Summary
PRRES20202309
Building Permit - Residential
Certificate of Occupancy
D AND D BUILDING INC
NEW SINGLE FAMILY
NEW HOUSE - FININSHED BASEMENT - COVERED DECK SUSPENDED SLAB STOP WORK ORDER generated on 01/27/2021 12:00 AM by username 'John Morris'. STOP WORK ORDER removed on 03/15/2021 12:00 AM by username 'John Morris'.
08/14/2020
08/27/2020
04/27/2022
Locations
Contacts
D AND D BUILDING INC, Address:PO BOX 7014, Phone:(816) 491-2125  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
TEAGUE ELECTRIC CONSTRUCTION INC, Address:12425 W 92ND ST, Phone:(913) 529-4600  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
DANDDBUILDINGCO@GMAIL.COM  
D AND D BUILDING INC, Address:PO BOX 7014, Phone:(816) 491-2125  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 08/18/2020 08/25/2020
Kim Brennan
Misc
Corrective Action Required
08/14/2020

Drawings must be signed and sealed by a licensed professional from the State of Missouri.
11 Designate R-value(s) for floors, walls, ceilings, roof/ceilings.
Corrective Action Required
08/14/2020

Designate R-value(s) for floors, walls, ceilings, roof/ceilings. (LSCO 7-802) This table references the 2012 code book and it should reference the 2018 code book.
37 Provide details for any walls over 10 feet in height.
Corrective Action Required
08/14/2020

Provide details for any walls over 10 feet in height. Include stud grade, size, spacing and actual, uninterrupted height. (IRC Section 602.3.1 and Table 602.3(5) & 602.3.1) Does not specify uninterrupted in height
Plot Plan Review Approved 08/18/2020 08/20/2020
Kim Brennan
Deck location
Corrective Action Required
08/14/2020

Deck location, with dimensions to property lines must be provided on the plot plan. Please show that this is a covered deck as well
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $990.03 $990.03 Paid 08/27/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 08/27/2020
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 08/27/2020
8331507-Sewer Connection Fee $480.00 $480.00 Paid 08/27/2020
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 08/27/2020
8350015-Water Meter Fee $455.54 $455.54 Paid 08/27/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Partial 10/6/2020 (11:00) 10/6/2020 10/06/2020
Misc
Corrective Action Required
10/06/2020
POUR AT OWN RISK -Provide updated drawings & engineer report to reflect field changes and additions of footings & foundation wall
Footing Inspection - Residential Failed 11/23/2020 11/23/2020
Misc
Corrective Action Required
10/06/2020
-Provide updated drawings & engineer report to reflect field changes and additions of footings & foundation wall. Update- Revised plans have not been submitted as of 11/23 for the rear walkout retaining wall for the rear garage entry. Please submit the plot plan showing retaining wall and elevation changes. MARK HARDING 11/23/2020 9:36 AM
Footing Inspection - Residential Failed - Stop Work 1/27/2021 01/27/2021
Misc
Corrective Action Required
11/23/2020
-Provide updated drawings & engineer report to reflect field changes and additions of footings & foundation wall. Update- Revised plans have not been submitted as of 11/23 for the rear walkout retaining wall for the rear garage entry. Please submit the plot plan showing retaining wall and elevation changes. MARK HARDING 11/23/2020 9:36 AM Stop work order issued John Morris 1/27/2021
Underslab Plumbing Inspection - Residential Failed 3/2/2021 03/02/2021
Misc
Corrective Action Required
03/02/2021
Provide positive or neutral slope of interior underslab drain tile throughout
Erosion Control Inspection Residential Failed 3/2/2021 03/02/2021
Misc
Corrective Action Required
03/02/2021
-Erosion control requires continuous maintenance. Repair damaged sections within 48 hours -immediate street cleanup required -no further inspections until issues are resolved
Miscellaneous Inspection Failed 3/2/2021 03/02/2021
Misc
Corrective Action Required
03/02/2021
Post site address
Footing Inspection - Residential Passed 3/15/2021 03/15/2021
Misc
Resolved
03/15/2021
-Provide updated drawings & engineer report to reflect field changes and additions of footings & foundation wall. Update- Revised plans have not been submitted as of 11/23 for the rear walkout retaining wall for the rear garage entry. Please submit the plot plan showing retaining wall and elevation changes. MARK HARDING 11/23/2020 9:36 AM Stop work order issued John Morris 1/27/2021
Suspended Slab Inspection Failed 3/15/2021 (1:45) 3/15/2021 03/15/2021
Misc
Corrective Action Required
03/15/2021
unable to verify header detail 5/S2.0 at 6' foundation opening rear of structure due to foundation walls being poured prior to inspection of this detail
Erosion Control Inspection Residential Failed 3/15/2021 03/15/2021
Misc
Corrective Action Required
03/02/2021
-Erosion control requires continuous maintenance. Repair damaged sections within 48 hours -immediate street cleanup required -no further inspections until issues are resolved
Misc
Corrective Action Required
03/15/2021
First notice dated 03/02/2021 Second and final notice 03/15/2021 Stop work order will be issued in 48 hours if issues are not resolved
Erosion Control Inspection Residential Failed 3/17/2021 3/17/2021 03/17/2021
Misc
Partial Correction
03/17/2021
-immediate street cleanup required -no further inspections until issues are resolved
Misc
Corrective Action Required
03/15/2021
First notice dated 03/02/2021 Second notice 03/15/2021 Third notice 03/17/2021 - partial corrections made, immediate street cleanup still required Stop work order will be issued in 24 hours if issues are not resolved
Miscellaneous Inspection Passed 3/17/2021 03/17/2021
Misc
Resolved
03/17/2021
Post site address
Erosion Control Inspection Residential Failed 5/12/2021 05/12/2021
Misc
Corrective Action Required
05/12/2021
-Erosion control requires continuous maintenance. Repair damaged sections within 48 hours -immediate street cleanup required -no further inspections until issues are resolved
Misc
Resolved
05/12/2021
First notice dated 03/02/2021 Second notice 03/15/2021 Third notice 03/17/2021 - partial corrections made, immediate street cleanup still required Stop work order will be issued in 24 hours if issues are not resolved
Suspended Slab Inspection Passed 5/18/2021 05/18/2021
Misc
Resolved
05/18/2021
unable to verify header detail 5/S2.0 at 6' foundation opening rear of structure due to foundation walls being poured prior to inspection of this detail
Erosion Control Inspection Residential Failed 5/12/2021 05/18/2021
Misc
Corrective Action Required
05/12/2021
-Erosion control requires continuous maintenance. Repair damaged sections within 48 hours -no further inspections until issues are resolved FINAL NOTICE, STOP WORK ORDER WILL BE ISSUED IN 48 HOURS
Sewer Service Inspection - R Passed 6/7/2021 (1:00) 6/7/2021 06/07/2021
Water Service Inspection - R Passed 6/8/2021 (9:45) 6/8/2021 06/08/2021
Gas Service Inspection - Residential Failed 7/22/2021 7/22/2021 07/22/2021
Misc
Corrective Action Required
07/22/2021
-No pressure
Electrical Service Inspection Passed 7/22/2021 6/22/2021 07/22/2021
All Rough Inspection - Residential Failed 7/22/2021 07/22/2021
Misc
Corrective Action Required
07/22/2021
-Strap header and nail sheathing of garage PFH wall per plan -Garage ceiling joist notched more than 25% -Fb double stud wall near refrigerator -Expose deck roof ridge support framing -Secure CSST gas line every 32” inside fireplace space -Complete fireplace flue through roof; complete framing and secure fireplace to framing -Provide roof purlin above master area -Move master closet roof support to bearing wall -Studs not continuous full height at front bedroom gable wall -Provide a floor receptacle at foyer guardrail for foyer larger than 60 sq ft -Fb all basement wall space from fur down ceiling space and joist space; fb wall vertically at max ten ft interval, including space above windows -Complete basement bedroom closet ceiling framing and fire block as required -Have engineer address over-notched joist above front basement bedroom -Security blocking for basement walkout door -Tighten all anchor nuts -Install a wall receptacle at wall space near wet bar countertop -Provide brace walls per A/4 detail -Brace interior walls per plan **OK TO INSULATE
All Rough Inspection - Residential Failed 8/6/2021 08/06/2021
Misc
Corrective Action Required
07/22/2021
-PROVIDE CITY APPROVED, STAMPED PLANS FOR INSPECTION -Fb double stud wall near refrigerator-SEAL GAPS AT LAUNDRY SIDE -Expose deck roof ridge support framing -Move master closet roof support to bearing wall -Studs not continuous full height at front bedroom gable wall-HAVE ENGINEER APPROVE CORRECTION -Fb all basement wall vertically at max ten ft interval, including space above windows -Complete basement bedroom closet ceiling framing and fire block as required-SEAL GAPS -Have engineer address over-notched joist above front basement bedroom -Provide brace walls per A/4 detail -Brace interior walls per plan **OK TO INSULATE
All Rough Inspection - Residential Failed 8/24/2021 08/24/2021
Misc
Corrective Action Required
08/06/2021
-Fireblock double stud wall near refrigerator-SEAL GAPS AT LAUNDRY SIDE -Studs not continuous full height at front bedroom gable wall-HAVE ENGINEER APPROVE CORRECTION -Have engineer address over-notched joist above front basement bedroom -Provide brace walls per A/4 detail, nail off all metal straps, nailing of exterior sheathing per CS-PF design, see detail page 5 of plans **OK TO INSULATE
Gas Service Inspection - Residential Passed 10/8/2021 10/8/2021 10/08/2021
Misc
Resolved
10/08/2021
-No pressure
All Rough Inspection - Residential Passed 10/8/2021 10/8/2021 10/08/2021
Misc
Resolved
10/08/2021
-Fireblock double stud wall near refrigerator-SEAL GAPS AT LAUNDRY SIDE -Provide brace walls per A/4 detail, nail off all metal straps, nailing of exterior sheathing per CS-PF design, see detail page 5 of plans **OK TO INSULATE
Driveway Inspection Partial 12/27/2021 12/27/2021
Misc
Informational
12/27/2021
Driveway was framed up with aggregate in and compacted. 12/27/21 ES
Sidewalk Inspection Partial 12/27/2021 12/27/2021
Misc
Informational
12/27/2021
Sidewalk was framed up with aggregate in and compacted. 12/27/21 ES
Underslab Plumbing Inspection - Residential Passed 1/28/2022 01/28/2022
Misc
Resolved
01/28/2022
Provide positive or neutral slope of interior underslab drain tile throughout
Occupancy Inspection - Codes Residential Failed 1/28/2022 1/28/2022 01/28/2022
Misc
Corrective Action Required
01/28/2022
MAINTAIN EROSION CONTROL NO FURTHER INSPECTIONS UNTIL EROSION CONTROL IS IN COMPLIANCE -complete final grade and sod -splash blocks and sump pump discharge to extend 36” from foundation -sidewalk and driveway need be completed and inspected -check water meter at time of final grade and sod -outlet required at left and right of fireplace -Electrical outlet in dining room not complete -lock out on how water heater breaker & finish installing -master bathroom fan not working -label all non GFCI outlets in unfinished spaces. (See downstairs garage)—complete electrical at downstairs kitchen area -outlet within 6’ of sink need GFCI protection (see right of basement kitchen sink) -security screws at basement back patio door -back patio light to be of the sealed type -(2) 1/2” through bolts at deck post to beam connections -piers poured without inspection -address plans call for 3 piers (only 2 poured) -seal top of meter can, Ac disconnect and all other exterior penetrations
Plot Plan Inspection Passed 3/24/2022 03/24/2022
Erosion Control Inspection Residential Partial 3/24/2022 03/24/2022
Misc
Resolved
03/24/2022
-Erosion control requires continuous maintenance. Repair damaged sections within 48 hours -no further inspections until issues are resolved FINAL NOTICE, STOP WORK ORDER WILL BE ISSUED IN 48 HOURS
Misc
Informational
03/24/2022
Erosion control in compliance at time of inspection
Occupancy Inspection - Codes Residential Failed 3/24/2022 3/24/2022 03/24/2022
Misc
Corrective Action Required
01/28/2022
HOME SHALL NOT BE STAGED/OCCUPIED UNTIL A CERTIFICATE OF OCCUPANCY IS GRANTED -complete sod -splash blocks and sump pump discharge to extend 36” from foundation -check water meter at time of final grade and sod —complete electrical at downstairs kitchen area -(2) 1/2” through bolts at deck post to beam connections -address piers poured without inspection -address plans call for 3 piers (only 2 poured) -seal top of meter can, Ac disconnect and all other exterior penetrations (will check at sod)
Occupancy Inspection - Codes Residential Failed 4/15/2022 4/15/2022 04/15/2022
Misc
Corrective Action Required
03/24/2022
-water meter to be 14-18” from meter lid to well lid, meter must maintain clearance underneath to remain serviceable -address piers poured without inspection
Occupancy Inspection - Codes Residential Failed 4/25/2022 4/25/2022 04/25/2022
Misc
Corrective Action Required
04/15/2022
-address piers poured without inspection
Piers/Caissons Inspection - Residential Passed 4/27/2022 04/27/2022
Erosion Control Inspection Residential Passed 4/27/2022 04/27/2022
Misc
Informational
03/24/2022
Erosion control in compliance at time of inspection
Occupancy Inspection - Codes Residential Full C of O 4/27/2022 4/27/2022 04/27/2022
Misc
Resolved
04/27/2022
-address piers poured without inspection
Documents & Images
Date Uploaded File Type Document Name
08/14/2020 Letter Permit Application
08/14/2020 Drawing 2020.08.13_Lot 31 Whispering Woods_Suspended Slab Design_Sealed
08/14/2020 Letter Codes Residential Plan Review
08/20/2020 Plot Plan Approved Plot Plan
08/25/2020 Drawing Approved Drawings
08/27/2020 Receipt Receipt for transaction:2020-005753
08/27/2020 Letter DS Building Permit
11/23/2020 Letter INSPECTION SUMMARY
11/23/2020 Letter INSPECTION SUMMARY
01/27/2021 Letter Stop Work Order
01/28/2021 31 WHISPERING WOOD 10-02-2020 -BUILD PLAN (REVISED)
01/28/2021 WW31FINAL rev 3
01/28/2021 Plot Plan APPROVED REVISED PLOT PLAN
01/28/2021 Plans APPROVED REVISED HOUSE PLAN
03/02/2021 Letter INSPECTION SUMMARY
03/02/2021 Letter INSPECTION SUMMARY
03/02/2021 Letter INSPECTION SUMMARY
03/15/2021 Letter INSPECTION SUMMARY
03/15/2021 Letter INSPECTION SUMMARY
03/15/2021 Letter INSPECTION SUMMARY
03/17/2021 Letter INSPECTION SUMMARY
03/17/2021 Letter INSPECTION SUMMARY
04/07/2021 Final_2021_03_31_SusGSlab_Lees Summit_D&D
05/12/2021 Letter INSPECTION SUMMARY
05/18/2021 Letter INSPECTION SUMMARY
05/18/2021 Letter INSPECTION SUMMARY
06/07/2021 Letter INSPECTION SUMMARY
06/08/2021 Letter INSPECTION SUMMARY
07/22/2021 Letter INSPECTION SUMMARY
07/22/2021 Letter INSPECTION SUMMARY
07/22/2021 Letter INSPECTION SUMMARY
08/06/2021 Letter INSPECTION SUMMARY
08/24/2021 Letter INSPECTION SUMMARY
10/07/2021 DD-7167 Lot 31 Whispering Woods Inspection Items
10/08/2021 Letter INSPECTION SUMMARY
10/08/2021 Letter INSPECTION SUMMARY
12/27/2021 Letter INSPECTION SUMMARY
12/27/2021 Letter INSPECTION SUMMARY
01/28/2022 Letter INSPECTION SUMMARY
01/28/2022 Letter INSPECTION SUMMARY
03/24/2022 Letter INSPECTION SUMMARY
03/24/2022 Letter INSPECTION SUMMARY
03/24/2022 Letter INSPECTION SUMMARY
03/24/2022 20210329_092933_1
03/24/2022 20210329_092936_1
03/24/2022 imagejpeg_0
04/14/2022 21-002-55 Deck Beam Letter - Permit Number Rev
04/15/2022 Letter INSPECTION SUMMARY
04/25/2022 Letter INSPECTION SUMMARY
04/27/2022 Letter Codes Final Certificate of Occupancy
04/27/2022 Letter Field Certificate of Occupancy
04/27/2022 Letter INSPECTION SUMMARY
04/27/2022 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home