NEW DUPLEX
NEW TOWNHOME. UNFINISHED BASEMENT. ROOF TRUSSES. STOP WORK ORDER generated on 05/08/2025 12:00 AM by username 'Jamie Simerly'. STOP WORK ORDER removed on 05/13/2025 12:00 AM by username 'Jamie Simerly'.
05/30/2024
06/21/2024
12/08/2024
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
TAYLOR@CLOVERANDHIVE.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee for New Duplex $2,994.44 $2,994.44 Paid 06/21/2024
Water Tap Fee $7,520.00 $7,520.00 Paid 06/21/2024
Water Meter Fee $1,360.92 $1,360.92 Paid 06/21/2024
Sanitary Sewer Development Fee $4,318.00 $4,318.00 Paid 06/21/2024
Right of Way Permit Fee $85.00 $85.00 Paid 06/21/2024
Residential Excise Tax Fee $1,240.32 $1,240.32 Paid 06/21/2024
Outstanding Fees Amount Paid Owing Date Paid
Not Ready Inspection Fee $75.00 $0.00 $75.00 Not Paid
Not Ready Inspection Fee $75.00 $0.00 $75.00 Not Paid
Not Ready Inspection Fee $75.00 $0.00 $75.00 Not Paid
Not Ready Inspection Fee $75.00 $0.00 $75.00 Not Paid
Not Ready Inspection Fee $75.00 $0.00 $75.00 Not Paid
Temporary Occupancy Fee $50.00 $0.00 $50.00 Not Paid


$425.00    Add Fees to My Cart
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Sidewalk Inspection Pending
Misc
Informational
04/04/2025
3-24-25 Dustin Asw has been formed and compacted. And slopes are in compliance. Approved to pour 4-4-25 Dustin A, sw has been poured to city specs, slopes are in compliance.. There are 2 valves that are missing top hats and will need to be cut to grade before closing this out
Occupancy Inspection - Codes Residential Pending
Misc
Corrective Action Required
04/04/2025
-Sidewalk and driveway not approved on record -As-graded plot plan is required -Final grade, sod, downspout and sump pump extension -Seal exterior wall penetrations; seal above meter, AC disconnect, seal exterior lights, etc 3711: -Provide sewer tracer wire port at grade -Provide bottom deck stair landing; shim gap under deck beam at post support( deck stairs blocked for TCO) 3713: -Provide bottom deck stair landing; shim gap under deck beam at post support
Erosion Control Inspection Residential Pending
Miscellaneous Correction
Informational
05/13/2025
Erosion control is in place and must be properly maintained until CofO
Sidewalk Inspection Pending
Plot Plan Inspection Pending
Misc
Corrective Action Required
06/04/2025
Need sod and splash blocks
Erosion Control Inspection Residential Failed 9/18/2024 09/18/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
09/18/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. Gravel needs to be spread from the foundation to the street
Footing Inspection - Residential Failed 9/18/2024 09/18/2024
Miscellaneous Correction
Corrective Action Required
09/18/2024
No address is post on property Erosion control needs to pass Both items need to be addressed before scheduling any inspections KBEARD 09/18/24. 9:44am
Footing Inspection - Residential Passed 9/19/2024 09/19/2024
Miscellaneous Correction
Resolved
09/19/2024
No address is post on property Erosion control needs to pass Both items need to be addressed before scheduling any inspections KBEARD 09/18/24. 9:44am
Miscellaneous Correction
Informational
09/19/2024
Footing passed by a third party. Exterior piers were not mentioned in the footing report
Sewer Service Inspection - R Passed 9/19/2024 9/19/2024 09/19/2024
Water Service Inspection - R Passed 9/20/2024 9/20/2024 09/20/2024
Erosion Control Inspection Residential Partial 9/25/2024 09/25/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
09/25/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. Gravel needs to be spread from the foundation to the street
Miscellaneous Correction
Informational
09/25/2024
Full erosion control measures are in place and must be maintained until CofO
Underslab Plumbing Inspection - Residential Passed 9/25/2024 9/25/2024 09/25/2024
Erosion Control Inspection Residential Failed 11/1/2024 11/01/2024
Miscellaneous Correction
Resolved
11/01/2024
Full erosion control measures are in place and must be maintained until CofO
Miscellaneous Correction
Corrective Action Required
11/01/2024
Repair or replace damaged or missing straw waddle along properties north side that is damaged or missing Full erosion control measures must be in place and properly maintained until CofO
All Rough Inspection - Residential Failed 12/5/2024 12/5/2024 12/05/2024
Miscellaneous Correction
Corrective Action Required
12/05/2024
Exterior garage PFH sheeting failed. Fasteners do not attach to both top plates This was a partial inspection for exterior portal sheeting only
All Rough Inspection - Residential Failed 12/16/2024 12/16/2024 12/16/2024
Miscellaneous Correction
Corrective Action Required
12/05/2024
Exterior garage PFH sheeting failed. Fasteners do not attach to both top plates This was a partial inspection for exterior portal sheeting only
Misc
Corrective Action Required
12/16/2024
12/16/24 -Inspection denied. Provide effective erosion control at front, side and back of lot. Clean debris from streets and protect storm inlets
Erosion Control Inspection Residential Failed 12/16/2024 12/16/2024 12/16/2024
Miscellaneous Correction
Resolved
12/16/2024
Repair or replace damaged or missing straw waddle along properties north side that is damaged or missing Full erosion control measures must be in place and properly maintained until CofO
DCM5 ESC INSP DENIED
Corrective Action Required
12/16/2024
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. 12/16/24 -Inspection denied. Provide effective erosion control at front, side and back of lot. Clean debris from streets and protect storm inlets
All Rough Inspection - Residential Failed 12/23/2024 12/23/2024 12/23/2024
Miscellaneous Correction
Resolved
12/23/2024
Exterior garage PFH sheeting failed. Fasteners do not attach to both top plates This was a partial inspection for exterior portal sheeting only
Misc
Resolved
12/23/2024
12/16/24 -Inspection denied. Provide effective erosion control at front, side and back of lot. Clean debris from streets and protect storm inlets
Miscellaneous Correction
Informational
12/23/2024
Exterior sheathing passed and is okay to cover This is a partial pass only
Erosion Control Inspection Residential Partial 12/23/2024 12/23/2024
DCM5 ESC INSP DENIED
Resolved
12/23/2024
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. 12/16/24 -Inspection denied. Provide effective erosion control at front, side and back of lot. Clean debris from streets and protect storm inlets
Miscellaneous Correction
Informational
12/23/2024
Erosion control is in place and must be properly maintained until CofO
Erosion Control Inspection Residential Partial 12/30/2024 12/30/2024
Miscellaneous Correction
Informational
12/23/2024
Erosion control is in place and must be properly maintained until CofO
Electrical Service Inspection Passed 12/30/2024 12/30/2024 12/30/2024
Gas Service Inspection - Residential Passed 12/30/2024 12/30/2024 12/30/2024
Rated Assembly Inspection Failed 12/30/2024 12/30/2024 12/30/2024
Miscellaneous Correction
Corrective Action Required
12/30/2024
3713 Seal around bonding wire at demising wall Seal all the way around service cable at demising wall Provide UL listing for green board used in bedroom 1 and above bedroom 1 There is a gap in the demising wall above bedroom 1’s ceiling behind a vertical 2x4 3711 Seal all the way around service cable at demising wall Provide UL listing for green board used in bedroom 1 and above bedroom 1 Demising wall does not meet at the west wall in attic space above bedroom 1
All Rough Inspection - Residential Not Ready 12/30/2024 12/30/2024 12/30/2024
Miscellaneous Correction
Informational
12/23/2024
Exterior sheathing passed and is okay to cover This is a partial pass only
Miscellaneous Correction
Corrective Action Required
12/30/2024
All rough inspection is not ready. Bedroom 1’s shower enclosure is not installed in unit 3711 Walk your property before scheduling any inspections 12/30/2024 KBEARD 8:45am
All Rough Inspection - Residential Not Ready 1/2/2025 1/2/2025 01/02/2025
Miscellaneous Correction
Informational
12/30/2024
Exterior sheathing passed and is okay to cover This is a partial pass only
Miscellaneous Correction
Corrective Action Required
12/30/2024
All rough inspection is not ready. Bedroom 1’s shower enclosure is not installed in unit 3711 Walk your property before scheduling any inspections 12/30/2024 KBEARD 8:45am
Miscellaneous Correction
Corrective Action Required
01/02/2025
3711/3713 SW Knoxville. All rough (2) 3711 Have engineers letter for exterior foundation wall broken out at anchor bolts Nail garage SW corner to code Fire block top of stud cavity for the HVAC system in the powder bathroom to garage Install missing joist hangers in floor joist above kitchen and great room NE corner of the great room has a wedge in it and will not allow the corner to be properly secured All exterior wall headers require 4 nails on each side to be installed Nail exterior dining room corner to code Strap top plate in bathroom 1 at plumbing vent line where it is bored more than 50 percent Snow blocking for gable flashing above entry is not installed H 2.5 truss tie downs are not installed according to page a6.0 at bearing wall Fire block top plate in bedroom 2 to hallway BATHROOM SHOWER ENCLOSURE IS STILL NOT INSTALLED Unit is not ready for inspection This is the second time an all rough has been scheduled and bathroom 1 shower enclosure is not completed WALK YOUR PROPERTY before scheduling inspections 01/02/2025. KBEARD This is not a complete list
Rated Assembly Inspection Failed 1/2/2025 1/2/2025 01/02/2025
Miscellaneous Correction
Corrective Action Required
12/30/2024
3713 Provide UL listing for green board used in bedroom 1 and above bedroom 1 There is a gap in the demising wall above bedroom 1’s ceiling behind a vertical 2x4 3711 Provide UL listing for green board used in bedroom 1 and above bedroom 1 Demising wall does not meet at the west wall in attic space above bedroom 1
Rated Assembly Inspection Passed 1/21/2025 1/21/2025 01/21/2025
Miscellaneous Correction
Resolved
01/21/2025
3713 Provide UL listing for green board used in bedroom 1 and above bedroom 1 There is a gap in the demising wall above bedroom 1’s ceiling behind a vertical 2x4 3711 Provide UL listing for green board used in bedroom 1 and above bedroom 1 Demising wall does not meet at the west wall in attic space above bedroom 1
All Rough Inspection - Residential Failed 1/21/2025 1/21/2025 01/21/2025
Miscellaneous Correction
Informational
01/02/2025
Exterior sheathing passed and is okay to cover This is a partial pass only
Miscellaneous Correction
Resolved
01/21/2025
All rough inspection is not ready. Bedroom 1’s shower enclosure is not installed in unit 3711 Walk your property before scheduling any inspections 12/30/2024 KBEARD 8:45am
Miscellaneous Correction
Corrective Action Required
01/02/2025
3711/3713 SW Knoxville. All rough (2) 3711 - Strap top plate in bathroom 1 at plumbing vent line where it is bored more than 50 percent - H 2.5 truss tie downs are not installed according to page a6.0 at bearing wall - Fire block top plate in bedroom 2 to hallway 3713 - Strap top plate at bathroom 1 @ DWV of load bearing wall - Strap top plate at bathroom 2 @ DWV of load bearing wall
All Rough Inspection - Residential Not Ready 1/23/2025 1/23/2025 01/23/2025
Miscellaneous Correction
Informational
01/21/2025
Exterior sheathing passed and is okay to cover This is a partial pass only
Miscellaneous Correction
Resolved
01/23/2025
3711/3713 SW Knoxville. All rough (2) 3711 - Strap top plate in bathroom 1 at plumbing vent line where it is bored more than 50 percent - H 2.5 truss tie downs are not installed according to page a6.0 at bearing wall - Fire block top plate in bedroom 2 to hallway 3713 - Strap top plate at bathroom 1 @ DWV of load bearing wall - Strap top plate at bathroom 2 @ DWV of load bearing wall
Miscellaneous Correction
Corrective Action Required
01/23/2025
3711 - Strap top plate in bathroom 1 at plumbing vent line where it is bored more than 50 percent - H 2.5 truss tie downs are not installed according to page 6.0 at bearing wall 3713 - Strap top plate at bathroom 1 @ DWV of load bearing wall - Strap top plate at bathroom 2 @ DWV of load bearing wall - H 2.5 truss tie downs are not installed according to page 6.0 at bearing wall No improvements were made since last inspection Walk your property before scheduling your inspections Not ready for inspection
All Rough Inspection - Residential Not Ready 1/24/2025 1/24/2025 01/24/2025
Miscellaneous Correction
Resolved
01/24/2025
Exterior sheathing passed and is okay to cover This is a partial pass only
Miscellaneous Correction
Resolved
01/24/2025
3711 - Strap top plate in bathroom 1 at plumbing vent line where it is bored more than 50 percent - H 2.5 truss tie downs are not installed according to page 6.0 at bearing wall 3713 - Strap top plate at bathroom 1 @ DWV of load bearing wall - Strap top plate at bathroom 2 @ DWV of load bearing wall - H 2.5 truss tie downs are not installed according to page 6.0 at bearing wall No improvements were made since last inspection Walk your property before scheduling your inspections Not ready for inspection
Miscellaneous Correction
Corrective Action Required
01/24/2025
3711 - Strap top plate in bathroom 1 at plumbing vent line where it is bored more than 50 percent - H 2.5 truss tie downs are not installed according to page 6.0 at bearing wall 3713 - Strap top plate at bathroom 1 @ DWV of load bearing wall - Strap top plate at bathroom 2 @ DWV of load bearing wall - H 2.5 truss tie downs are not installed according to page 6.0 at bearing wall No improvements were made since last inspection Walk your property before scheduling your inspections Not ready for inspection (Again)
Erosion Control Inspection Residential Partial 1/28/2025 01/28/2025
Miscellaneous Correction
Informational
12/30/2024
Erosion control is in place and must be properly maintained until CofO
All Rough Inspection - Residential Not Ready 1/28/2025 1/28/2025 01/28/2025
Miscellaneous Correction
Corrective Action Required
01/24/2025
3711 - Strap top plate in bathroom 1 at plumbing vent line where it is bored more than 50 percent - H 2.5 truss tie downs are not installed according to page 6.0 at bearing wall 3713 - Strap top plate at bathroom 1 @ DWV of load bearing wall - Strap top plate at bathroom 2 @ DWV of load bearing wall - H 2.5 truss tie downs are not installed according to page 6.0 at bearing wall No improvements were made since last inspection Walk your property before scheduling your inspections Not ready for inspection K.Beard 01/28/25
All Rough Inspection - Residential Failed 1/29/2025 1/29/2025 01/29/2025
Miscellaneous Correction
Resolved
01/29/2025
3711 - Strap top plate in bathroom 1 at plumbing vent line where it is bored more than 50 percent - H 2.5 truss tie downs are not installed according to page 6.0 at bearing wall 3713 - Strap top plate at bathroom 1 @ DWV of load bearing wall - Strap top plate at bathroom 2 @ DWV of load bearing wall - H 2.5 truss tie downs are not installed according to page 6.0 at bearing wall No improvements were made since last inspection Walk your property before scheduling your inspections Not ready for inspection K.Beard 01/28/25
Miscellaneous Correction
Corrective Action Required
01/29/2025
3711 - Strap top plate in bathroom 1 at plumbing vent line where it is bored more than 50 percent at exterior wall 3713 - Strap top plate at bathroom 1 @ DWV of load bearing exterior Walk your property before scheduling your inspections 10:09am. KBEARD
All Rough Inspection - Residential Passed 1/30/2025 1/30/2025 01/30/2025
Miscellaneous Correction
Resolved
01/30/2025
3711 - Strap top plate in bathroom 1 at plumbing vent line where it is bored more than 50 percent at exterior wall 3713 - Strap top plate at bathroom 1 @ DWV of load bearing exterior Walk your property before scheduling your inspections 10:09am. KBEARD
Rated Assembly Inspection Passed 2/10/2025 2/10/2025 02/10/2025
Driveway Inspection Partial 3/24/2025 3/24/2025 03/24/2025
Misc
Informational
03/24/2025
3-24-25 Dustin A, dw is formed and compacted . Approved to pour
Sidewalk Inspection Partial 3/24/2025 3/24/2025 03/24/2025
Misc
Informational
03/24/2025
3-24-25 Dustin Asw has been formed and compacted. And slopes are in compliance. Approved to pour
Piers/Caissons Inspection - Residential Partial 3/31/2025 3/31/2025 03/31/2025
Informational
03/31/2025
- Piers for 3711 approved
Occupancy Inspection - Codes Residential Failed 4/1/2025 4/1/2025 04/01/2025
Misc
Corrective Action Required
04/01/2025
-Sidewalk and driveway not approved on record -As-graded plot plan is required -Final grade, sod, downspout and sump pump extension -Seal exterior wall penetrations; seal above meter, AC disconnect, seal exterior lights, etc -Ground service to copper water line in unit 3711 3711: -Label service disconnect -Provide sewer tracer wire port at grade -Complete electrical outside. Install AC unit, receptacle and weatherproof cover -Provide bottom deck stair landing; shim gap under deck beam at post support -Fix bent flashing above rear window -Install bottom garage door track bracket 10” above floor. Provide engineer design for garage door on site -Screw the exterior door embedded jamb brace into studs -Fire caulk fire partition penetrations below bathroom sinks -Label master bathroom circuit breaker -Provide dedicated receptacle for receptacle near furnace and label receptacle 3713: -Provide bottom deck stair landing; shim gap under deck beam at post support -Install anti-tipping device for kitchen range -Screw the exterior door embedded jamb brace into studs
Occupancy Inspection - Codes Residential Failed 4/3/2025 4/3/2025 04/03/2025
Misc
Corrective Action Required
04/01/2025
-Sidewalk and driveway not approved on record -As-graded plot plan is required -Final grade, sod, downspout and sump pump extension -Seal exterior wall penetrations; seal above meter, AC disconnect, seal exterior lights, etc -Ground service to copper water line in unit 3711 3711: -Label service disconnect -Provide sewer tracer wire port at grade -Provide bottom deck stair landing; shim gap under deck beam at post support -Fix bent flashing above rear window -Install bottom garage door track bracket 10” above floor. Provide engineer design for garage door on site -Fire caulk fire partition penetrations below bathroom sinks 3713: -Provide bottom deck stair landing; shim gap under deck beam at post support -Install anti-tipping device for kitchen range -Screw the exterior door embedded jamb brace into studs
Driveway Inspection Passed 4/4/2025 4/4/2025 04/04/2025
Misc
Informational
03/24/2025
3-24-25 Dustin A, dw is formed and compacted . Approved to pour 4-4-25 Dustin A, dw has been poured to city specs and slopes are in compliance . Pass
Sidewalk Inspection Partial 4/4/2025 4/4/2025 04/04/2025
Misc
Informational
03/24/2025
3-24-25 Dustin Asw has been formed and compacted. And slopes are in compliance. Approved to pour 4-4-25 Dustin A, sw has been poured to city specs, slopes are in compliance.. There are 2 valves that are missing top hats and will need to be cut to grade before closing this out
Occupancy Inspection - Codes Residential Ready for Temp CO 4/4/2025 4/4/2025 04/04/2025
Misc
Corrective Action Required
04/03/2025
-Sidewalk and driveway not approved on record -As-graded plot plan is required -Final grade, sod, downspout and sump pump extension -Seal exterior wall penetrations; seal above meter, AC disconnect, seal exterior lights, etc 3711: -Provide sewer tracer wire port at grade -Provide bottom deck stair landing; shim gap under deck beam at post support( deck stairs blocked for TCO) 3713: -Provide bottom deck stair landing; shim gap under deck beam at post support
Erosion Control Inspection Residential Failed 5/5/2025 5/5/2025 05/05/2025
Miscellaneous Correction
Informational
01/28/2025
Erosion control is in place and must be properly maintained until CofO
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
05/05/2025
05-05-25 Jamie S, Erosion control needs to be reestablished. EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Erosion Control Inspection Residential Failed - Stop Work 5/8/2025 5/8/2025 05/08/2025
Miscellaneous Correction
Informational
05/05/2025
Erosion control is in place and must be properly maintained until CofO
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
05/05/2025
05-05-25 Jamie S, Erosion control needs to be reestablished. EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. 05-08-25 Jamie S, Silt fence is still down.
Erosion Control Inspection Residential Partial 5/13/2025 5/13/2025 05/13/2025
Miscellaneous Correction
Informational
05/08/2025
Erosion control is in place and must be properly maintained until CofO
DCM3 ESC REQUIRED 2 DAY
Resolved
05/13/2025
05-05-25 Jamie S, Erosion control needs to be reestablished. EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. 05-08-25 Jamie S, Silt fence is still down. 05-13-25 Jamie S, Erosion control measures have been reestablished.
Plot Plan Inspection Failed 6/4/2025 06/04/2025
Misc
Corrective Action Required
06/04/2025
Need sod and splash blocks
Documents & Images
Date Uploaded File Type Document Name
05/30/2024 OS #87 - PERMIT APP
06/05/2024 Permit Codes Residential Plan Review
06/11/2024 Permit Codes Residential Plan Review
06/11/2024 Approved Plans APPROVED TRUSS PACKAGE
06/11/2024 Approved Plans APPROVED TRUSS LAYOUT
06/11/2024 Approved Plans APPROVED PLANS
06/12/2024 Plot Plan APPROVED PLOT PLAN
06/12/2024 Permit Codes Residential Plan Review
06/21/2024 Permit DS Building Permit
06/21/2024 Receipt Receipt for transaction:2024-005004
09/17/2024 3711 & 3713 Knoxville Ct LSMO Footing Inspection Report
09/18/2024 Letter INSPECTION SUMMARY
09/18/2024 Letter INSPECTION SUMMARY
09/19/2024 Letter INSPECTION SUMMARY
09/19/2024 Letter INSPECTION SUMMARY
09/20/2024 Letter INSPECTION SUMMARY
09/25/2024 Letter INSPECTION SUMMARY
09/25/2024 Letter INSPECTION SUMMARY
11/01/2024 Letter INSPECTION SUMMARY
12/05/2024 Letter INSPECTION SUMMARY
12/16/2024 Letter INSPECTION SUMMARY
12/16/2024 Letter INSPECTION SUMMARY
12/23/2024 Letter INSPECTION SUMMARY
12/23/2024 Letter INSPECTION SUMMARY
12/30/2024 Letter INSPECTION SUMMARY
12/30/2024 Letter INSPECTION SUMMARY
12/30/2024 Letter INSPECTION SUMMARY
12/30/2024 Letter INSPECTION SUMMARY
12/30/2024 Letter INSPECTION SUMMARY
01/02/2025 Letter INSPECTION SUMMARY
01/02/2025 Letter INSPECTION SUMMARY
01/08/2025 Specifications OS 87 UL Listing for shared wall material
01/20/2025 Engineer Report/Study ANCHOR BOLT ENGINEER LETTER
01/21/2025 Letter INSPECTION SUMMARY
01/21/2025 Letter INSPECTION SUMMARY
01/23/2025 Letter INSPECTION SUMMARY
01/24/2025 Letter INSPECTION SUMMARY
01/28/2025 Letter INSPECTION SUMMARY
01/28/2025 Letter INSPECTION SUMMARY
01/29/2025 Letter INSPECTION SUMMARY
01/30/2025 Letter INSPECTION SUMMARY
02/10/2025 Letter INSPECTION SUMMARY
03/24/2025 Letter INSPECTION SUMMARY
03/24/2025 Letter INSPECTION SUMMARY
03/31/2025 Letter INSPECTION SUMMARY
04/03/2025 Letter INSPECTION SUMMARY
04/04/2025 Letter INSPECTION SUMMARY
04/04/2025 Letter INSPECTION SUMMARY
04/04/2025 Letter INSPECTION SUMMARY
04/04/2025 Letter INSPECTION SUMMARY
05/05/2025 Letter INSPECTION SUMMARY
05/08/2025 Letter Stop Work Order
05/13/2025 Letter INSPECTION SUMMARY
06/03/2025 Plot Plan APPROVED AS BUILT PLOT PLAN
06/04/2025 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home