Permit Application Status

PRRES20240545


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20240545
Building Permit - Residential
Certificate of Occupancy
NEW 3 OR 4 FAMILY
NEW TOWNHOUSE. UNFINISHED BASEMENT. ROOF TRUSSES. UNCOVERED DECK. STOP WORK ORDER generated on 04/25/2024 12:00 AM by username 'Dustin Agcopra'. STOP WORK ORDER removed on 04/25/2024 12:00 AM by username 'Dustin Agcopra'.
02/08/2024
02/20/2024
08/12/2024
11/04/2024
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
CARUTHERS ELECTRICAL LLC, Address:30905 E TRUMAN RD, Phone:(816) 508-9050  
BILL'S PLUMBING SERVICE LLC, Address:308 E PARK STREET, Phone:(913) 829-8213  
JASONH@CLOVERANDHIVE.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee for New 3 or 4 Family $4,942.58 $4,942.58 Paid 02/20/2024
Water Tap Fee $15,040.00 $15,040.00 Paid 02/20/2024
Water Meter Fee $2,721.84 $2,721.84 Paid 02/20/2024
Sanitary Sewer Development Fee $8,636.00 $8,636.00 Paid 02/20/2024
Right of Way Permit Fee $85.00 $85.00 Paid 02/20/2024
Residential Excise Tax Fee $2,480.64 $2,480.64 Paid 02/20/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 07/09/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 07/09/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 09/23/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 09/23/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 09/26/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 11/01/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 3/22/2024 03/22/2024
Miscellaneous Correction
Corrective Action Required
03/22/2024
Footing has been completed and signed off by a third party. The third party stated in their report that erosion control was in place at the time of their inspection. A spot inspection was conducted and full erosion control measures were not implemented at the site. Footing inspection is denied until full erosion control is completed 03/22/24 KBEARD
Erosion Control Inspection Residential Partial 3/26/2024 03/26/2024
Miscellaneous Correction
Informational
03/26/2024
Erosion control is in place and needs to be maintained until CofO
Footing Inspection - Residential Passed 3/28/2024 03/28/2024
Miscellaneous Correction
Resolved
03/28/2024
Footing has been completed and signed off by a third party. The third party stated in their report that erosion control was in place at the time of their inspection. A spot inspection was conducted and full erosion control measures were not implemented at the site. Footing inspection is denied until full erosion control is completed 03/22/24 KBEARD
Miscellaneous Correction
Informational
03/28/2024
Footing passed by a third party. Piers were not mentioned in the footing report
Erosion Control Inspection Residential Passed 3/28/2024 03/28/2024
Miscellaneous Correction
Informational
03/26/2024
Erosion control is in place and needs to be maintained until CofO
Miscellaneous Correction
Informational
03/28/2024
Erosion control is in place and needs to be maintained until CofO
Sewer Service Inspection - R Partial 4/8/2024 (1:15) 4/8/2024 04/08/2024
Miscellaneous Correction
Informational
04/08/2024
Sewer passed at 3713 and 3715 only, this is a partial pass. Other units will be scheduled at a later date
Water Service Inspection - R Partial 4/9/2024 4/9/2024 04/09/2024
Miscellaneous Correction
Informational
04/09/2024
Water at 3713 and 3715 both passed inspection. Other units will be scheduled at a later date. This is a partial pass only
Sewer Service Inspection - R Passed 4/9/2024 4/9/2024 04/09/2024
Miscellaneous Correction
Informational
04/08/2024
Sewer passed at 3713 and 3715 only, this is a partial pass. Other units will be scheduled at a later date
Water Service Inspection - R Passed 4/10/2024 04/10/2024
Miscellaneous Correction
Informational
04/09/2024
Water at 3713 and 3715 both passed inspection. Other units will be scheduled at a later date. This is a partial pass only
Erosion Control Inspection Residential Partial 4/16/2024 04/16/2024
Misc
Corrective Action Required
04/16/2024
-NW Corner, silt fence needs repair EROSION CONTROL MUST BE MAINTAINED UNTIL C of O
Underslab Plumbing Inspection - Residential Failed 4/16/2024 4/16/2024 04/16/2024
Misc
Corrective Action Required
04/16/2024
-Remove all wood forms, wood stakes and construction debris
Underslab Plumbing Inspection - Residential Not Ready 4/17/2024 4/17/2024 04/17/2024
Misc
Corrective Action Required
04/16/2024
-Remove all wood forms, wood stakes and construction debris
Misc
Corrective Action Required
04/17/2024
-Erosion control must be in place (NW corner) before reinspection can take place
Underslab Plumbing Inspection - Residential Passed 4/18/2024 4/18/2024 04/18/2024
Misc
Resolved
04/18/2024
-Remove all wood forms, wood stakes and construction debris
Misc
Resolved
04/18/2024
-Erosion control must be in place (NW corner) before reinspection can take place
Erosion Control Inspection Residential Passed 04/25/2024
Misc
Corrective Action Required
04/16/2024
-NW Corner, silt fence needs repair EROSION CONTROL MUST BE MAINTAINED UNTIL C of O
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
04/25/2024
4-25-24 Dustin A, EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
All Rough Inspection - Residential Failed 5/24/2024 5/24/2024 05/24/2024
Miscellaneous Correction
Corrective Action Required
05/24/2024
Exterior of garage was covered and portal inspection was not performed This was a partial inspection only
Rated Assembly Inspection Failed 5/29/2024 5/29/2024 05/29/2024
Miscellaneous Correction
Corrective Action Required
05/29/2024
Rated assembly inspection was scheduled for an all rough.
All Rough Inspection - Residential Failed 5/29/2024 05/29/2024
Miscellaneous Correction
Resolved
05/29/2024
Exterior of garage was covered and portal inspection was not performed This was a partial inspection only
Miscellaneous Correction
Corrective Action Required
05/29/2024
- Provide tension strap capability for straps installed at garage portal. Tension straps must meet code Table R602.10.6 This is a partial all rough inspection only
Erosion Control Inspection Residential Failed 6/11/2024 06/11/2024
Misc
Resolved
06/11/2024
-NW Corner, silt fence needs repair EROSION CONTROL MUST BE MAINTAINED UNTIL C of O
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
06/11/2024
4-25-24 Dustin A, EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Miscellaneous Correction
Corrective Action Required
06/11/2024
Silt fence and or straw waddle is missing, damaged or needs to be repaired or replaced. Full erosion control must be installed and maintained until CofO Erosion control measures must be in place before scheduling anymore inspections
Erosion Control Inspection Residential Partial 7/1/2024 07/01/2024
Miscellaneous Correction
Resolved
07/01/2024
Silt fence and or straw waddle is missing, damaged or needs to be repaired or replaced. Full erosion control must be installed and maintained until CofO Erosion control measures must be in place before scheduling anymore inspections
Miscellaneous Correction
Informational
07/01/2024
Full erosion control is in place and must be maintained until CofO
Gas Service Inspection - Residential Passed 7/1/2024 07/01/2024
All Rough Inspection - Residential Not Ready 7/1/2024 7/1/2024 07/01/2024
Miscellaneous Correction
Resolved
07/01/2024
- Provide tension strap capability for straps installed at garage portal. Tension straps must meet code Table R602.10.6 This is a partial all rough inspection only
Miscellaneous Correction
Corrective Action Required
07/01/2024
All units -Fire blocking is missing -Not a complete list. -Not ready for inspections
Erosion Control Inspection Residential Partial 7/10/2024 07/10/2024
Miscellaneous Correction
Resolved
07/10/2024
Full erosion control is in place and must be maintained until CofO
Miscellaneous Correction
Informational
07/10/2024
Full erosion control is in place and must be maintained until CofO
Electrical Service Inspection Passed 7/10/2024 7/10/2024 07/10/2024
All Rough Inspection - Residential Failed 7/10/2024 7/10/2024 07/10/2024
Miscellaneous Correction
Resolved
07/10/2024
All units -Fire blocking is missing -Not a complete list. -Not ready for inspections
Miscellaneous Correction
Corrective Action Required
07/10/2024
3711-3713-3715 & 3717 SW Clayton All rough 3711 Garage truss area does not have a attic access installed Anchor bolt at overhead garage door needs to be tightened down Missing nail in joist hanger above pantry Install joist hangers in 2x10 above front porch where cut out for plumbing is located Nail bedroom 1 N/W corner to code Truss tie down screw is not installed in bathroom 1 toilet room on North wall Fire block holes in top plate in closet of bedroom 1 Nail basement N/E corner to code 3713 Second LIB in garage at south wall is not installed Garage truss area does not have a attic access installed LIB’s at garage east wall are both missing nails Nails missing in kitchen LIB Vertical fire blocking is missing at the stairwell landing Latterly support the trusses in the attic area Nail outside corner of bedroom 3 to code 3715 Have engineer address garage North side sole plate not fully bearing on the foundation wall Garage truss area does not have a attic access installed Powder bath vent fan is not installed to the exterior Kitchen to stairwell LVL’s should be supported by (3)2x4 Ceiling joist hanger at foyer to great room is missing a nail Vertical fire blocking is missing at S/E corner area of the great room Nail guards are needed at waste line above front door 2x10 floor joist have been notched within 2 inches of the bottom edge in the basement for electrical service cable 3717 fire block holes above ceiling at electrical in the foyer Install joist hanger above front porch for plumbing cut out Attic access is not installed Have approved fire caulking at electrical service cable between units No garage attic access is installed
Rated Assembly Inspection Failed 7/10/2024 7/10/2024 07/10/2024
Miscellaneous Correction
Resolved
07/10/2024
Rated assembly inspection was scheduled for an all rough.
Miscellaneous Correction
Corrective Action Required
07/10/2024
3717-3715-3713 & 3711 SW Clayton Rated assembly 3717 -Provide caulking details for electrical service cable at rated basement wall -Roof vent cut out within 4 feet to rated assembly wall -Gap at the ridge is greater than 1/4 of an inch 3715 -Finish vertical fire blocking at great room S/E corner area -Provide caulking information at basement electrical service cable at rated assembly walls -Ridge in attic area has a greater than 1/4 of an inch gap in fire rated plywood along south side 3713 3711
All Rough Inspection - Residential Failed 7/17/2024 7/17/2024 07/17/2024
Miscellaneous Correction
Corrective Action Required
07/10/2024
3711-3713-3715 & 3717 SW Clayton All rough 3711 3713 3715 -2x10 floor joist have been notched within 2 inches of the bottom edge in the basement for electrical service cable Shawn Hoffman 07/17/2024 2:05 PM ENGINEERS CORRECTIONS NOT COMPLETED 3717 -Have approved fire caulking at electrical service cable between units
Rated Assembly Inspection Failed 7/17/2024 7/17/2024 07/17/2024
Miscellaneous Correction
Corrective Action Required
07/10/2024
3717-3715-3713 & 3711 SW Clayton Rated assembly 3717 -Provide caulking details for electrical service cable at rated basement wall -Roof vent cut out within 4 feet to rated assembly wall -Gap at the ridge is greater than 1/4 of an inch 3715 -Finish vertical fire blocking at great room S/E corner area -Provide caulking information at basement electrical service cable at rated assembly walls -Ridge in attic area has a greater than 1/4 of an inch gap in fire rated plywood along south side 3713 -Span from the garage to the kitchen is over 10 feet and needs to be vertically fire blocked -Seal electrical service cable hole in basement North wall to fill all gaps 3711 -Roof vent is within four feet of rated assembly wall
Rated Assembly Inspection Failed 7/17/2024 07/17/2024
Miscellaneous Correction
Corrective Action Required
07/17/2024
3717-3715-3713 & 3711 SW Clayton Rated assembly 3717 -Provide caulking details for electrical service cable at rated basement wall -Roof vent cut out within 4 feet to rated assembly wall -Gap at the ridge is greater than 1/4 of an inch 3715 -Provide caulking information at basement electrical service cable at rated assembly walls -Ridge in attic area has a greater than 1/4 of an inch gap in fire rated plywood along south side 3713 3711
Rated Assembly Inspection Partial 7/19/2024 7/19/2024 07/19/2024
Miscellaneous Correction
Resolved
07/19/2024
3717-3715-3713 & 3711 SW Clayton Rated assembly 3717 -Provide caulking details for electrical service cable at rated basement wall -Roof vent cut out within 4 feet to rated assembly wall -Gap at the ridge is greater than 1/4 of an inch 3715 -Provide caulking information at basement electrical service cable at rated assembly walls -Ridge in attic area has a greater than 1/4 of an inch gap in fire rated plywood along south side 3713 3711
Miscellaneous Correction
Informational
07/19/2024
Schedule screw pattern when ready
All Rough Inspection - Residential Failed 7/19/2024 7/19/2024 07/19/2024
Miscellaneous Correction
Resolved
07/19/2024
3711-3713-3715 & 3717 SW Clayton All rough 3711 3713 3715 -2x10 floor joist have been notched within 2 inches of the bottom edge in the basement for electrical service cable Shawn Hoffman 07/17/2024 2:05 PM ENGINEERS CORRECTIONS NOT COMPLETED 3717 -Have approved fire caulking at electrical service cable between units
Miscellaneous Correction
Corrective Action Required
07/19/2024
3715 -2x10 floor joist have been notched within 2 inches of the bottom edge in the basement for electrical service cable ENGINEERS CORRECTIONS NOT COMPLETED
All Rough Inspection - Residential Not Ready 7/22/2024 7/22/2024 07/22/2024
Miscellaneous Correction
Resolved
07/22/2024
3715 -2x10 floor joist have been notched within 2 inches of the bottom edge in the basement for electrical service cable ENGINEERS CORRECTIONS NOT COMPLETED
Miscellaneous Correction
Corrective Action Required
07/22/2024
3715 -2x10 floor joist have been notched within 2 inches of the bottom edge in the basement for electrical service cable ENGINEERS CORRECTIONS NOT COMPLETED Still need to install CS-16 metal strap per engineers letter (#2 a)
All Rough Inspection - Residential Not Ready 7/23/2024 7/23/2024 07/23/2024
Miscellaneous Correction
Resolved
07/23/2024
3715 -2x10 floor joist have been notched within 2 inches of the bottom edge in the basement for electrical service cable ENGINEERS CORRECTIONS NOT COMPLETED Still need to install CS-16 metal strap per engineers letter (#2 a)
Miscellaneous Correction
Corrective Action Required
07/23/2024
3715 -2x10 floor joist have been notched within 2 inches of the bottom edge in the basement for electrical service cable ENGINEERS CORRECTIONS NOT COMPLETED Still need to install CS-16 metal strap per engineers letter (#2 a) Re inspection at 8:35 am showed no improvement has been observed 07/23/24. KBEARD
All Rough Inspection - Residential Passed 7/24/2024 7/24/2024 07/24/2024
Miscellaneous Correction
Resolved
07/24/2024
3715 -2x10 floor joist have been notched within 2 inches of the bottom edge in the basement for electrical service cable ENGINEERS CORRECTIONS NOT COMPLETED Still need to install CS-16 metal strap per engineers letter (#2 a) Re inspection at 8:35 am showed no improvement has been observed 07/23/24. KBEARD
Rated Assembly Inspection Failed 7/31/2024 7/31/2024 07/31/2024
Miscellaneous Correction
Resolved
07/31/2024
Schedule screw pattern when ready
Misc
Corrective Action Required
07/31/2024
3711,3713,3715,3717 sw Clayton pl 3711 - Ok 3713 - ok 3715 - second floor south wall near sill plate (front and back) 3817 - Ok
Rated Assembly Inspection Passed 8/1/2024 8/1/2024 08/01/2024
Misc
Resolved
08/01/2024
Sidewalk Inspection Partial 8/8/2024 08/08/2024
Misc
Informational
08/08/2024
8-8-24 PS Sidewalk pre pour, forms in place, aggregate compacted, approved to pour
Driveway Inspection Partial 8/8/2024 08/08/2024
Misc
Informational
08/08/2024
8-8-24 PS Driveway approach pre pour, forms in place and aggregate compacted, approved to pour
Piers/Caissons Inspection - Residential Failed 8/21/2024 08/21/2024
Miscellaneous Correction
Informational
08/21/2024
Piers for back decks at 3711 and 3713 both passed, other piers will be scheduled at a later date This is a partial pier pass only
Driveway Inspection Passed 8/22/2024 8/22/2024 08/22/2024
Misc
Informational
08/08/2024
8-8-24 PS Driveway approach pre pour, forms in place and aggregate compacted, approved to pour 8-22-24 PS Driveway approach meets LS and ADA specs
Sidewalk Inspection Passed 8/22/2024 8/22/2024 08/22/2024
Misc
Informational
08/22/2024
8-22-24 PS Sidewalk meets ADA and LS specs
Erosion Control Inspection Residential Partial 8/26/2024 08/26/2024
Miscellaneous Correction
Informational
07/10/2024
Full erosion control is in place and must be maintained until CofO
Piers/Caissons Inspection - Residential Passed 8/26/2024 08/26/2024
Miscellaneous Correction
Resolved
08/26/2024
Piers for back decks at 3711 and 3713 both passed, other piers will be scheduled at a later date This is a partial pier pass only
Piers/Caissons Inspection - Residential Passed 9/17/2024 09/17/2024
Miscellaneous Correction
Corrective Action Required
09/17/2024
All four units had concrete poured without inspection for depth
Occupancy Inspection - Codes Residential Failed 9/20/2024 9/20/2024 09/20/2024
Miscellaneous Correction
Corrective Action Required
09/20/2024
3711 SW Clayton Occupancy 3711 First to second riser going up stairs from the main entry has a height difference greater than the code allowed 3/8 of an inch Electrical receptacle in master bathroom has a gap in between the plate and receptacle Seal attic access hatch 3713 Nail missing in joist hanger under deck See note on 3711 about stair riser height 3715 Same notes about riser height difference in units 3713 and 3711 Inspection stopped due to similar issues with other units This is not a complete list 09/20/2024. KBEARD 10:34 am
Erosion Control Inspection Residential Partial 9/20/2024 09/20/2024
Miscellaneous Correction
Informational
08/26/2024
Full erosion control is in place and must be maintained until CofO
Occupancy Inspection - Codes Residential Failed 9/24/2024 9/24/2024 09/24/2024
Miscellaneous Correction
Resolved
09/24/2024
3711 SW Clayton Occupancy 3711 First to second riser going up stairs from the main entry has a height difference greater than the code allowed 3/8 of an inch Electrical receptacle in master bathroom has a gap in between the plate and receptacle Seal attic access hatch 3713 Nail missing in joist hanger under deck See note on 3711 about stair riser height 3715 Same notes about riser height difference in units 3713 and 3711 Inspection stopped due to similar issues with other units This is not a complete list 09/20/2024. KBEARD 10:34 am
Miscellaneous Correction
Corrective Action Required
09/24/2024
3711 SW Clayton Occupancy 3711 First to second riser going up stairs from the main entry has a height difference greater than the code allowed 3/8 of an inch Electrical receptacle in master bathroom has a gap in between the plate and receptacle Seal attic access hatch 3713 Nail missing in joist hanger under deck See note on 3711 about stair riser height 3715 Oven anti tip mechanism is not working Garage to house door latch is not working Seal hole in sheet rock at steel post in garage south wall Last two step risers to up stairs has a greater than 3/8 of an inch code height difference 3717 First step going from the main entrance to the basement has a riser height greater the the code allowed 7 3/4 inches All units Sod, splash pads and sump pump extensions are not installed Check for exterior penetration gaps As graded plot plan is not uploaded for plot plan inspection Under deck inspection was not completed due to rain for 3715 and 3717
Occupancy Inspection - Codes Residential Ready for Temp CO 9/26/2024 9/26/2024 09/26/2024
Miscellaneous Correction
Resolved
09/26/2024
3711 SW Clayton Occupancy 3711 First to second riser going up stairs from the main entry has a height difference greater than the code allowed 3/8 of an inch Electrical receptacle in master bathroom has a gap in between the plate and receptacle Seal attic access hatch 3713 Nail missing in joist hanger under deck See note on 3711 about stair riser height 3715 Oven anti tip mechanism is not working Garage to house door latch is not working Seal hole in sheet rock at steel post in garage south wall Last two step risers to up stairs has a greater than 3/8 of an inch code height difference 3717 First step going from the main entrance to the basement has a riser height greater the the code allowed 7 3/4 inches All units Sod, splash pads and sump pump extensions are not installed Check for exterior penetration gaps As graded plot plan is not uploaded for plot plan inspection
Miscellaneous Correction
Corrective Action Required
09/26/2024
3711 to 3717 SW Clayton Occupancy (2) 3711 Nail missing in deck joist hanger 3713 Nail missing in deck joist hanger 3715 Missing nails in deck joist hanger 3717 Missing nails in deck joist hanger All units Sod, splash pads and sump pump extensions are not installed Check for exterior penetration gaps As graded plot plan is not uploaded for plot plan inspection All units passed for TCO only
Plot Plan Inspection Passed 10/9/2024 10/09/2024
Erosion Control Inspection Residential Passed 10/9/2024 10/09/2024
Miscellaneous Correction
Resolved
10/09/2024
Full erosion control is in place and must be maintained until CofO
Occupancy Inspection - Codes Residential Failed 10/24/2024 10/24/2024 10/24/2024
Miscellaneous Correction
Resolved
10/24/2024
3711 to 3717 SW Clayton Occupancy (2) 3711 Nail missing in deck joist hanger 3713 Nail missing in deck joist hanger 3715 Missing nails in deck joist hanger 3717 Missing nails in deck joist hanger All units Sod, splash pads and sump pump extensions are not installed Check for exterior penetration gaps As graded plot plan is not uploaded for plot plan inspection All units passed for TCO only
Miscellaneous Correction
Corrective Action Required
10/24/2024
3711 SW Clayton Occupancy (2) 3711 Nail missing in deck joist hanger Lower water meter lid to ground level 3717 Missing nail in deck joist hanger
Occupancy Inspection - Codes Residential Ready for Temp CO 10/29/2024 10/29/2024
Miscellaneous Correction
Corrective Action Required
10/24/2024
3711 SW Clayton Occupancy (2) 3711 Nail missing in deck joist hanger Lower water meter lid to ground level 3717 Missing nail in deck joist hanger Builder sent in a TCO extension form new permit extension to 11/24/2024 KBEARD
Occupancy Inspection - Codes Residential Failed 11/1/2024 11/1/2024 11/01/2024
Miscellaneous Correction
Resolved
11/01/2024
3711 SW Clayton Occupancy (2) 3711 Nail missing in deck joist hanger Lower water meter lid to ground level 3717 Missing nail in deck joist hanger Builder sent in a TCO extension form new permit extension to 11/24/2024 KBEARD
Miscellaneous Correction
Corrective Action Required
11/01/2024
Pay $50 fee associated with this permit
Occupancy Inspection - Codes Residential Full C of O 11/4/2024 11/4/2024 11/04/2024
Miscellaneous Correction
Resolved
11/04/2024
Pay $50 fee associated with this permit
Documents & Images
Date Uploaded File Type Document Name
02/20/2024 Permit Codes Residential Plan Review
02/20/2024 Permit DS Building Permit
02/20/2024 Receipt Receipt for transaction:2024-000944
03/22/2024 Letter INSPECTION SUMMARY
04/09/2024 Letter INSPECTION SUMMARY
04/09/2024 Letter INSPECTION SUMMARY
04/10/2024 Letter INSPECTION SUMMARY
04/10/2024 Letter INSPECTION SUMMARY
04/16/2024 Letter INSPECTION SUMMARY
04/16/2024 Letter INSPECTION SUMMARY
04/17/2024 Letter INSPECTION SUMMARY
04/18/2024 Letter INSPECTION SUMMARY
04/25/2024 Letter Stop Work Order
04/25/2024 Letter INSPECTION SUMMARY
05/24/2024 Letter INSPECTION SUMMARY
05/24/2024 Letter Stop Work Order
07/01/2024 Letter INSPECTION SUMMARY
07/01/2024 Letter INSPECTION SUMMARY
07/01/2024 Letter INSPECTION SUMMARY
07/01/2024 Letter INSPECTION SUMMARY
07/09/2024 Receipt Receipt for transaction:2024-005607
07/10/2024 Letter INSPECTION SUMMARY
07/10/2024 Letter INSPECTION SUMMARY
07/10/2024 Letter INSPECTION SUMMARY
07/10/2024 Letter INSPECTION SUMMARY
07/10/2024 Letter INSPECTION SUMMARY
07/17/2024 Letter INSPECTION SUMMARY
07/22/2024 SUMMIT - FJ UNDER TUB - 240719
07/22/2024 Letter INSPECTION SUMMARY
07/23/2024 Letter INSPECTION SUMMARY
02/08/2024 OS # 46 - PERMIT APP
05/29/2024 Letter INSPECTION SUMMARY
04/08/2024 Letter INSPECTION SUMMARY
03/28/2024 Letter INSPECTION SUMMARY
08/22/2024 Letter INSPECTION SUMMARY
08/22/2024 Letter INSPECTION SUMMARY
08/26/2024 Letter INSPECTION SUMMARY
08/26/2024 Letter INSPECTION SUMMARY
09/17/2024 Letter INSPECTION SUMMARY
09/20/2024 Letter INSPECTION SUMMARY
09/20/2024 Letter INSPECTION SUMMARY
09/20/2024 Letter INSPECTION SUMMARY
09/23/2024 Receipt Receipt for transaction:2024-007834
09/24/2024 Letter INSPECTION SUMMARY
09/26/2024 Letter INSPECTION SUMMARY
09/26/2024 Certificate/License Codes Temporary Certificate of Occupancy
09/26/2024 Receipt Receipt for transaction:2024-007952
10/08/2024 Plot Plan approved as graded plot plan
10/09/2024 Letter INSPECTION SUMMARY
10/09/2024 Letter INSPECTION SUMMARY
03/28/2024 Letter INSPECTION SUMMARY
10/25/2024 Osage #46 - TCO Extension Request Form
03/28/2024 Letter INSPECTION SUMMARY
11/01/2024 Letter INSPECTION SUMMARY
11/01/2024 Certificate/License Codes Temporary Certificate of Occupancy
11/01/2024 Receipt Receipt for transaction:2024-008725
11/04/2024 Letter Field Certificate of Occupancy
11/04/2024 Letter Codes Final Certificate of Occupancy
03/26/2024 Letter INSPECTION SUMMARY
03/22/2024 3RD Party Insp Report 3711, 3713, 3715, & 3717 SW Clayton Pl LSMO Footing Inspection Report 3-22-24
02/20/2024 Approved Plans APPROVED TRUSS PACKAGE
02/20/2024 Approved Plans APPROVED TRUSS LAYOUT
02/20/2024 Plot Plan APPROVED PLOT PLAN
02/14/2024 Permit Codes Residential Plan Review
02/13/2024 Permit Codes Residential Plan Review
02/13/2024 Approved Plans APPROVED PLANS
07/19/2024 Letter INSPECTION SUMMARY
07/19/2024 Letter INSPECTION SUMMARY
07/17/2024 Letter INSPECTION SUMMARY
07/17/2024 Engineer Report/Study ENGINEER FRAMING LETTER
06/11/2024 Letter INSPECTION SUMMARY
05/29/2024 Letter INSPECTION SUMMARY
07/19/2024 Letter INSPECTION SUMMARY
07/24/2024 Letter INSPECTION SUMMARY
07/31/2024 Letter INSPECTION SUMMARY
08/01/2024 Letter INSPECTION SUMMARY
08/08/2024 Letter INSPECTION SUMMARY
08/21/2024 Letter INSPECTION SUMMARY
08/08/2024 Letter INSPECTION SUMMARY
10/24/2024 Letter INSPECTION SUMMARY
10/29/2024 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home