequent Inspection Fee (Per Hour) $50.00 $50.00 Paid 12/21/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 4/9/2021 04/09/2021
Misc
Corrective Action Required
04/09/2021
- 3RD PARTY FOOTING BY COLBY SHAW @ RES SIGNED & SEALED BY BRADLEY HUXOL - - UFER LOCATED CENTER OF REAR GARAGE WALL -
Underslab Plumbing Inspection - Residential Passed 5/24/2021 5/24/2021 05/24/2021
All Rough Inspection - Residential Failed 6/22/2021 6/22/2021 06/22/2021
Misc
Corrective Action Required
06/22/2021
-Two rows of 16D sinker nails 3” oc at braced wall panel top plates per plan, see section view of detail -continue 3” OC fastening exterior sheathing to top plate -no truss hold downs visible front covered porch -no covered rear deck
Erosion Control Inspection Residential Failed 6/30/2021 06/30/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
06/30/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE - - MAINTAIN GRAVEL FILTER - - CLEAN STREET -
All Rough Inspection - Residential Failed 8/18/2021 8/18/2021 08/18/2021
Misc
Corrective Action Required
06/22/2021
Maintain silt fence Provide bonding screw and jumper at exterior metallic boxes Install truss screws at proper height and angle at porch to go through both top plates Nail corners and intersecting walls per code Tighten anchor bolts garage Seal holes in rim joist garage Seal bottom plate penetration by device at laundry/garage Bocca plate at bottom plate pex lines in master bath Bocca plate at refrigerator H2.5s at back deck No pier inspection performed Posts not centered on piers Address beam not bearing on posts at covered patio One inch clearance to combustibles required at fireplace vent Missing LIB bed 2 Install sliding door Nail sheathing at sliding door Roof vent covered above great room Nail double joist hanger at stair header Address joist bored less than 2” to bottom of joist at line set Address multiple holes bored-see at basement within 2” of each other at sub panel Fireblock tub trap Truss hangers on J1 trusses at covered patio and dining Nail hanger and provide hanger at J19 trusses bed 3 Hangers at (3) hip trusses in garage Unable to verify braced wall nailing pattern West exterior wall requires one hour fire rating per code
Electrical Service Inspection Passed 8/18/2021 8/18/2021 08/18/2021
Gas Service Inspection - Residential Passed 8/18/2021 8/18/2021 08/18/2021
All Rough Inspection - Residential Failed 9/15/2021 9/15/2021 09/15/2021
Misc
Corrective Action Required
08/18/2021
-Maintain silt fence-NOT DONE -Provide bonding screw and jumper at exterior metallic boxes-NOT DONE -Install truss screws at proper height and angle at porch to go through both top plates -Nail corners and intersecting walls per code-NOT DONE -Tighten anchor bolts garage-NOT DONE -No pier inspection performed-DRILLED PIERS NOT REFERENCED ON FOOTING REPORT -Posts not centered on piers-ADDRESS BEARING WITH ENGINEER OR RE PIER -Install sliding door -Nail sheathing at sliding door -Roof vent covered above great room- NOT ADDRESSED -Nail double joist hanger at stair header-NAIL HANGER -Address joist bored less than 2” to bottom of joist at line set-NOT DONE -Unable to verify braced wall nailing pattern -West exterior wall requires one hour fire rating per code- PYRO GAURED NEEDS TO BE INSTALLED ALL THE WAY TO THE TOP PLATE AND NAILED PER CODE
Sewer Service Inspection - R Passed 9/16/2021 (8:45) 9/16/2021 09/16/2021
Water Service Inspection - R Passed 9/16/2021 (8:45) 9/16/2021 09/16/2021
All Rough Inspection - Residential Failed 9/22/2021 9/22/2021 09/22/2021
Misc
Corrective Action Required
09/15/2021
**9-22-21 Inspection denied due to lack of erosion control-Maintain gravel filter, silt fence at perimeter and clean trash and debris from site before further inspections -Maintain silt fence-NOT DONE -Provide bonding screw and jumper at exterior metallic boxes-NOT DONE -Install truss screws at proper height and angle at porch to go through both top plates -Nail corners and intersecting walls per code-NOT DONE -Tighten anchor bolts garage-NOT DONE -No pier inspection performed-DRILLED PIERS NOT REFERENCED ON FOOTING REPORT -Posts not centered on piers-ADDRESS BEARING WITH ENGINEER OR RE PIER -Install sliding door -Nail sheathing at sliding door -Roof vent covered above great room- NOT ADDRESSED -Nail double joist hanger at stair header-NAIL HANGER -Address joist bored less than 2” to bottom of joist at line set-NOT DONE -Unable to verify braced wall nailing pattern -West exterior wall requires one hour fire rating per code- PYRO GAURED NEEDS TO BE INSTALLED ALL THE WAY TO THE TOP PLATE AND NAILED PER CODE
Erosion Control Inspection Residential Failed 9/22/2021 9/22/2021 09/22/2021
DCM2 ESC DEFICIENT INSTALLATION
Resolved
09/22/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE - - MAINTAIN GRAVEL FILTER - - CLEAN STREET -
DCM5 ESC INSP DENIED
Corrective Action Required
09/22/2021
**9-22-21 Inspection denied due to lack of erosion control-Maintain gravel filter, silt fence at perimeter and clean trash and debris from site before further inspections REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION.
All Rough Inspection - Residential Failed 9/24/2021 9/24/2021 09/24/2021
Misc
Corrective Action Required
09/22/2021
-Install sliding door -Nail sheathing at sliding door OK TO INSULATE
Driveway Inspection Partial 10/7/2021 10/7/2021 10/07/2021
Misc
Informational
10/07/2021
10-7-21 10:41 AN Forms are in place and aggregate is present and compacted. No sidewalk
Driveway Inspection Passed 10/15/2021 10/15/2021 10/12/2021
Misc
Informational
10/07/2021
10-7-21 10:41 AN Forms are in place and aggregate is present and compacted. No sidewalk
Misc
Informational
10/12/2021
10-12-21 AN driveway looks good and has expansion joints at curb and right of way.no sidewalk
All Rough Inspection - Residential Passed 12/13/2021 12/13/2021 12/13/2021
Misc
Resolved
12/13/2021
Occupancy Inspection - Codes Residential Failed 12/13/2021 12/13/2021 12/13/2021
Miscellaneous Correction
Corrective Action Required
12/13/2021
- provide gutters - Complete final grading and sod - Obtain sprinkler permit and submit back flow certification - Provide splash blocks - Provide secondary lock on back door - Provide outlet outside near a/c compressor - Tighten and break off set screw in water back flow preventer - Cap off pipes in basement (future bathroom ) - Install permanent front door - Submit an as built plot plan( address possible retaining wall off back of house and drainage inlet -
Miscellaneous Correction
Corrective Action Required
12/13/2021
- provide gutters - Complete final grading and sod - Obtain sprinkler permit and submit back flow certification - Provide splash blocks - Provide secondary lock on back door - Provide outlet outside near a/c compressor - Tighten and break off set screw in water back flow preventer - Cap off pipes in basement (future bathroom ) - Install permanent front door - Submit an as built plot plan
Occupancy Inspection - Codes Residential Failed 12/17/2021 12/17/2021 12/17/2021
Miscellaneous Correction
Corrective Action Required
12/13/2021
- provide gutters & downspouts - Complete final grading and sod - Obtain sprinkler permit and submit back flow certification - Provide splash blocks - Submit an as built plot plan( address possible retaining wall off back of house and drainage inlet - - ADDRESS IDENTIFICATION CHARACTERS SHALL CONTRAST WITH THEIR BACKGROUND ( 2018 IRC R319)- - GARAGE STAIRS: AT OPEN RISERS, OPENINGS LOCATED MORE THAN 30" AS MEASURED VERTICALLY, TO THE FLOOR OR GRADE BELOW SHALL NOT PERMIT THE PASSAGE OF A 4" DIAMETER SPHERE ( 2018 IRC R311.7.5.1) - - SUMP SHALL DISCHARGE 36" FROM FOUNDATION WALL - - LAND SEWER TRACER WIRE IN A BOX AT GRADE - - PROVIDE ENGINEERING FOR RETAINING WALL OVER 4' -
Miscellaneous Correction
Corrective Action Required
12/13/2021
- provide gutters - Complete final grading and sod - Obtain sprinkler permit and submit back flow certification - Provide splash blocks - Provide secondary lock on back door - Provide outlet outside near a/c compressor - Tighten and break off set screw in water back flow preventer - Cap off pipes in basement (future bathroom ) - Install permanent front door - Submit an as built plot plan
Occupancy Inspection - Codes Residential Failed 12/20/2021 12/20/2021 12/20/2021
Miscellaneous Correction
Corrective Action Required
12/17/2021
- provide gutters & downspouts - Complete final grading and sod - Obtain sprinkler permit and submit back flow certification - Provide splash blocks - Submit an as built plot plan( address possible retaining wall off back of house and drainage inlet - - GARAGE STAIRS: AT OPEN RISERS, OPENINGS LOCATED MORE THAN 30" AS MEASURED VERTICALLY, TO THE FLOOR OR GRADE BELOW SHALL NOT PERMIT THE PASSAGE OF A 4" DIAMETER SPHERE ( 2018 IRC R311.7.5.1) - - SUMP SHALL DISCHARGE 36" FROM FOUNDATION WALL - - LAND SEWER TRACER WIRE IN A BOX AT GRADE - - PROVIDE ENGINEERING FOR RETAINING WALL OVER 4' -
Miscellaneous Correction
Resolved
12/20/2021
Occupancy Inspection - Codes Residential Temporary C of O 12/21/2021 12/21/2021 12/21/2021
Miscellaneous Correction
Corrective Action Required
12/20/2021
- Complete final grading and sod - Obtain sprinkler permit and submit back flow certification - Provide splash blocks - Submit an as built plot plan( address possible retaining wall off back of house and drainage inlet - SUMP SHALL DISCHARGE 36" FROM FOUNDATION WALL - - LAND SEWER TRACER WIRE IN A BOX AT GRADE - - PROVIDE ENGINEERING FOR RETAINING WALL OVER 4' -
Plot Plan Inspection Failed 3/18/2022 03/18/2022
Miscellaneous Correction
Corrective Action Required
03/18/2022
provide as graded plot plan Provide engineering for retaining wall over 4'
Erosion Control Inspection Residential Failed 3/18/2022 03/18/2022
DCM5 ESC INSP DENIED
Corrective Action Required
09/22/2021
**9-22-21 Inspection denied due to lack of erosion control-Maintain gravel filter, silt fence at perimeter and clean trash and debris from site before further inspections REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION.
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
03/18/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. MAINTAIN SILT FENCE UNTIL SOD COMPLETE
Piers/Caissons Inspection - Residential Passed 3/18/2022 03/18/2022
Misc
Informational
09/24/2021
3RD PARTY BY EVERSTEAD ON FOOTING INSPECTION
Occupancy Inspection - Codes Residential Temporary C of O 3/18/2022 03/18/2022
Miscellaneous Correction
Corrective Action Required
12/21/2021
- Complete final grading and sod - Provide splash blocks - Submit an as built plot plan( address possible retaining wall off back of house and drainage inlet - SUMP SHALL DISCHARGE 36" FROM FOUNDATION WALL - - LAND SEWER TRACER WIRE IN A BOX AT GRADE - - PROVIDE ENGINEERING FOR RETAINING WALL OVER 4' -
Erosion Control Inspection Residential Passed 05/26/2022
DCM5 ESC INSP DENIED
Resolved
05/26/2022
DCM2 ESC DEFICIENT INSTALLATION
Resolved
05/26/2022
Plot Plan Inspection Passed 5/26/2022 05/26/2022
Miscellaneous Correction
Corrective Action Required
03/18/2022
provide as graded plot plan Provide engineering for retaining wall over 4'
Occupancy Inspection - Codes Residential Failed 5/26/2022 5/26/2022 05/26/2022
Miscellaneous Correction
Corrective Action Required
03/18/2022
- Driveway inspection pending
Occupancy Inspection - Codes Residential Full C of O 5/26/2022 05/26/2022
Miscellaneous Correction
Resolved
05/26/2022
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home