Permit Application Status

PRRES20200757


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20200757
Building Permit - Residential
Certificate of Occupancy
HUNT MIDWEST RESIDENTIAL LLC
NEW SINGLE FAMILY
NEW SINGLE FAMILY UNFINISHED BASEMENT COVERED PATIO
03/23/2020
04/08/2020
09/22/2020
02/27/2024
Locations
Contacts
HUNT MIDWEST RESIDENTIAL LLC, Address:8300 NE UNDERGROUND DR  
IQ CONSTRUCTION, Address:P O BOX 6423, Phone:(816) 582-8100  
JENNIFER@IQHOMEBUILDERS.COM  
SAFEHOUSE ELECTRIC COMPANY, Address:P O BOX 1833, Phone:(816) 935-8113  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
FIVE STAR PLUMBING INC, Address:P O BOX 452, Phone:(816) 228-8821  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 03/30/2020 03/30/2020
Steve Conrick
Deck location
Corrective Action Required
03/27/2020

Deck location, with dimensions to property lines must be provided on the plot plan. Clearify covered or uncovered patio
Residential Plan Review Approved 03/31/2020 03/27/2020
Steve Conrick
05 Provide square footage of living area, garage area, unfinished basement
Corrective Action Required
03/27/2020

Provide square footage of living area, garage area, unfinished basement area, etc (IRC Section R304) Clearify if there will be a covered patio or not. If so, provide sqft on plans.
Miscellaneous Correction
Corrective Action Required
03/27/2020

Correct address mispelling on plans
Plot Plan Review Rejected 03/25/2020 03/26/2020
Steve Conrick
Deck location
Corrective Action Required
03/26/2020

Deck location, with dimensions to property lines must be provided on the plot plan. Clearify covered or uncovered patio
Residential Plan Review Rejected 03/26/2020 03/26/2020
Steve Conrick
05 Provide square footage of living area, garage area, unfinished basement
Corrective Action Required
03/26/2020

Provide square footage of living area, garage area, unfinished basement area, etc (IRC Section R304) Clearify if there will be a covered patio or not. If so, provide sqft on plans.
Miscellaneous Correction
Corrective Action Required
03/26/2020

Correct address mispelling on plans
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,164.14 $1,164.14 Paid 04/08/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 04/08/2020
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 04/08/2020
8331507-Sewer Connection Fee $570.00 $570.00 Paid 04/08/2020
8331401-Water Tap Fee $3,477.00 $3,477.00 Paid 04/08/2020
8350015-Water Meter Fee $425.02 $425.02 Paid 04/08/2020
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 12/01/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 5/14/2020 (2:00) 5/14/2020 at 2:16 PM 05/14/2020
Erosion Control Inspection Residential Failed 6/10/2020 06/10/2020
DCM5 ESC INSP DENIED
Corrective Action Required
06/10/2020
- MAINTAIN SILT FENCE -
Underslab Plumbing Inspection - Residential Not Ready 6/10/2020 6/10/2020 06/10/2020
Misc
Corrective Action Required
06/10/2020
- NO UNDERSLAB PLUMBING DONE ONLY A DRAIN TILE -
Piers/Caissons Inspection - Residential Passed 6/10/2020 (9:15) 6/10/2020 06/10/2020
Misc
Informational
06/10/2020
(3) 24 x 36 DECK PIERS
Underslab Plumbing Inspection - Residential Passed 6/11/2020 6/10/2020 06/10/2020
Misc
Resolved
06/10/2020
- NO UNDERSLAB PLUMBING DONE ONLY A DRAIN TILE - RE INSPECT WITH PIERS Michael Harkins 06/10/2020 11:10 AM
All Rough Inspection - Residential Partial 7/30/2020 7/30/2020 07/30/2020
Misc
Informational
07/30/2020
- GARAGE PORTAL FRAMING ONLY HOLD DOWNS NAILED OFF, HEADER NAILING PATTERN APPROVED -
Erosion Control Inspection Residential Failed 8/10/2020 08/10/2020
DCM5 ESC INSP DENIED
Corrective Action Required
06/10/2020
- MAINTAIN SILT FENCE -
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
08/10/2020
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. - MAINTAIN SILT FENCE -
Sewer Service Inspection - R Passed 8/10/2020 (2:30) 8/10/2020 08/10/2020
Water Service Inspection - R Passed 8/12/2020 08/12/2020
Electrical Service Inspection Passed 8/21/2020 8/21/2020 08/21/2020
Gas Piping Inspection - Residential Passed 8/21/2020 08/21/2020
Gas Service Inspection - Residential Passed 8/21/2020 8/21/2020 08/21/2020
Erosion Control Inspection Residential Failed 8/21/2020 08/21/2020
DCM5 ESC INSP DENIED
Corrective Action Required
08/10/2020
- MAINTAIN SILT FENCE -
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
08/10/2020
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. - MAINTAIN SILT FENCE -
Erosion Control Inspection Residential Failed 8/21/2020 08/21/2020
DCM5 ESC INSP DENIED
Corrective Action Required
08/21/2020
- MAINTAIN SILT FENCE -
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
08/21/2020
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. - MAINTAIN SILT FENCE -
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
08/21/2020
EROSION CONTROL REQUIRED. - MAINTAIN SILT FENCE - - MAINTAIN GRAVEL FILTER -
All Rough Inspection - Residential Failed 8/21/2020 8/21/2020 08/21/2020
Misc
Informational
07/30/2020
- GARAGE PORTAL FRAMING ONLY HOLD DOWNS NAILED OFF, HEADER NAILING PATTERN APPROVED -
Misc
Corrective Action Required
08/21/2020
- TIGHTEN ANCHOR BOLTS GARAGE - - provide struts on hip above single car garage per plan - - provide joist hanger at attic access garage - - provide triple 2 x 10s above double garage door per plan - - joist hanger missing garage header off for toilet - - nail siding above 4 windows rear of house & above window well - - provide vertical to horizontal fire blocking soffit & DWV garage - - furr put duct garage for insulation - - address damaged 2 x 12 hip above front door - - master closet ridge plan shows 2 x 12 framed 2 x 8 - - where floor joist run parallel to foundation wall solid block outside 3 joist spaces @ 36” OC. Per plan - - fire block dead space at laundry room - - flash above horizontal trim above dining room window - - boca plates hallway top plate - - boca plates master bath / bed - - flashing & snow blocking bed #2- - nail joist hanger above bed #4 door - - complete vent pipe master water closet - - provide 5 studs under LVL at stairway per plan - - provide anchor bolts SCH 40 columns basement - - missing nail STHD14 garage portal frame -
All Rough Inspection - Residential Failed 8/31/2020 8/31/2020 08/31/2020
Misc
Informational
08/21/2020
- GARAGE PORTAL FRAMING ONLY HOLD DOWNS NAILED OFF, HEADER NAILING PATTERN APPROVED -
Misc
Corrective Action Required
08/21/2020
GENERAL- -Anchor steel columns FRAMING- -Furr duct in garage for insulation. -Provide fire blocking in dead space between upstairs laundry room and bedroom 2 -Missing nail STHD14 garage portal frame PLUMBING- -Complete master bath water closet vent -Provide proper nail plate protection vent top plate penetration upstairs hallway -Provide proper nail plate protection vent top and bottom plate penetration between master bed and master bath OK TO INSULATE DO NOT ROCK RE-INSPECTION REQUIRED
All Rough Inspection - Residential Passed 9/1/2020 9/1/2020 09/01/2020
Misc
Informational
08/31/2020
- GARAGE PORTAL FRAMING ONLY HOLD DOWNS NAILED OFF, HEADER NAILING PATTERN APPROVED - 9/1/2020 OK TO ROCK
Misc
Resolved
09/01/2020
GENERAL- -Anchor steel columns FRAMING- -Furr duct in garage for insulation. -Provide fire blocking in dead space between upstairs laundry room and bedroom 2 -Missing nail STHD14 garage portal frame PLUMBING- -Complete master bath water closet vent -Provide proper nail plate protection vent top plate penetration upstairs hallway -Provide proper nail plate protection vent top and bottom plate penetration between master bed and master bath OK TO INSULATE DO NOT ROCK RE-INSPECTION REQUIRED
Erosion Control Inspection Residential Failed 9/16/2020 09/16/2020
Misc
Corrective Action Required
09/16/2020
-Deficient erosion control installation, Shall be in compliance within two days -Street cleanup required immediately -Remove trash from site -Remove overgrown weeds & vegetation
Driveway Inspection Partial 9/23/2020 (P.M.) 9/23/2020 09/23/2020
Misc
Informational
09/23/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Partial 9/23/2020 9/23/2020 09/23/2020
Misc
Informational
09/23/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 9/30/2020 9/30/2020 10/01/2020
Misc
Informational
09/23/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Partial 9/30/2020 9/30/2020 10/01/2020
Misc
Informational
09/23/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Misc
Informational
10/01/2020
The north section of the sidewalk is poured and in compliance.
Sidewalk Inspection Partial 12/1/2020 (A.M.) 12/1/2020 12/01/2020
Misc
Informational
10/01/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Misc
Informational
10/01/2020
The north section of the sidewalk is poured and in compliance.
Misc
Informational
12/01/2020
PRE POUR INSPECTION The south sidewalk section is formed and there appears to be sufficient compacted aggregate.
Occupancy Inspection - Codes Residential Failed 12/1/2020 12/1/2020 12/01/2020
Misc
Corrective Action Required
12/01/2020
-All outstanding fees must be paid in full -Complete sidewalk installation -Remove trash and construction debris -Provide gutters and downspouts -Downspouts and sump piping to discharge minimum 36 inches from foundation -Provide building address minimum 4“ height 1/2” stroke on contrasting background in illuminated area -Final grade and sod per approved plans -Seal top and sides of exterior lighting exposed to the elements, electric meter enclosure, A/C disconnect and all exterior penetrations -Complete exterior façade -Remove excavation spoils from site -Provide siding glass door hardware and secondary locking device -Both dwelling/garage separation doors required to self close and self latch -Handrail at garage stairs required to extend over lowest riser and terminate into post -AFCI protection required for 120V 15 & 20A laundry and kitchen circuits -Switch plate cover at furnace -Complete ceiling fan installation, master bed -Complete lighting fixture installation, master toilet room -Complete guard rail installation at stairs -Guard rail required were grade below exceeds 30 inches, front stoop
Occupancy Inspection - Codes Residential Failed 12/2/2020 12/2/2020 12/02/2020
Misc
Corrective Action Required
12/01/2020
-Only partial approval of sidewalk inspection, contact Development Services to resolve this issue -Remove trash and construction debris -Provide gutters and downspouts -Downspouts and sump piping to discharge minimum 36 inches from foundation -Final grade and sod per approved plot -Remove excavation spoils from site -Switch plate cover at furnace
Occupancy Inspection - Codes Residential Temporary C of O 12/2/2020 12/02/2020
Misc
Corrective Action Required
12/02/2020
-Only partial approval of sidewalk inspection, contact Development Services to resolve this issue -Remove trash and construction debris -Provide gutters and downspouts -Downspouts and sump piping to discharge minimum 36 inches from foundation -Final grade and sod per approved plot -Remove excavation spoils from site TCO VALID THROUGH 1/2/2021
Sidewalk Inspection Failed 12/8/2020 12/8/2020 12/09/2020
Misc
Informational
12/01/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Misc
Informational
12/01/2020
The north section of the sidewalk is poured and in compliance.
Misc
Informational
12/01/2020
PRE POUR INSPECTION The south sidewalk section is formed and there appears to be sufficient compacted aggregate.
Misc
Corrective Action Required
12/09/2020
POST POUR INSPECTION FAILED. The cross slope of the sidewalk is in compliance however there are two cracked sidewalk panels that need correction before acceptance.
Occupancy Inspection - Codes Residential Failed 5/18/2021 05/18/2021
Misc
Corrective Action Required
12/02/2020
-Only partial approval of sidewalk inspection, contact Development Services to resolve this issue -Remove trash and construction debris -Provide gutters and downspouts -Downspouts and sump piping to discharge minimum 36 inches from foundation -Final grade and sod per approved plot -Remove excavation spoils from site TCO VALID THROUGH 1/2/2021
Misc
Corrective Action Required
05/18/2021
The temporary certificate of occupancy has expired at this address. If remaining correction items are complete please schedule an occupancy inspection. If remaining correction items are not complete a permit extension request must be submitted in writing with the expected date of completion.
Documents & Images
Date Uploaded File Type Document Name
03/23/2020 2517 SW River Trail Rd - Permit Application
03/24/2020 2517 SW River Trail Rd - Signed Plot Plan
03/24/2020 2517 SW River Trail Rd - OAKMONT - GL - Sealed Plans
03/26/2020 2517 SW River Trail Rd - LSMO Excise Tax
03/26/2020 Letter Codes Residential Plan Review
03/26/2020 2517 SW River Trail Rd - Revised - OAKMONT - GL - Sealed Plans
03/30/2020 Plot Plan LOT 670 CITY
04/03/2020 EGC670 Spec - Sealed Plans (April 3, 2020)
04/03/2020 Plans APPROVED EGC670 Spec - Sealed Plans (April 3, 2020)
04/08/2020 Letter DS Building Permit
05/14/2020 Letter INSPECTION SUMMARY
06/10/2020 Letter INSPECTION SUMMARY
06/10/2020 Letter INSPECTION SUMMARY
06/10/2020 Letter INSPECTION SUMMARY
06/10/2020 Letter INSPECTION SUMMARY
07/30/2020 Letter INSPECTION SUMMARY
08/10/2020 Letter INSPECTION SUMMARY
08/10/2020 Letter INSPECTION SUMMARY
08/12/2020 Letter INSPECTION SUMMARY
08/12/2020 Letter Codes Residential Plan Review
08/21/2020 Letter INSPECTION SUMMARY
08/21/2020 Letter INSPECTION SUMMARY
08/21/2020 Letter INSPECTION SUMMARY
08/21/2020 Letter INSPECTION SUMMARY
08/21/2020 Letter INSPECTION SUMMARY
08/21/2020 Letter INSPECTION SUMMARY
08/28/2020 Approved Plans Revised Drawings
08/31/2020 Letter INSPECTION SUMMARY
09/01/2020 Letter INSPECTION SUMMARY
09/16/2020 Letter INSPECTION SUMMARY
09/23/2020 Letter INSPECTION SUMMARY
09/23/2020 Letter INSPECTION SUMMARY
10/01/2020 Letter INSPECTION SUMMARY
10/01/2020 Letter INSPECTION SUMMARY
12/01/2020 Letter INSPECTION SUMMARY
12/01/2020 Letter INSPECTION SUMMARY
12/01/2020 Receipt Receipt for transaction:2020-007781
12/02/2020 Letter Codes Residential Plan Review
12/02/2020 Letter INSPECTION SUMMARY
12/02/2020 Letter Codes Temporary Certificate of Occupancy
12/09/2020 Letter INSPECTION SUMMARY
12/09/2020 Damaged sidewalk panels..jpg
05/18/2021 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home