Permit Application Status

PRRES20211291


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20211291
Building Permit - Residential
Certificate of Occupancy
SUMMIT VIEW FARMS DEVELOPMENT GROUP LLC
NEW SINGLE FAMILY
NEW HOUSE - ENG FLOOR SYSTEM ( DEFERRED ) - UNFINISHED BASEMENT -
03/23/2021
04/06/2021
08/05/2022
Locations
Contacts
SUMMIT VIEW FARMS DEVELOPMENT GROUP LLC, Address:13450 E STATE ROUTE 150  
STEWART BUILDERS LLC, Address:12 SEQUOYAH PT, Phone:(816) 510-7850  
RANDY@STEWARTBUILDERSKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
TRI-COUNTY PLUMBING LLC, Address:PO BOX 234, Phone:(816) 720-3222  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 03/25/2021 03/23/2021
Brandon Kalwei
Residential Plan Review Approved 03/25/2021 03/23/2021
Brandon Kalwei
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,472.01 $1,472.01 Paid 04/06/2021
8331507-Sewer Connection Fee $540.00 $540.00 Paid 04/06/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 04/06/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 04/06/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 04/06/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 04/06/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 03/01/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 08/02/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 5/5/2021 05/05/2021
Underslab Plumbing Inspection - Residential Failed 6/4/2021 6/4/2021 06/04/2021
Misc
Corrective Action Required
06/04/2021
INSPECTION DENIED -MAINTAIN EROSION CONTROL AT FRONT OF LOT -CLEAN ALL MUD AND GRAVEL FROM STREET AND STORM INLET
Erosion Control Inspection Residential Failed 6/4/2021 6/4/2021 06/04/2021
Misc
Corrective Action Required
06/04/2021
INSPECTION DENIED -MAINTAIN EROSION CONTROL AT FRONT OF LOT -CLEAN ALL MUD AND GRAVEL FROM STREET AND STORM INLET
Sewer Service Inspection - R Passed 6/7/2021 (1:00) 6/7/2021 06/07/2021
Water Service Inspection - R Partial 6/7/2021 6/7/2021 06/07/2021
Misc
Informational
06/07/2021
-PARTIAL ON PEX TO MID POINT FRONT YARD
Water Service Inspection - R Passed 6/8/2021 (11:00) 6/8/2021 06/08/2021
Misc
Resolved
06/08/2021
Underslab Plumbing Inspection - Residential Passed 6/9/2021 6/9/2021 06/09/2021
Misc
Resolved
06/09/2021
Piers/Caissons Inspection - Residential Passed 11/18/2021 (8:45) 11/18/2021 11/18/2021
All Rough Inspection - Residential Not Ready 2/8/2022 02/08/2022
Misc
Corrective Action Required
02/08/2022
This house is not ready for all rough inspection. Items listed are only in the garage and list will change. Complete all items before further inspection -Maintain gravel filter, clean silt from street and storm inlet -Install PFH per detail at garage-nailing pattern, hold down straps, tension straps, anchor bolts etc. -Address holes drilled through LVL header at garage -Install anchor bolts within 12” of plate breaks and within 4” of end of plate in garage -Strap top plate lapped less than 24” at East garage -Address exterior walls not connected at top plates at garage/ entry -Seal top and bottom plate penetrations in garage East wall and by entry -Attic access requires min 30” vertical clearance -Fur down and fireblock at hvac for Insulation in garage -Fur out at dryer box for insulation -Fireblock soffit line at fur down -Missing roof boots at radon and vent to roof -Support hip truss above single car bay-both locations -Address braced walls not nailed to top plates throughout -Nail exterior sheathing braced walls per plan throughout -Ceiling joists at garage tapered greater than 1/4 of depth of joist -Fireblock top of hvac chase -Nail ledger board for rafters to 2nd floor wall framing above garage and bath west side
Electrical Service Inspection Failed 2/8/2022 02/08/2022
Gas Service Inspection - Residential Failed 2/8/2022 02/08/2022
All Rough Inspection - Residential Failed 2/14/2022 2/14/2022 02/14/2022
Misc
Corrective Action Required
02/08/2022
This house is not ready for all rough inspection. Items listed are only in the garage and list will change. Complete all items before further inspection -Install PFH per detail at garage-hold down straps, anchor bolts TIGHT -Install anchor bolts within 12” of plate breaks and within 4” of end of plate in garage -Address exterior walls not connected at top plates at garage/ entry -Fur down and fireblock at hvac for Insulation in garage -Fur out at dryer box for insulation -Fireblock soffit line at fur down when using Unfaced insulation for fire blocking it must be packed tight -Support hip truss above single car bay-both locations -Address braced walls not nailed to top plates throughout
Electrical Service Inspection Passed 2/15/2022 02/15/2022
Gas Service Inspection - Residential Passed 2/15/2022 02/15/2022
All Rough Inspection - Residential Partial 3/1/2022 3/1/2022 03/02/2022
Misc
Corrective Action Required
02/15/2022
-Provide blocking between joists above beam and bearing partitions for lateral restraint per R502.7 -Complete plumbing and seal floor penetration at master -Address sheet rock used as top plate at great room/master wall by fireplace -Nail all corner studs and intersecting wall studs per code-12” oc -Address roof load and joists bearing on non load bearing wall upstairs bath- hanger at tail joist bath -Fire place flue clearance at roof -Provide engineer report or 75% bearing at all roof members on bearing walls-upstairs bedrooms hips -Address notched valley rafter and bearing -Provide solid blocking at fireblocking second floor flue chase to attic-Seal penetration -Seal top plate penetration at Top plate 3/4 bath -Complete plumbing in basement -Secure water line -Address cut top plates at LVL bearing above basement stairs -strap both sides -Nail all exterior sheathing per code All I joists must be protected on final
All Rough Inspection - Residential Failed 3/3/2022 03/03/2022
Misc
Corrective Action Required
03/02/2022
**OK TO INSULATE AND ROCK- RESHCEDULE WHEN MASTER SHOWER IS COMPLETE BEFORE INSULATING BASEMENT I JOISTS AND BEFORE OCCUPANCY INSPECTION -Complete plumbing and seal floor penetration at master -Complete plumbing in basement -Secure water line
Driveway Inspection Partial 4/26/2022 04/26/2022
Misc
Informational
04/26/2022
On 4.26.2022 I performed a driveway inspection and pass the subgrade to pour concrete
Sidewalk Inspection Partial 5/3/2022 5/3/2022 05/03/2022
Misc
Informational
05/03/2022
On 5.3.2022 I performed a sidewalk inspection and pass the subgrade to pour concrete.
Plot Plan Inspection Passed 7/8/2022 07/08/2022
All Rough Inspection - Residential Passed 7/20/2022 07/20/2022
Misc
Resolved
07/20/2022
Plot Plan Inspection Passed 7/27/2022 07/27/2022
Erosion Control Inspection Residential Failed 7/27/2022 07/27/2022
Misc
Resolved
07/27/2022
INSPECTION DENIED -MAINTAIN EROSION CONTROL AT FRONT OF LOT -CLEAN ALL MUD AND GRAVEL FROM STREET AND STORM INLET
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
07/27/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. erosion control must be in place until time of sod
Occupancy Inspection - Codes Residential Failed 7/27/2022 7/27/2022 07/27/2022
Misc
Corrective Action Required
07/27/2022
-erosion control to be maintained until sod in in place -obtain lawn irrigation permit -sod -check water meter at time of sod -splash blocks and sump pump discharge to extend 36” from foundation -address pending driveway and sidewalk inspections -label all non GFCI outlets in unfinished spaces -hot neutral reverse in master bath outlet -spark ring required above fireplace -steps to back patio to be to code step greater than 7 3/4” , rises greater than 3/8” difference -identify sewer tracer wire
Driveway Inspection Passed 7/27/2022 7/27/2022 07/28/2022
Misc
Informational
04/26/2022
On 4.26.2022 I performed a driveway inspection and pass the subgrade to pour concrete. 7.27.2022 Driveway appears to be in compliance
Sidewalk Inspection Passed 7/27/2022 7/27/2022 07/28/2022
Misc
Informational
05/03/2022
On 5.3.2022 I performed a sidewalk inspection and pass the subgrade to pour concrete. 7.27.2022 Sidewalk appears to be in compliance.
Occupancy Inspection - Codes Residential Failed 7/29/2022 7/29/2022 07/29/2022
Misc
Corrective Action Required
07/27/2022
-sod -check water meter at time of sod -splash blocks and sump pump discharge to extend 36” from foundation
Occupancy Inspection - Codes Residential Ready for Temp CO 8/2/2022 08/02/2022
Misc
Corrective Action Required
07/29/2022
-sod -check water meter at time of sod -splash blocks and sump pump discharge to extend 36” from foundation
Occupancy Inspection - Codes Residential Temporary C of O 8/3/2022 8/3/2022 08/02/2022
Misc
Corrective Action Required
08/02/2022
-sod -check water meter at time of sod -splash blocks and sump pump discharge to extend 36” from foundation
Erosion Control Inspection Residential Passed 8/5/2022 08/05/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
08/05/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. erosion control must be in place until time of sod
Occupancy Inspection - Codes Residential Full C of O 8/5/2022 8/5/2022 08/05/2022
Misc
Resolved
08/05/2022
-sod -check water meter at time of sod -splash blocks and sump pump discharge to extend 36” from foundation
Documents & Images
Date Uploaded File Type Document Name
03/23/2021 Application Form APPLICATION
03/23/2021 Application Form excise tax
03/23/2021 DW Permit Plan Harrison II Lot 66 SVF 2316 SW Chase Cir
03/23/2021 Lot 66 SVF Plot Plan
03/23/2021 Approved Plans APPROVED PLANS
03/23/2021 Plot Plan APPROVED PLOT PLAN
04/06/2021 Receipt Receipt for transaction:2021-001768
04/06/2021 Letter DS Building Permit
05/04/2021 M L Crose 2316 SW Chase Cir LSMO SVF Lot 66 Steward Bldrs P 2021-1291 3rd Party Footing Inspection Report 5-4-21
05/05/2021 Letter INSPECTION SUMMARY
06/04/2021 Letter INSPECTION SUMMARY
06/04/2021 Letter INSPECTION SUMMARY
06/07/2021 Letter INSPECTION SUMMARY
06/07/2021 Letter INSPECTION SUMMARY
06/08/2021 Letter INSPECTION SUMMARY
06/09/2021 Letter INSPECTION SUMMARY
11/18/2021 Letter INSPECTION SUMMARY
01/25/2022 Approved Plans APPROVED PLANS
02/07/2022 Approved Plans APPROVED I JOIST PLAN
02/08/2022 Letter INSPECTION SUMMARY
02/08/2022 Letter INSPECTION SUMMARY
02/08/2022 Letter INSPECTION SUMMARY
02/11/2022 DW FRAMING REPORT Harrison II Lot 66 SVF 2316 SW Chase Cir
02/14/2022 Letter INSPECTION SUMMARY
02/14/2022 Letter INSPECTION SUMMARY
02/15/2022 Letter INSPECTION SUMMARY
02/15/2022 Letter INSPECTION SUMMARY
02/15/2022 Letter INSPECTION SUMMARY
02/23/2022 Letter INSPECTION SUMMARY
02/23/2022 Letter INSPECTION SUMMARY
02/28/2022 DW FRAMING REPORT Harrison II Lot 66 SVF 2316 SW Chase Cir
03/01/2022 Letter INSPECTION SUMMARY
03/01/2022 DW ROUGH FRAMING REPORT Harrison II Lot 66 SVF 2316 SW Chase Cir
03/01/2022 Receipt Receipt for transaction:2022-001087
03/03/2022 Letter INSPECTION SUMMARY
03/22/2022 Letter INSPECTION SUMMARY
03/22/2022 Letter INSPECTION SUMMARY
03/22/2022 Letter INSPECTION SUMMARY
04/26/2022 Letter INSPECTION SUMMARY
05/10/2022 Letter INSPECTION SUMMARY
07/05/2022 Plot Plan APPROVED AS GRADED PLOT PLAN
07/08/2022 Letter INSPECTION SUMMARY
07/20/2022 Letter INSPECTION SUMMARY
07/27/2022 Letter INSPECTION SUMMARY
07/27/2022 Letter INSPECTION SUMMARY
07/27/2022 Letter INSPECTION SUMMARY
07/29/2022 Letter INSPECTION SUMMARY
08/02/2022 Receipt Receipt for transaction:2022-006296
08/02/2022 Letter Codes Temporary Certificate of Occupancy
08/02/2022 Letter INSPECTION SUMMARY
08/02/2022 Letter INSPECTION SUMMARY
08/05/2022 Letter Codes Final Certificate of Occupancy
08/05/2022 Letter Field Certificate of Occupancy
08/05/2022 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home