Summary
PRRES20215798
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE. WALKOUT BASEMENT. SUSPENDED SLAB. COVERED DECK. STOP WORK ORDER generated on 07/11/2023 12:00 AM by username 'Mitchell Schwarz'. STOP WORK ORDER removed on 07/20/2023 12:00 AM by username 'Mitchell Schwarz'. STOP WORK ORDER generated on 07/20/2023 12:00 AM by username 'Mitchell Schwarz'. STOP WORK ORDER removed on 08/10/2023 12:00 AM by username 'Mark Harding'.
11/05/2021
12/02/2021
05/08/2022
05/21/2024
Locations
Contacts
D AND D BUILDING INC, Address:PO BOX 7014, Phone:(816) 491-2125  
Kevin Stallings, Address:1100 NE Delta School Rd, Phone:(816) 491-2125  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
TEAGUE ELECTRIC CONSTRUCTION INC, Address:12425 W 92ND ST, Phone:(913) 529-4600  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
DANDDBUILDINGCO@GMAIL.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $570.00 $570.00 Paid 12/02/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 12/02/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 12/02/2021
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 12/02/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 12/02/2021
9110078-Valuation Fee New Single Family $1,087.60 $1,087.60 Paid 12/02/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 02/08/2024
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 02/08/2024
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 02/08/2024
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 02/08/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 12/10/2021 (3:30) 12/10/2021 12/10/2021
Misc
Corrective Action Required
12/10/2021
Footing inspection denied- House plans do not Match approved plot plan. Resubmit correct plot plan with rear garage for review showing correct foundation detail, retaining g wall and grade. Do not pour footing.
Footing Inspection - Residential Failed 12/14/2021 (3:00) 12/14/2021 12/14/2021
Misc
Corrective Action Required
12/10/2021
Footing inspection denied- House plans do not Match approved plot plan. Resubmit correct plot plan with rear garage for review showing correct foundation detail, retaining g wall and grade. Do not pour footing.
Misc
Corrective Action Required
12/14/2021
INSPECTION DENIED -revised plot plan needs to be approved before inspection -revised plans showing retaining wall need to be uploaded and approved before inspection DO NOT POUR Mitchell Schwarz 12/14/2021 2:03 PM
Footing Inspection - Residential Passed 12/16/2021 12/16/2021
Misc
Resolved
12/16/2021
Footing inspection denied- House plans do not Match approved plot plan. Resubmit correct plot plan with rear garage for review showing correct foundation detail, retaining g wall and grade. Do not pour footing.
Misc
Resolved
12/16/2021
INSPECTION DENIED -revised plot plan needs to be approved before inspection -revised plans showing retaining wall need to be uploaded and approved before inspection DO NOT POUR Mitchell Schwarz 12/14/2021 2:03 PM
Sewer Service Inspection - R Passed 1/3/2022 (1:00) 1/3/2022 01/03/2022
Water Service Inspection - R Passed 1/10/2022 (1:00) 1/10/2022 01/10/2022
Erosion Control Inspection Residential Failed 1/13/2022 01/13/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
01/13/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Underslab Plumbing Inspection - Residential Failed 1/13/2022 1/13/2022 01/13/2022
Misc
Corrective Action Required
01/13/2022
inspection denied -lack of erosion control -no premises identification
Erosion Control Inspection Residential Failed 1/21/2022 01/21/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
01/13/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
01/21/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Mitchell Schwarz 01/21/2022 9:24 AM
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
01/21/2022
STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO INSPECTION(S) BEING PERFORMED.
Underslab Plumbing Inspection - Residential Not Ready 2/8/2022 2/8/2022 02/08/2022
Misc
Corrective Action Required
01/13/2022
inspection denied -no premises identification
Erosion Control Inspection Residential Failed 2/8/2022 2/8/2022 02/08/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
01/21/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
01/21/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Mitchell Schwarz 01/21/2022 9:24 AM
DCM6 ESC INSP DENIED STREET CLEAN UP
Resolved
02/08/2022
STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO INSPECTION(S) BEING PERFORMED.
Misc
Corrective Action Required
02/08/2022
EROSION CONTROL AT BACK OF LOT NOT IN COMPLIANCE
Underslab Plumbing Inspection - Residential Passed 2/11/2022 2/11/2022 02/11/2022
Misc
Resolved
02/11/2022
inspection denied -no premises identification
Erosion Control Inspection Residential Passed 2/11/2022 2/11/2022 02/11/2022
DCM2 ESC DEFICIENT INSTALLATION
Resolved
02/11/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
DCM3 ESC REQUIRED 2 DAY
Resolved
02/11/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Mitchell Schwarz 01/21/2022 9:24 AM
Misc
Resolved
02/11/2022
EROSION CONTROL AT BACK OF LOT NOT IN COMPLIANCE
Suspended Slab Inspection Failed 6/30/2022 (3:30) 6/30/2022 07/01/2022
Misc
Corrective Action Required
06/30/2022
provide plans/detail for suspended slab garage
Suspended Slab Inspection Passed 7/1/2022 07/01/2022
Misc
Resolved
07/01/2022
provide plans/detail for suspended slab garage
Piers/Caissons Inspection - Residential Passed 1/4/2023 (1:30) 1/4/2023 01/04/2023
All Rough Inspection - Residential Not Ready 4/20/2023 4/20/2023 04/20/2023
Misc
Corrective Action Required
04/20/2023
INSPECTION DENIED No city stamped plans on site
Electrical Service Inspection Failed 4/28/2023 4/28/2023 04/28/2023
Misc
Corrective Action Required
04/28/2023
Uncover covered electrical and unfinish spaces
Gas Service Inspection - Residential Failed 4/28/2023 4/28/2023 04/28/2023
Misc
Corrective Action Required
04/28/2023
Complete gas line instal at fireplace
Occupancy Inspection - Codes Residential Failed 4/28/2023 04/28/2023
Misc
Corrective Action Required
04/28/2023
-anchor bolts in garage and basement to be tightly secured -furr out and fireblock for dwv in laundry -secure all vertical dwv 2” in diameter or less -nail top plate to header for cspf in breakfast -uncover covered deck for inspection -complete fireplace installation -connect and secure gas line at fireplace -roof supports not to plans -fire block into furr down at master bed entry -missing nails in hangers above master -missing top plate under header for cspf in master -missing nails in stud shoes at master bath for dwv -address header size in master bath not to plans -tighten all bolts in living room/kitchen -fireblock wall to ceiling space at butlers pantry/stairs -secure 2” dwv in stairwell -provide engineering floor joist city stamped plans on site -fire block nw family room wall to ceiling space -remove all unfinished area electrical cover plates for inspection -fire block bed 4 closet nw corner to ceiling space -incorrect hanger for lvl above bed 4 -address lvl’s drilled through above bed 4 per 502.8.2 -fire blocking must be of approved materials (see vertical to horizontal and top of furred out walls) -fire block Se bed 3 closet to ceiling space -address I joist but above bed bath sinks for drain above -fireblock above basement patio door -fireblock furr out wall into furr down in craft room -provide support for furr down in family room to floor joists above -identify column size in basement -cspf exterior nailing not correct -
All Rough Inspection - Residential Failed 4/28/2023 4/28/2023 04/28/2023
Misc
Resolved
04/28/2023
INSPECTION DENIED No city stamped plans on site
Misc
Corrective Action Required
04/28/2023
-anchor bolts in garage and basement to be tightly secured -furr out and fireblock for dwv in laundry -secure all vertical dwv 2” in diameter or less -nail top plate to header for cspf in breakfast -uncover covered deck for inspection -complete fireplace installation -connect and secure gas line at fireplace -roof supports not to plans -fire block into furr down at master bed entry -missing nails in hangers above master -missing top plate under header for cspf in master -missing nails in stud shoes at master bath for dwv -address header size in master bath not to plans -tighten all bolts in living room/kitchen -fireblock wall to ceiling space at butlers pantry/stairs -secure 2” dwv in stairwell -provide engineering floor joist city stamped plans on site -fire block nw family room wall to ceiling space -remove all unfinished area electrical cover plates for inspection -fire block bed 4 closet nw corner to ceiling space -incorrect hanger for lvl above bed 4 -address lvl’s drilled through above bed 4 per 502.8.2 -fire blocking must be of approved materials (see vertical to horizontal and top of furred out walls) -fire block Se bed 3 closet to ceiling space -address I joist but above bed bath sinks for drain above -fireblock above basement patio door -fireblock furr out wall into furr down in craft room -provide support for furr down in family room to floor joists above -identify column size in basement -cspf exterior nailing not correct -
Gas Service Inspection - Residential Not Ready 5/8/2023 5/8/2023 05/08/2023
Misc
Corrective Action Required
04/28/2023
Complete gas line instal at fireplace
Electrical Service Inspection Passed 5/8/2023 5/8/2023 05/08/2023
Misc
Resolved
05/08/2023
Uncover covered electrical and unfinish spaces
All Rough Inspection - Residential Failed 5/8/2023 5/8/2023 05/08/2023
Misc
Corrective Action Required
04/28/2023
-anchor bolts in garage and basement to be tightly secured -secure all vertical dwv 2” in diameter or less see laundry -uncover covered deck for inspection (no plans on site to check framing, not completely uncovered) -complete fireplace installation (secure at front face -connect and secure gas line at fireplace -roof supports not to plans (no plans on site to check) -missing nails in hangers above master -missing nails in stud shoes at master bath for dwv -address header size in master bath not to plans (no plans on site to check item) -secure 2” dwv in stairwell -provide engineering floor joist city stamped plans on site and uploaded -fire block bed 4 closet nw corner to ceiling space(no plans to identify bedroom) -incorrect hanger for lvl above bed 4 (no plans to identify bedroom) -address lvl’s drilled through above bed 4 per 502.8.2 (no plans on site to identify bedroom) -fire blocking must be of approved materials (see vertical to horizontal and top of furred out walls) -fire block Se bed 3 closet to ceiling space(no plans on site to identify bedroom) -address I joist but above bed bath sinks for drain above -fireblock above basement patio door(not approved material) -fireblock furr out wall into furr down in craft room -provide support for furr down in family room to floor joists above -identify column size in basement -cspf exterior nailing not correct
Gas Service Inspection - Residential Not Ready 5/10/2023 5/10/2023 05/10/2023
Misc
Corrective Action Required
05/08/2023
Complete gas line install at fireplace still not completed
All Rough Inspection - Residential Failed 5/10/2023 5/10/2023 05/10/2023
Misc
Corrective Action Required
05/08/2023
-identify hash lines appearing to be lib bracing on plans -secure all vertical dwv 2” in diameter or less see laundry -connect and secure gas line at fireplace (gas line not completed) -roof supports not to plans (no plans on site to check) roof supports landing on fire place/ entry wall. -missing nails in hangers above master -missing nails in stud shoes at master bath for dwv -address header size in master bath not to plans -provide engineering floor joist city stamped plans on site and uploaded (not uploaded or stamped) -incorrect hanger for lvl above bed 4, missing nails in hanger above bed 4 -address lvl’s drilled through above bed 4 per 502.8.2 -fire blocking must be of approved materials (see vertical to horizontal and top of furred out walls) -address I joist above basement bed bath sinks for cut drain above -fireblock above basement patio door(not approved material) -fireblock furr out wall into furr down in craft room -provide support for furr down in family room to floor joists above -cspf exterior nailing not correct -proper hold downs for cspf in mater bed where cantilever prohibits proper nailing
Gas Service Inspection - Residential Passed 5/31/2023 5/31/2023 05/31/2023
Misc
Resolved
05/31/2023
Complete gas line install at fireplace still not completed
All Rough Inspection - Residential Failed 5/31/2023 5/31/2023 05/31/2023
Misc
Corrective Action Required
05/10/2023
-address header size in master bath not to plans (engineer) -provide engineering floor joist city stamped plans on site and uploaded (not uploaded or stamped) -address lvl’s drilled through above bed 4 per 502.8.2 (engineers) -fire blocking must be of approved materials (see vertical to horizontal and top of furred out walls) -address I joist above basement bed bath sinks for cut drain above -fireblock above basement patio door(not approved material) -fireblock furr out wall into furr down in craft room -provide support for furr down in family room to floor joists above
All Rough Inspection - Residential Not Ready 6/6/2023 6/6/2023 06/06/2023
Misc
Corrective Action Required
05/31/2023
-address header size in master bath not to plans (engineer) -provide engineering floor joist city stamped plans on site and uploaded (not uploaded or stamped) -address lvl’s drilled through above bed 4 per 502.8.2 (engineers) -address I joist above basement bed bath sinks for cut drain above -fireblock -provide support for furr down in family room to floor joists above
Piers/Caissons Inspection - Residential Failed 6/27/2023 06/27/2023
Misc
Corrective Action Required
06/27/2023
Piers poured without inspection provide 3rd party inspection report within 48hr of pouring.
All Rough Inspection - Residential Failed 7/5/2023 7/5/2023 07/05/2023
Misc
Corrective Action Required
06/06/2023
-address header size in master bath not to plans (engineer) -provide engineering floor joist city stamped plans on site and uploaded (not uploaded or stamped) -address lvl’s drilled through above bed 4 per 502.8.2 (engineers) -address I joist above basement bed bath sinks for cut drain above -fireblock -provide support for furr down in family room to floor joists above
Misc
Corrective Action Required
07/05/2023
-Provide city stamped plans on site
Piers/Caissons Inspection - Residential Failed - Stop Work 7/11/2023 07/11/2023
Misc
Corrective Action Required
06/27/2023
Piers poured without inspection provide 3rd party inspection report within 48hr of pouring.
Misc
Corrective Action Required
07/11/2023
NO THIRD PARTY INSPECTION PERFORMED, STOP WORK ISSUED. Mitchell Schwarz 07/11/2023 7:33 AM
Piers/Caissons Inspection - Residential Passed 7/20/2023 07/20/2023
Misc
Resolved
07/20/2023
Piers poured without inspection provide 3rd party inspection report within 48hr of pouring.
Misc
Resolved
07/20/2023
NO THIRD PARTY INSPECTION PERFORMED, STOP WORK ISSUED. Mitchell Schwarz 07/11/2023 7:33 AM
Misc
Informational
07/20/2023
Depth of piers verified by digging down along side of pier.
All Rough Inspection - Residential Failed - Stop Work 7/20/2023 7/20/2023 07/20/2023
Misc
Corrective Action Required
07/05/2023
-address header size in master bath not to plans (engineer) -provide engineering floor joist city stamped plans on site and uploaded (not uploaded or stamped) -address lvl’s drilled through above bed 4 per 502.8.2 (engineers) -address I joist above basement bed bath sinks for cut drain above -fireblock -provide support for furr down in family room to floor joists above
Misc
Corrective Action Required
07/05/2023
-Provide city stamped plans on site
Misc
Corrective Action Required
07/20/2023
Stop work issued until outstanding items are addressed
All Rough Inspection - Residential Failed - Stop Work 8/4/2023 8/4/2023 08/04/2023
Misc
Resolved
08/10/2023
-provide engineering floor joist city stamped plans on site and uploaded (not uploaded or stamped) -address lvl’s drilled through above bed 4 per 502.8.2 (engineers) -address I joist above basement bed bath sinks cut for drain above met with Tom on july 25th trim, cabinets, and island was installed under a stop construction. Engineer was contacted and the wall above the cut joist appears to be a bearing wall. Engineer is to supply an updated I joist plan. These items need to be addressed before any further work can be performed. -Mitchell Schwarz 8/4/23
Misc
Resolved
08/10/2023
-Provide city stamped plans on site
Misc
Resolved
08/10/2023
Stop work issued until outstanding items are addressed
Erosion Control Inspection Residential Failed 8/4/2023 08/04/2023
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
08/04/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -maintain silt fence -maintain overgrown vegetation
All Rough Inspection - Residential Passed 8/10/2023 08/10/2023
Misc
Resolved
08/10/2023
-provide engineering floor joist city stamped plans on site and uploaded (not uploaded or stamped) -address I joist above basement bed bath sinks cut for drain above met with Tom on july 25th trim, cabinets, and island was installed under a stop construction. Engineer was contacted and the wall above the cut joist appears to be a bearing wall. Engineer is to supply an updated I joist plan. These items need to be addressed before any further work can be performed. -Mitchell Schwarz 8/4/23
Misc
Resolved
08/10/2023
-Provide city stamped plans on site
Misc
Resolved
08/10/2023
Stop work issued until outstanding items are addressed
Driveway Inspection Passed 8/14/2023 08/16/2023
Misc
Informational
08/14/2023
8-14-23 BR Driveway is formed up and aggregate is place and compacted ready for concrete. 8-16-23 BR Driveway is constructed to LS specification.
Erosion Control Inspection Residential Failed 9/22/2023 09/22/2023
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
08/04/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -maintain silt fence -maintain overgrown vegetation
Erosion Control Inspection Residential Partial 9/27/2023 9/27/2023 09/27/2023
DCM3 ESC REQUIRED 2 DAY
Resolved
09/27/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -maintain silt fence -maintain overgrown vegetation
Misc
Corrective Action Required
09/27/2023
Grading being performed
Plot Plan Inspection Passed 12/20/2023 12/20/2023
Occupancy Inspection - Codes Residential Failed 12/20/2023 12/20/2023
Misc
Corrective Action Required
12/20/2023
-address pending sidewalk inspection -pay all fees -obtain issued lawn irrigation permit -arc fault protection for kitchen hood -spark ring for kitchen backsplash outlets where as required -spark ring for outlet above fireplace -provide security screws at basement patio door (2 3” screws per hinge and strike plate) -deck post over notched for post to beam connection -missing smoke detector above water heaters (Will check smoke detectors at time of installation) -label all non GFCI outlets in unfinished spaces
Occupancy Inspection - Codes Residential Failed 2/1/2024 2/1/2024 02/01/2024
Misc
Corrective Action Required
12/20/2023
-address pending sidewalk inspection -pay all fees -obtain issued lawn irrigation permit
Sidewalk Inspection Passed 11/8/2023 11/8/2023 02/08/2024
Misc
Informational
11/08/2023
11-8-23 Dustin A, SW is formed and aggregate is compacted. Slopes are in compliance approved to pour. 2-8-24 Dustin A, Sw is poured . Slopes are in compliance. Passed
Sidewalk Inspection Passed 2/8/2024 2/8/2024 02/08/2024
Misc
Informational
02/08/2024
2-8-24 Dustin A, SW is poured to city specs. Slopes are in compliance. Passed
Sidewalk Inspection Passed 2/8/2024 2/8/2024 02/08/2024
Misc
Informational
02/08/2024
2-8-24 Dustin A, SW is poured to city specs. Slopes are in compliance. Passed
Erosion Control Inspection Residential Passed 05/21/2024
Misc
Resolved
05/21/2024
Grading being performed
Occupancy Inspection - Codes Residential Full C of O 5/21/2024 05/21/2024
Misc
Resolved
05/21/2024
-address pending sidewalk inspection -pay all fees -obtain issued lawn irrigation permit
Documents & Images
Date Uploaded File Type Document Name
11/05/2021 Final_2021_08_02_SlabDes_LSMO_D&D 39ww
11/08/2021 39ww application
11/09/2021 Permit Codes Residential Plan Review
11/19/2021 Plot Plan APPROVED PLOT PLAN
11/30/2021 Approved Plans APPROVED DRAWINGS
11/30/2021 Permit Codes Residential Plan Review
12/02/2021 Permit DS Building Permit
12/02/2021 Receipt Receipt for transaction:2021-009066
12/10/2021 Letter INSPECTION SUMMARY
12/14/2021 WW 39 FINAL REV2
12/14/2021 Letter INSPECTION SUMMARY
12/16/2021 Approved Plans APPROVED DRAWINGS
12/16/2021 Plot Plan APPROVED PLOT PLAN
12/16/2021 Letter INSPECTION SUMMARY
01/03/2022 Letter INSPECTION SUMMARY
01/10/2022 Letter INSPECTION SUMMARY
01/13/2022 Letter INSPECTION SUMMARY
01/13/2022 Letter INSPECTION SUMMARY
01/21/2022 Letter INSPECTION SUMMARY
02/08/2022 Letter INSPECTION SUMMARY
02/08/2022 Letter INSPECTION SUMMARY
02/11/2022 Letter INSPECTION SUMMARY
02/23/2022 Letter INSPECTION SUMMARY
07/01/2022 Letter INSPECTION SUMMARY
07/01/2022 Letter INSPECTION SUMMARY
07/01/2022 Letter INSPECTION SUMMARY
11/18/2022 Letter Codes 140 Day Letter
12/28/2022 Letter Codes 180 Day Letter
01/04/2023 Letter Codes Residential Plan Review
01/04/2023 Letter INSPECTION SUMMARY
04/20/2023 Letter INSPECTION SUMMARY
04/28/2023 Letter INSPECTION SUMMARY
04/28/2023 Letter INSPECTION SUMMARY
04/28/2023 Letter INSPECTION SUMMARY
04/28/2023 Letter INSPECTION SUMMARY
05/10/2023 Letter INSPECTION SUMMARY
05/10/2023 Letter INSPECTION SUMMARY
05/31/2023 Letter INSPECTION SUMMARY
05/31/2023 Letter INSPECTION SUMMARY
06/06/2023 Letter INSPECTION SUMMARY
06/06/2023 Letter INSPECTION SUMMARY
06/06/2023 Letter INSPECTION SUMMARY
06/06/2023 Letter INSPECTION SUMMARY
06/27/2023 Letter INSPECTION SUMMARY
06/28/2023 IMG_0544
06/28/2023 IMG_0545
06/28/2023 IMG_0546
06/28/2023 IMG_0547
06/28/2023 IMG_0548
07/05/2023 Letter INSPECTION SUMMARY
07/11/2023 Letter Stop Work Order
07/12/2023 Stop work posted
07/20/2023 Letter INSPECTION SUMMARY
07/20/2023 Letter Stop Work Order
07/20/2023 Letter Stop Work Order
07/24/2023 1609 SW 27th St - Comment Response
08/02/2023 1609 SW 27th St, Lee's Summit - Comment Response, Addtl Calcs
08/04/2023 Letter Stop Work Order
08/04/2023 Letter INSPECTION SUMMARY
08/04/2023 IMG_0857
08/07/2023 Approved Plans APPROVED JOIST DRAWING
08/10/2023 Letter INSPECTION SUMMARY
08/14/2023 Letter INSPECTION SUMMARY
08/16/2023 Letter INSPECTION SUMMARY
09/22/2023 Letter INSPECTION SUMMARY
09/22/2023 Letter INSPECTION SUMMARY
09/27/2023 Letter INSPECTION SUMMARY
11/08/2023 Letter INSPECTION SUMMARY
12/20/2023 Letter INSPECTION SUMMARY
12/20/2023 Letter INSPECTION SUMMARY
02/01/2024 Letter INSPECTION SUMMARY
02/08/2024 Receipt Receipt for transaction: 2024-000722
02/08/2024 Letter INSPECTION SUMMARY
02/08/2024 Letter INSPECTION SUMMARY
02/08/2024 Letter INSPECTION SUMMARY
02/08/2024 Letter INSPECTION SUMMARY
05/21/2024 Letter INSPECTION SUMMARY
05/21/2024 Letter Field Certificate of Occupancy
05/21/2024 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home