Permit Application Status

PRRES20244406


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20244406
Building Permit - Residential
Certificate of Occupancy
WALKER CUSTOM HOMES LLC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED DECK STOP WORK ORDER generated on 01/31/2025 12:00 AM by username 'Kyle Beard'. STOP WORK ORDER removed on 01/31/2025 12:00 AM by username 'Kyle Beard'.
08/20/2024
09/18/2024
02/18/2025
06/12/2025
Locations
Contacts
WALKER CUSTOM HOMES, LLC, Address:PO BOX 3194, Phone:(913) 208-2026  
WALKER CUSTOM HOMES LLC, Address:PO BOX 247  
Jason walker, Address:PO Box 247, Phone:(913) 208-2026  
WALKERCUSTOMHOMESKC@GMAIL.COM  
  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
TRI-COUNTY PLUMBING LLC, Address:PO BOX 234, Phone:(816) 720-3222  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sanitary Sewer Development Fee $2,285.00 $2,285.00 Paid 09/18/2024
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 09/18/2024
7232302-Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 09/18/2024
8331401-Water Tap Fee $3,973.00 $3,973.00 Paid 09/18/2024
8350015-Water Meter Fee $748.03 $748.03 Paid 09/18/2024
9110078-Valuation Fee New Single Family $2,185.02 $2,185.02 Paid 09/18/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Failed 10/09/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
10/09/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -maintain silt fence -maintain overgrown vegetation
Underslab Plumbing Inspection - Residential Failed 10/9/2024 10/9/2024 10/09/2024
Misc
Corrective Action Required
10/09/2024
Inspection denied. Maintain erosion control before calling for re-inspection
Underslab Plumbing Inspection - Residential Passed 10/11/2024 10/11/2024 10/11/2024
Misc
Resolved
10/11/2024
Inspection denied. Maintain erosion control before calling for re-inspection
Erosion Control Inspection Residential Partial 10/11/2024 10/11/2024 10/11/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
10/11/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -maintain silt fence -maintain overgrown vegetation
Misc
Informational
10/11/2024
Erosion control in compliance at time of inspection
Sewer Service Inspection - R Passed 10/17/2024 10/17/2024 10/17/2024
Erosion Control Inspection Residential Partial 10/17/2024 10/17/2024 10/17/2024
Misc
Informational
10/11/2024
Erosion control in compliance at time of inspection
Water Service Inspection - R Passed 10/18/2024 10/18/2024
All Rough Inspection - Residential Partial 12/9/2024 12/9/2024 12/09/2024
Misc
Informational
12/09/2024
Garage portal frame nailing inspection only. Okay to cover
Erosion Control Inspection Residential Failed 01/29/2025
Misc
Resolved
01/29/2025
Erosion control in compliance at time of inspection
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
01/29/2025
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. PROVIDE GRAVEL ENTRANCE REPAIR SILT FENCE CLEAN STREET
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
01/29/2025
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
All Rough Inspection - Residential Failed - Stop Work 1/31/2025 1/31/2025 01/31/2025
Misc
Informational
12/09/2024
Garage portal frame nailing inspection only. Okay to cover
Miscellaneous Correction
Corrective Action Required
01/31/2025
Footing report was never uploaded. Stop work order issued
Gas Service Inspection - Residential Passed 1/31/2025 1/31/2025 01/31/2025
Electrical Service Inspection Passed 1/31/2025 1/31/2025 01/31/2025
All Rough Inspection - Residential Failed 1/31/2025 01/31/2025
Misc
Resolved
01/31/2025
Garage portal frame nailing inspection only. Okay to cover
Miscellaneous Correction
Resolved
01/31/2025
Footing report was never uploaded. Stop work order issued
Miscellaneous Correction
Corrective Action Required
01/31/2025
-Have engineers letter address hole drilled in double car garage LVL header -Jack studs at bottom plate have been over bored at double car garage west side -Protect electrical within 6 feet of garage attic access hatch -Holes are in the floor of the garage entry powder bathroom -Protect electrical within 6 feet of attic access hatch to main roof -Some fire blocking is missing above basement IBeam -Water lines in basement can not run through HVAC panning below garage entry bathroom
All Rough Inspection - Residential Passed 2/7/2025 2/7/2025 02/07/2025
Miscellaneous Correction
Resolved
02/07/2025
-Have engineers letter address hole drilled in double car garage LVL header -Jack studs at bottom plate have been over bored at double car garage west side -Protect electrical within 6 feet of garage attic access hatch -Holes are in the floor of the garage entry powder bathroom -Protect electrical within 6 feet of attic access hatch to main roof -Some fire blocking is missing above basement IBeam -Water lines in basement can not run through HVAC panning below garage entry bathroom
Footing Inspection - Residential Passed 02/07/2025
Driveway Inspection Partial 4/29/2025 04/29/2025
Misc
Informational
04/29/2025
04-29-25 Jamie S, DW is formed and compacted. Approved to pour.
Driveway Inspection Partial 5/6/2025 5/6/2025 05/06/2025
Misc
Informational
04/29/2025
04-29-25 Jamie S, DW is formed and compacted. Approved to pour. 05-06-25 Jamie S, DW is in compliance with city standards.
Plot Plan Inspection Failed 6/2/2025 06/02/2025
Misc
Corrective Action Required
06/02/2025
As graded plot plan needed
Plot Plan Inspection Failed 6/6/2025 06/02/2025
Misc
Corrective Action Required
06/02/2025
As graded plot plan needed
Erosion Control Inspection Residential Failed 2/5/2025 6/2/2025 06/02/2025
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
01/29/2025
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. PROVIDE GRAVEL ENTRANCE REPAIR SILT FENCE CLEAN STREET
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
01/29/2025
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
Misc
Corrective Action Required
06/02/2025
No perimeter protection in place at time of inspection
Occupancy Inspection - Codes Residential Failed 6/2/2025 6/2/2025 06/02/2025
Corrective Action Required
06/02/2025
2314 SW Serena pl - As graded plot plan needed - Erosion control not in place - Driveway inspection needed - No address posted - Barrier/railing needed on front porch - Flood light missing on rear on house - Seal penetrations on exterior of house - Escape ladder needed in window well - Caulk needed around AC disconnect and meter box - Sod and splash blocks need installed - Sewer tracer wire needs to be landed in box - Walkout door to garage must be self closing
Driveway Inspection Passed 6/2/2025 6/2/2025 06/02/2025
Misc
Informational
05/06/2025
04-29-25 Jamie S, DW is formed and compacted. Approved to pour. 05-06-25 Jamie S, DW is in compliance with city standards.
Plot Plan Inspection Passed 6/12/2025 06/12/2025
Misc
Corrective Action Required
06/02/2025
As graded plot plan needed
Erosion Control Inspection Residential Passed 6/12/2025 06/12/2025
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
06/02/2025
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. PROVIDE GRAVEL ENTRANCE REPAIR SILT FENCE CLEAN STREET
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
06/02/2025
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
Misc
Corrective Action Required
06/02/2025
No perimeter protection in place at time of inspection
Occupancy Inspection - Codes Residential Full C of O 6/12/2025 6/12/2025 06/12/2025
Documents & Images
Date Uploaded File Type Document Name
08/20/2024 2314 SW Serena Signed City Permit Application
08/21/2024 Permit Codes Residential Plan Review
08/21/2024 Application Form APPROVED PLANS
08/22/2024 5 star mechanical correction
08/22/2024 Permit Codes Residential Plan Review
08/29/2024 Permit Codes Residential Plan Review
08/29/2024 Plot Plan APPROVED PLOT PLAN
09/18/2024 Permit DS Building Permit
09/18/2024 Receipt Receipt for transaction:2024-007750
10/08/2024 Footing-2314 SW Serena Pl_
10/09/2024 Letter INSPECTION SUMMARY
10/09/2024 Letter INSPECTION SUMMARY
10/11/2024 Letter INSPECTION SUMMARY
10/11/2024 Letter INSPECTION SUMMARY
10/17/2024 Letter INSPECTION SUMMARY
10/17/2024 Letter INSPECTION SUMMARY
10/17/2024 Letter INSPECTION SUMMARY
10/18/2024 Letter INSPECTION SUMMARY
11/04/2024 3RD Party Insp Report THIRD PARTY DECK PIER INSPECTION
12/09/2024 Letter INSPECTION SUMMARY
01/29/2025 Letter INSPECTION SUMMARY
01/31/2025 Letter Stop Work Order
01/31/2025 Letter INSPECTION SUMMARY
01/31/2025 Letter INSPECTION SUMMARY
01/31/2025 Letter INSPECTION SUMMARY
02/03/2025 Engineer Report/Study 2314 SW Serena Place - Structural Letter (February 3, 2025)
02/07/2025 Letter INSPECTION SUMMARY
02/07/2025 Letter INSPECTION SUMMARY
04/29/2025 Letter INSPECTION SUMMARY
05/06/2025 Letter INSPECTION SUMMARY
06/02/2025 Letter INSPECTION SUMMARY
06/02/2025 Letter INSPECTION SUMMARY
06/02/2025 Letter INSPECTION SUMMARY
06/02/2025 Letter INSPECTION SUMMARY
06/02/2025 Letter INSPECTION SUMMARY
06/05/2025 LOT 78 ASBUILT
06/05/2025 Plot Plan APPROVED AS GRADED PLOT PLAN
06/12/2025 Letter INSPECTION SUMMARY
06/12/2025 Letter INSPECTION SUMMARY
06/12/2025 Letter Codes Final Certificate of Occupancy
06/12/2025 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home