Summary
PRRES20236080
Building Permit - Residential
Notice of Violation
MCFARLAND CUSTOM BUILDERS INC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED DECK STOP WORK ORDER generated on 02/06/2024 12:00 AM by username 'Mitchell Schwarz'. STOP WORK ORDER removed on 02/20/2024 12:00 AM by username 'Mitchell Schwarz'. STOP WORK ORDER generated on 06/25/2024 12:00 AM by username 'Mitchell Schwarz'. STOP WORK ORDER removed on 07/12/2024 12:00 AM by username 'Mitchell Schwarz'.
11/16/2023
01/17/2024
07/10/2024
Locations
Contacts
McFarland Dalton Builders LLC, Address:9601 Ne Barry RD Suite 130, Phone:(816) 215-1660  
MCFARLAND CUSTOM BUILDERS INC, Address:9601 NE BARRY RD STE 130  
Cade Dalton, Address:9601 NE Barry RD, Phone:(816) 550-1148  
CARUTHERS ELECTRICAL LLC, Address:30905 E TRUMAN RD, Phone:(816) 508-9050  
A BRIGHT PLUMBING LLC, Address:18107 E 18TH TER N, Phone:(816) 215-0730  
5 STAR MECHANICAL, LLC, Address:PO BOX 793, Phone:(816) 679-0375  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 01/17/2024
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 01/17/2024
7232302-Residential License Tax Fee $1,022.72 $1,022.72 Paid 01/17/2024
8331401-Water Tap Fee $3,760.00 $3,760.00 Paid 01/17/2024
8350015-Water Meter Fee $680.46 $680.46 Paid 01/17/2024
9110078-Valuation Fee New Single Family $2,233.76 $2,233.76 Paid 01/17/2024
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 12/17/2024
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 12/17/2024
9110080-3rd and Subsequent Inspection Fee (Per Hour) $75.00 $75.00 Paid 12/17/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 12/17/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 03/06/2025
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 03/10/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Pending
Misc
Informational
12/17/2024
Erosion control in compliance
Plot Plan Inspection Pending
Misc
Corrective Action Required
02/14/2025
Snow coverage to significant to check grade. Will check at later date.
Occupancy Inspection - Codes Residential Pending
Misc
Corrective Action Required
04/09/2025
TCO expired. permit in notice of violation. Mitchell Schwarz 04/09/2025 7:17 AM TCO extension letter uploaded and granted for another 30 days from original TCO -pay all fees -final grade and sod -uncover covered water meter -splash blocks and sump pump discharge to extend 36” from foundation -complete stairs at rear. (Stairs and handrail must meet the requirements of code see sections (R311.7.6, R311.7.8.4, R312.1)
Footing Inspection - Residential Failed - Stop Work 2/6/2024 2/6/2024 02/06/2024
Misc
Corrective Action Required
02/06/2024
Erosion control not in compliance inspection denied.
Erosion Control Inspection Residential Failed - Stop Work 2/6/2024 02/06/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
02/06/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. Silt fence to border lot and spoils piles Lot access to be in compliance Clean street and install storm gutter protection
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
02/06/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
02/06/2024
STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
Erosion Control Inspection Residential Failed 2/8/2024 2/8/2024 02/08/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
02/06/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND Lot access to be in compliance Provide address at lots
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
02/06/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
02/06/2024
STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
Erosion Control Inspection Residential Partial 2/20/2024 02/20/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
02/20/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND Lot access to be in compliance Provide address at lots
DCM3 ESC REQUIRED 2 DAY
Resolved
02/20/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM6 ESC INSP DENIED STREET CLEAN UP
Resolved
02/20/2024
STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
Misc
Informational
02/20/2024
Erosion control back in compliance at time of inspection
Footing Inspection - Residential Passed 2/20/2024 02/20/2024
Misc
Resolved
02/20/2024
Erosion control not in compliance inspection denied.
Underslab Plumbing Inspection - Residential Failed 3/7/2024 03/07/2024
Misc
Corrective Action Required
03/07/2024
Inspection denied no address posted
Underslab Plumbing Inspection - Residential Passed 3/11/2024 3/11/2024 03/11/2024
Misc
Resolved
03/11/2024
Inspection denied no address posted
Sewer Service Inspection - R Passed 3/22/2024 3/22/2024 03/22/2024
Water Service Inspection - R Passed 3/22/2024 3/22/2024 03/22/2024
All Rough Inspection - Residential Failed 6/19/2024 6/19/2024 06/19/2024
Miscellaneous Correction
Corrective Action Required
06/19/2024
Garage portal framing inspection only (CS-PF) - Exterior sheeting does not fully extend to the upper top plate - Exterior sheeting needs to be fastened to the upper top plate - Exterior hold down straps are missing fasteners in spots - Interior jack stud straps are not located in the correct location (see plans sheet S505 #2 - Interior jack stud straps are not fastened down within the upper top plate - 5/8 inch interior garage anchor bolt is not located within the middle 1/3 of the sole plate See sheet S505 #2 in plans for proper garage portal CS-PF installation
Water Service Inspection - R Failed - Stop Work 6/25/2024 06/25/2024
Misc
Corrective Action Required
06/25/2024
Address meter well full of concrete. No further inspections until addressed
Water Service Inspection - R Failed 7/3/2024 07/03/2024
Misc
Resolved
07/03/2024
Address meter well full of concrete. No further inspections until addressed
Misc
Corrective Action Required
07/03/2024
-Meter is broken needs to be replaced
Water Service Inspection - R Not Ready 7/10/2024 07/10/2024
Misc
Corrective Action Required
07/03/2024
-Meter is broken needs to be replaced 07/10/24- meter still broken
Erosion Control Inspection Residential Failed - Stop Work 7/10/2024 07/10/2024
Misc
Corrective Action Required
07/10/2024
Maintain gravel entrance and over grown vegetation
Erosion Control Inspection Residential Partial 7/12/2024 07/12/2024
Misc
Resolved
07/12/2024
Maintain gravel entrance and over grown vegetation
Misc
Informational
07/12/2024
Erosion control in compliance
All Rough Inspection - Residential Not Ready 7/23/2024 7/23/2024 07/23/2024
Misc
Corrective Action Required
07/23/2024
-Inspection denied no city stamped plans on site -Maintain overgrown, vegetation in clear debris from garage before scheduling reinspection
Electrical Service Inspection Failed 7/23/2024 7/23/2024 07/23/2024
Misc
Corrective Action Required
07/23/2024
Inspection deny no city stamp plans on site Erosion control not in compliance
Gas Service Inspection - Residential Failed 7/23/2024 7/23/2024 07/23/2024
Misc
Corrective Action Required
07/23/2024
Inspection denied no city stamped plans on site Erosion control, not in compliance
Erosion Control Inspection Residential Failed 7/23/2024 07/23/2024
Misc
Informational
07/12/2024
Erosion control in compliance
DCM5 ESC INSP DENIED
Corrective Action Required
07/23/2024
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. Maintain overgrown vegetation
All Rough Inspection - Residential Failed 7/26/2024 07/26/2024
Misc
Resolved
07/26/2024
-Inspection denied no city stamped plans on site -Maintain overgrown, vegetation in clear debris from garage before scheduling reinspection
Misc
Corrective Action Required
07/26/2024
-will check gb bracing when completed -fire block garage wall into furr down -address holes drilled closer than 2” to one another in joists above garage -double every other other floor joist to plans above garage -missing stud in stud pack at pantry entry under beam -rear kitchen windows not framed to cspf specifications -address rear hearth room wall not built to plans -address holes bored closer than 2” to the bottom of the floor joists and each other above hearth room -add stud to stud pack under lvl at stairs -missing triple floor joist above dining room -fireblock foyer closet into furr down -missing stud at bed 3 exterior wall corner -install h2.5 on lvl above bed 4 both ends, add studs under lvl per plans -ensure dryer vent length does not exceed 35’ -strap top plate where lapped less than 24” owners suit NW corner -seal wall space to ceiling space in owners bath -missing hangers at cantilever floor joists above electrical panel -stair well wall to be framed to plans -bond gas line -revise plans to show as build (plans are for walkout home)
Electrical Service Inspection Passed 7/29/2024 07/29/2024
Misc
Resolved
07/29/2024
Inspection deny no city stamp plans on site Erosion control not in compliance
All Rough Inspection - Residential Failed 8/19/2024 08/19/2024
Misc
Corrective Action Required
07/26/2024
-will check gb bracing when completed -fire block garage wall into furr down -address holes drilled closer than 2” to one another and over bored in joists above garage -rear kitchen windows not framed to cspf specifications -address rear hearth room wall not built to plans -address holes bored closer than 2” to the bottom of the floor joists and each other above hearth room -fireblock foyer closet into furr down -ensure dryer vent length does not exceed 35’ -stair well wall to be framed to plans
All Rough Inspection - Residential Failed 8/29/2024 08/29/2024
Misc
Corrective Action Required
08/19/2024
-will check gb bracing when completed -address holes drilled closer than 2” to one another and over bored in joists above garage -rear kitchen windows not framed to cspf specifications (see plate breaks) -address holes bored closer than 2” to the bottom of the floor joists and each other above hearth room -stair well wall to be framed to plans
All Rough Inspection - Residential Failed 9/5/2024 9/5/2024 09/05/2024
Misc
Corrective Action Required
08/29/2024
-will check gb bracing when completed -address holes drilled closer than 2” to one another and over bored in joists above garage -rear kitchen windows not framed to cspf specifications (see sheathing breaks)
All Rough Inspection - Residential Failed 9/6/2024 9/6/2024 09/06/2024
Misc
Corrective Action Required
09/05/2024
-will check gb bracing when completed with drywall do not mud and tape gb bracing areas Okay to insulate
Gas Service Inspection - Residential Passed 9/10/2024 09/10/2024
Misc
Resolved
09/10/2024
Inspection denied no city stamped plans on site Erosion control, not in compliance
All Rough Inspection - Residential Failed 9/16/2024 09/16/2024
Misc
Corrective Action Required
09/06/2024
09/16/24- GB bracing screw pattern to be to code and plans 7”OC on edges and field -will check gb bracing when completed with drywall do not mud and tape gb bracing areas Okay to insulate
All Rough Inspection - Residential Passed 9/20/2024 9/20/2024 09/20/2024
Misc
Resolved
09/20/2024
09/16/24- GB bracing screw pattern to be to code and plans 7”OC on edges and field -will check gb bracing when completed with drywall do not mud and tape gb bracing areas Okay to insulate
Driveway Inspection Failed 10/11/2024 10/11/2024 10/11/2024
Misc
Corrective Action Required
10/11/2024
10-11-24 Dustin, Dw is formed and compacted. Gravel depth is not deep enough through approach, ( less then 4 in ) need to correct before can pour. Will need to be recalled in for pre pour inspection before poured.
Driveway Inspection Partial 10/14/2024 10/14/2024 10/14/2024
Misc
Corrective Action Required
10/11/2024
10-11-24 Dustin, Dw is formed and compacted. Gravel depth is not deep enough through approach, ( less then 4 in ) need to correct before can pour. Will need to be recalled in for pre pour inspection before poured. 10-14-24 Dustin A, DW recalled in, depths have been corrected, Approved to pour
Driveway Inspection Passed 10/31/2024 10/31/2024 10/30/2024
Misc
Corrective Action Required
10/14/2024
10-11-24 Dustin, Dw is formed and compacted. Gravel depth is not deep enough through approach, ( less then 4 in ) need to correct before can pour. Will need to be recalled in for pre pour inspection before poured. 10-14-24 Dustin A, DW recalled in, depths have been corrected, Approved to pour 10-30-24 Dustin A, Dw is poured to city specs. Passed
Occupancy Inspection - Codes Residential Failed 12/13/2024 12/13/2024 12/13/2024
Misc
Corrective Action Required
12/13/2024
Erosion control not in compliance. Inspection denied.
Occupancy Inspection - Codes Residential Failed 12/16/2024 12/16/2024 12/16/2024
Misc
Corrective Action Required
12/16/2024
-pay all fees -final grade and sod -uncover covered water meter -splash blocks and sump pump discharge to extend 36” from foundation -complete stairs at rear -afci protection for all circuits required by code section
Occupancy Inspection - Codes Residential Ready for Temp CO 12/17/2024 12/17/2024 12/17/2024
Misc
Corrective Action Required
12/16/2024
-pay all fees -final grade and sod -uncover covered water meter -splash blocks and sump pump discharge to extend 36” from foundation -complete stairs at rear. (Stairs and handrail must meet the requirements of code see sections (R311.7.6, R311.7.8.4, R312.1)
Water Service Inspection - R Passed 12/17/2024 12/17/2024
Misc
Resolved
12/17/2024
-Meter is broken needs to be replaced 07/10/24- meter still broken
Erosion Control Inspection Residential Partial 12/17/2024 12/17/2024 12/17/2024
Misc
Informational
07/23/2024
Erosion control in compliance
DCM5 ESC INSP DENIED
Resolved
12/17/2024
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. Maintain overgrown vegetation
Occupancy Inspection - Codes Residential Failed 1/16/2025 01/17/2025
Misc
Corrective Action Required
12/17/2024
-pay all fees -final grade and sod -uncover covered water meter -splash blocks and sump pump discharge to extend 36” from foundation -complete stairs at rear. (Stairs and handrail must meet the requirements of code see sections (R311.7.6, R311.7.8.4, R312.1)
Occupancy Inspection - Codes Residential Ready for Temp CO 1/22/2025 1/22/2025 01/22/2025
Misc
Corrective Action Required
01/17/2025
TCO extension letter uploaded and granted for another 30 days from original TCO -pay all fees -final grade and sod -uncover covered water meter -splash blocks and sump pump discharge to extend 36” from foundation -complete stairs at rear. (Stairs and handrail must meet the requirements of code see sections (R311.7.6, R311.7.8.4, R312.1)
Plot Plan Inspection Failed 2/14/2025 02/14/2025
Misc
Corrective Action Required
02/14/2025
Snow coverage to significant to check grade. Will check at later date.
Occupancy Inspection - Codes Residential Failed 4/9/2025 04/09/2025
Misc
Corrective Action Required
01/22/2025
TCO expired. permit in notice of violation. Mitchell Schwarz 04/09/2025 7:17 AM TCO extension letter uploaded and granted for another 30 days from original TCO -pay all fees -final grade and sod -uncover covered water meter -splash blocks and sump pump discharge to extend 36” from foundation -complete stairs at rear. (Stairs and handrail must meet the requirements of code see sections (R311.7.6, R311.7.8.4, R312.1)
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home