Summary
PRRES20220216
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE. FINISHED/UNFINISHED BASEMENT. COVERED DECK.
01/18/2022
01/25/2022
07/24/2022
11/03/2022
Locations
Contacts
SAB CONSTRUCTION INC, Address:PO BOX 942, Phone:(816) 524-3855  
Joseph Matthew Schartz, Address:PO Box 942, Phone:(816) 524-3855  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
GARRISON PLUMBING, Address:15430 S MAHAFFIE ST STE 102, Phone:(913) 768-1311  
TEAGUE ELECTRIC CONSTRUCTION INC, Address:12425 W 92ND ST, Phone:(913) 529-4600  
JIM@SABHOMES.COM  
Brandon Bamesberger, Address:PO Box 942  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 01/25/2022
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 01/25/2022
8331507-Sewer Connection Fee $420.00 $420.00 Paid 01/25/2022
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 01/25/2022
8350015-Water Meter Fee $479.24 $479.24 Paid 01/25/2022
9110078-Valuation Fee New Single Family $1,040.08 $1,040.08 Paid 01/25/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 07/25/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 2/3/2022 02/03/2022
Misc
Informational
02/03/2022
3rd party inspection
Erosion Control Inspection Residential Failed 2/10/2022 2/10/2022 02/10/2022
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
02/10/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Underslab Plumbing Inspection - Residential Failed 3/22/2022 3/22/2022 03/22/2022
Misc
Corrective Action Required
03/22/2022
inspection denied due to lack of erosion control
Erosion Control Inspection Residential Failed 3/22/2022 03/22/2022
DCM3 ESC REQUIRED 2 DAY
Resolved
03/22/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM5 ESC INSP DENIED
Corrective Action Required
03/22/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. -silt fence -gravel filter
Piers/Caissons Inspection - Residential Partial 4/1/2022 (1:15) 4/1/2022 04/01/2022
Misc
Informational
04/01/2022
okay to pour 3 piers plans need to be revised to show 4th pier being replaced and deck landing on foundation wall
Electrical Service Inspection Passed 6/17/2022 6/17/2022 06/17/2022
Gas Service Inspection - Residential Passed 6/17/2022 6/17/2022 06/17/2022
All Rough Inspection - Residential Not Ready 6/17/2022 6/17/2022 06/17/2022
Misc
Corrective Action Required
06/17/2022
inspection denied -no city stamped plans on site do not reschedule until all windows and doors are installed. Mitchell Schwarz 06/17/2022 8:57 AM
All Rough Inspection - Residential Failed 6/20/2022 6/20/2022 06/20/2022
Misc
Resolved
06/20/2022
inspection denied -no city stamped plans on site do not reschedule until all windows and doors are installed. Mitchell Schwarz 06/17/2022 8:57 AM
Misc
Corrective Action Required
06/20/2022
-anchor bolts at pfh to be in the middle 1/3 of sill plate -address over notched stud W garage wall -stud packs to plans under beam in garage -missing 2x12 with lvl and hanger above entry -entry/garage wall fireblocking to ceiling space -complete bath fan -address studs over notched at master Closet -fire block ceiling line in master closet -address ceiling joist to rafter connections in master -address rafter landing on 2x4 turned on side throughout -address holes drilled less than 2” from each other in ceiling joist see walk in pantry -provide viewing for cover patio roof framing -provide lateral bracing for 2x12 over rear slider -address over notched hip rafter above dining -fireblock vertical to horizontal every 10’ in basement -addresses over notched studs for dwv in bed 4 closet -fire block pex into basement bath furr down (see bed 4 closet) -open dwv pipe in unfinished area -anchor bolts to be in the middle 1/3 in basement and stairwell sill plate
Sewer Service Inspection - R Partial 6/22/2022 (9:15) 6/22/2022 06/22/2022
Misc
Corrective Action Required
06/22/2022
-address under mined footing -pipe is good
Water Service Inspection - R Passed 6/23/2022 (9:15) 6/23/2022 06/23/2022
All Rough Inspection - Residential Failed 6/28/2022 6/28/2022 06/28/2022
Misc
Corrective Action Required
06/20/2022
-address over notched stud W garage -address studs over notched at master Closet -address rafter landing on 2x4 turned on side throughout -address holes drilled less than 2” from each other in ceiling joist see walk in pantry -provide viewing for cover patio roof framing -provide lateral bracing for 2x12 over rear slider -address over notched hip rafter above dining -fireblock vertical to horizontal every 10’ in basement -addresses over notched studs for dwv in bed 4 closet -anchor bolts to be in the middle 1/3 in basement and stairwell sill plate -address underslab plumbing still not passed
All Rough Inspection - Residential Failed 7/15/2022 7/15/2022 07/15/2022
Misc
Corrective Action Required
06/28/2022
-address over notched stud W garage -address studs over notched at master Closet -address rafter landing on 2x4 turned on side throughout -address holes drilled less than 2” from each other in ceiling joist see walk in pantry -provide viewing for cover patio roof framing -provide lateral bracing for 2x12 over rear slider -address over notched hip rafter above dining -fireblock vertical to horizontal every 10’ in basement -addresses over notched studs for dwv in bed 4 closet -anchor bolts to be in the middle 1/3 in basement and stairwell sill plate -address underslab plumbing still not passed inspection denied letter still not submited from builder for under slab and dye test still not performed per our discussion.
Underslab Plumbing Inspection - Residential Passed 7/22/2022 7/22/2022 07/22/2022
Misc
Resolved
07/22/2022
inspection denied due to lack of erosion control
Informational
07/22/2022
dye test performed, letters uploaded regaurding covered underslab plumbing
All Rough Inspection - Residential Passed 7/25/2022 7/25/2022 07/25/2022
Misc
Resolved
07/25/2022
-address over notched stud W garage -address studs over notched at master Closet -address rafter landing on 2x4 turned on side throughout -address holes drilled less than 2” from each other in ceiling joist see walk in pantry -provide viewing for cover patio roof framing -provide lateral bracing for 2x12 over rear slider -address over notched hip rafter above dining -fireblock vertical to horizontal every 10’ in basement -addresses over notched studs for dwv in bed 4 closet -anchor bolts to be in the middle 1/3 in basement and stairwell sill plate -address underslab plumbing still not passed inspection denied letter still not submited from builder for under slab and dye test still not performed per our discussion.
Driveway Inspection Partial 9/12/2022 9/12/2022 09/12/2022
Misc
Informational
09/12/2022
9-12-22 RH. Driveway is formed up and aggregate is placed and compacted.
Driveway Inspection Passed 9/19/2022 9/19/2022 09/16/2022
Misc
Informational
09/12/2022
9-12-22 RH. Driveway is formed up and aggregate is placed and compacted. 9-16-22 RH. Driveway meets LS and ADA specification.
Occupancy Inspection - Codes Residential Failed 10/21/2022 10/21/2022 10/21/2022
Misc
Corrective Action Required
10/21/2022
-upload engineer letter for undermined footing for sewer -address pier inspection no passed -final grade and sod (grade to plot plan) -gutters -splash blocks and sump pump discharge to extend 36” from foundation -provide permanent address and illuminate -check water meter at time of sod -open ground at entry bath outlet -gravel for basement window wells. Step to Ladder not to be greater than 18” -hardware at rear slider -land at rear deck stairs to extend 36” in the direction of travel -seal all exterior penetrations
Erosion Control Inspection Residential Passed 11/3/2022 11/3/2022 11/03/2022
DCM5 ESC INSP DENIED
Resolved
11/03/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. -silt fence -gravel filter
Sewer Service Inspection - R Passed 11/3/2022 11/3/2022 11/03/2022
Misc
Informational
11/03/2022
SEE ENGINEER REPORT CHRISTOPHER L SAATHOTH 11/1/22
Piers/Caissons Inspection - Residential Passed 11/03/2022
Misc
Resolved
11/03/2022
okay to pour 3 piers plans need to be revised to show 4th pier being replaced and deck landing on foundation wall
Plot Plan Inspection Passed 11/3/2022 11/3/2022 11/03/2022
Occupancy Inspection - Codes Residential Full C of O 11/3/2022 11/3/2022 11/03/2022
Misc
Resolved
11/03/2022
Documents & Images
Date Uploaded File Type Document Name
01/18/2022 HF047 - Air Combustion
01/18/2022 HF047-excise_tax
01/25/2022 Permit Codes Residential Plan Review
01/25/2022 Plot Plan APPROVED PLOT PLAN
01/25/2022 hf047-permit_app_updated
01/25/2022 Approved Plans APPROVED DRAWINGS
01/25/2022 Permit Codes Residential Plan Review
01/25/2022 Permit DS Building Permit
01/25/2022 Receipt Receipt for transaction:2022-000423
02/03/2022 2032 SW Wheatfield Ct LSMO Hook Farms Lot 47 Footing Inspection Report 2-1-22
02/03/2022 Letter INSPECTION SUMMARY
02/10/2022 Letter INSPECTION SUMMARY
03/22/2022 Letter INSPECTION SUMMARY
03/22/2022 Letter INSPECTION SUMMARY
03/30/2022 HF43 - Basement Finish App
04/01/2022 Letter INSPECTION SUMMARY
06/17/2022 Letter INSPECTION SUMMARY
06/20/2022 Letter INSPECTION SUMMARY
06/20/2022 Letter INSPECTION SUMMARY
06/20/2022 Letter INSPECTION SUMMARY
06/22/2022 Letter INSPECTION SUMMARY
06/23/2022 Letter INSPECTION SUMMARY
06/28/2022 Letter INSPECTION SUMMARY
07/13/2022 2032 SW Wheatfield court
07/15/2022 Letter INSPECTION SUMMARY
07/18/2022 2032 SW Wheatfield court
07/18/2022 DW FRAMING INSPECTION RESPONSE Solaia 2032 SW Wheatfield Ct HF047 7-15-22
07/18/2022 HF47 Under Slab Plumbing
07/22/2022 Letter INSPECTION SUMMARY
07/25/2022 Receipt Receipt for transaction:2022-006035
07/25/2022 Letter INSPECTION SUMMARY
09/12/2022 Letter INSPECTION SUMMARY
09/16/2022 Letter INSPECTION SUMMARY
10/21/2022 Letter INSPECTION SUMMARY
11/02/2022 DW STRUCTURAL REPORTr[1]
11/02/2022 DW STRUCTURAL REPORTr1__
11/03/2022 DW STRUCTURAL REPORTr[1]
11/03/2022 Letter INSPECTION SUMMARY
11/03/2022 Letter INSPECTION SUMMARY
11/03/2022 Letter INSPECTION SUMMARY
11/03/2022 Letter INSPECTION SUMMARY
11/03/2022 Letter Field Certificate of Occupancy
11/03/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home