Summary
PRRES20231716
Building Permit - Residential
Certificate of Occupancy
CLAYTON PROPERTIES GROUP INC
NEW 3 OR 4 FAMILY
NEW TOWNHOME. FINISHED/UNFINISHED BASEMENT. ROOF TRUSSES.
04/18/2023
04/28/2023
10/17/2023
12/19/2023
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CLAYTON PROPERTIES GROUP INC, Address:120 SE 30TH ST  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
Savanna Scarbo, Address:120 SE 30th st, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
JASONH@CLOVERANDHIVE.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for New 3 or 4 Family $4,011.47 $4,011.47 Paid 04/28/2023
8331401-Water Tap Fee $14,920.00 $14,920.00 Paid 04/28/2023
8350015-Water Meter Fee $2,202.00 $2,202.00 Paid 04/28/2023
8331507-Sanitary Sewer Development Fee $5,536.00 $5,536.00 Paid 04/28/2023
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 04/28/2023
7232302-Residential Excise Tax Fee $2,480.64 $2,480.64 Paid 04/28/2023
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 11/30/2023
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 11/30/2023
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 11/30/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 12/05/2023
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 12/14/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 6/9/2023 06/09/2023
Miscellaneous Correction
Informational
06/09/2023
Third party signed off footing inspections for all four units. Third party did not sign off for any piers
Sewer Service Inspection - R Failed 6/20/2023 6/20/2023 06/20/2023
Misc
Informational
06/20/2023
This is a fourplex, only 2018 sewer is passed at this time, the others will be called in for inspection at later dates. This is a partial pass only.
Sewer Service Inspection - R Failed 6/21/2023 (9:00) 6/21/2023 06/21/2023
Misc
Informational
06/20/2023
This is a fourplex, only 2018 sewer is passed at this time, the others will be called in for inspection at later dates. This is a partial pass only.
Misc
Informational
06/21/2023
Sewer for 2016 and 2014 both passed. 2012 sewer will be called in another day. This is a partial pass only.
Sewer Service Inspection - R Passed 6/21/2023 06/21/2023
Misc
Resolved
06/21/2023
This is a fourplex, only 2018 sewer is passed at this time, the others will be called in for inspection at later dates. This is a partial pass only.
Misc
Resolved
06/21/2023
Sewer for 2016 and 2014 both passed. 2012 sewer will be called in another day. This is a partial pass only.
Water Service Inspection - R Failed 6/22/2023 (1:00) 6/22/2023 06/22/2023
Misc
Informational
06/22/2023
Water lines for all units from the foundation to the meter base which includes the copper line passed. Each meter base and copper to the main will be called in at a later date. This is a partial pass only!
Water Service Inspection - R Passed 6/23/2023 6/23/2023 06/23/2023
Misc
Resolved
06/23/2023
Water lines for all units from the foundation to the meter base which includes the copper line passed. Each meter base and copper to the main will be called in at a later date. This is a partial pass only!
Underslab Plumbing Inspection - Residential Passed 6/26/2023 6/26/2023 06/26/2023
Misc
Informational
06/26/2023
All four units passed under slab plumbing
Underslab Electrical Inspection - Residential Not Ready 6/26/2023 6/26/2023 06/26/2023
Miscellaneous Correction
Corrective Action Required
06/26/2023
Under slab electric is not ready. Electrical work just started as I pulled up for inspection. 2PM. KBEARD
Underslab Electrical Inspection - Residential Passed 6/28/2023 6/28/2023 06/28/2023
Miscellaneous Correction
Resolved
06/28/2023
Under slab electric is not ready. Electrical work just started as I pulled up for inspection. 2PM. KBEARD
Misc
Informational
06/28/2023
All four units passed for under slab electrical
All Rough Inspection - Residential Failed 8/16/2023 8/16/2023 08/16/2023
Miscellaneous Correction
Corrective Action Required
08/16/2023
2016 - CSPF straps missing on back wall 2014 - CSPF straps missing on back wall 2012 - CSPF straps missing on back wall - One CSPF strap missing in garage
Erosion Control Inspection Residential Failed 8/16/2023 08/16/2023
Miscellaneous Correction
Corrective Action Required
08/16/2023
Full erosion control is missing, torn down or not installed and mud clods and gravel is in the street. Clean streets and install full erosion control. 08/16/2023. KBEARD
Erosion Control Inspection Residential Failed 8/29/2023 08/29/2023
Miscellaneous Correction
Corrective Action Required
08/16/2023
Full erosion control is missing, torn down or not installed and mud clods and gravel is in the street. Clean streets and install full erosion control. 08/16/2023. KBEARD
Miscellaneous Correction
Corrective Action Required
08/29/2023
Full property erosion control is missing, torn down or never installed. Erosion control must be in place and maintained until full CO. Install perimeter erosion control and remove dirt and gravel from the streets. No inspections will be completed until full erosion control is in place. 08/29/2023 KBEARD
Rated Assembly Inspection Not Ready 9/14/2023 9/14/2023 09/14/2023
Miscellaneous Correction
Corrective Action Required
09/14/2023
2018 - top plate in garage east wall needs to be sealed with fire blocking - seal all exposed plywood wood that is missing (chipped) in the white flame blocking material 2016 - seal all exposed plywood wood that is missing (chipped) in the white flame blocking material - basement under the stairs at the top plate is missing fire blocking 2014 - seal all exposed plywood that is missing (chipped) in the white fire flame blocking material - seal garage top plate west side under fur down - vertical fire blocking in stud cavity in basement west wall for a 10 foot separation is not complete - repair torn paper in the gypsum rock on the east wall by bedroom - address metal channel about five feet south of the east wall ridge 2012 Rated assembly was still being sealed by a contractor and could not be fully inspected. THIS IS NOT A COMPLETE LIST Not ready 09/14/2023 KBEARD 9:45am
Rated Assembly Inspection Failed 9/15/2023 9/15/2023 09/15/2023
Miscellaneous Correction
Corrective Action Required
09/14/2023
2018 - top plate in garage east wall needs to be sealed with fire blocking - seal all exposed plywood wood that is missing (chipped) in the white flame blocking material 2016 - seal all exposed plywood wood that is missing (chipped) in the white flame blocking material - basement under the stairs at the top plate is missing fire blocking 2014 - seal all exposed plywood that is missing (chipped) in the white fire flame blocking material - seal garage top plate west side under fur down - vertical fire blocking in stud cavity in basement west wall for a 10 foot separation is not complete - repair torn paper in the gypsum rock on the east wall by bedroom - address metal channel about five feet south of the east wall ridge 2012 Rated assembly was still being sealed by a contractor and could not be fully inspected. THIS IS NOT A COMPLETE LIST Not ready 09/14/2023 KBEARD 9:45am
Miscellaneous Correction
Corrective Action Required
09/15/2023
2018 - top plate in garage east wall needs to be sealed with fire blocking - seal all exposed plywood wood that is missing (chipped) in the white flame blocking material 2016 - seal all exposed plywood wood that is missing (chipped) in the white flame blocking material - basement under the stairs at the top plate is missing fire blocking 2014 - seal all exposed plywood that is missing (chipped) in the white fire flame blocking material - seal garage top plate west side under fur down - vertical fire blocking in stud cavity in basement west wall for a 10 foot separation is not complete - repair torn paper in the gypsum rock on the east wall by bedroom - address metal channel about five feet south of the east wall ridge 2012 Seal all exposed plywood that is missing (chipped) in the white fire flame blocking material
All Rough Inspection - Residential Failed 9/14/2023 9/15/2023 09/15/2023
Miscellaneous Correction
Resolved
09/15/2023
2016 - CSPF straps missing on back wall 2014 - CSPF straps missing on back wall 2012 - CSPF straps missing on back wall - One CSPF strap missing in garage
Miscellaneous Correction
Corrective Action Required
09/15/2023
2012 Fire blocking in garage chase at top plate Electrical nail plate is needed in the entry closet upper top plate Fire caulking is needed in the basement top plate to 3/4 plywood Basement HVAC needs a longer condensation pipe Electrical nail plate needed in pantry LIB in master bathroom is not correct. They must be connected to the top plate 2014 Anchor bolts in garage need to be tightened down Fire blocking is missing in garage west side top plate at rated assembly Fire blocking is needed in garage chase top plate Fire blocking is needed in basement north wall top plate gap Tightened down basement anchor nuts Install anti siphon valve Top plate in HVAC room needs to be sealed Wall stud going up the stairs to the main living area is broken 3/4 of the way through Address broken truss top cord 2016 Fire block all gaps at the top plate in the basement north wall Plumbing nail plate is needed in the basement west bedroom SE corner BOCA plate needed in basement bathroom plumbing drain line Anti siphon valve is needed Plumbing pipe is in the attic access and will not allow proper clearance LIB in master bathroom is not connected to the top plate LIB in master bedroom/bathroom is cut 2018 Garage anchor bolts must be located in the middle 1/3 of bottom plate Fire block in gap in basement top plate in exterior walls Anti siphon valve is needed LIB in master bathroom is not attached to the top plate
Electrical Service Inspection Passed 9/14/2023 9/15/2023 09/15/2023
Gas Service Inspection - Residential Passed 9/14/2023 9/15/2023 09/15/2023
All Rough Inspection - Residential Failed 9/20/2023 09/20/2023
Miscellaneous Correction
Corrective Action Required
09/15/2023
2012 Basement HVAC needs a longer condensation pipe 2014 Install anti siphon valve Address broken truss top cord. Engineers report sent, but recommend repair was not completed 2016 Anti siphon valve is needed LIB in master bedroom/bathroom is cut 2018 Anti siphon valve is needed
Rated Assembly Inspection Failed 9/20/2023 09/20/2023
Miscellaneous Correction
Corrective Action Required
09/15/2023
2018 - seal all exposed plywood wood that is missing (chipped) in the white flame blocking material 2016 - seal all exposed plywood wood that is missing (chipped) in the white flame blocking material 2014 - seal all exposed plywood that is missing (chipped) in the white fire flame blocking material - address metal channel about five feet south of the east wall ridge 2012 Rated assembly was still being sealed by a contractor and could not be fully inspected. THIS IS NOT A COMPLETE LIST Not ready 09/14/2023 KBEARD 9:45am
Miscellaneous Correction
Corrective Action Required
09/15/2023
2018 - seal all exposed plywood wood that is missing (chipped) in the white flame blocking material 2016 - seal all exposed plywood wood that is missing (chipped) in the white flame blocking material 2014 - seal all exposed plywood that is missing (chipped) in the white fire flame blocking material - address metal channel about five feet south of the east wall ridge 2012 Seal all exposed plywood that is missing (chipped) in the white fire flame blocking material
All Rough Inspection - Residential Not Ready 9/22/2023 9/22/2023 09/22/2023
Miscellaneous Correction
Corrective Action Required
09/20/2023
2012 Basement HVAC needs a longer condensation pipe 2014 Address broken truss top cord. Engineers report sent, but recommend repair was not completed 2016 LIB in master bedroom/bathroom is cut
Erosion Control Inspection Residential Partial 9/22/2023 09/22/2023
Miscellaneous Correction
Resolved
09/22/2023
Full erosion control is missing, torn down or not installed and mud clods and gravel is in the street. Clean streets and install full erosion control. 08/16/2023. KBEARD
Miscellaneous Correction
Resolved
09/22/2023
Full property erosion control is missing, torn down or never installed. Erosion control must be in place and maintained until full CO. Install perimeter erosion control and remove dirt and gravel from the streets. No inspections will be completed until full erosion control is in place. 08/29/2023 KBEARD
Misc
Informational
09/22/2023
Erosion control is in place at the time of all rough
Rated Assembly Inspection Passed 9/22/2023 9/22/2023 09/22/2023
Miscellaneous Correction
Resolved
09/22/2023
2018 - seal all exposed plywood wood that is missing (chipped) in the white flame blocking material 2016 - seal all exposed plywood wood that is missing (chipped) in the white flame blocking material 2014 - seal all exposed plywood that is missing (chipped) in the white fire flame blocking material - address metal channel about five feet south of the east wall ridge 2012 Rated assembly was still being sealed by a contractor and could not be fully inspected. THIS IS NOT A COMPLETE LIST Not ready 09/14/2023 KBEARD 9:45am
Miscellaneous Correction
Resolved
09/22/2023
2018 - seal all exposed plywood wood that is missing (chipped) in the white flame blocking material 2016 - seal all exposed plywood wood that is missing (chipped) in the white flame blocking material 2014 - seal all exposed plywood that is missing (chipped) in the white fire flame blocking material - address metal channel about five feet south of the east wall ridge 2012 Seal all exposed plywood that is missing (chipped) in the white fire flame blocking material
All Rough Inspection - Residential Passed 9/25/2023 9/25/2023 09/25/2023
Miscellaneous Correction
Resolved
09/25/2023
2012 Basement HVAC needs a longer condensation pipe 2014 Address broken truss top cord. Engineers report sent, but recommend repair was not completed 2016 LIB in master bedroom/bathroom is cut
Driveway Inspection Partial 10/4/2023 10/4/2023 10/04/2023
Misc
Informational
10/04/2023
10-4-23 Dustin A, DW's are formed.( units 2018 thru 2012 ) Aggregate is compacted. Slopes are in compliance . Conditions can change. Approved to pour
Sidewalk Inspection Partial 10/4/2023 10/4/2023 10/04/2023
Misc
Informational
10/04/2023
10-4-23 Dustin A, SW'S are formed. ( units 2018 thru 2012 ). Aggregate is formed and slopes are in compliance. Conditions can change. Approved to pour
Rated Assembly Inspection Failed 10/4/2023 10/04/2023
Miscellaneous Correction
Informational
10/04/2023
Rated assembly screw pattern in unit 2018 passed. Ok to cover
Rated Assembly Inspection Failed 10/5/2023 10/5/2023 10/05/2023
Miscellaneous Correction
Informational
10/04/2023
Rated assembly screw pattern in unit 2018 passed. Ok to cover
Miscellaneous Correction
Corrective Action Required
10/05/2023
-Fire rated assembly sheet rock in basement of 2014 under stairs is not completed - Piece of fire rated assembly sheet rock is broken in 2014 garage and is to large to just fill it with mud - Gaps in fire rated assembly sheet rock larger than 1/4 of an inch must be replaced with closer gaps in unit 2014
Rated Assembly Inspection Failed 10/6/2023 10/6/2023 10/06/2023
Miscellaneous Correction
Informational
10/05/2023
Rated assembly screw pattern in unit 2018 passed. Ok to cover
Miscellaneous Correction
Corrective Action Required
10/05/2023
- Piece of fire rated assembly sheet rock is broken in 2014 garage and is to large to just fill it with mud - Gaps in fire rated assembly sheet rock larger than 1/4 of an inch must be replaced with closer gaps in unit 2014
Rated Assembly Inspection Passed 10/9/2023 10/10/2023 10/10/2023
Miscellaneous Correction
Informational
10/06/2023
Rated assembly screw pattern in unit 2018 passed. Ok to cover
Miscellaneous Correction
Resolved
10/10/2023
- Piece of fire rated assembly sheet rock is broken in 2014 garage and is to large to just fill it with mud - Gaps in fire rated assembly sheet rock larger than 1/4 of an inch must be replaced with closer gaps in unit 2014
Driveway Inspection Passed 10/11/2023 10/11/2023 10/11/2023
Misc
Informational
10/04/2023
10-4-23 Dustin A, DW's are formed.( units 2018 thru 2012 ) Aggregate is compacted. Slopes are in compliance . Conditions can change. Approved to pour 10-11-23 Dustin A, DW's are poured. Frames are pulled. Slopes are in compliance. Passed
Sidewalk Inspection Partial 10/11/2023
Misc
Informational
10/04/2023
10-4-23 Dustin A, SW'S are formed. ( units 2018 thru 2012 ). Aggregate is formed and slopes are in compliance. Conditions can change. Approved to pour 10-11-23 SW'S are poured for 2018 thru 2014. forms are pulled and slopes are in compliance . will need to still pour 2012
Sidewalk Inspection Partial 10/18/2023 10/18/2023 10/17/2023
Misc
Informational
10/11/2023
10-4-23 Dustin A, SW'S are formed. ( units 2018 thru 2012 ). Aggregate is formed and slopes are in compliance. Conditions can change. Approved to pour 10-11-23 SW'S are poured for 2018 thru 2014. forms are pulled and slopes are in compliance . will need to still pour 2012 10-17-23 Dustin A, Conditions have not changed.
Sidewalk Inspection Partial 10/17/2023 10/17/2023 10/17/2023
Misc
Informational
10/17/2023
10-4-23 Dustin A, SW'S are formed. ( units 2018 thru 2012 ). Aggregate is formed and slopes are in compliance. Conditions can change. Approved to pour 10-11-23 SW'S are poured for 2018 thru 2014. forms are pulled and slopes are in compliance . will need to still pour 2012 10-17-23 Dustin A, Conditions have not changed. 10-17-23 Dustin A, Last section is formed and compacted. approved to pour.
Sidewalk Inspection Passed 10/23/2023 10/23/2023 10/23/2023
Misc
Informational
10/17/2023
10-4-23 Dustin A, SW'S are formed. ( units 2018 thru 2012 ). Aggregate is formed and slopes are in compliance. Conditions can change. Approved to pour 10-11-23 SW'S are poured for 2018 thru 2014. forms are pulled and slopes are in compliance . will need to still pour 2012 10-17-23 Dustin A, Conditions have not changed. 10-17-23 Dustin A, Last section is formed and compacted. approved to pour. 10-23-23 Dustin A, SW is poured. Slopes are in compliance . Passed.
Piers/Caissons Inspection - Residential Partial 11/6/2023 (1:00) 11/6/2023 11/06/2023
Miscellaneous Correction
Informational
11/06/2023
This is a partial pass for piers located at 2012 SW Holdbrooks. The back deck corner piers passed only. The piers for the stairs were not dug at the time of this inspection. No others piers for the other addresses were called in for inspection.
Piers/Caissons Inspection - Residential Partial 11/7/2023 11/7/2023 11/07/2023
Miscellaneous Correction
Informational
11/06/2023
This is a partial pass for piers located at 2012 SW Holdbrooks. The back deck corner piers passed only. The piers for the stairs were not dug at the time of this inspection. No others piers for the other addresses were called in for inspection. 2012 All piers passed for back deck and stairs. This is a partial pass for piers only. Other units will be call in when ready. 11/07/23 KBEARD
Piers/Caissons Inspection - Residential Partial 11/7/2023 (2:00) 11/7/2023 11/07/2023
Miscellaneous Correction
Informational
11/07/2023
This is a partial pass for piers located at 2012 SW Holdbrooks. The back deck corner piers passed only. The piers for the stairs were not dug at the time of this inspection. No others piers for the other addresses were called in for inspection. 2012 All piers passed for back deck and stairs. This is a partial pass for piers only. Other units will be call in when ready. 11/07/23 KBEARD
Miscellaneous Correction
Informational
11/07/2023
2014 Back deck piers passed. This is a partial pass only. Other units will be called in at a later date
Erosion Control Inspection Residential Failed 11/9/2023 11/09/2023
Misc
Informational
09/22/2023
Erosion control is in place at the time of all rough
Miscellaneous Correction
Corrective Action Required
11/09/2023
Erosion control along the west side of the property is needed. The front has sidewalks and driveways and the east side at this time has another lot that is being built on and both share a dirt lot.
Piers/Caissons Inspection - Residential Partial 11/9/2023 (8:00) 11/9/2023 11/09/2023
Miscellaneous Correction
Informational
11/07/2023
This is a partial pass for piers located at 2012 SW Holdbrooks. The back deck corner piers passed only. The piers for the stairs were not dug at the time of this inspection. No others piers for the other addresses were called in for inspection. 2012 All piers passed for back deck and stairs. This is a partial pass for piers only. Other units will be call in when ready. 11/07/23 KBEARD
Miscellaneous Correction
Informational
11/07/2023
2014 Back deck piers passed. This is a partial pass only. Other units will be called in at a later date
Miscellaneous Correction
Informational
11/09/2023
2016 piers passed for the back deck.This is a partial pass only.
Piers/Caissons Inspection - Residential Passed 11/10/2023 11/10/2023 11/10/2023
Miscellaneous Correction
Informational
11/09/2023
This is a partial pass for piers located at 2012 SW Holdbrooks. The back deck corner piers passed only. The piers for the stairs were not dug at the time of this inspection. No others piers for the other addresses were called in for inspection. 2012 All piers passed for back deck and stairs. This is a partial pass for piers only. Other units will be call in when ready. 11/07/23 KBEARD
Miscellaneous Correction
Informational
11/09/2023
2014 Back deck piers passed. This is a partial pass only. Other units will be called in at a later date
Miscellaneous Correction
Informational
11/09/2023
2016 piers passed for the back deck.This is a partial pass only.
Occupancy Inspection - Codes Residential Failed 11/30/2023 11/30/2023 11/30/2023
Miscellaneous Correction
Corrective Action Required
11/30/2023
2018 occupancy Exterior of house was not inspected 2016 electrical box under sink needs to be secured Microwave plug in has a gap behind the plate Gas line rubs against a/c line in the basement Seal penetration above the garage interior overhead door Exterior of house was not inspected 2014 First to second riser height going up from the entrance platform has a difference of 3/4 of an inch. IRC allows 3/8 difference Stairwell wall clearance from entry platform to living/kitchen is 35 3/4 inches wide. IRC requires a minimum clearance of head room at 36 inches Upper stairs at kitchen/living rooms to bedroom first to second riser has a height difference of 1/2 inch. IRC allows 3/8 maximum height difference Under stair to sump pump needs to be fire blocked (panel is missing) Seal all ceiling penetrations in garage Garage door to house is missing it’s weather seal Exterior of house was not inspected 2012 stove anti tip bracket is not working Garage to house stairs are not installed Seal all interior garage ceiling penetration Exterior of house was not inspected
Occupancy Inspection - Codes Residential Failed 12/1/2023 12/1/2023 12/01/2023
Miscellaneous Correction
Corrective Action Required
11/30/2023
2018 occupancy Exterior of house was not inspected 2016 electrical box under sink needs to be secured Microwave plug in has a gap behind the plate Gas line rubs against a/c line in the basement Seal penetration above the garage interior overhead door Exterior of house was not inspected 2014 First to second riser height going up from the entrance platform has a difference of 3/4 of an inch. IRC allows 3/8 difference Stairwell wall clearance from entry platform to living/kitchen is 35 3/4 inches wide. IRC requires a minimum clearance of head room at 36 inches Upper stairs at kitchen/living rooms to bedroom first to second riser has a height difference of 1/2 inch. IRC allows 3/8 maximum height difference Under stair to sump pump needs to be fire blocked (panel is missing) Seal all ceiling penetrations in garage Garage door to house is missing it’s weather seal Exterior of house was not inspected 2012 stove anti tip bracket is not working Garage to house stairs are not installed Seal all interior garage ceiling penetration Exterior of house was not inspected
Miscellaneous Correction
Corrective Action Required
12/01/2023
2018 Exterior of house was not ready for inspection Inside of house passed for TCO only 2016 Exterior of house was not ready for inspection Inside of house passed for TCO only 2014 -First to second riser height going up from the entrance platform has a difference of 3/4 of an inch. IRC allows 3/8 of an inch difference -Upper stairs at kitchen/living room to bedrooms, first to second riser has a height difference of 1/2 inch. IRC allows 3/8 maximum height difference -Exterior of house was not ready for inspection 2012 -Garage to house door will not fully close with the self closing hinge -Exterior of house was not ready for inspection TCO passed on 2016 and 2018 only. This is a partial pass only
Erosion Control Inspection Residential Failed 12/4/2023 12/04/2023
Misc
Informational
11/09/2023
Erosion control is in place at the time of all rough
Miscellaneous Correction
Corrective Action Required
11/09/2023
Erosion control along the west side of the property is needed. The front has sidewalks and driveways and the east side at this time has another lot that is being built on and both share a dirt lot.
Miscellaneous Correction
Corrective Action Required
12/04/2023
Erosion control along the west side of the property is needed. The front has sidewalks and driveways and the east side at this time has another lot that is being built on and both share a dirt lot. 12/04/23 KBEARD
Occupancy Inspection - Codes Residential Ready for Temp CO 12/4/2023 12/4/2023 12/04/2023
Miscellaneous Correction
Resolved
12/04/2023
2018 occupancy Exterior of house was not inspected 2016 electrical box under sink needs to be secured Microwave plug in has a gap behind the plate Gas line rubs against a/c line in the basement Seal penetration above the garage interior overhead door Exterior of house was not inspected 2014 First to second riser height going up from the entrance platform has a difference of 3/4 of an inch. IRC allows 3/8 difference Stairwell wall clearance from entry platform to living/kitchen is 35 3/4 inches wide. IRC requires a minimum clearance of head room at 36 inches Upper stairs at kitchen/living rooms to bedroom first to second riser has a height difference of 1/2 inch. IRC allows 3/8 maximum height difference Under stair to sump pump needs to be fire blocked (panel is missing) Seal all ceiling penetrations in garage Garage door to house is missing it’s weather seal Exterior of house was not inspected 2012 stove anti tip bracket is not working Garage to house stairs are not installed Seal all interior garage ceiling penetration Exterior of house was not inspected
Miscellaneous Correction
Resolved
12/04/2023
2018 Exterior of house was not ready for inspection Inside of house passed for TCO only 2016 Exterior of house was not ready for inspection Inside of house passed for TCO only 2014 -First to second riser height going up from the entrance platform has a difference of 3/4 of an inch. IRC allows 3/8 of an inch difference -Upper stairs at kitchen/living room to bedrooms, first to second riser has a height difference of 1/2 inch. IRC allows 3/8 maximum height difference -Exterior of house was not ready for inspection 2012 -Garage to house door will not fully close with the self closing hinge -Exterior of house was not ready for inspection TCO passed on 2016 and 2018 only. This is a partial pass only
Miscellaneous Correction
Corrective Action Required
12/04/2023
All units passed for TCO Exterior of each property has not been inspected 12/04/23 KBEARD
Plot Plan Inspection Passed 12/8/2023 12/08/2023
Erosion Control Inspection Residential Passed 12/8/2023 12/08/2023
Misc
Informational
12/04/2023
Erosion control is in place at the time of all rough
Miscellaneous Correction
Resolved
12/08/2023
Erosion control along the west side of the property is needed. The front has sidewalks and driveways and the east side at this time has another lot that is being built on and both share a dirt lot.
Miscellaneous Correction
Resolved
12/08/2023
Erosion control along the west side of the property is needed. The front has sidewalks and driveways and the east side at this time has another lot that is being built on and both share a dirt lot. 12/04/23 KBEARD
Occupancy Inspection - Codes Residential Failed 12/8/2023 12/8/2023 12/08/2023
Miscellaneous Correction
Corrective Action Required
12/04/2023
All units passed for TCO Exterior of each property has not been inspected 12/04/23 KBEARD
Miscellaneous Correction
Corrective Action Required
12/08/2023
-Seal all exterior penetrations -Install anti siphon valve on exterior ac units -permit is required for lawn irrigation system already installed
Occupancy Inspection - Codes Residential Not Ready 12/12/2023 12/12/2023 12/12/2023
Miscellaneous Correction
Corrective Action Required
12/08/2023
All units passed for TCO Exterior of each property has not been inspected 12/04/23 KBEARD
Miscellaneous Correction
Corrective Action Required
12/08/2023
-Seal all exterior penetrations -Install anti siphon valve on exterior ac units -permit is required for lawn irrigation system already installed
Miscellaneous Correction
Corrective Action Required
12/12/2023
-Install anti siphon valve on exterior ac units -permit is required for lawn irrigation system already installed
Occupancy Inspection - Codes Residential Full C of O 12/19/2023 12/19/2023 12/19/2023
Miscellaneous Correction
Resolved
12/19/2023
All units passed for TCO Exterior of each property has not been inspected 12/04/23 KBEARD
Miscellaneous Correction
Resolved
12/19/2023
-Seal all exterior penetrations -Install anti siphon valve on exterior ac units -permit is required for lawn irrigation system already installed
Miscellaneous Correction
Resolved
12/19/2023
-Install anti siphon valve on exterior ac units -permit is required for lawn irrigation system already installed
Documents & Images
Date Uploaded File Type Document Name
04/18/2023 OS #4 - PERMIT APP
04/20/2023 Permit Codes Residential Plan Review
04/20/2023 Permit Codes Residential Plan Review
04/26/2023 Plot Plan APPROVED PLOT PLAN
04/26/2023 Approved Plans APPROVED PLANS
04/26/2023 Approved Plans APPROVED TRUSS LAYOUT
04/26/2023 Approved Plans APPROVED TRUSS PACKAGE
04/26/2023 Permit Codes Residential Plan Review
04/28/2023 Permit DS Building Permit
04/28/2023 Receipt Receipt for transaction:2023-002492
06/09/2023 2012-2018 SW Holdbrooks Dr LSMO Osage Lot 4 Clayton Properties P 2023-1716 3rd Party Footing Inspection Report 6-8-23
06/09/2023 Letter INSPECTION SUMMARY
06/20/2023 Letter INSPECTION SUMMARY
06/21/2023 Letter INSPECTION SUMMARY
06/21/2023 Letter INSPECTION SUMMARY
06/22/2023 Letter INSPECTION SUMMARY
06/23/2023 Letter INSPECTION SUMMARY
06/26/2023 Letter INSPECTION SUMMARY
06/26/2023 Letter INSPECTION SUMMARY
06/28/2023 Letter INSPECTION SUMMARY
08/16/2023 Letter INSPECTION SUMMARY
08/16/2023 Letter INSPECTION SUMMARY
08/16/2023 Letter INSPECTION SUMMARY
08/29/2023 Letter INSPECTION SUMMARY
09/14/2023 Letter INSPECTION SUMMARY
09/15/2023 Letter INSPECTION SUMMARY
09/15/2023 Letter INSPECTION SUMMARY
09/15/2023 Letter INSPECTION SUMMARY
09/15/2023 Letter INSPECTION SUMMARY
09/15/2023 ENG-ROOF-repair broken chord on gable
09/20/2023 Letter INSPECTION SUMMARY
09/20/2023 Letter INSPECTION SUMMARY
09/22/2023 Letter INSPECTION SUMMARY
09/22/2023 Letter INSPECTION SUMMARY
09/22/2023 Letter INSPECTION SUMMARY
09/25/2023 Letter INSPECTION SUMMARY
10/04/2023 Letter INSPECTION SUMMARY
10/04/2023 Letter INSPECTION SUMMARY
10/04/2023 Letter INSPECTION SUMMARY
10/05/2023 Letter INSPECTION SUMMARY
10/06/2023 Letter INSPECTION SUMMARY
10/10/2023 Letter INSPECTION SUMMARY
10/11/2023 Letter INSPECTION SUMMARY
10/11/2023 Letter INSPECTION SUMMARY
10/17/2023 Letter INSPECTION SUMMARY
10/17/2023 Letter INSPECTION SUMMARY
10/23/2023 Letter INSPECTION SUMMARY
11/06/2023 Letter INSPECTION SUMMARY
11/07/2023 Letter INSPECTION SUMMARY
11/07/2023 Letter INSPECTION SUMMARY
11/09/2023 Letter INSPECTION SUMMARY
11/09/2023 Letter INSPECTION SUMMARY
11/10/2023 Letter INSPECTION SUMMARY
11/30/2023 Letter INSPECTION SUMMARY
11/30/2023 Receipt Receipt for transaction:2023-008805
12/01/2023 Letter INSPECTION SUMMARY
12/04/2023 Letter INSPECTION SUMMARY
12/05/2023 Certificate/License Codes Temporary Certificate of Occupancy
12/05/2023 Receipt Receipt for transaction:2023-008874
12/08/2023 Letter INSPECTION SUMMARY
12/08/2023 Letter INSPECTION SUMMARY
12/08/2023 Letter INSPECTION SUMMARY
12/12/2023 Letter INSPECTION SUMMARY
12/14/2023 Receipt Receipt for transaction:2023-009104
12/19/2023 Letter Codes Final Certificate of Occupancy
12/19/2023 Letter Field Certificate of Occupancy
01/29/2024 LOT 4 ASBUILT ROUGH
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home