PRRES20241493
Building Permit - Residential
Issued
NEW SINGLE FAMILY
NEW HOUSE. FINISHED/UNFINISHED BASEMENT. WALKOUT BASEMENT. SUSPENDED SLAB. ENGINEERED FLOOR SYSTEM. COVERED DECK. **Minor plat must be recorded prior to certificate of occupancy. Andrea Sessler 04/17/2024 4:08 PM STOP WORK ORDER generated on 06/14/2024 12:00 AM by username 'Robb Popp'. STOP WORK ORDER removed on 06/19/2024 12:00 AM by username 'Robb Popp'.
03/28/2024
04/18/2024
10/01/2024
Locations
Contacts
PFEIFER HOMES INC, Address:1550 SW MARKET ST STE 210, Phone:(816) 524-5245  
Rick holbrook , Address:528 NW. AA Highway  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
CENTURY PLUMBING, Address:14001 CENTURY LN, Phone:(816) 765-6066  
ANTHONY@PFEIFERHOMES.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Water Tap Fee $3,760.00 $3,760.00 Paid 04/15/2024
Water Meter Fee $680.46 $680.46 Paid 04/15/2024
Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 04/15/2024
Right of Way Permit Fee $85.00 $85.00 Paid 04/15/2024
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 04/15/2024
Valuation Fee New Single Family $2,367.09 $2,367.09 Paid 04/15/2024
Outstanding Fees Amount Paid Owing Date Paid
Not Ready Inspection Fee $75.00 $0.00 $75.00 Not Paid


$75.00    Add Fees to My Cart
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Driveway Inspection Pending
Plot Plan Inspection Pending
Occupancy Inspection - Codes Residential Pending
Sidewalk Inspection Pending
Sidewalk Inspection Pending
Erosion Control Inspection Residential Pending
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
02/10/2025
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -Clean silt and debris from street
Underslab Plumbing Inspection - Residential Failed 6/14/2024 6/14/2024 06/14/2024
Misc
Corrective Action Required
06/14/2024
6/14/24 No footing inspection or engineered piers on record. No inspection performed. Stop work issued
Erosion Control Inspection Residential Failed 06/14/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
06/14/2024
6/14/24 DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -RESTORE SILT FENCE AND CLEAN SILT FROM STREET
Footing Inspection - Residential Failed - Stop Work 06/14/2024
Misc
Corrective Action Required
06/14/2024
FOOTING AND PIERS REQUIRED PER ENGINEERED LETTER DATED 4/18/24 POURED WITHOUT INSPECTION. STOP WORK ORDER ISSUED. ALL THIRD PARTY INSPECTIONS MUST BE UPLOADED WITHIN 24 HOURS OF INSPECTIONS
Erosion Control Inspection Residential Failed 6/19/2024 6/19/2024 06/19/2024
DCM2 ESC DEFICIENT INSTALLATION
Resolved
06/19/2024
6/19/24 DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -CLEAN SILT FROM STREET IN FRONT OF LOT AND PROTECT STORM INLET
Erosion Control Inspection Residential Failed 06/19/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
06/19/2024
6/19/24 DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -CLEAN SILT FROM STREET IN FRONT OF DRIVE AND PROTECT STORM INLET
Footing Inspection - Residential Passed 6/19/2024 6/19/2024 06/19/2024
Misc
Informational
06/19/2024
FOOTING APPROVED BY MICHAEL SKEENS ON 4/23/24
Underslab Plumbing Inspection - Residential Passed 6/19/2024 06/19/2024
Misc
Resolved
06/19/2024
6/14/24 No footing inspection or engineered piers on record. No inspection performed. Stop work issued
Sewer Service Inspection - R Passed 6/21/2024 6/21/2024 06/21/2024
Erosion Control Inspection Residential Failed 06/21/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
06/19/2024
6/21/24 DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -CLEAN SILT FROM STREET IN FRONT OF DRIVE AND PROTECT STORM INLET
Water Service Inspection - R Partial 6/24/2024 6/24/2024 06/24/2024
Misc
Corrective Action Required
06/24/2024
Poly out of foundation
Water Service Inspection - R Passed 6/25/2024 06/25/2024
Misc
Resolved
06/25/2024
All Rough Inspection - Residential Failed 11/8/2024 11/8/2024 11/08/2024
Miscellaneous Correction
Corrective Action Required
11/08/2024
Garage PFH sheeting break should be located within 24 inches of the middle 1/3 of garage portal leg This inspection was for a garage PFH only
Erosion Control Inspection Residential Failed 12/11/2024 12/11/2024 12/11/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
06/21/2024
12/11/24 -Clean debris from street
All Rough Inspection - Residential Failed 12/11/2024 12/11/2024 12/11/2024
Miscellaneous Correction
Corrective Action Required
11/08/2024
Garage PFH sheeting break should be located within 24 inches of the middle 1/3 of garage portal leg This inspection was for a garage PFH only
Misc
Corrective Action Required
12/11/2024
12/11/24 -Inspection denied. No address posted. -Clean debris from street
All Rough Inspection - Residential Not Ready 12/18/2024 12/18/2024 12/18/2024
Miscellaneous Correction
Corrective Action Required
12/11/2024
Garage PFH sheeting break should be located within 24 inches of the middle 1/3 of garage portal leg This inspection was for a garage PFH only
Misc
Corrective Action Required
12/11/2024
12/11/24 -Inspection denied. No address posted. -Clean debris from street 12/18/24 -No change, inspection denied, fee assessed
Erosion Control Inspection Residential Failed 1/24/2025 1/24/2025 01/24/2025
DCM2 ESC DEFICIENT INSTALLATION
Resolved
01/24/2025
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
01/24/2025
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -Re establish erosion control methods at perimeter, Maintain gravel filter with min 6" lift of min 3/4" gravel
All Rough Inspection - Residential Failed 1/24/2025 1/24/2025 01/24/2025
Miscellaneous Correction
Resolved
01/24/2025
Misc
Informational
01/24/2025
Exterior PFH ONLY approved to cover
All Rough Inspection - Residential Failed 1/29/2025 1/29/2025 01/29/2025
Misc
Informational
01/24/2025
Exterior PFH ONLY approved to cover
Misc
Corrective Action Required
01/29/2025
- Fire block top of fireplace in hearth room - Strap all over board top plates on bearing wall at laundry and powder room - Anchor bolts to be in middle third of sill plate at garage street side - Hold down strap on portal frame missing on double door near single bay - Purlin struts to be 4’ OC throughout - Valleys rafters not supposed at ridge in garage - Provide straps on load bearing wall with over board for DWV in prep kitchen - Add studs to 14” LVL above top plate to carry loads as below at kitchen/ prep kitchen - Repair top plate at hallway entrance to mast suite - Strap top plate in master bathroom vanity wall were over bored on bearing wall - Unable to inspect framing of porch or deck cover ( covered) - Provide post caps or other means to secure the 2 part 6x6 post at deck beam - No suspended slab inspection on file - Fire block penetration in top plate basement wall at furnace - Vent basement laundry to outside - Fire block top of dead space at bedroom 2 shower - Minimum of 3 studs on all exterior corners in bedroom 2 return wall not full length stud - Anchor steel columns throughout - Fire block chase in bedroom 4 closet at top plate - Fire block top of chase at shower between bedroom 3/4 - Replace vertical fire blocking in basement bedrooms with approved material -
Gas Service Inspection - Residential Passed 1/29/2025 1/29/2025 01/29/2025
Electrical Service Inspection Passed 1/29/2025 1/29/2025 01/29/2025
Erosion Control Inspection Residential Failed 2/10/2025 2/10/2025 02/10/2025
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
02/10/2025
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -Re establish erosion control methods at perimeter, Maintain gravel filter with min 6" lift of min 3/4" gravel
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
02/10/2025
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -Clean silt and debris from street
All Rough Inspection - Residential Failed 2/10/2025 2/10/2025 02/10/2025
Misc
Informational
01/29/2025
Exterior PFH ONLY approved to cover
Misc
Corrective Action Required
01/29/2025
- Fire block top of fireplace in hearth room -SEAL GAPS - Strap all over board top plates on bearing wall at laundry and powder room-BOTH SIDES AND MISSING AT RADON - Purlin struts to be 4’ OC throughout-OVER 4’ AT MASTER BED AND HALLWAY OFF OF GARAGE - Provide straps on load bearing wall with over board for DWV in prep kitchen-STRUCTURAL STRAPS TO EXTEND 6” EACH WAY OF HOLES AND HAVE MIN (4) 10D NAILS EACH SIDE - Strap top plate in master bathroom vanity wall were over bored on bearing wall-NOT DONE (2) LOCATIONS - Unable to inspect framing of porch or deck cover ( covered) - No suspended slab inspection on file-ADDRESS BEFORE ANY RE INSPECTION - Vent basement laundry to outside - Fire block top of dead space at bedroom 2 shower-SEAL GAPS - Minimum of 3 studs on all exterior corners in bedroom 2-PROTECT NM IN CLOSET - Fire block chase in bedroom 4 closet at top plate-SEAL GAPS - Fire block top of chase at shower between bedroom 3/4-SEAL GAPS - Replace vertical fire blocking in basement bedrooms with approved material -SEAL GAPS
Suspended Slab Inspection Passed 02/13/2025
Misc
Informational
02/13/2025
Approved by Bob Rowe of VAN DEURZEN AND ASSOCIATES on 8/6/24
All Rough Inspection - Residential Passed 2/18/2025 2/18/2025 02/18/2025
Misc
Resolved
02/18/2025
Exterior PFH ONLY approved to cover
Misc
Resolved
02/18/2025
- Fire block top of fireplace in hearth room -SEAL GAPS - Strap all over board top plates on bearing wall at laundry and powder room-BOTH SIDES AND MISSING AT RADON - Purlin struts to be 4’ OC throughout-OVER 4’ AT MASTER BED AND HALLWAY OFF OF GARAGE - Provide straps on load bearing wall with over board for DWV in prep kitchen-STRUCTURAL STRAPS TO EXTEND 6” EACH WAY OF HOLES AND HAVE MIN (4) 10D NAILS EACH SIDE - Strap top plate in master bathroom vanity wall were over bored on bearing wall-NOT DONE (2) LOCATIONS - Unable to inspect framing of porch or deck cover ( covered) - No suspended slab inspection on file-ADDRESS BEFORE ANY RE INSPECTION - Fire block top of dead space at bedroom 2 shower-SEAL GAPS - Minimum of 3 studs on all exterior corners in bedroom 2-PROTECT NM IN CLOSET - Fire block chase in bedroom 4 closet at top plate-SEAL GAPS - Fire block top of chase at shower between bedroom 3/4-SEAL GAPS - Replace vertical fire blocking in basement bedrooms with approved material -SEAL GAPS
Documents & Images
Date Uploaded File Type Document Name
03/28/2024 Sealed Plot Plan - OK Troy - Fulson
03/28/2024 RWR165A Fulson - Sealed Plans (February 19, 2024)
03/28/2024 I-Joist Engineering - SEALED - RWR165A Fulson I-Joist Layout
03/28/2024 Fulson permit app_
04/04/2024 Permit Codes Residential Plan Review
04/05/2024 I-Joist Engineering - SEALED - RWR165A Fulson I-Joist Layout
04/08/2024 Approved Plans APPROVED JOIST DRAWING
04/10/2024 Plot Plan APPROVED PLOT PLAN
04/12/2024 Approved Plans APPROVED PLANS
04/15/2024 Receipt Receipt for transaction: 2024-002392
04/17/2024 Permit Codes Residential Plan Review
04/18/2024 Letter DS Building Permit
06/12/2024 Engineer Report/Study ENGINEER SOILS REPORT
06/12/2024 Approved Plans PIER LAYOUT
06/14/2024 Letter INSPECTION SUMMARY
06/14/2024 Letter INSPECTION SUMMARY
06/14/2024 Letter Stop Work Order
06/17/2024 Approved Plans APPROVED PIER PLAN
06/18/2024 inspection letter fulson job
06/19/2024 Photograph 2120obrienufer
06/19/2024 3rd Party Permit/Approval THIRD PARTY FOOTING INSPECTION
06/19/2024 Letter INSPECTION SUMMARY
06/19/2024 Letter INSPECTION SUMMARY
06/19/2024 Letter INSPECTION SUMMARY
06/19/2024 Letter INSPECTION SUMMARY
06/21/2024 Letter INSPECTION SUMMARY
06/21/2024 Letter INSPECTION SUMMARY
06/24/2024 Letter INSPECTION SUMMARY
06/25/2024 Letter INSPECTION SUMMARY
11/08/2024 Letter INSPECTION SUMMARY
12/11/2024 Letter INSPECTION SUMMARY
12/11/2024 Letter INSPECTION SUMMARY
12/18/2024 Letter INSPECTION SUMMARY
01/24/2025 Letter INSPECTION SUMMARY
01/24/2025 Letter INSPECTION SUMMARY
01/29/2025 Letter INSPECTION SUMMARY
01/29/2025 Letter INSPECTION SUMMARY
01/29/2025 Letter INSPECTION SUMMARY
02/10/2025 Letter INSPECTION SUMMARY
02/10/2025 Letter INSPECTION SUMMARY
02/11/2025 2120 NW O'Brien Rd_SUS GAR SLAB INSP_2024-08-06
02/13/2025 Letter INSPECTION SUMMARY
02/18/2025 Letter INSPECTION SUMMARY
02/18/2025 Letter INSPECTION SUMMARY
07/08/2025 Letter Codes 140 Day Letter
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home