Summary
PRRES20225143
Building Permit - Residential
Certificate of Occupancy
SUMMIT VIEW FARMS DEVELOPMENT GROUP LLC
NEW SINGLE FAMILY
NEW HOUSE- Basement finish added 9/18/23 - COVERED DECK STOP WORK ORDER generated on 10/28/2022 12:00 AM by username 'Mitchell Schwarz'. STOP WORK ORDER removed on 12/09/2022 12:00 AM by username 'Shawn Hoffman'. STOP WORK ORDER generated on 07/03/2023 12:00 AM by username 'Alex Fischer'. STOP WORK ORDER removed on 07/05/2023 12:00 AM by username 'Khanh Nguyen'.
10/12/2022
10/25/2022
04/15/2023
05/23/2024
Locations
Property
69520082200000000

Address
2306 SW SERENA PL, LEES SUMMIT, MO 64082

69-520-08-22-00-0-00-000
Contacts
BILL KENNEY & ASSOCIATES, Address:P O BOX 291, Phone:(816) 838-0552  
Bill Kenney, Address:PO Box 291, Phone:(816) 838-0552  
SUMMIT VIEW FARMS DEVELOPMENT GROUP LLC, Address:13450 E STATE ROUTE 150  
MIDWEST HEATING COOLING & PLUMBING, Address:13228 HOLMES RD, Phone:(816) 943-8513  
INHOME SYSTEMS LLC, Address:510 MISSION RD SW, Phone:(816) 372-0483  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331401-Water Tap Fee $3,730.00 $3,730.00 Paid 10/25/2022
8350015-Water Meter Fee $550.50 $550.50 Paid 10/25/2022
8331507-Sanitary Sewer Development Fee $1,384.00 $1,384.00 Paid 10/25/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 10/25/2022
7232302-Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 10/25/2022
9110078-Valuation Fee New Single Family $1,986.97 $1,986.97 Paid 10/25/2022
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 11/05/2022
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 11/05/2022
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 07/11/2023
9110078-Valuation Fee New Single Family $117.83 $117.83 Paid 09/18/2023
$2,104.80
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 09/20/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 01/04/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed - Stop Work 10/28/2022 10/28/2022
Misc
Corrective Action Required
10/28/2022
no erosion control stop work issued
Driveway Inspection Not Ready 10/31/2022 10/31/2022
Misc
Informational
10/31/2022
10-31-22 RH. Nothing is formed up and aggregate is not placed and compacted.
Sidewalk Inspection Not Ready 10/31/2022 10/31/2022
Misc
Informational
10/31/2022
10-31-22 RH. Nothing is formed up and aggregate is not placed or compacted.
Erosion Control Inspection Residential Passed 12/9/2022 12/09/2022
Erosion Control Inspection Residential Failed 12/12/2022 12/12/2022
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
12/12/2022
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
Underslab Plumbing Inspection - Residential Failed 12/12/2022 12/12/2022
Misc
Corrective Action Required
12/12/2022
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
Underslab Plumbing Inspection - Residential Failed 12/19/2022 12/19/2022 12/19/2022
Misc
Resolved
12/19/2022
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
Misc
Corrective Action Required
12/19/2022
plumbing covered by to much ice to see and inspect. uncover for reinspection
Footing Inspection - Residential Passed 1/5/2023 01/05/2023
Misc
Corrective Action Required
10/28/2022
no erosion control stop work issued
Sewer Service Inspection - R Passed 1/5/2023 (8:15) 1/5/2023 01/05/2023
Underslab Plumbing Inspection - Residential Passed 1/5/2023 1/5/2023 01/05/2023
Misc
Corrective Action Required
12/19/2022
plumbing covered by to much ice to see and inspect. uncover for reinspection
Erosion Control Inspection Residential Failed 1/5/2023 01/05/2023
DCM6 ESC INSP DENIED STREET CLEAN UP
Resolved
01/05/2023
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
01/05/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Water Service Inspection - R Passed 1/10/2023 (10:45) 1/10/2023 01/10/2023
Piers/Caissons Inspection - Residential Failed 4/14/2023 04/14/2023
Misc
Corrective Action Required
04/14/2023
Piers incorrect size.
Electrical Service Inspection Failed 6/16/2023 6/16/2023 06/16/2023
Misc
Corrective Action Required
06/16/2023
-Remove panel bonding screw at sub panel. -bond gas line
Gas Service Inspection - Residential Passed 6/16/2023 6/16/2023 06/16/2023
All Rough Inspection - Residential Not Ready 6/16/2023 6/16/2023 06/16/2023
Misc
Corrective Action Required
06/16/2023
Inspection denied No plans on site.
All Rough Inspection - Residential Failed 6/19/2023 6/19/2023 06/19/2023
Misc
Resolved
06/19/2023
Inspection denied No plans on site.
Misc
Corrective Action Required
06/19/2023
-minimum 3 studs required at exterior wall corners (see garage portal frame) -address over notched floor joist above garage For dwv -address floor joist notched within mid fine 1/3 above garage -address holes for pex drilled closer than 2” to one another in floor joists above garage 2 places -missing stud at hvac chase garage entry -bed 5 seal top plate penetration E wall -bed 5 bath closet, seal top plate penetrations -seal joist space used for R/A above kitchen -address broken 2x4 under beam at breakfast nook. -fire block left of great room windows plumbing chase, to ceiling space -seal penetrations in R/a joist space right of fireplace -address rafters to ceiling joist connections above front entry -address top plate blocks -Address rafter landing on 4 blocks -address over notched ceiling joist above bed 3 -address top plate connections at exterior corners bed 2 -block sheathing breaks in bed 2 -address 2nd floor attic access covered by hvac -block sheathing breaks in master closet -address rafters landing on 4 blocks -address roof supports through out. Multiple locations landing incorrectly and/or on non load bearing walls -missing stud at hvac chase in master -uncover covered patio and address notched ceiling joists. Leave uncovered for inspection -address top plate penetration left of laundry entry -address wall space to ceiling space at stairwell -address holes drilled closer than 2” to one another in floor joists at sub panel -solid block 2 joist bays in 4’ OC for joist running parallel to foundation walls (see framing notes (6) -beam in basement to be 3 1/2” per plans -address sheathing at front of house where staples used. Not to plans. Incorrect staples used
Erosion Control Inspection Residential Failed 6/19/2023 06/19/2023
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
01/05/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Misc
Corrective Action Required
06/19/2023
No further inspections until overgrown vegetation is addressed
All Rough Inspection - Residential Failed 7/3/2023 07/03/2023
Misc
Corrective Action Required
06/19/2023
-address rafters to ceiling joist connections above front entry -address top plate blocks -Address rafter landing on 4 blocks -address over notched ceiling joist above bed 3 -address top plate connections at exterior corners bed 2 -block sheathing breaks in bed 2 -address 2nd floor attic access covered by hvac -block sheathing breaks in master closet -address rafters landing on 4 blocks -address roof supports through out. Multiple locations landing incorrectly and/or on non load bearing walls -missing stud at hvac chase in master -uncover covered patio and address notched ceiling joists. Leave uncovered for inspection -address top plate penetration left of laundry entry -address wall space to ceiling space at stairwell -address holes drilled closer than 2” to one another in floor joists at sub panel -solid block 2 joist bays in 4’ OC for joist running parallel to foundation walls (see framing notes (6) -beam in basement to be 3 1/2” per plans -address sheathing at front of house where staples used. Not to plans. Incorrect staples used
Misc
Corrective Action Required
07/03/2023
-Missing plans, unable to complete inspection
Misc
Corrective Action Required
07/03/2023
-They have begun insulating, must stop insulating and remove in areas that require further inspection
Electrical Service Inspection Passed 7/5/2023 7/5/2023 07/05/2023
Misc
Resolved
07/05/2023
-Remove panel bonding screw at sub panel. -bond gas line
All Rough Inspection - Residential Failed 7/5/2023 7/5/2023 07/05/2023
Misc
Corrective Action Required
07/03/2023
-address roof supports through out. Multiple locations landing incorrectly and/or on non load bearing walls **Install longer beam to transfer roof load above bedroom 2 to bearing wall -uncover covered patio and address notched ceiling joists. Leave uncovered for inspection **Header off over-notched ceiling joist -address wall space to ceiling space at stairwell **Fb stair well wall space from horizontal space -solid block 2 joist bays in 4’ OC for joist running parallel to foundation walls (see framing notes (6)
Misc
Resolved
07/05/2023
-Missing plans, unable to complete inspection
Misc
Resolved
07/05/2023
-They have begun insulating, must stop insulating and remove in areas that require further inspection
All Rough Inspection - Residential Failed 7/10/2023 7/10/2023 07/10/2023
Misc
Corrective Action Required
07/05/2023
-uncover covered patio and address notched ceiling joists. Leave uncovered for inspection **Header off over-notched ceiling joist -address wall space to ceiling space at stairwell **Fb stair well wall space from horizontal space every 10’ and to under stairs
All Rough Inspection - Residential Failed 7/10/2023 07/10/2023
Misc
Corrective Action Required
07/10/2023
-address wall space to ceiling space at stairwell **Fb stair well wall space from horizontal space every 10’ and to under stairs
All Rough Inspection - Residential Failed 7/11/2023 7/11/2023 07/11/2023
Misc
Corrective Action Required
07/10/2023
-address wall space to ceiling space at stairwell **Fb stair well wall space from horizontal space every 10’ and to under stairs Paper faced insulation can not be used as fireblocking
All Rough Inspection - Residential Passed 7/12/2023 7/12/2023 07/12/2023
Misc
Resolved
07/12/2023
-address wall space to ceiling space at stairwell **Fb stair well wall space from horizontal space every 10’ and to under stairs Paper faced insulation can not be used as fireblocking
Driveway Inspection Passed 7/27/2023 7/27/2023 07/28/2023
Misc
Informational
10/31/2022
10-31-22 RH. Nothing is formed up and aggregate is not placed and compacted. 7-27-23 BR Driveway is formed up and compacted ready for concrete. 7-28-23 BR Driveway is constructed to LS specification.
All Rough Inspection - Residential Not Ready 9/19/2023 9/19/2023 09/19/2023
Misc
Corrective Action Required
09/19/2023
For finished basement only. Inspection denied no fireblocking performed
All Rough Inspection - Residential Passed 9/21/2023 9/21/2023 09/21/2023
Misc
Resolved
09/21/2023
For finished basement only. Inspection denied no fireblocking performed
Misc
Informational
09/21/2023
Basement finish inspected
Sidewalk Inspection Partial 10/23/2023 10/23/2023 10/23/2023
Misc
Informational
10/31/2022
10-31-22 RH. Nothing is formed up and aggregate is not placed or compacted. 10-23-23 Dustin A, SW is formed in back of property. Aggregate is compacted and slopes are in compliance . approved to pour 10-30-23 Dustin A, Sw is poured. Slopes are in compliance. Cannot pass until forms are pulled
Sidewalk Inspection Passed 10/31/2023 10/31/2023 11/07/2023
Misc
Informational
10/30/2023
10-31-22 RH. Nothing is formed up and aggregate is not placed or compacted. 10-23-23 Dustin A, SW is formed in back of property. Aggregate is compacted and slopes are in compliance . approved to pour 10-30-23 Dustin A, Sw is poured. Slopes are in compliance. Cannot pass until forms are pulled 11-7-23 Dustin A , Sw forms are pulled. SW in rear of house on redbuck has passsed
Sidewalk Inspection Passed 11/7/2023 11/7/2023 11/07/2023
Plot Plan Inspection Passed 11/20/2023 11/20/2023 11/20/2023
Occupancy Inspection - Codes Residential Failed 12/29/2023 12/29/2023 12/29/2023
Misc
Corrective Action Required
12/29/2023
-Provide contrasting address numbers -Maintain erosion control -Missing splash blocks -No sod installed -Missing sump pump extension -Missing stairs at patio -Adjust self closing hinges at garage door -Provide balusters at garage stairs -Label non GFCI's in garage -Top stair leading to basement exceeds 3/8 inch difference
Piers/Caissons Inspection - Residential Passed 01/04/2024
Misc
Resolved
01/04/2024
Piers incorrect size.
Occupancy Inspection - Codes Residential Ready for Temp CO 1/4/2024 1/4/2024 01/04/2024
Misc
Corrective Action Required
12/29/2023
- splash blocks and sump pump discharge to extend 36” from foundation -No sod installed -will check water meter at time of sod.
Erosion Control Inspection Residential Passed 05/23/2024
DCM3 ESC REQUIRED 2 DAY
Resolved
05/23/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Misc
Resolved
05/23/2024
No further inspections until overgrown vegetation is addressed
Occupancy Inspection - Codes Residential Full C of O 5/23/2024 05/23/2024
Misc
Resolved
05/23/2024
- splash blocks and sump pump discharge to extend 36” from foundation -No sod installed -will check water meter at time of sod.
Documents & Images
Date Uploaded File Type Document Name
10/12/2022 76 Excise Tax_000283
10/12/2022 76 Ap_000284
10/17/2022 Permit Codes Residential Plan Review
10/18/2022 Plans approved plot plan
10/24/2022 Corrected Ap SVF 76_000297
10/24/2022 Approved Plans Approved Drawings
10/24/2022 Permit Codes Residential Plan Review
10/25/2022 Permit DS Building Permit
10/25/2022 Receipt Receipt for transaction:2022-008494
10/27/2022 M L Crose 2306 SW Serena Pl LSMO Summit View Farms Lot 76 3rd Party Footing Inspection Report 10-26-22
10/28/2022 Letter Stop Work Order
10/31/2022 Letter INSPECTION SUMMARY
10/31/2022 Letter INSPECTION SUMMARY
11/05/2022 Receipt Receipt for transaction:2022-008731
12/12/2022 Letter INSPECTION SUMMARY
12/12/2022 Letter INSPECTION SUMMARY
01/05/2023 Letter INSPECTION SUMMARY
01/05/2023 Letter INSPECTION SUMMARY
01/05/2023 Letter INSPECTION SUMMARY
01/05/2023 Letter INSPECTION SUMMARY
01/10/2023 Letter INSPECTION SUMMARY
01/10/2023 Letter INSPECTION SUMMARY
01/10/2023 Letter INSPECTION SUMMARY
04/14/2023 Letter INSPECTION SUMMARY
04/17/2023 Bill Kenney 2306 SW Serena Place LSMO Deck Support Post Pier Inspection Report 4-14-23
04/17/2023 Pier Inspection 2306 SW Serena Place LSMO Deck Support Post Pier Inspection Report 4-14-23
06/14/2023 Bill Kenney 2306 SW Serena Place LSMO Deck Framing Issue Inspection Report 5-22-23
06/16/2023 Letter INSPECTION SUMMARY
06/16/2023 Letter INSPECTION SUMMARY
06/16/2023 Letter INSPECTION SUMMARY
06/19/2023 Letter INSPECTION SUMMARY
06/19/2023 Letter INSPECTION SUMMARY
07/01/2023 2306 SW Serena Framing Report AINSWORTH
07/01/2023 2306 SW Serena Rough-In Response SDC
07/03/2023 Letter INSPECTION SUMMARY
07/05/2023 Letter Stop Work Order
07/05/2023 Letter Stop Work Order
07/05/2023 Letter INSPECTION SUMMARY
07/05/2023 Letter INSPECTION SUMMARY
07/10/2023 Letter INSPECTION SUMMARY
07/10/2023 Letter INSPECTION SUMMARY
07/11/2023 Receipt Receipt for transaction:2023-005332
07/11/2023 Letter INSPECTION SUMMARY
07/12/2023 Letter INSPECTION SUMMARY
07/27/2023 Letter INSPECTION SUMMARY
07/28/2023 Letter INSPECTION SUMMARY
09/11/2023 SVF 76 Finished Basement
09/13/2023 PRRES20225143 Scope of Work09132023
09/18/2023 Receipt Receipt for transaction:2023-007110
09/18/2023 Approved Plans APPROVED BASEMENT FINISH
09/19/2023 Letter INSPECTION SUMMARY
09/19/2023 Letter INSPECTION SUMMARY
09/20/2023 Receipt Receipt for transaction:2023-007176
09/21/2023 Letter INSPECTION SUMMARY
10/23/2023 Letter INSPECTION SUMMARY
10/30/2023 Letter INSPECTION SUMMARY
10/30/2023 Letter INSPECTION SUMMARY
11/07/2023 Letter INSPECTION SUMMARY
11/07/2023 Letter INSPECTION SUMMARY
11/07/2023 Letter INSPECTION SUMMARY
11/20/2023 Letter INSPECTION SUMMARY
12/29/2023 Letter INSPECTION SUMMARY
01/04/2024 Letter INSPECTION SUMMARY
01/04/2024 Certificate/License Codes Temporary Certificate of Occupancy
01/04/2024 Receipt Receipt for transaction:2024-000070
05/23/2024 Letter INSPECTION SUMMARY
05/23/2024 Letter Field Certificate of Occupancy
05/23/2024 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home