Summary
PRRES20200275
Building Permit - Residential
Certificate of Occupancy
CLAYTON PROPERTIES GROUP INC
NEW SINGLE FAMILY
NEW HOUSE - PARTIAL FINISHED BASEMENT - COVERED PATIO - ROOF TRUSS
02/06/2020
02/11/2020
03/22/2021
Locations
Contacts
CLAYTON PROPERTIES GROUP INC, Address:120 SE 30TH ST  
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 02/10/2020 02/10/2020
Dylan Eppert
Miscellaneous Correction
Corrective Action Required
02/10/2020

COVERED PATIO WILL NEED TO BE ALTERED SINCE THE PLACEMENT ON THE PLOT PLAN WILL NOT ALLOW WHAT YOU ARE PURPOSING. COVERED PATIO HAS TO BE 30 FEET BACK FROM THE REAR PROPERTY LINE. wE DO ALLOW A 5 FOOT VARIANCE BUT THE PATIO EXCEEDS EVEN THE VARIANCE. pLEASE REVISE COVERED PATIO AND RESUBMIT.
Plot Plan Review Approved 02/10/2020 02/10/2020
Dylan Eppert
Deck location
Corrective Action Required
02/10/2020

Deck location, with dimensions to property lines must be provided on the plot plan. COVERED PATIO CANNOT BE IN THAT LOCATION AS IT EXCEEDS PAST THE 30 FOOT SET BACK THAT MUST BE MET PER OUR UDO. WE DO ALLOW FIVE FEET OF A VARIANCE IN A SITUATION LIKE THIS BUT YOU ENCROACH 8 FEET PLEASE CLARIFY AND UPDATE PLOT PLAN TO SHOW COVERED DECK.
As-graded plot plan
Corrective Action Required
02/10/2020

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $982.09 $982.09 Paid 02/11/2020
8331507-Sewer Connection Fee $390.00 $390.00 Paid 02/11/2020
8331401-Water Tap Fee $3,477.00 $3,477.00 Paid 02/11/2020
8350015-Water Meter Fee $425.02 $425.02 Paid 02/11/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 02/11/2020
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 02/11/2020
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 10/21/2020
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 10/21/2020
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 10/21/2020
9110080-3rd and Subsequent Inspection Fee (Per Hour) $300.00 $300.00 Paid 03/22/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 3/3/2020 3/3/2020 03/03/2020
Sewer Service Inspection - R Passed 4/1/2020 4/1/2020 04/01/2020
Water Service Inspection - R Partial 4/7/2020 04/07/2020
Water Service Inspection - R Passed 4/8/2020 4/8/2020 04/08/2020
Underslab Plumbing Inspection - Residential Failed 4/9/2020 4/9/2020 04/09/2020
Misc
Corrective Action Required
04/09/2020
- diagonal drain tile shall be from sump to farthest corner at inspection or around perimeter -
Underslab Plumbing Inspection - Residential Passed 4/14/2020 04/14/2020
Misc
Resolved
04/14/2020
Erosion Control Inspection Residential Failed 5/13/2020 05/13/2020
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
05/13/2020
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. CLEAN MUD AND GRAVEL IN STREET
All Rough Inspection - Residential Not Ready 6/15/2020 6/15/2020 06/15/2020
Misc
Corrective Action Required
06/15/2020
NO INSPECTION PERFORMED - NO CITY APPROVED PLANS OR APPROVED TRUSS PLANS ON SITE -
All Rough Inspection - Residential Not Ready 6/18/2020 6/18/2020 06/18/2020
Misc
Corrective Action Required
06/15/2020
- NO CITY APPROVED PLANS ON SITE, PLANS ON SITE ARE NOTED AS BEING REVISED AND ARE NOT STAMPED AND APPROVED BY CITY -
All Rough Inspection - Residential Not Ready 6/24/2020 6/24/2020 06/24/2020
Misc
Corrective Action Required
06/18/2020
- NO CITY APPROVED PLANS ON SITE, PLANS ON SITE ARE NOTED AS BEING REVISED AND ARE NOT STAMPED AND APPROVED BY CITY - 6/24 - PLANS ON SITE ARE NOT CITY STAMPED APPROVED PLANS, NO INSPECTION PERFORMED
Electrical Service Inspection Passed 6/26/2020 6/26/2020 06/26/2020
Gas Piping Inspection - Residential Passed 6/26/2020 6/26/2020 06/26/2020
Gas Service Inspection - Residential Failed 6/26/2020 6/26/2020 06/26/2020
Misc
Corrective Action Required
06/26/2020
- Gas pressure at 0 psi - - Gas pressure must hold at 10 psi for 15 minutes minimum
All Rough Inspection - Residential Failed 6/26/2020 6/26/2020 06/26/2020
Misc
Corrective Action Required
06/24/2020
- Provide 1” clearance B vent at garage top plate - Fireblock radon line top plate at garage - Pan off Fireblock top of fireplace - Secure elect box jacuzzi tub - Secure bath exhaust with metallic tape - Seal all penetrations in top plate - mater closet and water closet, basement - Provide TJC37 single car garage per truss hanger schedule - Provide PFH portal framing per plans - Support and protect pex at showers - Fireblock all tub traps - Security blocking at back door - EC#2 800 lb hold downs per plans - Fireblock vertical between stud and foundation wall in basement ever 10’ per code and seal all gaps where foam has fallen - Address cut floor joist for DWV basement above egress window - City approved plans show fireplace on cantilever in living room with doubled floor joists above rec room
All Rough Inspection - Residential Failed 7/2/2020 7/2/2020 07/02/2020
Misc
Corrective Action Required
06/26/2020
- Provide PFH portal framing per plans - EC#2 800 lb hold downs per plans - missing nut on hold down - Address cut floor joist for DWV basement above egress window - engineer report needed, header for floor joist bearing on interior framing - City approved plans show fireplace on cantilever in living room with doubled floor joists above rec room
Gas Service Inspection - Residential Passed 7/7/2020 7/7/2020 07/07/2020
Misc
Resolved
07/07/2020
All Rough Inspection - Residential Failed 7/10/2020 7/10/2020 07/10/2020
Misc
Corrective Action Required
07/02/2020
- Provide PFH portal framing per plans - City approved plans show fireplace on cantilever in living room with doubled floor joists above rec room
All Rough Inspection - Residential Failed 7/14/2020 7/14/2020 07/14/2020
Misc
Resolved
07/14/2020
- Provide PFH portal framing per plans
All Rough Inspection - Residential Failed 07/14/2020
Misc
Corrective Action Required
07/14/2020
- Garage PFH per plans
All Rough Inspection - Residential Passed 7/16/2020 7/16/2020 07/16/2020
Misc
Resolved
07/16/2020
Driveway Inspection Partial 8/24/2020 (P.M.) 8/24/2020 08/24/2020
Misc
Informational
08/24/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 8/31/2020 8/31/2020 09/04/2020
Misc
Informational
08/24/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Occupancy Inspection - Codes Residential Failed 10/12/2020 10/12/2020 10/12/2020
Misc
Corrective Action Required
10/12/2020
-PROVIDE AS GRADED PLOT PLAN
Misc
Corrective Action Required
10/12/2020
-PAY ALL FEES BEFORE OCCUPANCY -PROVIDE AS GRADED PLOT PLAN -FINAL GRADE AND SOD -PROVIDE SPLASH BLOCKS/ PROPER DRAINAGE AWAY FROM FOUNDATION -PROVIDE GUARDRAIL OR RAISE ELEVATION OF GRADE AT SOUTH SIDE OF PORCH WHERE AT 30” ABOVE GRADE -ALL EXTERIOR LIGHT FIXTURES BELOW 8’ TO HAVE LIGHT SOURCE NOT READILY ACCESSIBLE -SECURE WHIP AT AC DISCONNECT WITHIN 12” -PROVIDE SECURITY SCREWS AT EXTERIOR DOORS -INSTALL RANGE VENT -MISSING COVER PLATES IN BASEMENT -COMPLETE ALL PLUMBING, ELECTRICAL AND MECHANICAL FIXTURES IN BASEMENT
Occupancy Inspection - Codes Residential Failed 10/14/2020 10/14/2020 10/14/2020
Misc
Resolved
10/14/2020
Misc
Corrective Action Required
10/12/2020
-PAY ALL FEES BEFORE FINAL OCCUPANCY -PROVIDE AS GRADED PLOT PLAN -FINAL GRADE AND SOD -PROVIDE SPLASH BLOCKS/ PROPER DRAINAGE AWAY FROM FOUNDATION -PROVIDE GUARDRAIL OR RAISE ELEVATION OF GRADE AT SOUTH SIDE OF PORCH WHERE AT 30” ABOVE GRADE -ALL EXTERIOR LIGHT FIXTURES BELOW 8’ TO HAVE LIGHT SOURCE NOT READILY ACCESSIBLE -INSTALL RANGE EXHAUST VENT
Occupancy Inspection - Codes Residential Temporary C of O 10/15/2020 10/15/2020 10/15/2020
Misc
Corrective Action Required
10/14/2020
-PAY ALL FEES BEFORE FINAL OCCUPANCY -PROVIDE AS GRADED PLOT PLAN -FINAL GRADE AND SOD -PROVIDE SPLASH BLOCKS/ PROPER DRAINAGE AWAY FROM FOUNDATION -PROVIDE GUARDRAIL OR RAISE ELEVATION OF GRADE AT SOUTH SIDE OF PORCH WHERE AT 30” ABOVE GRADE -ALL EXTERIOR LIGHT FIXTURES BELOW 8’ TO HAVE LIGHT SOURCE NOT READILY ACCESSIBLE
Plot Plan Inspection Failed 11/18/2020 11/18/2020
Misc
Corrective Action Required
11/18/2020
Locate and expose sanitary manhole in front yard as shown on plot
Occupancy Inspection - Codes Residential Temporary C of O 11/18/2020 11/18/2020 11/18/2020
Misc
Resolved
11/18/2020
-PAY ALL FEES BEFORE FINAL OCCUPANCY -PROVIDE AS GRADED PLOT PLAN -FINAL GRADE AND SOD -PROVIDE SPLASH BLOCKS/ PROPER DRAINAGE AWAY FROM FOUNDATION -PROVIDE GUARDRAIL OR RAISE ELEVATION OF GRADE AT SOUTH SIDE OF PORCH WHERE AT 30” ABOVE GRADE -ALL EXTERIOR LIGHT FIXTURES BELOW 8’ TO HAVE LIGHT SOURCE NOT READILY ACCESSIBLE
Misc
Corrective Action Required
11/18/2020
See plot plan inspection report 11/18/2020 -Locate and expose sanitary manhole in front yard as shown on plot -ONE WEEK EXTENSION OF INITIAL TCO VALID THROUGH MONDAY 11/23/2020
Occupancy Inspection - Codes Residential Failed 11/25/2020 11/25/2020 11/25/2020
Misc
Corrective Action Required
11/18/2020
Please request extension of TCO in writen form either by letter or email with date all items will be completed by. -Locate and expose sanitary manhole in front yard as shown on plot Manhole at property line is exposed and grade needs to be level with top of manhole or manhole needs to be raised and approved by the city of Lee's summit. -- Curd damaged at from of lot, curd needs to be repaired and inspected. -ONE WEEK EXTENSION OF INITIAL TCO VALID THROUGH MONDAY 11/23/2020 5 FINAL INSPECTIONS 9 ALL ROUGH INSPECTIONS. Note from contractor-"(Need more time to find man hole. Since its rained all week and holiday can you gimmie til like 12/8)
Occupancy Inspection - Codes Residential Failed 3/5/2021 3/5/2021 03/05/2021
Misc
Corrective Action Required
11/25/2020
-Locate and expose sanitary manhole 1-A7 in front yard as shown on plot
Occupancy Inspection - Codes Residential Failed 3/11/2021 3/11/2021 03/11/2021
Misc
Corrective Action Required
03/05/2021
-FINAL SOD AND GRADE AT MANHOLE IN FRONT YARD, ENSURE MANHOLE IS ACCESSIBLE AND AT FINISHED GRADE, ENSURE DRAINAGE PER APPROVED PLOT PLAN
Occupancy Inspection - Codes Residential Failed 3/12/2021 3/15/2021 03/16/2021
Misc
Corrective Action Required
03/11/2021
inspected 3/12- sod at manhole was addressed. House is pending re-inspection fees being added and paid. Discusion pending with Josh Kennison & Mark Harding. moving this to monday 3/15. MARK HARDING 03/12/2021 11:16 AM fees added no responce from SUmmit homes. MARK HARDING 03/16/2021 7:14 AM Pay fees and CofO will be issued.
Occupancy Inspection - Codes Residential Full C of O 3/23/2021 03/22/2021
Misc
Resolved
03/22/2021
inspected 3/12- sod at manhole was addressed. House is pending re-inspection fees being added and paid. Discusion pending with Josh Kennison & Mark Harding. moving this to monday 3/15. MARK HARDING 03/12/2021 11:16 AM fees added no responce from SUmmit homes. MARK HARDING 03/16/2021 7:14 AM Pay fees and CofO will be issued.
Documents & Images
Date Uploaded File Type Document Name
02/10/2020 Letter Codes Residential Plan Review
02/11/2020 Receipt Receipt for transaction: 2020-000550
02/11/2020 Letter DS Building Permit
02/11/2020 Plot Plan DOC021120-02112020111929
03/03/2020 Letter INSPECTION SUMMARY
04/01/2020 Letter INSPECTION SUMMARY
04/07/2020 Letter INSPECTION SUMMARY
04/08/2020 Letter INSPECTION SUMMARY
04/09/2020 Letter INSPECTION SUMMARY
04/14/2020 Letter INSPECTION SUMMARY
05/13/2020 Letter INSPECTION SUMMARY
06/15/2020 Letter INSPECTION SUMMARY
06/18/2020 Letter INSPECTION SUMMARY
06/24/2020 Letter INSPECTION SUMMARY
06/26/2020 Letter INSPECTION SUMMARY
06/26/2020 Letter INSPECTION SUMMARY
06/26/2020 Letter INSPECTION SUMMARY
06/26/2020 Letter INSPECTION SUMMARY
07/02/2020 Letter INSPECTION SUMMARY
07/07/2020 Letter INSPECTION SUMMARY
07/09/2020 25 Creekside at Raintree Main Floor Framing Letter
07/10/2020 Letter INSPECTION SUMMARY
07/13/2020 Plans APPROVED REVISED HOUSE PLANS
07/13/2020 Plans APPROVED REVISED ROOF TRUSS LAYOUT
07/14/2020 Letter INSPECTION SUMMARY
07/14/2020 Letter INSPECTION SUMMARY
07/16/2020 Letter INSPECTION SUMMARY
08/24/2020 Letter INSPECTION SUMMARY
09/04/2020 Letter INSPECTION SUMMARY
10/12/2020 Letter INSPECTION SUMMARY
10/14/2020 Letter INSPECTION SUMMARY
10/15/2020 Letter Codes Temporary Certificate of Occupancy
10/21/2020 Receipt Receipt for transaction:2020-007085
11/17/2020 Plot Plan APPROVED AS-BUILT
11/18/2020 Letter INSPECTION SUMMARY
11/18/2020 Letter Codes Temporary Certificate of Occupancy
11/25/2020 Letter INSPECTION SUMMARY
03/05/2021 Letter INSPECTION SUMMARY
03/11/2021 Letter INSPECTION SUMMARY
03/16/2021 Letter INSPECTION SUMMARY
03/22/2021 Receipt Receipt for transaction:2021-001420
03/22/2021 Letter Codes Final Certificate of Occupancy
03/22/2021 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home