Permit Application Status

PRCOMCOM20251165


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRCOMCOM20251165
Building Permit - Commercial
Temporary Occupancy
NEW MULTI-FAMILY
THE REUNION AT BLACKWELL - BUILDING 23, TYPE C -PLEX PLAN REVIEW COMPLETED UNDER PRCOM20250089
03/31/2025
06/17/2025
Locations
Contacts
Avital Homes, LLC, Address:7500 W 151st Street, #23100, Phone:(816) 914-7128  
RED DOG ELECTRIC SERVICES, Address:PO BOX 1, Phone:(913) 208-4816  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
COLLINS WEBB ARCHITECTURE LLC, Address:307 SW MARKET ST, Unit A, Phone:(816) 249-2270  
Doug Jenson - Avital Homes, Phone:(816) 266-0685  
Reviews
Review Type Outcome Est. Completion Date Completed
Final Development Plan Review Approved 04/14/2025 03/31/2025
Mike Weisenborn
Building Plan Review Approved with Conditions 04/14/2025 03/31/2025
Mike Weisenborn
Miscellaneous Correction
Resolved
06/17/2025

Foundation and underlsab plumbing only released at this time. Substantial completion on the santiary and water before private connections can be made. Full access and live hydrants required prior to release of vertical construction.
Licensed Contractors Approved 04/14/2025 03/31/2025
Mike Weisenborn
Fees
Paid Fees Amount Paid Owing Date Paid
Water Tap Fee $10,595.00 $10,595.00 Paid 04/03/2025
Water Meter Fee $1,066.76 $1,066.76 Paid 04/03/2025
Sanitary Sewer Development Fee $6,101.00 $6,101.00 Paid 04/03/2025
Valuation Fee for New 3 or 4 Family $4,451.71 $4,451.71 Paid 04/03/2025
Residential Excise Tax Fee $2,480.64 $2,480.64 Paid 04/03/2025
Not Ready Inspection Fee $75.00 $75.00 Paid 01/27/2026
Not Ready Inspection Fee $75.00 $75.00 Paid 01/27/2026
Not Ready Inspection Fee $75.00 $75.00 Paid 01/27/2026
Not Ready Inspection Fee $75.00 $75.00 Paid 01/27/2026
Not Ready Inspection Fee $75.00 $75.00 Paid 01/27/2026
Not Ready Inspection Fee $75.00 $75.00 Paid 01/27/2026
Not Ready Inspection Fee $75.00 $75.00 Paid 01/27/2026
Temporary Occupancy Fee $50.00 $50.00 Paid 02/13/2026
Outstanding Fees Amount Paid Owing Date Paid
Temporary Occupancy Fee $50.00 $0.00 $50.00 Not Paid


$50.00    Add Fees to My Cart
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Pending
PW-Devices for Erosion and Sediment Control
Corrective Action Required
11/10/2025
5-5-25 Dustin A, Erosion control had been installed and construction entrances are being installed.
Misc
Corrective Action Required
11/10/2025
-Silt fence downed throughout lot -dirt on top of storm box -
Occupancy Inspection - Engineering Pending
Miscellaneous Correction
Corrective Action Required
02/11/2026
2-11-26 Dustin A, Public sidewalk is not installed in rear of lot. Hydrant valve has been hit and laid over. Cannot get a hydrant key on it . Will need to be cut to final grade as well
Sidewalk Inspection Pending
Misc
Corrective Action Required
02/20/2026
2-12-26 Dustin A, sw has been formed and compacted . Approved to pour 2-20-26 Dustin A, cannot perform final sw inspection due to dirt on sidewalk and curb. Will need to call in and schedule when these are cleaned off. EROSION control must be in place if there is not sod down
Footing Inspection - Commercial Partial 4/23/2025 4/23/2025 04/23/2025
Misc
Informational
04/23/2025
Footings okay excluding grade beam. (Grade beam not dug)
Footing Inspection - Commercial Passed 4/24/2025 4/24/2025 04/24/2025
Misc
Resolved
04/24/2025
Footings okay excluding grade beam. (Grade beam not dug)
Footing Inspection - Commercial Passed 4/28/2025 04/28/2025
Misc
Informational
04/28/2025
Grade beam stem wall
Erosion Control Inspection Partial 5/5/2025 5/5/2025 05/05/2025
PW-Devices for Erosion and Sediment Control
Corrective Action Required
05/05/2025
5-5-25 Dustin A, Erosion control had been installed and construction entrances are being installed.
Underslab Plumbing Inspection - Commercial Failed 5/13/2025 5/13/2025 05/13/2025
Misc
Corrective Action Required
05/13/2025
Provide documentation showing compliance with sec 706 & 708 of the ipc
Underslab Plumbing Inspection - Commercial Passed 5/16/2025 5/16/2025 05/16/2025
Misc
Resolved
05/16/2025
Provide documentation showing compliance with sec 706 & 708 of the ipc
Rated Assembly Inspection Failed 6/30/2025 6/30/2025 06/30/2025
Misc
Corrective Action Required
06/30/2025
No inspection performed discussed with contractor on site
Sewer Service Inspection Passed 7/18/2025 7/18/2025 07/18/2025
Misc
Corrective Action Required
07/18/2025
7-18-25 Dustin A, both sewer stubs for duplex are attached to existing 6 in sewer stub. Pass
All Rough Inspection - Commercial Failed 7/24/2025 7/24/2025 07/24/2025
Misc
Corrective Action Required
07/24/2025
Not a complete inspection -Provide city stamped truss plans on site -Remove all insulation -complete electrical -seal all penetrations in top plates -outlet spacing to comply with code section figure E3901.2 -anchor bolts to be in the middle 1/3 of sill plate -provide Boca plate protection for dryer vents at top plate -provide 2hr rated electrical boxes at party wall -install putty packs where required per design
All Rough Inspection - Commercial Failed 7/31/2025 7/31/2025 07/31/2025
Misc
Corrective Action Required
07/24/2025
Not a complete inspection complete all items for re-inspection -Remove all insulation -complete electrical -seal all penetrations in top plates -outlet spacing to comply with code section figure E3901.2 -anchor bolts to be in the middle 1/3 of sill plate -anchor bolts to be within 12” of plate breaks but not closer than 7x the diameter of the bolt -protect dryer vents at top plate and extend 2” below plate -provide 2hr rated electrical boxes at party wall -install putty packs where required per design -provide blocking on sheathing breaks -provide wet rated conductors to under slab electrical -no more than 2 NM to penetrate together through holes -repair all holes and gaps in rated wall -fire rated roof sheathing needs to extend 4’ either side of rated wall -rated wall to be contentious from floor to ceiling -complete all bracing per truss and structural plans -screw rated wall to ul design 8” OC -protect all electrical within 6’ of attic access
All Rough Inspection - Commercial Not Ready 8/20/2025 8/20/2025 08/20/2025
Misc
Corrective Action Required
07/31/2025
Not a complete inspection complete all items for re-inspection -complete electrical -seal all penetrations in top plates (check throughout -outlet spacing to comply with code section figure E3901.2 (not done check throughout) -anchor bolts to be in the middle 1/3 of sill plate -anchor bolts to be within 12” of plate breaks but not closer than 7x the diameter of the bolt -install putty packs where required per design (all outlets in separating walls will require box extenders, boxes are set flush with first layer, putty packs will need to extend over box extenders or set boxes to be no more than 1/4” from finish surface) -repair all holes and gaps in rated wall -fire rated roof sheathing needs to extend 4’ either side of rated wall (provide documentation for fix) -complete all bracing per truss and structural plans will check at re inspection -screw rated wall to ul design 8” OC -protect all electrical within 6’ of attic access( not done check throughout )
All Rough Inspection - Commercial Failed 8/25/2025 8/25/2025 08/25/2025
Misc
Corrective Action Required
08/20/2025
All units -outlet spacing to comply with code section figure E3901.2 (not done check throughout) -repair all holes and gaps in rated wall -go bracing (will check when completed after all rough) -seal gaps in 4’fire rated roof at vented ridge cap 626 -flex duct can not be supported by NM -wall in living room back side of laundry outlet missing -provide hvac service outlet 628 -remove truss bracing where extended into separation wall -seal dead space at kitchen/bathroom -provide nail guards above service panel -replace broken outlet at separation wall primary bedroom 630 632 -provide hvac service outlet
Water Service Inspection Passed 8/25/2025 08/25/2025
Misc
Informational
08/25/2025
8-20-25 Dustin A, Water service is in and pit is installed to city specs
All Rough Inspection - Commercial Not Ready 8/27/2025 8/27/2025 08/27/2025
Misc
Corrective Action Required
08/25/2025
All units -go bracing (will check when completed after all rough) -seal gaps in 4’fire rated roof at vented ridge 626 -provide hvac service outlet at exterior -outlet spacing to comply with code section figure E3901.2 (not done check throughout) 628 -provide nail guards above service panel -seal penetrations in vertical to horizontal fire blocking 630 -bath vent disconnected at rear -outlet spacing to comply with code section figure E3901.2 (not done check throughout) 632 -provide hvac service outlet at exterior
All Rough Inspection - Commercial Failed 8/29/2025 8/29/2025 08/29/2025
Misc
Corrective Action Required
08/27/2025
All units -gb bracing (will check when completed after all rough) 626 -outlet spacing to comply with code section figure E3901.2 (check back bedroom) 628 630 632
Electrical Service Inspection Failed 8/29/2025 8/29/2025 08/29/2025
Misc
Corrective Action Required
08/29/2025
-replace damaged wire sheathing in main disconnect panel -provide electrical plans onsite -label/address at all meters/main disconnects -land grounding electrode conductor to neutral
All Rough Inspection - Commercial Not Ready 9/2/2025 9/2/2025 09/02/2025
Misc
Corrective Action Required
08/29/2025
All units -gb bracing (will check when completed after all rough) 626 -outlet spacing to comply with code section figure E3901.2 (check back bedroom) not done 628 630 632
All Rough Inspection - Commercial Partial 9/3/2025 9/3/2025 09/03/2025
Misc
Corrective Action Required
09/02/2025
OKAY to insulate All units -gb bracing (will check when completed after all rough)
Electrical Service Inspection Passed 9/18/2025 9/18/2025 09/18/2025
Misc
Resolved
09/18/2025
-replace damaged wire sheathing in main disconnect panel -provide electrical plans onsite -label/address at all meters/main disconnects
Rated Assembly Inspection Failed 9/26/2025 9/26/2025 09/26/2025
Misc
Corrective Action Required
06/30/2025
No inspection performed. -No plans on site -Drywall on party walls still being hung
Rated Assembly Inspection Not Ready 9/29/2025 9/29/2025 09/29/2025
Misc
Corrective Action Required
09/26/2025
provide city stamp plans on site for inspection -studs facing on GB wall not to be greater than 16 inch on center -uncover covered furr out walls covering party walls -complete all GB walls -complete screw pattern on party walls (missing top edges, check all screw spacing throughout)
Rated Assembly Inspection Partial 10/2/2025 10/2/2025 10/02/2025
Misc
Corrective Action Required
09/29/2025
provide city stamp plans on site for inspection -studs facing on GB wall not to be greater than 16 inch on center -uncover covered furr out walls covering party walls -complete all GB walls -complete screw pattern on party walls (missing top edges, check all screw spacing throughout)
Misc
Informational
10/02/2025
Screw pattern on party walls ok
Rated Assembly Inspection Failed 10/9/2025 10/9/2025 10/09/2025
Misc
Corrective Action Required
10/02/2025
provide city stamp plans on site for inspection(city stamped plans on site not useable, multiple staples stapling all pages together) -complete all GB walls missing screws in areas -fire caulk penetrations in party wall -offset horizontal seams to listing
Misc
Resolved
10/09/2025
Screw pattern on party walls ok
Rated Assembly Inspection Not Ready 10/15/2025 10/15/2025 10/15/2025
Misc
Corrective Action Required
10/09/2025
Inspection denied, work still. Being performed provide city stamp plans on site for inspection(city stamped plans on site not useable, multiple staples stapling all pages together) -complete all GB walls missing screws in areas -fire caulk penetrations in party wall -offset horizontal seams to listing
Rated Assembly Inspection Partial 10/16/2025 10/16/2025 10/16/2025
Misc
Corrective Action Required
10/15/2025
Pull scab pieces away from separation wall to allow for sheet rock on party wall in attic space -complete all GB wall N unit -fire caulk penetrations in party wall -complete 2nd layer
Rated Assembly Inspection Partial 10/22/2025 10/22/2025 10/22/2025
Misc
Corrective Action Required
10/16/2025
-fire caulk penetrations in party wall attic pace -mud and tape 2nd layer main floor
Rated Assembly Inspection Partial 10/24/2025 10/24/2025 10/24/2025
Misc
Corrective Action Required
10/22/2025
address front soffit between center two units (soffit space traveling from unit to unit -mud and tape 2nd layer main floor
Rated Assembly Inspection Not Ready 10/28/2025 10/28/2025 10/28/2025
Misc
Corrective Action Required
10/24/2025
address front soffit between center two units (soffit space traveling from unitM630 to unit 628(628 NOT TAPED) -mud and tape 2nd layer main floor
Rated Assembly Inspection Not Ready 11/10/2025 11/10/2025 11/10/2025
Misc
Corrective Action Required
10/28/2025
Inspection denied erosion control not in compliance address front soffit between center two units (soffit space traveling from unitM630 to unit 628(628 NOT TAPED) -mud and tape 2nd layer main floor
Erosion Control Inspection Failed 11/10/2025 11/10/2025 11/10/2025
PW-Devices for Erosion and Sediment Control
Corrective Action Required
05/05/2025
5-5-25 Dustin A, Erosion control had been installed and construction entrances are being installed.
Misc
Corrective Action Required
11/10/2025
-Silt fence downed throughout lot -dirt on top of storm box -
Rated Assembly Inspection Passed 11/10/2025 11/10/2025 11/10/2025
Misc
Resolved
11/10/2025
Inspection denied erosion control not in compliance address front soffit between center two units (soffit space traveling from unitM630 to unit 628(628 NOT TAPED) -mud and tape 2nd layer main floor
Driveway Inspection Failed 11/24/2025 11/24/2025 11/24/2025
Misc
Corrective Action Required
11/24/2025
11-24-25 Dustin A, Dw has standing water and has not been compacted.
Driveway Inspection Partial 12/8/2025 12/8/2025 12/08/2025
Misc
Corrective Action Required
11/24/2025
11-24-25 Dustin A, Dw has standing water and has not been compacted. 12-8-25 Dustin A, Dw has been compacted and is free of standing water. Approved to pour ( Reminder ground temp must be 32 deg and rising )
Driveway Inspection Partial 12/15/2025 12/15/2025 12/15/2025
Misc
Corrective Action Required
12/08/2025
11-24-25 Dustin A, Dw has standing water and has not been compacted. 12-8-25 Dustin A, Dw has been compacted and is free of standing water. Approved to pour ( Reminder ground temp must be 32 deg and rising )
Driveway Inspection Passed 12/22/2025 12/22/2025 12/22/2025
Misc
Corrective Action Required
12/15/2025
11-24-25 Dustin A, Dw has standing water and has not been compacted. 12-8-25 Dustin A, Dw has been compacted and is free of standing water. Approved to pour ( Reminder ground temp must be 32 deg and rising ) 12-22-25 Dustin A, Dw is poured to city specs.
All Rough Inspection - Commercial Passed 11/18/2025 02/05/2026
Misc
Resolved
02/05/2026
OKAY to insulate All units -gb bracing (will check when completed after all rough) -label/address at all meters/main disconnects
Occupancy Inspection - Codes Residential Failed 2/5/2026 2/5/2026 02/05/2026
Misc
Corrective Action Required
02/05/2026
-lot not graded -Final grade (no plot plan on permit) -sod -splash blocks to extend 36” from foundation -secure A/c whips -address disconnects outside -land sewer tracer wire -provide access to ufer ground connection 632,630,628, 626 -provide spark rings/ box extenders throughout entire unit where needed (leave face plates off in front of outlets where added) -laundry outlet to be GFCI protected -provide lock out for all hardwired appliances not in view of panel -afci protection missing for multiple circuits (laundry,fridge,microwave,smokes) -security screws at exterior doors require 2 per hinge and strike plate -provide floodlight at rear per Lees Summit chapter 7 security code 628 -garage door to be self closing and latching 626 -label unidentified breaker
Occupancy Inspection - Codes Residential Failed 2/10/2026 2/10/2026 02/10/2026
Misc
Corrective Action Required
02/05/2026
EROSION CONTROL TO REMAIN IN PLACE UNTIL TIME OF SOD. NO FURTHER INSPECTIONS UNTIL EROSION CONTROL IN COMPLIANCE -lot not graded -Final grade (no plot plan on permit) -sod -splash blocks to extend 36” from foundation -land sewer tracer wires 632,630,628, 626 -all laundry outlets to be GFCI protected -afci protection missing for fridge circuit 632 -missing spark rings at kitchen counter top backsplash
Occupancy Inspection - Engineering Failed 2/11/2026 2/11/2026 02/11/2026
Miscellaneous Correction
Corrective Action Required
02/11/2026
2-11-26 Dustin A, Public sidewalk is not installed in rear of lot. Hydrant valve has been hit and laid over. Cannot get a hydrant key on it . Will need to be cut to final grade as well
Occupancy Inspection - Codes Commercial Failed 2/11/2026 2/11/2026 02/11/2026
Miscellaneous Correction
Corrective Action Required
02/10/2026
EROSION CONTROL TO REMAIN IN PLACE UNTIL TIME OF SOD. -sod -splash blocks to extend 36” from foundation -land sewer tracer wires 626,628,630,632 -AC breaker not to exceed max breaker size of unit 632 -all laundry outlets to be GFCI protected (no power will check at reinspection) -missing spark rings at kitchen counter top backsplash
Sidewalk Inspection Partial 2/12/2026 2/12/2026 02/12/2026
Misc
Corrective Action Required
02/12/2026
2-12-26 Dustin A, sw has been formed and compacted . Approved to pour
Occupancy Inspection - Codes Commercial Ready for Temp CO 2/13/2026 2/13/2026 02/13/2026
Miscellaneous Correction
Corrective Action Required
02/11/2026
EROSION CONTROL TO REMAIN IN PLACE UNTIL TIME OF SOD. -sod -splash blocks to extend 36” from foundation
Sidewalk Inspection Failed 2/20/2026 2/20/2026 02/20/2026
Misc
Corrective Action Required
02/12/2026
2-12-26 Dustin A, sw has been formed and compacted . Approved to pour 2-20-26 Dustin A, cannot perform final sw inspection due to dirt on sidewalk and curb. Will need to call in and schedule when these are cleaned off. EROSION control must be in place if there is not sod down
Occupancy Inspection - Codes Commercial Ready for Temp CO 3/16/2026 03/16/2026
Miscellaneous Correction
Corrective Action Required
02/13/2026
EROSION CONTROL TO REMAIN IN PLACE UNTIL TIME OF SOD. -sod -splash blocks to extend 36” from foundation
Documents & Images
Date Uploaded File Type Document Name
04/03/2025 Receipt Receipt for transaction:2025-002032
04/03/2025 Letter DS Building Permit
03/31/2025 Approved Plans Approved plans V1
04/23/2025 Letter INSPECTION SUMMARY
04/24/2025 Letter INSPECTION SUMMARY
04/28/2025 Letter INSPECTION SUMMARY
05/05/2025 Letter INSPECTION SUMMARY
05/13/2025 Letter INSPECTION SUMMARY
05/16/2025 Letter INSPECTION SUMMARY
06/17/2025 Letter DS Building Permit
06/30/2025 Letter INSPECTION SUMMARY
07/18/2025 Letter INSPECTION SUMMARY
03/31/2025 Approved Plans Approved plans V1
03/06/2025 Approved Plans Approved plans V2
07/24/2025 Letter INSPECTION SUMMARY
07/31/2025 Letter INSPECTION SUMMARY
08/20/2025 Letter INSPECTION SUMMARY
08/25/2025 Letter INSPECTION SUMMARY
08/25/2025 Letter INSPECTION SUMMARY
08/25/2025 Letter INSPECTION SUMMARY
08/27/2025 Letter INSPECTION SUMMARY
08/29/2025 Letter INSPECTION SUMMARY
08/29/2025 Letter INSPECTION SUMMARY
09/02/2025 Letter INSPECTION SUMMARY
09/18/2025 Letter INSPECTION SUMMARY
09/26/2025 Letter INSPECTION SUMMARY
09/26/2025 Letter INSPECTION SUMMARY
09/29/2025 Letter INSPECTION SUMMARY
10/02/2025 Letter INSPECTION SUMMARY
10/09/2025 Letter INSPECTION SUMMARY
10/15/2025 Letter INSPECTION SUMMARY
10/16/2025 Letter INSPECTION SUMMARY
10/17/2025 Approved Plans Approved Bldg C Trusses
10/17/2025 Approved Plans Approved Bldg C Trusses
10/17/2025 Approved Plans Building C truss Seals All C buildngs_STAND REVIEWED
10/22/2025 Letter INSPECTION SUMMARY
11/05/2025 Approved Plans Approved G111
11/10/2025 Letter INSPECTION SUMMARY
11/10/2025 Letter INSPECTION SUMMARY
11/10/2025 Letter INSPECTION SUMMARY
11/10/2025 Letter INSPECTION SUMMARY
11/10/2025 Letter INSPECTION SUMMARY
11/12/2025 Approved Plans Approved Truss repair
11/17/2025 Approved Plans Truss repair doc
11/24/2025 Letter INSPECTION SUMMARY
12/08/2025 Approved Plans Approved E200 revision
12/08/2025 Letter INSPECTION SUMMARY
12/08/2025 Letter INSPECTION SUMMARY
12/15/2025 Letter INSPECTION SUMMARY
12/22/2025 Letter INSPECTION SUMMARY
01/27/2026 Receipt Receipt for transaction:2026-000528
02/05/2026 Letter INSPECTION SUMMARY
02/05/2026 Letter INSPECTION SUMMARY
02/09/2026 Approved Plans REUNION GRADING PLA
02/10/2026 Letter INSPECTION SUMMARY
02/11/2026 Letter INSPECTION SUMMARY
02/11/2026 Letter INSPECTION SUMMARY
02/11/2026 Letter INSPECTION SUMMARY
02/12/2026 Letter INSPECTION SUMMARY
02/13/2026 Letter INSPECTION SUMMARY
02/13/2026 Certificate/License Codes Temporary Certificate of Occupancy
02/13/2026 Receipt Receipt for transaction:2026-000867
02/20/2026 Letter INSPECTION SUMMARY
02/20/2026 Letter INSPECTION SUMMARY
03/16/2026 Application Form Building 23C TCO extension form
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home