Summary
PRRES20240647
Building Permit - Residential
Certificate of Occupancy
NEW 3 OR 4 FAMILY
NEW FOUR PLEX - ROOF TRUSSES - FINISHED AND UNFINISHED BASEMENT - UNCOVERED DECKS STOP WORK ORDER generated on 04/25/2024 12:00 AM by username 'Dustin Agcopra'. STOP WORK ORDER removed on 04/25/2024 12:00 AM by username 'Dustin Agcopra'. STOP WORK ORDER generated on 11/06/2024 12:00 AM by username 'Dustin Agcopra'. STOP WORK ORDER removed on 02/11/2025 12:00 AM by username 'Kyle Beard'.
02/15/2024
03/04/2024
08/25/2024
04/07/2025
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
BRUCER@SUMMITHOMESKC.COM  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
CARUTHERS ELECTRICAL LLC, Address:30905 E TRUMAN RD, Phone:(816) 508-9050  
BILL'S PLUMBING SERVICE LLC, Address:308 E PARK STREET, Phone:(913) 829-8213  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Rejected 02/29/2024 02/27/2024
Brandon Kalwei
04 Two (2) copies of construction drawings
Corrective Action Required
02/27/2024

Two (2) copies of construction drawings. (Plans to be signed and sealed by an architect or engineer registered in the State of Missouri.) BUILDING PLANS SHOW THE STREET OF MARYVILLE PL. PLOT PLAN SHOWS IT IS OFF OF CLAYTON PL. PLEASE CORRECT WHATEVER IS WRONG.
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee for New 3 or 4 Family $4,501.26 $4,501.26 Paid 03/04/2024
Sanitary Sewer Development Fee $8,636.00 $8,636.00 Paid 03/04/2024
Right of Way Permit Fee $85.00 $85.00 Paid 03/04/2024
Residential Excise Tax Fee $2,480.64 $2,480.64 Paid 03/04/2024
Water Tap Fee $15,040.00 $15,040.00 Paid 03/04/2024
Water Meter Fee $2,721.84 $2,721.84 Paid 03/04/2024
3rd and Subsequent Inspection Fee (Per Hour) $50.00 $50.00 Paid 07/30/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 10/14/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 10/14/2024
3rd and Subsequent Inspection Fee (Per Hour) $50.00 $50.00 Paid 10/14/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 10/14/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 10/15/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 11/05/2024
Outstanding Fees Amount Paid Owing Date Paid


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Passed 4/25/2024 04/25/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
04/25/2024
4-25-24 Dustin A, EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Footing Inspection - Residential Passed 4/29/2024 04/29/2024
Miscellaneous Correction
Informational
04/29/2024
-Footing passed by a third party -Piers were not mentioned in footing report
Erosion Control Inspection Residential Failed 4/29/2024 04/29/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
04/25/2024
4-25-24 Dustin A, EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
04/29/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. Gravel needs to be installed between the street and foundation
Sewer Service Inspection - R Partial 4/29/2024 4/29/2024 04/29/2024
Miscellaneous Correction
Informational
04/29/2024
Sewer at 3712 and 3716 both passed Other two units will be scheduled for inspection at a later date. This is a partial pass only
Sewer Service Inspection - R Passed 4/30/2024 4/30/2024 04/30/2024
Miscellaneous Correction
Resolved
04/30/2024
Sewer at 3712 and 3716 both passed Other two units will be scheduled for inspection at a later date. This is a partial pass only
Water Service Inspection - R Passed 4/30/2024 04/30/2024
Erosion Control Inspection Residential Failed 5/20/2024 05/20/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
05/20/2024
4-25-24 Dustin A, EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
05/20/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. Gravel needs to be installed between the street and foundation
Miscellaneous Correction
Corrective Action Required
05/20/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. Silt fence around the property has been damaged and or is missing. Repair, replace or install silt fence before scheduling any more inspections
Underslab Electrical Inspection - Residential Failed 5/20/2024 5/20/2024 05/20/2024
Miscellaneous Correction
Corrective Action Required
05/20/2024
Erosion control must pass before any inspections will be conducted. Underslab electrical was not inspected
Underslab Plumbing Inspection - Residential Failed 5/20/2024 5/20/2024 05/20/2024
Miscellaneous Correction
Corrective Action Required
05/20/2024
Erosion control must pass before any inspections will be conducted. Underslab plumbing was not inspected
Erosion Control Inspection Residential Partial 5/22/2024 05/22/2024
Miscellaneous Correction
Resolved
05/22/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. Silt fence around the property has been damaged and or is missing. Repair, replace or install silt fence before scheduling any more inspections
Miscellaneous Correction
Informational
05/22/2024
Erosion control measures are in place and must be maintained until CofO
Underslab Electrical Inspection - Residential Passed 5/22/2024 5/22/2024 05/22/2024
Miscellaneous Correction
Resolved
05/22/2024
Erosion control must pass before any inspections will be conducted. Underslab electrical was not inspected
Underslab Plumbing Inspection - Residential Passed 5/22/2024 5/22/2024 05/22/2024
Miscellaneous Correction
Resolved
05/22/2024
Erosion control must pass before any inspections will be conducted. Underslab plumbing was not inspected
Erosion Control Inspection Residential Failed 6/11/2024 06/11/2024
Miscellaneous Correction
Resolved
06/11/2024
Erosion control measures are in place and must be maintained until CofO
Miscellaneous Correction
Corrective Action Required
06/11/2024
Some silt fence and or straw waddle is damaged or missing and needs to be repaired or replaced. Full erosion control measures must be in place and maintained until CofO
All Rough Inspection - Residential Failed 6/11/2024 6/11/2024 06/11/2024
Miscellaneous Correction
Corrective Action Required
06/11/2024
- Interior garage portal tie down straps passed - Exterior sheeting of garage portal is not continuous to the upper top plate. Both top plates need to be nailed for a proper portal inspection for code - Interior anchor bolts were not ready for inspection Inspection was scheduled for a portal only.
All Rough Inspection - Residential Failed 6/17/2024 6/17/2024 06/17/2024
Miscellaneous Correction
Resolved
06/17/2024
- Interior garage portal tie down straps passed - Exterior sheeting of garage portal is not continuous to the upper top plate. Both top plates need to be nailed for a proper portal inspection for code - Interior anchor bolts were not ready for inspection Inspection was scheduled for a portal only.
Miscellaneous Correction
Corrective Action Required
06/17/2024
Interior straps on all units passed 3718 South exterior sheeting needs to be nailed to both top plates 3716 Anchor bolts are not installed 3712 Passed 3710 Exterior sheeting needs to be nailed to both top plates Tightened down North side anchor bolt
Erosion Control Inspection Residential Failed 6/17/2024 06/17/2024
Miscellaneous Correction
Resolved
06/17/2024
Some silt fence and or straw waddle is damaged or missing and needs to be repaired or replaced. Full erosion control measures must be in place and maintained until CofO
DCM3 ESC REQUIRED 2 DAY
Resolved
06/17/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
06/17/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Some silt fence and or straw waddle is damaged or missing and needs to be repaired or replaced. Full erosion control measures must be in place and maintained until CofO No inspections until full erosion control measures are in place
All Rough Inspection - Residential Failed 6/21/2024 6/21/2024 06/21/2024
Miscellaneous Correction
Resolved
06/21/2024
Interior straps on all units passed 3718 South exterior sheeting needs to be nailed to both top plates 3716 Anchor bolts are not installed 3712 Passed 3710 Exterior sheeting needs to be nailed to both top plates Tightened down North side anchor bolt
Miscellaneous Correction
Corrective Action Required
06/21/2024
- Exterior sheeting passed on all units and is okay to cover - Interior straps and anchor bolts will be inspected at all rough This is a partial pass for the exterior garage sheeting only
Erosion Control Inspection Residential Partial 6/21/2024 06/21/2024
DCM3 ESC REQUIRED 2 DAY
Resolved
06/21/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Some silt fence and or straw waddle is damaged or missing and needs to be repaired or replaced. Full erosion control measures must be in place and maintained until CofO No inspections until full erosion control measures are in place
Miscellaneous Correction
Informational
06/21/2024
Full erosion control is in place and must be maintained until CofO
All Rough Inspection - Residential Not Ready 7/30/2024 7/30/2024 07/30/2024
Miscellaneous Correction
Corrective Action Required
06/21/2024
- Exterior sheeting passed on all units and is okay to cover - Interior straps and anchor bolts will be inspected at all rough This is a partial pass for the exterior garage sheeting only
Misc
Corrective Action Required
07/30/2024
NOT READY, INSPECTION DENIDE NO CITY STAMPED PLANS OR TRUSS PACKAGE ON SIGHT
All Rough Inspection - Residential Not Ready 7/31/2024 7/31/2024 07/31/2024
Miscellaneous Correction
Corrective Action Required
07/30/2024
- Exterior sheeting passed on all units and is okay to cover - Interior straps and anchor bolts will be inspected at all rough This is a partial pass for the exterior garage sheeting only
Misc
Corrective Action Required
07/30/2024
NOT READY, INSPECTION DENIDE NO CITY STAMPED PLANS OR TRUSS PACKAGE ON SIGHT
Misc
Corrective Action Required
07/31/2024
NOT READY CITY STAMPED PLANS REQUIRED FOR INSPECTION
Electrical Service Inspection Passed 8/1/2024 08/01/2024
Gas Service Inspection - Residential Passed 8/1/2024 08/01/2024
Erosion Control Inspection Residential Failed 8/1/2024 08/01/2024
Miscellaneous Correction
Resolved
08/01/2024
Full erosion control is in place and must be maintained until CofO
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
08/01/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. - REPAIR SILT FENCE - REMOVE TRASH FROM LOT
All Rough Inspection - Residential Failed 8/1/2024 8/1/2024 08/01/2024
Miscellaneous Correction
Corrective Action Required
07/31/2024
- Exterior sheeting passed on all units and is okay to cover This is a partial pass for the exterior garage sheeting only
Misc
Resolved
08/01/2024
NOT READY, INSPECTION DENIDE NO CITY STAMPED PLANS OR TRUSS PACKAGE ON SIGHT
Misc
Resolved
08/01/2024
NOT READY CITY STAMPED PLANS REQUIRED FOR INSPECTION
Misc
Corrective Action Required
08/01/2024
3718 - tighten anchor bolts at garage portal frame - Tighten anchor bolts through out - Address sill plate north side garage with 2” unsupported and broken out anchor bolts - Lower electrical boxes in ceiling of garage due to fur out - LIBs missing in great room - Mount vent fan basement bathroom - Provide anchor bolt at basement sill plate break bedroom 2 - Flashing and trim all windows on back of building - Label service disconnect 3716 - missing 2” washers and nuts at garage portal frame - Address bearing of sill plate North side of garage, 3/4” not supported - Lower electrical boxes in garage below furnace out - Mount basement bathroom vent fan - Tighten anchor bolts through out - Box for smoke detector covered by soffit at basement bedroom 3712 - Move all electrical boxes down in garage due to fur down - Tighten anchor bolts through out - Mount basement bathroom vent fan 3710 - Tighten anchor bolts at garage portal frame - Lower electrical boxes in garage ceiling due to fur down - Address support for sill plate south side of garage over 1” not supported - Provide hold downs for girter truss in bedroom 1 - Complete basement bath vent fan - Land electrical in basement bathroom
All Rough Inspection - Residential Failed 8/12/2024 8/12/2024 08/12/2024
Miscellaneous Correction
Corrective Action Required
08/01/2024
- Exterior sheeting passed on all units and is okay to cover This is a partial pass for the exterior garage sheeting only
Misc
Corrective Action Required
08/01/2024
3718 - tighten anchor bolts at garage portal frame - Tighten anchor bolts through out - Address sill plate north side garage with 2” unsupported and broken out anchor bolts - Lower electrical boxes in ceiling of garage due to fur out - LIBs missing in great room - Mount vent fan basement bathroom - Provide anchor bolt at basement sill plate break bedroom 2 - Flashing and trim all windows on back of building - Label service disconnect 3716 - missing 2” washers and nuts at garage portal frame - Address bearing of sill plate North side of garage, 3/4” not supported - Lower electrical boxes in garage below furnace out - Mount basement bathroom vent fan - Tighten anchor bolts through out - Box for smoke detector covered by soffit at basement bedroom 3712 - Move all electrical boxes down in garage due to fur down - Tighten anchor bolts through out - Mount basement bathroom vent fan 3710 - Tighten anchor bolts at garage portal frame - Lower electrical boxes in garage ceiling due to fur down - Address support for sill plate south side of garage over 1” not supported - Provide hold downs for girter truss in bedroom 1 - Complete basement bath vent fan - Land electrical in basement bathroom
All Rough Inspection - Residential Passed 8/13/2024 8/13/2024 08/13/2024
Miscellaneous Correction
Corrective Action Required
08/12/2024
- Exterior sheeting passed on all units and is okay to cover This is a partial pass for the exterior garage sheeting only
Misc
Corrective Action Required
08/12/2024
3718 - tighten anchor bolts at garage portal frame - Tighten anchor bolts through out - Address sill plate north side garage with 2” unsupported and broken out anchor bolts - Lower electrical boxes in ceiling of garage due to fur out - LIBs missing in great room - Mount vent fan basement bathroom - Provide anchor bolt at basement sill plate break bedroom 2 - Flashing and trim all windows on back of building - Label service disconnect 3716 - missing 2” washers and nuts at garage portal frame - Address bearing of sill plate North side of garage, 3/4” not supported - Lower electrical boxes in garage below furnace out - Mount basement bathroom vent fan - Tighten anchor bolts through out - Box for smoke detector covered by soffit at basement bedroom 3712 - Move all electrical boxes down in garage due to fur down - Tighten anchor bolts through out - Mount basement bathroom vent fan 3710 - Tighten anchor bolts at garage portal frame - Lower electrical boxes in garage ceiling due to fur down - Address support for sill plate south side of garage over 1” not supported - Provide hold downs for girter truss in bedroom 1 - Complete basement bath vent fan - Land electrical in basement bathroom
Miscellaneous Correction
Corrective Action Required
08/12/2024
3716 Bow for smoke detector is covered by sofit at basement bedroom
Rated Assembly Inspection Failed 8/19/2024 8/19/2024 08/19/2024
Miscellaneous Correction
Corrective Action Required
08/19/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. - REPAIR SILT FENCE - REMOVE TRASH FROM LOT Dated 08/01/2024. K.Beard
Erosion Control Inspection Residential Failed 8/19/2024 08/19/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
08/01/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. - REPAIR SILT FENCE - REMOVE TRASH FROM LOT
Rated Assembly Inspection Partial 8/20/2024 8/20/2024 08/20/2024
Miscellaneous Correction
Resolved
08/20/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. - REPAIR SILT FENCE - REMOVE TRASH FROM LOT Dated 08/01/2024. K.Beard
Miscellaneous Correction
Informational
08/20/2024
Screw pattern on units 3710,3712 and 3716 all passed and are okay to cover This is a partial pass only. Unit 3718 will be scheduled for a later date
Rated Assembly Inspection Passed 8/21/2024 8/21/2024 08/21/2024
Miscellaneous Correction
Resolved
08/21/2024
Screw pattern on units 3710,3712 and 3716 all passed and are okay to cover This is a partial pass only. Unit 3718 will be scheduled for a later date
Erosion Control Inspection Residential Partial 8/21/2024 08/21/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
08/21/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. - REPAIR SILT FENCE - REMOVE TRASH FROM LOT
Miscellaneous Correction
Informational
08/21/2024
Full erosion control measures are in place and must be maintained until CofO
Driveway Inspection Partial 8/27/2024 08/27/2024
Misc
Informational
08/27/2024
8-27-24 PS Driveway approach pre pour, forms in place, aggregate compacted, approved to pour
Sidewalk Inspection Partial 8/27/2024 08/27/2024
Misc
Informational
08/27/2024
8-27-24 PS Sidewalk pre pour, forms in place and aggregate compacted, approved to pour
Sidewalk Inspection Passed 9/9/2024 9/9/2024 09/09/2024
Misc
Informational
08/27/2024
8-27-24 PS Sidewalk pre pour, forms in place and aggregate compacted, approved to pour 9-9-24 PS Sidewalk meets ADA an LS specs
Driveway Inspection Passed 9/9/2024 9/9/2024 09/09/2024
Misc
Informational
08/27/2024
8-27-24 PS Driveway approach pre pour, forms in place, aggregate compacted, approved to pour 9-9-24 PS Driveway approaches meet ADA and LS specs
Piers/Caissons Inspection - Residential Failed 9/11/2024 9/11/2024 09/11/2024
Miscellaneous Correction
Corrective Action Required
09/11/2024
No address numbers on units for proper identification
Piers/Caissons Inspection - Residential Passed 9/18/2024 9/18/2024 09/18/2024
Miscellaneous Correction
Resolved
09/18/2024
No address numbers on units for proper identification
Occupancy Inspection - Codes Residential Not Ready 10/10/2024 10/10/2024 10/10/2024
Miscellaneous Correction
Corrective Action Required
10/10/2024
3710 - 3718 SW Clayton. Occupancy 3710 Fire block gaps in garage at rated assembly wall Handrail from the entry going to the main living area does not go to the stair nosing Stair riser from entry to main living area has a greater than the code allowed 3/8 of and inch difference Anti water device is not installed under the kitchen sink 3712 Check stair riser height for code compliance Garage stairs to house needs guard rails installed 3716 Attic access hatch is not installed Master bedroom and second bedroom upstairs smoke detector is not working properly Fire block hole in garage sheet rock south wall Garage stairs to house needs guard rails installed 3718 Locked at time of inspection Not ready. No access provided This is not a complete list
Erosion Control Inspection Residential Partial 10/10/2024 10/10/2024
Miscellaneous Correction
Informational
08/21/2024
Full erosion control measures are in place and must be maintained until CofO
Erosion Control Inspection Residential Partial 10/14/2024 10/14/2024
Miscellaneous Correction
Informational
10/10/2024
Full erosion control measures are in place and must be maintained until CofO
Occupancy Inspection - Codes Residential Failed 10/14/2024 10/14/2024 10/14/2024
Miscellaneous Correction
Corrective Action Required
10/10/2024
3710 - 3718 SW Clayton. Occupancy 3710 Fire block gaps in garage at rated assembly wall Handrail from the entry going to the main living area does not go to the stair nosing Stair riser from entry to main living area has a greater than the code allowed 3/8 of and inch difference Anti water device is not installed under the kitchen sink 3712 Check stair riser height for code compliance Garage stairs to house needs guard rails installed 3716 Attic access hatch is not installed Master bedroom and second bedroom upstairs smoke detector is not working properly Fire block hole in garage sheet rock south wall Garage stairs to house needs guard rails installed 3718 Locked at time of inspection Not ready. No access provided This is not a complete list
Miscellaneous Correction
Corrective Action Required
10/14/2024
3710 - 3718 SW Clayton. Occupancy (2) 3710 •Stair riser from entry to main living area has a greater than the code allowed 3/8 of and inch difference •Splash pads are not installed •A/C disconnect needs to be attached to the siding within 12 inches of disconnect 3712 •Check stair riser height for code compliance at main living area to upstairs •Splash pads not installed 3716 •Attic access hatch is not installed •Master bedroom and second bedroom upstairs smoke detector is not working properly •Splash pads not installed 3718 •Check stair fisher for code compliance at entry going to main living area •Tighten all through bolts on deck to beam connection •Attic access hatch is not installed •Sump pump extension is not installed •A/C disconnect needs to be attached to the siding with 12 inches of disconnect •Splash pads not installed Sod is not installed on all units Pay $275 in fees associated with this permit
Occupancy Inspection - Codes Residential Ready for Temp CO 10/15/2024 10/15/2024 10/15/2024
Miscellaneous Correction
Resolved
10/15/2024
3710 - 3718 SW Clayton. Occupancy 3710 Fire block gaps in garage at rated assembly wall Handrail from the entry going to the main living area does not go to the stair nosing Stair riser from entry to main living area has a greater than the code allowed 3/8 of and inch difference Anti water device is not installed under the kitchen sink 3712 Check stair riser height for code compliance Garage stairs to house needs guard rails installed 3716 Attic access hatch is not installed Master bedroom and second bedroom upstairs smoke detector is not working properly Fire block hole in garage sheet rock south wall Garage stairs to house needs guard rails installed 3718 Locked at time of inspection Not ready. No access provided This is not a complete list
Miscellaneous Correction
Resolved
10/15/2024
3710 - 3718 SW Clayton. Occupancy (2) 3710 •Stair riser from entry to main living area has a greater than the code allowed 3/8 of and inch difference •Splash pads are not installed •A/C disconnect needs to be attached to the siding within 12 inches of disconnect 3712 •Check stair riser height for code compliance at main living area to upstairs •Splash pads not installed 3716 •Attic access hatch is not installed •Master bedroom and second bedroom upstairs smoke detector is not working properly •Splash pads not installed 3718 •Check stair fisher for code compliance at entry going to main living area •Tighten all through bolts on deck to beam connection •Attic access hatch is not installed •Sump pump extension is not installed •A/C disconnect needs to be attached to the siding with 12 inches of disconnect •Splash pads not installed Sod is not installed on all units Pay $275 in fees associated with this permit
Miscellaneous Correction
Corrective Action Required
10/15/2024
3710 - 3718 SW Clayton. Occupancy (3) 3710 •Splash pads are not installed •A/C disconnect needs to be attached to the siding within 12 inches of disconnect 3712 •Splash pads not installed 3716 •Splash pads not installed 3718 •Tighten all through bolts on deck to beam •Sump pump extension is not installed •A/C disconnect needs to be attached to the siding with 12 inches of disconnect •Splash pads not installed Sod is not installed on all units Pay $275 in fees associated with this permit All units passed for TCO only
Erosion Control Inspection Residential Failed 11/4/2024 11/4/2024 11/04/2024
Miscellaneous Correction
Informational
10/14/2024
Full erosion control measures are in place and must be maintained until CofO
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
11/04/2024
11-4-24 Dustin A, all sws have silt due to improper erosion control..EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Occupancy Inspection - Codes Residential Ready for Temp CO 11/5/2024 11/05/2024
Miscellaneous Correction
Resolved
11/05/2024
3710 - 3718 SW Clayton. TCO extension 3710 •Splash pads are not installed •A/C disconnect needs to be attached to the siding within 12 inches of disconnect 3712 •Splash pads not installed 3716 •Splash pads not installed 3718 •Tighten all through bolts on deck to beam •Sump pump extension is not installed •A/C disconnect needs to be attached to the siding with 12 inches of disconnect •Splash pads not installed Sod is not installed on all units All units passed for TCO only Builder sent in a TCO extension request, this is the first extension request
Miscellaneous Correction
Corrective Action Required
11/05/2024
3710 - 3718 SW Clayton. TCO extension 3710 •Splash pads are not installed •A/C disconnect needs to be attached to the siding within 12 inches of disconnect 3712 •Splash pads not installed 3716 •Splash pads not installed 3718 •Tighten all through bolts on deck to beam •Sump pump extension is not installed •A/C disconnect needs to be attached to the siding with 12 inches of disconnect •Splash pads not installed Sod is not installed on all units All units passed for TCO only Builder sent in a TCO extension request, this is the first extension request
Erosion Control Inspection Residential Failed - Stop Work 11/6/2024 11/6/2024 11/06/2024
Miscellaneous Correction
Informational
11/04/2024
Full erosion control measures are in place and must be maintained until CofO
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
11/04/2024
11-4-24 Dustin A, all sws have silt due to improper erosion control..EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. 11-6-24 Dustin A, nothing has changed
Erosion Control Inspection Residential Passed 2/12/2025 02/12/2025
Miscellaneous Correction
Resolved
02/12/2025
Full erosion control measures are in place and must be maintained until CofO
DCM3 ESC REQUIRED 2 DAY
Resolved
02/12/2025
11-4-24 Dustin A, all sws have silt due to improper erosion control..EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. 11-6-24 Dustin A, nothing has changed
Occupancy Inspection - Codes Residential Failed 2/12/2025 2/13/2025 02/13/2025
Miscellaneous Correction
Resolved
02/13/2025
3710 - 3718 SW Clayton. TCO extension 3710 •Splash pads are not installed •A/C disconnect needs to be attached to the siding within 12 inches of disconnect 3712 •Splash pads not installed 3716 •Splash pads not installed 3718 •Tighten all through bolts on deck to beam •Sump pump extension is not installed •A/C disconnect needs to be attached to the siding with 12 inches of disconnect •Splash pads not installed Sod is not installed on all units All units passed for TCO only Builder sent in a TCO extension request, this is the first extension request
Miscellaneous Correction
Corrective Action Required
02/13/2025
Pay $100 in fees associated with this permit and then resubmit for a occupancy inspection
Plot Plan Inspection Passed 2/13/2025 02/13/2025
Occupancy Inspection - Codes Residential Full C of O 04/07/2025
Miscellaneous Correction
Resolved
04/07/2025
Pay $100 in fees associated with this permit and then resubmit for a occupancy inspection
Documents & Images
Date Uploaded File Type Document Name
02/22/2024 Permit Codes Residential Plan Review
02/27/2024 Permit Codes Residential Plan Review
03/04/2024 Application Form PERMIT APP
03/04/2024 Approved Plans APPROVED PLANS
03/04/2024 Approved Plans APPROVED TRUSS LAYOUT
03/04/2024 Approved Plans APPROVED TRUSS PACKAGE
03/04/2024 Permit Codes Residential Plan Review
03/04/2024 Plot Plan approved plot plan
03/04/2024 Permit DS Building Permit
03/04/2024 Receipt Receipt for transaction:2024-001320
04/25/2024 Letter Stop Work Order
04/25/2024 Letter Stop Work Order
04/25/2024 Letter INSPECTION SUMMARY
04/26/2024 3RD Party Insp Report 3rd Party Footing Inspection Report 4-17-24
04/29/2024 Letter INSPECTION SUMMARY
04/29/2024 Letter INSPECTION SUMMARY
04/29/2024 Letter INSPECTION SUMMARY
04/29/2024 Letter INSPECTION SUMMARY
04/30/2024 Letter INSPECTION SUMMARY
04/30/2024 Letter INSPECTION SUMMARY
05/20/2024 Letter INSPECTION SUMMARY
05/20/2024 Letter INSPECTION SUMMARY
05/20/2024 Letter INSPECTION SUMMARY
05/22/2024 Letter INSPECTION SUMMARY
05/22/2024 Letter INSPECTION SUMMARY
05/22/2024 Letter INSPECTION SUMMARY
06/11/2024 Letter INSPECTION SUMMARY
06/11/2024 Letter INSPECTION SUMMARY
06/12/2024 OS #13 - TCO Extension Form 6_12_24
06/17/2024 Letter INSPECTION SUMMARY
06/17/2024 Letter INSPECTION SUMMARY
06/21/2024 Letter INSPECTION SUMMARY
06/21/2024 Letter INSPECTION SUMMARY
07/22/2024 SUMMIT - FJ UNDER TUB - 240719
07/30/2024 Receipt Receipt for transaction:2024-006372
07/31/2024 Letter INSPECTION SUMMARY
07/31/2024 Letter INSPECTION SUMMARY
08/01/2024 Letter INSPECTION SUMMARY
08/01/2024 Letter INSPECTION SUMMARY
08/01/2024 Letter INSPECTION SUMMARY
08/01/2024 Letter INSPECTION SUMMARY
08/07/2024 3RD Party Insp Report ENGINEER LETTER
08/13/2024 Letter INSPECTION SUMMARY
08/19/2024 Letter INSPECTION SUMMARY
08/19/2024 Letter INSPECTION SUMMARY
08/19/2024 Letter INSPECTION SUMMARY
08/20/2024 Letter INSPECTION SUMMARY
08/21/2024 Letter INSPECTION SUMMARY
08/21/2024 Letter INSPECTION SUMMARY
08/27/2024 Letter INSPECTION SUMMARY
08/27/2024 Letter INSPECTION SUMMARY
09/09/2024 Letter INSPECTION SUMMARY
09/09/2024 Letter INSPECTION SUMMARY
09/11/2024 Letter INSPECTION SUMMARY
09/18/2024 Letter INSPECTION SUMMARY
10/10/2024 Letter INSPECTION SUMMARY
10/10/2024 Letter INSPECTION SUMMARY
10/14/2024 Letter INSPECTION SUMMARY
10/14/2024 Letter INSPECTION SUMMARY
10/14/2024 Receipt Receipt for transaction:2024-008310
10/15/2024 Letter INSPECTION SUMMARY
10/15/2024 Certificate/License Codes Temporary Certificate of Occupancy
10/15/2024 Receipt Receipt for transaction:2024-008340
10/29/2024 Osage Duplexes Rear Wall Email
11/04/2024 OS #42 - TCO Extension 11_4_24
11/04/2024 Letter INSPECTION SUMMARY
11/04/2024 Letter INSPECTION SUMMARY
11/05/2024 Letter INSPECTION SUMMARY
11/05/2024 Certificate/License Codes Temporary Certificate of Occupancy
11/05/2024 Receipt Receipt for transaction:2024-008769
11/06/2024 Letter Stop Work Order
02/12/2025 Letter INSPECTION SUMMARY
02/12/2025 Letter INSPECTION SUMMARY
02/13/2025 Letter INSPECTION SUMMARY
02/13/2025 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home