PRRES20232009
Building Permit - Residential
Certificate of Occupancy
NEW DUPLEX
NEW DUPLEX - ROOF TRUSSES - UNFINISHED BASEMENT - COVERED PATIO BASEMENT FINISH FOR 2139 SW OSAGE DR. / 2141 SW OSAGE DR BASEMENT IS UNFINISHED STOP WORK ORDER generated on 07/17/2023 12:00 AM by username 'Kyle Beard'. STOP WORK ORDER removed on 07/21/2023 12:00 AM by username 'Kyle Beard'.
05/04/2023
05/11/2023
11/03/2023
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
Savanna Scarbo, Address:120 SE 30th st, Phone:(816) 434-5074 Ext:321  
SAVANNA@SUMMITHOMESKC.COM  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
CARUTHERS ELECTRICAL LLC, Address:30905 E TRUMAN RD, Phone:(816) 508-9050  
BILL'S PLUMBING SERVICE LLC, Address:308 E PARK STREET, Phone:(913) 829-8213  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee for New Duplex $1,930.79 $1,930.79 Paid 05/11/2023
Sanitary Sewer Development Fee $2,768.00 $2,768.00 Paid 05/11/2023
Right of Way Permit Fee $85.00 $85.00 Paid 05/11/2023
Residential Excise Tax Fee $1,240.32 $1,240.32 Paid 05/11/2023
Water Tap Fee $7,460.00 $7,460.00 Paid 05/11/2023
Water Meter Fee $1,101.00 $1,101.00 Paid 05/11/2023
Additional Permit Fee $174.12 $174.12 Paid 07/06/2023
Not Ready Inspection Fee $75.00 $75.00 Paid 09/15/2023
Temporary Occupancy Fee $50.00 $50.00 Paid 09/29/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 6/5/2023 06/05/2023
Misc
Informational
06/05/2023
Third party signed off the footing inspections at 2139 and 2141 SW Osage. Piers were not signed off by the third party .
Sewer Service Inspection - R Partial 6/15/2023 06/15/2023
Miscellaneous Correction
Informational
06/15/2023
2141 sewer passed. 2139 will be called in another day for inspection
Sewer Service Inspection - R Passed 6/16/2023 6/16/2023 06/16/2023
Miscellaneous Correction
Resolved
06/16/2023
2141 sewer passed. 2139 will be called in another day for inspection
Water Service Inspection - R Passed 6/16/2023 6/16/2023 06/16/2023
Underslab Plumbing Inspection - Residential Passed 7/21/2023 07/21/2023
Miscellaneous Correction
Informational
07/21/2023
Plumbing passed after dye test
Erosion Control Inspection Residential Partial 7/24/2023 07/24/2023
Miscellaneous Correction
Informational
07/24/2023
Erosion control is in place at the time of all rough inspection
All Rough Inspection - Residential Failed 7/24/2023 7/24/2023 07/24/2023
Miscellaneous Correction
Resolved
07/24/2023
All rough could not be completed. Under ground plumbing was never scheduled or inspected. A stop work order on this permit has been placed. 07/17/2023. KBEARD
Miscellaneous Correction
Corrective Action Required
07/24/2023
2139 - Anchor bolts in garage need to be located in the middle 1/3 bottom plate - Two anchor bolts need to be installed at the garage door - Broken stud in garage needs to be addressed - Two trusses in garage needs truss screws installed - Cut back all 2x4 bracing touching the fire rated assembly wall - Bedroom 1 needs a metal nail plate installed at the shower drain - All top plate holes need fire blocking - Truss tie down screws are missing in the master bedroom - Gas bonding is not connected - Boca plate needed in basement bedroom closet - Scabbed on I beam in the basement needs an engineer’s letter of welding and fix - 4 inch metal vent pipe in basement is not attached - LIB in garage needs a correct angle 2141 - LIB in garage needs a correct angle
All Rough Inspection - Residential Failed 7/24/2023 7/24/2023 07/24/2023
Miscellaneous Correction
Resolved
07/24/2023
All rough could not be completed. Under ground plumbing was never scheduled or inspected. A stop work order on this permit has been placed. 07/17/2023. KBEARD
Miscellaneous Correction
Corrective Action Required
07/24/2023
2139 - Anchor bolts in garage need to be located in the middle 1/3 bottom plate - Two anchor bolts need to be installed at the garage door - Broken stud in garage needs to be addressed - Two trusses in garage needs truss screws installed - Cut back all 2x4 bracing touching the fire rated assembly wall - Bedroom 1 needs a metal nail plate installed at the shower drain - All top plate holes need fire blocking - Truss tie down screws are missing in the master bedroom - Gas bonding is not connected - Boca plate needed in basement bedroom closet - Scabbed on I beam in the basement needs an engineer’s letter of welding and fix - 4 inch metal vent pipe in basement is not attached - LIB in garage needs a correct angle 2141 - LIB in garage needs a correct angle
Rated Assembly Inspection Passed 7/24/2023 7/24/2023 07/24/2023
Gas Service Inspection - Residential Passed 7/24/2023 7/24/2023 07/24/2023
Electrical Service Inspection Passed 7/24/2023 7/24/2023 07/24/2023
All Rough Inspection - Residential Passed 7/25/2023 7/25/2023 07/25/2023
Miscellaneous Correction
Resolved
07/25/2023
2139 - Anchor bolts in garage need to be located in the middle 1/3 bottom plate - Two anchor bolts need to be installed at the garage door - Broken stud in garage needs to be addressed - Two trusses in garage needs truss screws installed - Cut back all 2x4 bracing touching the fire rated assembly wall - Bedroom 1 needs a metal nail plate installed at the shower drain - All top plate holes need fire blocking - Truss tie down screws are missing in the master bedroom - Gas bonding is not connected - Boca plate needed in basement bedroom closet - Scabbed on I beam in the basement needs an engineer’s letter of welding and fix - 4 inch metal vent pipe in basement is not attached - LIB in garage needs a correct angle
Driveway Inspection Passed 8/4/2023 8/4/2023 08/08/2023
Misc
Informational
08/04/2023
8-4-23 BR Driveway is formed up and aggregate is place and compacted. 8-8-23 BR Driveway is constructed to LS specification
Sidewalk Inspection Passed 8/4/2023 8/4/2023 08/08/2023
Misc
Informational
08/04/2023
8-4-23 BR Sidewalk is formed up and aggregate is place and compacted. 8-8-23 BR Sidewalk is constructed to LS specification
Piers/Caissons Inspection - Residential Passed 8/11/2023 (8:00) 8/11/2023 08/11/2023
Erosion Control Inspection Residential Failed 8/29/2023 08/29/2023
Miscellaneous Correction
Informational
07/24/2023
Erosion control is in place at the time of all rough inspection
Miscellaneous Correction
Corrective Action Required
08/29/2023
Erosion control is not in place. Full erosion control must be maintained until full CO
Occupancy Inspection - Codes Residential Not Ready 9/6/2023 9/6/2023 09/06/2023
Miscellaneous Correction
Corrective Action Required
09/06/2023
In walking into both properties for inspection I noted that stairwell spindles are not installed and both units are not cleaned to a point that a proper and safe inspection could be accomplished. Walk your property before calling in for inspections and make sure all items are ready for an occupancy inspection. Both units are not ready. THIS IS NOT A COMPLETE LIST 09/06/23 KBEARD 12:40 PM
Occupancy Inspection - Codes Residential Failed 9/26/2023 9/26/2023 09/26/2023
Miscellaneous Correction
Resolved
09/26/2023
In walking into both properties for inspection I noted that stairwell spindles are not installed and both units are not cleaned to a point that a proper and safe inspection could be accomplished. Walk your property before calling in for inspections and make sure all items are ready for an occupancy inspection. Both units are not ready. THIS IS NOT A COMPLETE LIST 09/06/23 KBEARD 12:40 PM
Misc
Corrective Action Required
09/26/2023
2141 and 2139 - Final grading and sod - Sidewalk and driveway inspection pending - Provide splash pads - Obtain irrigation permit if installing 2139 - No functioning water closet - Tighten and break off set screw on anti siphon device at spigot on main water supply
Occupancy Inspection - Codes Residential Failed 9/28/2023 9/28/2023 09/28/2023
Misc
Corrective Action Required
09/26/2023
2141 and 2139 - Final grading and sod - Obtain irrigation permit if installing 2139 - No functioning water closet
Erosion Control Inspection Residential Failed 9/28/2023 09/28/2023
Miscellaneous Correction
Informational
08/29/2023
Erosion control is in place at the time of all rough inspection
Miscellaneous Correction
Corrective Action Required
08/29/2023
Erosion control is not in place. Full erosion control must be maintained until full CO
Miscellaneous Correction
Corrective Action Required
09/28/2023
Erosion control is needed along the west side of the property
Occupancy Inspection - Codes Residential Ready for Temp CO 9/29/2023 9/29/2023 09/29/2023
Misc
Corrective Action Required
09/28/2023
2141 and 2139 - Final grading and sod - Obtain irrigation permit if installing
Occupancy Inspection - Codes Residential Full C of O 11/3/2023 11/3/2023 11/03/2023
Misc
Resolved
11/03/2023
2141 and 2139 - Final grading and sod - Obtain irrigation permit if installing
Documents & Images
Date Uploaded File Type Document Name
05/04/2023 OS #55 - PERMIT APP
05/04/2023 OS #55 Twin Cobalt - Farmhouse - Sheets - signed
05/04/2023 55 osage roof layout
05/04/2023 ROOF SEALS
05/04/2023 LOT 55 FINAL
05/08/2023 Approved Plans APPROVED TRUSS LAYOUT
05/08/2023 Approved Plans APPROVED TRUSS PACKAGE
05/10/2023 Permit Codes Residential Plan Review
05/10/2023 Permit Codes Residential Plan Review
05/11/2023 Permit DS Building Permit
05/11/2023 Permit DS Building Permit
05/11/2023 Receipt Receipt for transaction:2023-003151
06/02/2023 23-06-02_C126 MASTER DRAINAGE PLAN
06/02/2023 23-06-02_Osage 2nd_Lot Type Letter
06/04/2023 M L Crose 2139 & 2141 SW Osage Dr LSMO Footing Inspection Report 5-30-23
06/05/2023 Letter INSPECTION SUMMARY
06/05/2023 Letter INSPECTION SUMMARY
06/05/2023 Letter INSPECTION SUMMARY
06/09/2023 Approved Plans APPROVED PLANS
06/09/2023 Plot Plan approved plot plan
06/15/2023 Letter INSPECTION SUMMARY
06/15/2023 Letter INSPECTION SUMMARY
06/16/2023 Letter INSPECTION SUMMARY
06/16/2023 Letter INSPECTION SUMMARY
06/16/2023 Letter INSPECTION SUMMARY
06/16/2023 Letter INSPECTION SUMMARY
06/28/2023 OS 55 - Basement finish - Scope_of_Work
06/28/2023 OS #55 Twin Cobalt - Farmhouse - Basement Finish - 6_28_23
07/06/2023 Approved Plans APPROVED BASEMENT FINISH
07/06/2023 Receipt Receipt for transaction:2023-005216
07/17/2023 Letter Stop Work Order
07/17/2023 Letter Stop Work Order
07/19/2023 Drain Tile OS-55 Ground Rough
07/19/2023 Osage 55 Missed inspection letter Clover and Hive
07/19/2023 Bill's Plumbing Underslab Inspection Letter
07/20/2023 Drain Tile OS-55 Ground Rough Letter #2
07/21/2023 Letter INSPECTION SUMMARY
07/21/2023 Letter INSPECTION SUMMARY
07/21/2023 Osage 55 Missed inspection letter - Dye Test approval
07/24/2023 Letter INSPECTION SUMMARY
07/24/2023 Letter INSPECTION SUMMARY
07/24/2023 Letter INSPECTION SUMMARY
07/24/2023 Letter INSPECTION SUMMARY
07/24/2023 Letter INSPECTION SUMMARY
07/24/2023 Letter INSPECTION SUMMARY
07/24/2023 Letter INSPECTION SUMMARY
07/24/2023 Letter INSPECTION SUMMARY
07/24/2023 Letter INSPECTION SUMMARY
07/24/2023 Letter INSPECTION SUMMARY
07/24/2023 Letter INSPECTION SUMMARY
07/24/2023 Letter INSPECTION SUMMARY
07/24/2023 Letter INSPECTION SUMMARY
07/24/2023 Letter INSPECTION SUMMARY
07/24/2023 Letter INSPECTION SUMMARY
07/25/2023 Letter INSPECTION SUMMARY
07/25/2023 Letter INSPECTION SUMMARY
07/26/2023 55 OSAGE - BEAM SPLICE - 230725
08/04/2023 Letter INSPECTION SUMMARY
08/04/2023 Letter INSPECTION SUMMARY
08/08/2023 Letter INSPECTION SUMMARY
08/08/2023 Letter INSPECTION SUMMARY
08/11/2023 Letter INSPECTION SUMMARY
08/11/2023 Letter INSPECTION SUMMARY
08/29/2023 Letter INSPECTION SUMMARY
08/29/2023 Letter INSPECTION SUMMARY
09/06/2023 Letter INSPECTION SUMMARY
09/06/2023 Letter INSPECTION SUMMARY
09/15/2023 Receipt Receipt for transaction:2023-007078
09/26/2023 Letter INSPECTION SUMMARY
09/26/2023 Letter INSPECTION SUMMARY
09/28/2023 Letter INSPECTION SUMMARY
09/28/2023 Letter INSPECTION SUMMARY
09/28/2023 Letter INSPECTION SUMMARY
09/28/2023 Letter INSPECTION SUMMARY
09/29/2023 Certificate/License Codes Temporary Certificate of Occupancy
09/29/2023 Certificate/License Codes Temporary Certificate of Occupancy
09/29/2023 Receipt Receipt for transaction:2023-007424
11/03/2023 Letter Codes Final Certificate of Occupancy
11/03/2023 Letter Field Certificate of Occupancy
11/03/2023 Letter Codes Final Certificate of Occupancy
01/29/2024 LOT 55 ASBUILT
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home