Summary
PRRES20213746
Building Permit - Residential
Certificate of Occupancy
BOYER TERRY & KELLE
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED DECK - ENG. FLOOR SYSTEM - OWNER BUILDER close detached building at the same time
07/20/2021
08/11/2021
01/18/2022
10/24/2023
Locations
Contacts
BOYER TERRY & KELLE, Address:725 SW 15TH CIR  
Terry Boyer, Address:725 15TH CIR SW  
kboyer@nuwaycredentials.com  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
CHAIREL ELECTRIC LLC, Address:1657 E SHERIDAN BRIDGE LN  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
Terry and Kelle Boyer, Address:725 SW 15TH CIR, Phone:(816) 716-4204  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $540.00 $540.00 Paid 08/11/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 08/11/2021
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 08/11/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 08/11/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 08/11/2021
9110078-Valuation Fee New Single Family $1,654.57 $1,654.57 Paid 08/11/2021
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 01/17/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 02/16/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 03/19/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 04/18/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 07/17/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 07/17/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 07/17/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 08/09/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 9/13/2021 (10:30) 9/13/2021 09/13/2021
Misc
Corrective Action Required
09/13/2021
INSPECTION DENIED NO EROSION CONTROL PRESENT AT TIME OF INSPECTION PROVIDE EROSION CONTROL AROUND PERIMETER OF LOT, PROTECT CREEK, POND, STREET CLEAN MUD BUILDUP FROM FRONT OF GUTTER BUDDY AT FRONT OF LOT
Erosion Control Inspection Residential Failed 9/13/2021 9/13/2021 09/13/2021
Misc
Corrective Action Required
09/13/2021
INSPECTION DENIED NO EROSION CONTROL PRESENT AT TIME OF INSPECTION 10:57 AM PROVIDE EROSION CONTROL AROUND PERIMETER OF LOT, PROTECT CREEK AND POND CLEAN MUD BUILDUP FROM FRONT OF GUTTER BUDDY AT FRONT OF LOT
Footing Inspection - Residential Failed 9/14/2021 (1:15) 9/14/2021 09/14/2021
Misc
Corrective Action Required
09/13/2021
-add/raise chairs on rebar throughout where rebar doesn't have req clearance to soil -remove soil at jumps where rebar doesn't have req clearance to soil -clean all loose soil/rocks from footing at rear
Footing Inspection - Residential Passed 9/15/2021 (9:15) 9/15/2021 09/15/2021
Misc
Resolved
09/15/2021
Occupancy Inspection - Codes Residential Failed 11/3/2021 11/3/2021 11/03/2021
Miscellaneous Correction
Corrective Action Required
11/03/2021
11-3-21 -HOUSE NOT READY FOR OCCUPANCY- ONLY AT FOUNDATION STAGE -INSPECTION CANCELLED
Underslab Plumbing Inspection - Residential Passed 12/27/2021 12/27/2021 12/27/2021
Erosion Control Inspection Residential Failed 12/27/2021 12/27/2021
Corrective Action Required
12/27/2021
restore silt fence and swadles at front of job site. remove gravel from street.
Underground Electrical Inspection - Residential Passed 7/1/2022 7/1/2022 06/23/2022
Misc
Informational
06/23/2022
Conduit from meter to transformer
All Rough Inspection - Residential Failed 7/11/2022 7/11/2022 07/11/2022
Misc
Corrective Action Required
07/11/2022
Inspection denied erosion control not in compliance -complete all trades before re inspection -upload truss plans and engineered floor joists before reinspection -provide address posted for lot
Erosion Control Inspection Residential Failed 7/11/2022 07/11/2022
Misc
Resolved
07/11/2022
INSPECTION DENIED NO EROSION CONTROL PRESENT AT TIME OF INSPECTION 10:57 AM PROVIDE EROSION CONTROL AROUND PERIMETER OF LOT, PROTECT CREEK AND POND CLEAN MUD BUILDUP FROM FRONT OF GUTTER BUDDY AT FRONT OF LOT
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
07/11/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. maintain erosion control around lot maintain gravel filter clean up street protect storm inlet
Electrical Service Inspection Failed 7/14/2022 7/14/2022 07/14/2022
Misc
Corrective Action Required
07/14/2022
GROUND SERVICE WITH CEE PER CODE
All Rough Inspection - Residential Failed 7/22/2022 7/22/2022 07/22/2022
Misc
Corrective Action Required
07/11/2022
INSPECTION INCOMPLETE AND LIST IS SUBJECT TO CHANGE: -PROVIDE COMPLETE, APPROVED CITY STAMPED PLANS FOR INSPECTION -Provide tension straps at PFH -Provide 5/8” bolt and plate washer at each side of second PFH -Missing 4200 lb concrete embedded strap at second PFH -Tighten anchor bolts -Provide anchor bolts within 12” of plate break -Provide anchor bolt at end of plate-see step down at back garage wall elevator -Provide proper slope at dwv in attic space -Land electrical in attic space -Address (3) nm cables in single penetration at top plates throughout-These cables must be derated per NEC 334.80 and 310.15(B)(3)(a) -Lower Bocca plate at garage wall to protect dwv 2” below top plate -Provide structural strap at both sides of load bearing wall at over bored top plate back garage wall-plate bored greater than 50% -Fireblock top of B vent chase -Midpoint strap all 2” and smaller dwv -Fireblock top and bottom of double walls and fireblock vertical 10’ oc max -Complete gas hook up at fireplace
Electrical Service Inspection Passed 7/27/2022 7/27/2022 07/27/2022
Misc
Resolved
07/27/2022
GROUND SERVICE WITH CEE PER CODE
Erosion Control Inspection Residential Failed 7/29/2022 07/29/2022
Misc
Corrective Action Required
07/29/2022
-Remove porta john from street and place on property
All Rough Inspection - Residential Failed 7/29/2022 7/29/2022 07/29/2022
Misc
Corrective Action Required
07/22/2022
-Provide tension straps at PFH -THESE STRAPS NEED TO CONNECT TO JACK STUDS (SEE DETAIL A ON A.6 -Provide 5/8” bolt and plate washer at each side of second PFH-EADT SIDE OF WEST DOOR -Tighten anchor bolts-NOT COMPLETE-SEE PFH -Provide anchor bolts within 12” of plate break-TIGHTEN NUT IN 2x4 BACK WALL -Address (3) nm cables in single penetration at plates throughout-These cables must be derated per NEC 334.80 and 310.15(B)(3)(a) -SEE UNDER WINDOW IN LIVING ROOM AND KITCHEN NEAR RANGE -Fireblock top of B vent chase-USE APPROVED METHODS -Fireblock top and bottom of double walls and fireblock vertical 10’ oc max-NOT DONE -Complete gas hook up at fireplace-Secure ward flex -Missing truss screw above window in mud room, prep room, throughout sun room, study -Seal top plate penetration at prep -Provide missing fasteners at stud shoes in prep. -Strap exterior top plates lapped less than 24” at dining room -Fireblock dead spaces by fireplace with approved means -Seal through floor penetrations at kitchen -Protect nm for 6” at floor penetration in kitchen island -Add full length Jack stud under beam for porch at exterior corner of wardrobe, master bed, -Lower Bocca plate to protect 2” below plate at master bath all locations -Have engineer address lack of bearing of triple girder truss at fur out wall in master -Have engineer address hole bored in bottom chord of floor truss at stair landing -Provide all missing fasteners in truss hanger at stairs-truss F15 -Strap top plates lapped less than 24” at exterior basement wall north by beam -Sister over notched studs at basement wall north side
All Rough Inspection - Residential Failed 8/3/2022 8/3/2022 08/03/2022
Misc
Corrective Action Required
07/29/2022
-Provide 5/8” bolt and plate washer at each side of second PFH-EADT SIDE OF WEST DOOR -Tighten anchor bolts-NOT COMPLETE-SEE PFH -Fireblock top and bottom of double walls and fireblock vertical 10’ oc max-NOT DONE -Strap exterior top plates lapped less than 24” at dining room south wall -Fireblock dead spaces by fireplace with approved means SEAL GAPS -Add full length Jack stud under beam for porch at exterior corner of wardrobe, master bed, -Lower Bocca plate to protect 2” below plate at master bath all locations
All Rough Inspection - Residential Passed 8/8/2022 8/8/2022 08/08/2022
Misc
Resolved
08/08/2022
Sewer Service Inspection - R Partial 10/19/2022 (1:00) 10/19/2022 10/19/2022
Misc
Informational
10/19/2022
: PARTIAL PASS : - EAST SIDE OF HOUSE TO MAIN IN REAR HAS CLEANOUT ABOUT 90' FROM HOUSE OK COVER MAIN AND TO WYE FOR DETACHED GARAGE RESTROOM -
Sewer Service Inspection - R Passed 10/20/2022 10/20/2022
Misc
Resolved
10/20/2022
: PARTIAL PASS : - EAST SIDE OF HOUSE TO MAIN IN REAR HAS CLEANOUT ABOUT 90' FROM HOUSE OK COVER MAIN AND TO WYE FOR DETACHED GARAGE RESTROOM -
Water Service Inspection - R Passed 10/25/2022 (8:15) 10/25/2022 10/25/2022
Driveway Inspection Passed 12/5/2022 12/5/2022 12/05/2022
Misc
Informational
12/05/2022
On Monday, 12-05-2022. I performed and passed a driveway inspection for placement of concrete.
Gas Service Inspection - Residential Failed 12/8/2022 12/8/2022 12/08/2022
Misc
Corrective Action Required
12/08/2022
-PRESSURE TEST REQUIRED -GAS LINE BOND REQUIRED -GAS LINE NOT ALLOWED TO PENETRATE HVAC AIR RETURN IRC G2415.3
Gas Service Inspection - Residential Passed 12/16/2022 12/16/2022 12/16/2022
Misc
Resolved
12/16/2022
Occupancy Inspection - Codes Residential Failed 1/6/2023 1/6/2023 01/06/2023
Miscellaneous Correction
Resolved
01/06/2023
11-3-21 -HOUSE NOT READY FOR OCCUPANCY- ONLY AT FOUNDATION STAGE -INSPECTION CANCELLED
Misc
Corrective Action Required
01/06/2023
-address pending pier inspection, piers poured without inspection -final grade and sod -check water meter depth and grade at time of final sod and grade -splash blocks and sump pump discharge to extend 36” from foundation -tamper resistant caps at A/c unit -uncover covered manhole -provide guard rail at from stoop where greater than 30” from ground 36” out -garage door to be self closing and latching -outlets in garage to comply with code E3901.9, E3902.2, any non GFCI outlets in unfinished spaces shall be labeled as such and single receptacle. -spark rings at prep kitchen counter top outlets where as required by code -secondary locking device at rear slider -security screws at exterior doors 2per hinge and strike plate -hardware at side dining room door -spark ring at outlet in trim right of fireplace -smoke carbon to be in the immediate vicinity of sleeping rooms -secondary locking device on basement sliders -provide lock out for breaker on all kitchen hardwired appliances -protect engineered floor joists per code section R302.13 of the irc -(2) 1/2” through bolts at each deck post to beam connection rear and side deck -missing nails in joist hangers at deck
Occupancy Inspection - Codes Residential Ready for Temp CO 1/17/2023 1/17/2023 01/17/2023
Misc
Corrective Action Required
01/06/2023
-address pending pier inspection, piers poured without inspection -final grade and sod -check water meter depth and grade at time of final sod and grade meter to be 14”-18” from meter top to well lid -missing nails in joist hangers at deck
Occupancy Inspection - Codes Residential Ready for Temp CO 2/16/2023 02/16/2023
Misc
Corrective Action Required
01/17/2023
-address pending pier inspection, piers poured without inspection -final grade and sod -check water meter depth and grade at time of final sod and grade meter to be 14”-18” from meter top to well lid -missing nails in joist hangers at deck
Occupancy Inspection - Codes Residential Ready for Temp CO 3/16/2023 03/16/2023
Misc
Corrective Action Required
02/16/2023
3/16-TCO approved next 30 days we need to perform a site inspection. -address pending pier inspection, piers poured without inspection -final grade and sod -check water meter depth and grade at time of final sod and grade meter to be 14”-18” from meter top to well lid -missing nails in joist hangers at deck
Occupancy Inspection - Codes Residential Ready for Temp CO 4/18/2023 04/18/2023
Misc
Corrective Action Required
03/16/2023
4/18-TCO approved MUST HAVE SOD INSTALLED 10 FEET FROM HOUSE After sod installation we need to perform a site inspection. 3/16-TCO approved next 30 days we need to perform a site inspection. -address pending pier inspection, piers poured without inspection -final grade and sod -check water meter depth and grade at time of final sod and grade meter to be 14”-18” from meter top to well lid -missing nails in joist hangers at deck
Occupancy Inspection - Codes Residential Failed 5/18/2023 05/18/2023
Misc
Corrective Action Required
04/18/2023
4/18-TCO approved MUST HAVE SOD INSTALLED 10 FEET FROM HOUSE After sod installation we need to perform a site inspection. -final grade and sod
Misc
Corrective Action Required
05/18/2023
-Erosion control failed in back yard
Occupancy Inspection - Codes Residential Ready for Temp CO 8/8/2023 08/08/2023
Misc
Corrective Action Required
05/18/2023
4/18-TCO approved MUST HAVE SOD INSTALLED 10 FEET FROM HOUSE After sod installation we need to perform a site inspection. -final grade and sod -check water meter depth and grade at time of final sod and grade meter to be 14”-18” from meter top to well lid. close shopw permit also
Misc
Corrective Action Required
05/18/2023
-Erosion control failed in back yard
MISC
Corrective Action Required
08/08/2023
TCO extension form granted Alex Fischer 08/08/2023 7:22 AM
Erosion Control Inspection Residential Passed 10/23/2023
Misc
Corrective Action Required
07/29/2022
-Remove porta john from street and place on property
Occupancy Inspection - Codes Residential Failed 9/11/2023 10/24/2023
Misc
Corrective Action Required
08/08/2023
4/18-TCO approved MUST HAVE SOD INSTALLED 10 FEET FROM HOUSE After sod installation we need to perform a site inspection. -final grade and sod -check water meter depth and grade at time of final sod and grade meter to be 14”-18” from meter top to well lid. close shopw permit also
Misc
Corrective Action Required
08/08/2023
-Erosion control failed in back yard
MISC
Corrective Action Required
08/08/2023
TCO extension form granted Alex Fischer 08/08/2023 7:22 AM
Plot Plan Inspection Passed 10/24/2023
Occupancy Inspection - Codes Residential Full C of O 10/24/2023 10/24/2023
Misc
Resolved
10/24/2023
Misc
Resolved
10/24/2023
MISC
Resolved
10/24/2023
Documents & Images
Date Uploaded File Type Document Name
07/22/2021 Application Form APPLICATION
07/22/2021 Permit Codes Residential Plan Review
08/06/2021 Approved Plans APPROVED PLANS
08/06/2021 Approved Plans APPROVED PLOT PLAN
08/06/2021 Permit Codes Residential Plan Review
08/11/2021 Permit DS Building Permit
08/11/2021 Receipt Receipt for transaction:2021-006437
09/13/2021 Letter INSPECTION SUMMARY
09/13/2021 Letter INSPECTION SUMMARY
09/14/2021 Letter INSPECTION SUMMARY
09/15/2021 Letter INSPECTION SUMMARY
11/03/2021 Letter INSPECTION SUMMARY
12/27/2021 Letter INSPECTION SUMMARY
12/27/2021 Letter INSPECTION SUMMARY
06/23/2022 Letter INSPECTION SUMMARY
07/11/2022 Letter INSPECTION SUMMARY
07/11/2022 Letter INSPECTION SUMMARY
07/14/2022 Letter INSPECTION SUMMARY
07/14/2022 Letter INSPECTION SUMMARY
07/20/2022 Approved Plans APPROVED FLOOR JOIST LAYOUT
07/20/2022 Approved Plans APPROVED FLOOR JOIST PACKAGE
07/20/2022 Approved Plans APPROVED TRUSS LAYOUT
07/20/2022 Approved Plans APPROVED TRUSS PACKAGE
07/20/2022 Approved Plans ENG APPROVAL LETTER FOR TRUSSES AND FLOOR JOISTS
07/22/2022 Letter INSPECTION SUMMARY
07/26/2022 072622 SHEET A1_POST INSTALLED HOLD DOWN
07/27/2022 Letter INSPECTION SUMMARY
07/29/2022 Letter INSPECTION SUMMARY
07/29/2022 Letter INSPECTION SUMMARY
08/02/2022 boyer truss repair seal
08/02/2022 080122 boyer roof truss bearing condition letter
08/03/2022 Letter INSPECTION SUMMARY
08/08/2022 Letter INSPECTION SUMMARY
10/19/2022 Letter INSPECTION SUMMARY
10/20/2022 Letter INSPECTION SUMMARY
10/25/2022 Letter INSPECTION SUMMARY
12/05/2022 Letter INSPECTION SUMMARY
12/08/2022 Letter INSPECTION SUMMARY
12/16/2022 Letter INSPECTION SUMMARY
01/06/2023 Letter INSPECTION SUMMARY
01/10/2023 pier picture
01/17/2023 Certificate/License Codes Temporary Certificate of Occupancy
01/17/2023 Receipt Receipt for transaction:2023-000297
02/16/2023 TCOExtension Request Form
02/16/2023 Certificate/License Codes Temporary Certificate of Occupancy
02/16/2023 Receipt Receipt for transaction:2023-000906
03/16/2023 TCOExtension Request Form
03/19/2023 Certificate/License Codes Temporary Certificate of Occupancy
03/19/2023 Receipt Receipt for transaction:2023-001525
03/25/2023 Boyer plot plan for grass
03/27/2023 Email Response plan for grass
03/27/2023 Boyer plot plan CMR
03/27/2023 Boyer plot plan for grass
04/10/2023 Boyer plot plan updated
04/18/2023 Certificate/License Codes Temporary Certificate of Occupancy
04/18/2023 Receipt Receipt for transaction:2023-002202
05/11/2023 TCOExtension Request Form0 (1)
05/18/2023 Letter INSPECTION SUMMARY
07/17/2023 Certificate/License Codes Temporary Certificate of Occupancy
07/17/2023 Certificate/License Codes Temporary Certificate of Occupancy
07/17/2023 Certificate/License Codes Temporary Certificate of Occupancy
07/17/2023 Receipt Receipt for transaction: 2023-005509
08/07/2023 LS - TCO Extension Request Form0 (1)
08/09/2023 Certificate/License Codes Temporary Certificate of Occupancy
08/09/2023 Receipt Receipt for transaction:2023-006164
08/29/2023 LS - TCO Extension Request Form0 (1)
09/11/2023 LS - TCO Extension Request Form0 (1)
10/24/2023 Letter INSPECTION SUMMARY
10/24/2023 Letter INSPECTION SUMMARY
10/24/2023 Letter INSPECTION SUMMARY
10/24/2023 Letter INSPECTION SUMMARY
10/24/2023 Letter Field Certificate of Occupancy
10/24/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home