Summary
PRRES20215979
Building Permit - Residential
Certificate of Occupancy
CLAYTON PROPERTIES GROUP INC
NEW SINGLE FAMILY
NEW HOUSE. COVERED DECK. WALK OUT BASEMENT. FINISHED/UNFINISHED BASEMENT. SUSPENDED SLAB. STOP WORK ORDER generated on 05/30/2023 12:00 AM by username 'Shawn Hoffman'. STOP WORK ORDER removed on 06/02/2023 12:00 AM by username 'Shawn Hoffman'.
11/16/2021
02/22/2022
05/21/2022
08/15/2023
Locations
Contacts
KC CUSTOM HOMES, Address:406 NW DONOVAN RD, Phone:(816) 564-5149  
CLAYTON PROPERTIES GROUP INC, Address:120 SE 30TH ST  
Steve Froehlich, Address:406 NW Donovan Rd  
A & D HEATING AND COOLING INC, Address:2006 W MAIN ST, Phone:(816) 537-7952  
ADVANCED ELECTRICAL LLC, Address:PO BOX 1573, Phone:(816) 347-8187  
A BRIGHT PLUMBING LLC, Address:18107 E 18TH TER N, Phone:(816) 215-0730  
STEVE@KC-CUSTOMHOMES.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $510.00 $510.00 Paid 02/22/2022
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 02/22/2022
8350015-Water Meter Fee $479.24 $479.24 Paid 02/22/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 02/22/2022
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 02/22/2022
9110078-Valuation Fee New Single Family $1,189.23 $1,189.23 Paid 02/22/2022
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 01/24/2023
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 01/24/2023
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 06/28/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 07/13/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 2/22/2022 (2:00) 2/22/2022 02/22/2022
Misc
Informational
02/22/2022
UFER LOCATED NORTH FOUNDATION WALL OF GARAGE
Sewer Service Inspection - R Passed 3/29/2022 (1:00) 3/29/2022 03/29/2022
Underslab Plumbing Inspection - Residential Passed 3/31/2022 3/31/2022 03/31/2022
Water Service Inspection - R Passed 4/1/2022 (1:15) 4/1/2022 04/01/2022
Erosion Control Inspection Residential Failed 12/19/2022 12/19/2022 12/19/2022
DCM5 ESC INSP DENIED
Corrective Action Required
12/19/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION.
Electrical Service Inspection Failed 12/19/2022 12/19/2022 12/19/2022
Misc
Corrective Action Required
12/19/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION.
Gas Service Inspection - Residential Failed 12/19/2022 12/19/2022 12/19/2022
Misc
Corrective Action Required
12/19/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION.
All Rough Inspection - Residential Not Ready 12/19/2022 12/19/2022 12/19/2022
Misc
Corrective Action Required
12/19/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. MAINTAIN EROSION CONTROL ON LOT
All Rough Inspection - Residential Failed 1/11/2023 1/11/2023 01/11/2023
Misc
Corrective Action Required
12/19/2022
1/11/23-House is not ready for inspection, address these items before reshceduling inspection: LI -Address deck attached to cantilever -Address deck post to beam connections -Provide all hangers and ledger connections -Missing nut and washer at garage door anchor bolts -Tighten anchor bolts PfH -Nail top plate to header at PFH per detail -Provide anchor bolts within 12” of plate breaks -Connect bath fan through roof -Provide joist hanger at tail joist in garage near master closet -Strap top plate lapped less than 24” in. Garage by entry door -Nail ceiling joist to rafters per code -Address load bearing stud cut short of bottom plate under beam in garage -Fireblock ceiling line at entry closet -Protect dryer duct 2” below plate line at laundry -Seal plate penetrations throughout master bath, master shower -Protect pex at master -Remove abandoned vent at roof penetration and repair roof at master -Complete all dwv at master -Fireblock ceiling line throughout great room, kitchen, etc -Fireblock stud space to attic at fireplace -Seal penetrations in stud space return air cavities -Move sheet rock to provide access to all areas -Security blocking at entry doors
All Rough Inspection - Residential Failed 1/11/2023 01/11/2023
Misc
Corrective Action Required
01/11/2023
1/11/23-House is not ready for inspection, address these items before reshceduling inspection: LIST IS INCOMPLETE -Address deck attached to cantilever -Address deck post to beam connections -Provide all hangers and ledger connections -Missing nut and washer at garage door anchor bolts -Tighten anchor bolts PfH -Nail top plate to header at PFH per detail -Provide anchor bolts within 12” of plate breaks -Connect bath fan through roof -Provide joist hanger at tail joist in garage near master closet -Strap top plate lapped less than 24” in. Garage by entry door -Nail ceiling joist to rafters per code -Address load bearing stud cut short of bottom plate under beam in garage -Fireblock ceiling line at entry closet -Protect dryer duct 2” below plate line at laundry -Seal plate penetrations throughout master bath, master shower -Protect pex at master -Remove abandoned vent at roof penetration and repair roof at master -Complete all dwv at master -Fireblock ceiling line throughout great room, kitchen, etc -Fireblock stud space to attic at fireplace -Seal penetrations in stud space return air cavities -Move sheet rock to provide access to all areas -Security blocking at entry doors
All Rough Inspection - Residential Not Ready 1/19/2023 1/20/2023 01/20/2023
Misc
Corrective Action Required
01/11/2023
1/11/23-House is not ready for inspection, address these items before reshceduling inspection: LIST IS INCOMPLETE -Address deck attached to cantilever-NOT DONE -Address deck post to beam connections-NOT DONE -Provide all hangers and ledger connections-NOT DONE -Nail top plate to header at PFH per detail-NOT DONE -Provide joist hanger at tail joist in garage near master closet-NOT DONE -Strap top plate lapped less than 24” in. Garage by entry door-NOT DONE -Nail ceiling joist to rafters per code -Address load bearing stud cut short of bottom plate under beam in garage -NOT DONE -Fireblock ceiling line at entry closet-If this is your ceiling framing your joists are 36” oc -Protect dryer duct 2” below plate line at laundry-NOT DONE -Seal plate penetrations throughout master bath, master shower-NOT DONE -Protect pex at master-NOT DONE -Remove abandoned vent at roof penetration and repair roof at master -Complete all dwv at master-NOT DONE -Fireblock ceiling line throughout great room, kitchen, etc-NOT DONE -Fireblock stud space to attic/ceiling space at fireplace-NOT DONE -Seal penetrations in stud space return air cavities -Move sheet rock to provide access to all areas -NOT DONE -Security blocking at entry doors-NOT DONE ****1/20/23 At this point through the list there are still too many items not completed to continue this inspection. A not ready fee will be accessed. Please walk through this house and ensure it is ready for inspection before reshceduling.
All Rough Inspection - Residential Failed 1/25/2023 1/25/2023 01/25/2023
Misc
Corrective Action Required
01/20/2023
-Address deck attached to cantilever-NOT DONE -Address deck post to beam connections-NOT DONE -Protect dryer duct 2” below plate line at laundry-NOT DONE -Seal plate penetrations at master toilet -Protect pex at master-NOT DONE -fireblock dead space in master bath -fire block dead space in kitchen -missing hangers on ceiling joists above pantry/kitchen area -Fireblock ceiling line throughout great room, kitchen, etc-NOT DONE -cs-pf at right and left of great room windows -will check framing for permit door when installed -sold block all sheathing breaks throughout -fire block all wall space to ceiling space in basement see all furr downs and beams -seal penetrations in fire blocking right of beam at NE wall -address holes drilled in floor joist closer than 2” in diameter (right of beam NE wall) -when using Unfaced insulation for fire blocking must be packed tightly and securely -missing hangers at stairwell wall in basement -3.5” steel columns in basement where required -stud pack in bed 4 per plans -seal penetrations in R/a joist space above basement beds hall -complete bath fan install in basement bath -provide support for furr down above bed 3 -provide plans and third party inspection report for suspended slab garage
Electrical Service Inspection Passed 1/26/2023 1/26/2023 01/26/2023
Misc
Resolved
01/26/2023
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION.
Gas Service Inspection - Residential Passed 1/26/2023 1/26/2023 01/26/2023
Misc
Resolved
01/26/2023
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION.
Driveway Inspection Partial 1/27/2023 1/27/2023 01/27/2023
Misc
Corrective Action Required
01/27/2023
1-27-23 PS Forms are in place and aggregate has been compacted, ok to pour
All Rough Inspection - Residential Not Ready 1/31/2023 1/31/2023 01/31/2023
Misc
Corrective Action Required
01/25/2023
Erosion control to be in compliance before further inspections. -Address deck attached to cantilever-NOT DONE -Address deck post to beam connections-NOT DONE -fireblock dead space in master bath -fire block dead space in kitchen -missing hangers on ceiling joists above pantry/kitchen area -Fireblock ceiling line throughout great room, kitchen, etc-NOT DONE (seal gaps) -cs-pf at right and left of great room windows -will check framing for permit door when installed -sold block all sheathing breaks throughout -fire block all wall space to ceiling space in basement see all furr downs and beams -seal penetrations in fire blocking right of beam at NE wall -address holes drilled in floor joist closer than 2” in diameter (right of beam NE wall) -missing hangers at stairwell wall in basement -3.5” steel columns in basement where required -stud pack in bed 4 per plans -seal penetrations in R/a joist space above basement beds hall -complete bath fan install in basement bath -provide plans and third party inspection report for suspended slab garage
Driveway Inspection Passed 2/3/2023 2/3/2023 02/03/2023
Misc
Corrective Action Required
01/27/2023
1-27-23 PS Forms are in place and aggregate has been compacted, ok to pour 2-3-23 PS Driveway meets LS and ADA specifications
All Rough Inspection - Residential Passed 3/7/2023 3/7/2023 03/07/2023
Misc
Resolved
03/07/2023
Erosion control to be in compliance before further inspections. -Address deck attached to cantilever-NOT DONE -Address deck post to beam connections-NOT DONE -fireblock dead space in master bath -fire block dead space in kitchen -missing hangers on ceiling joists above pantry/kitchen area -Fireblock ceiling line throughout great room, kitchen, etc-NOT DONE (seal gaps) -cs-pf at right and left of great room windows -will check framing for permit door when installed -sold block all sheathing breaks throughout -fire block all wall space to ceiling space in basement see all furr downs and beams -seal penetrations in fire blocking right of beam at NE wall -address holes drilled in floor joist closer than 2” in diameter (right of beam NE wall) -missing hangers at stairwell wall in basement -3.5” steel columns in basement where required -stud pack in bed 4 per plans -seal penetrations in R/a joist space above basement beds hall -complete bath fan install in basement bath -provide plans and third party inspection report for suspended slab garage
Water Service Inspection - R Failed 6/1/2023 06/01/2023
Misc
Corrective Action Required
06/01/2023
- add gravel to meter pit - meter to be 14-18" from rim of pit. sitting at 12" now.
Sidewalk Inspection Partial 6/27/2023 6/27/2023 06/27/2023
Misc
Informational
06/27/2023
6-27-23 DP. Contractor had sw formed, aggregate compacted and cross slopes were in compliance but conditions can change. Approved to pour
Plot Plan Inspection Passed 6/30/2023 06/30/2023
Erosion Control Inspection Residential Failed 07/07/2023
DCM5 ESC INSP DENIED
Resolved
07/07/2023
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION.
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
07/07/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Occupancy Inspection - Codes Residential Failed 7/7/2023 7/7/2023 07/07/2023
Misc
Corrective Action Required
07/07/2023
7/7/23 -Not ready for occupancy inspection, list incomplete -Complete electrical in kitchen, label dedicated non gfci in garage, install non combustible attic access cover, adjust garage door to self close and latch **OK to store items in garage per conversation with contractor, DO NOT OCCUPY OR COVER INSPECTION ITEMS -RP
Water Service Inspection - R Passed 7/10/2023 07/10/2023
Misc
Resolved
07/10/2023
- add gravel to meter pit - meter to be 14-18" from rim of pit. sitting at 12" now.
Occupancy Inspection - Codes Residential Failed 7/10/2023 7/10/2023 07/10/2023
Misc
Resolved
07/10/2023
7/7/23 -Not ready for occupancy inspection, list incomplete -Complete electrical in kitchen, label dedicated non gfci in garage, install non combustible attic access cover, adjust garage door to self close and latch **OK to store items in garage per conversation with contractor, DO NOT OCCUPY OR COVER INSPECTION ITEMS -RP
Misc
Corrective Action Required
07/10/2023
DO NOT OCCUPY DO NOT MOVE FURNITURE INTO HOME - kitchen outlets in outdoor kitchen will not work and kitchen outlet breaker will continuously trip and not rest. Some kitchen outlets working others not. -fix deck post to beam connection per engineer letter. Use specified brackets -(2) 3” screws per hinge and strike plate at basement door -open junction box under stairs for light -install bath fan for under slab bathroom -install missing spindle at stairwell to basement -address pending sidewalk inspection
Occupancy Inspection - Codes Residential Ready for Temp CO 7/12/2023 7/12/2023 07/11/2023
Misc
Corrective Action Required
07/10/2023
-fix deck post to beam connection per engineered letter -address pending sidewalk inspection
Sidewalk Inspection Passed 7/13/2023 7/13/2023 07/13/2023
Misc
Informational
06/27/2023
6-27-23 DP. Contractor had sw formed, aggregate compacted and cross slopes were in compliance but conditions can change. Approved to pour 7-13-23 DP. SW was poured, cross slopes are in compliance. Passed.
Erosion Control Inspection Residential Passed 8/15/2023 08/15/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
08/15/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Occupancy Inspection - Codes Residential Full C of O 8/15/2023 8/15/2023 08/15/2023
Misc
Resolved
08/15/2023
-fix deck post to beam connection per engineered letter -address pending sidewalk inspection
Documents & Images
Date Uploaded File Type Document Name
11/19/2021 Building Permit Application
11/19/2021 Excise Tax Application
11/22/2021 Permit Codes Residential Plan Review
11/23/2021 Plot Plan APPROVED PLOT PLAN
11/23/2021 Approved Plans APPROVED DRAWINGS
11/30/2021 Permit Codes Residential Plan Review
02/22/2022 Permit DS Building Permit
02/22/2022 Receipt Receipt for transaction:2022-000918
02/22/2022 Letter INSPECTION SUMMARY
03/29/2022 Letter INSPECTION SUMMARY
03/31/2022 Letter INSPECTION SUMMARY
04/01/2022 Letter INSPECTION SUMMARY
09/28/2022 Letter Codes 180 Day Letter
12/19/2022 Letter INSPECTION SUMMARY
12/19/2022 Letter INSPECTION SUMMARY
12/19/2022 Letter INSPECTION SUMMARY
12/19/2022 Letter INSPECTION SUMMARY
01/11/2023 Letter INSPECTION SUMMARY
01/11/2023 Letter INSPECTION SUMMARY
01/20/2023 Letter INSPECTION SUMMARY
01/24/2023 Receipt Receipt for transaction:2023-000446
01/26/2023 Letter INSPECTION SUMMARY
01/26/2023 Letter INSPECTION SUMMARY
01/27/2023 Letter INSPECTION SUMMARY
01/31/2023 Letter INSPECTION SUMMARY
01/31/2023 Letter INSPECTION SUMMARY
01/31/2023 Letter INSPECTION SUMMARY
02/01/2023 suspended slab inspection
02/01/2023 Approved Plans APPROVED SUSPENDED SLAB PLANS
02/03/2023 Letter INSPECTION SUMMARY
02/28/2023 Inspection Engineering Report
03/06/2023 suspended slab inspection report
03/06/2023 Framing Engineering Report
03/07/2023 Letter INSPECTION SUMMARY
06/01/2023 Letter INSPECTION SUMMARY
06/27/2023 Letter INSPECTION SUMMARY
06/28/2023 Receipt Receipt for transaction:2023-005004
06/28/2023 104 Woodside Ridge As Graded Plot plan
06/29/2023 104 Woodside Ridge MBOE As Graded Plot plan added MBOE
06/29/2023 Plot Plan approved as graded plot plan
06/30/2023 Letter INSPECTION SUMMARY
07/07/2023 Letter INSPECTION SUMMARY
07/07/2023 Letter INSPECTION SUMMARY
07/10/2023 Letter INSPECTION SUMMARY
07/10/2023 Letter INSPECTION SUMMARY
07/13/2023 Certificate/License Codes Temporary Certificate of Occupancy
07/13/2023 Receipt Receipt for transaction:2023-005416
07/13/2023 Letter INSPECTION SUMMARY
08/04/2023 Deck Post to Beam Connection Engineering Letter
08/10/2023 Revised Deck Connection Engineering Report
08/15/2023 Letter Codes Final Certificate of Occupancy
08/15/2023 Letter Field Certificate of Occupancy
08/15/2023 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home