Permit Application Status

PRRES20215180


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20215180
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED DECK -
10/04/2021
10/11/2021
04/03/2022
05/23/2023
Locations
Contacts
WALKER CUSTOM HOMES, LLC, Address:PO BOX 3194, Phone:(913) 208-2026  
Jason walker, Address:PO Box 247, Phone:(913) 208-2026  
JASONFW1@COMCAST.NET  
R-MECH HEATING COOLING PLUMBING/RHODES HEATING COOLING PLUMBING AND ROOTER, Address:1425 AGNES AVE, Phone:(816) 920-5955  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
TRI-COUNTY PLUMBING LLC, Address:PO BOX 234, Phone:(816) 720-3222  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $600.00 $600.00 Paid 10/11/2021
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 10/11/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 10/11/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 10/11/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 10/11/2021
9110078-Valuation Fee New Single Family $1,498.66 $1,498.66 Paid 10/11/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 07/29/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 07/29/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 07/29/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 12/06/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 12/06/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 12/06/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 12/06/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 05/11/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 05/11/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 05/11/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 05/11/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 05/11/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 10/19/2021 10/19/2021 10/19/2021
Underslab Plumbing Inspection - Residential Passed 11/4/2021 11/4/2021 11/04/2021
Sewer Service Inspection - R Passed 11/11/2021 (1:30) 11/11/2021 11/11/2021
Erosion Control Inspection Residential Failed 3/25/2022 03/25/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
03/25/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -Maintain gravel filter -maintain silt fence -clean trash and debris from lot
All Rough Inspection - Residential Not Ready 3/25/2022 3/25/2022 03/25/2022
Misc
Corrective Action Required
03/25/2022
Inspection denied -no city stamped plans on site -maintain erosion control -clean trash from lot
Gas Service Inspection - Residential Failed 4/1/2022 04/01/2022
Misc
Corrective Action Required
04/01/2022
provide presure gauge with 10psi for inspecting and bond gas line before first csst connection.
Electrical Service Inspection Passed 4/1/2022 04/01/2022
All Rough Inspection - Residential Failed 4/1/2022 4/1/2022 04/01/2022
Misc
Resolved
04/01/2022
Inspection denied -no city stamped plans on site -maintain erosion control -clean trash from lot
Misc
Corrective Action Required
04/01/2022
-uncover front patio to inspect framing -collar ties 4’ OC (garage) -PFH strapping per plans -nail all intersecting wall corners 12” OC -seal top plate penetration left of garage entry -complete bath fan exhaust (entry bath) -seal bottom plate penetrations garage entry bath -stud packs per plans under lvl entry bath N wall -provide plumbing in prep kitchen for sink -fire block furr down in prep kitchen -fire block pantry wall to ceiling space behind furr down. Seal gaps -complete furr down for dwv and plumbing above kitchen -lvl header above sliding read door per plans -un cover covered patio for inspection -address header/beam connection right of slider s3.2 10 -address rear great room windows not framed to plans -seal floor penetration for cables at fireplace -seal gap for fireplace wall into furr down -missing joist hanger above master suite hall entrance also hanger missing nails -seal open end into furr down in master suite SW corner -seal bottom plate penetration master bath NE corner -address front door framing not to plans -Stud pack at 2nd floor supporting lvl plans call for 8studs -Protect Nm within 6’ of attic access 2nd floor -fire block basement stairwell wall to ceiling space -steel columns in basement to be of correct size -seal penetration in return air panning in basement -install all windows -provide pressure gauge at gas line for inspection -bond gas line before first csst connection -anchor bolts within 6” of sill plate break E basement wall -address piers poured without inspection
Water Service Inspection - R Passed 4/20/2022 (8:45) 4/20/2022 04/20/2022
Gas Service Inspection - Residential Passed 4/20/2022 4/20/2022 04/20/2022
Misc
Resolved
04/20/2022
provide presure gauge with 10psi for inspecting and bond gas line before first csst connection.
All Rough Inspection - Residential Failed 4/20/2022 4/20/2022 04/20/2022
Misc
Corrective Action Required
04/01/2022
PROVIDE COMPLETE SET OF PLANS FOR REINSPECTION Mitchell Schwarz 04/20/2022 9:34 AM -uncover front patio to inspect framing -collar ties 4’ OC (garage) -PFH strapping per plans -nail all intersecting wall corners 12” OC -seal top plate penetration left of garage entry -complete bath fan exhaust (entry bath) -seal bottom plate penetrations garage entry bath -stud packs per plans under lvl entry bath N wall -provide plumbing in prep kitchen for sink -fire block furr down in prep kitchen -fire block pantry wall to ceiling space behind furr down. Seal gaps -complete furr down for dwv and plumbing above kitchen -lvl header above sliding read door per plans -un cover covered patio for inspection -address header/beam connection right of slider s3.2 10 -address rear great room windows not framed to plans -seal floor penetration for cables at fireplace -seal gap for fireplace wall into furr down -missing joist hanger above master suite hall entrance also hanger missing nails -seal open end into furr down in master suite SW corner -seal bottom plate penetration master bath NE corner -address front door framing not to plans -Stud pack at 2nd floor supporting lvl plans call for 8studs -Protect Nm within 6’ of attic access 2nd floor -fire block basement stairwell wall to ceiling space -steel columns in basement to be of correct size -seal penetration in return air panning in basement -install all windows -provide pressure gauge at gas line for inspection -bond gas line before first csst connection -anchor bolts within 6” of sill plate break E basement wall -address piers poured without inspection
Piers/Caissons Inspection - Residential Passed 4/21/2022 04/21/2022
All Rough Inspection - Residential Failed 4/21/2022 4/21/2022 04/21/2022
Misc
Corrective Action Required
04/20/2022
Okay to insulate do not cover any items still in need of inspection -uncover front patio to inspect framing -nail all intersecting wall corners 12” OC -complete bath fan exhaust (entry bath) -un cover covered patio for inspection -address rear great room windows not framed to plans UPLOAD Engineer letter for fix. Uploaded letter is not for this address -missing nails in joist hanger master suite hall entrance -address front door framing not to plans fix to engineer specifications and up load letter
Erosion Control Inspection Residential Failed 4/28/2022 04/28/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
04/28/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -Maintain gravel filter -maintain silt fence -clean trash and debris from lot
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
04/28/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. maintain silt fence and gravel filter Mitchell Schwarz 04/28/2022 8:05 AM
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
04/28/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. Mitchell Schwarz 04/28/2022 8:05 AM
All Rough Inspection - Residential Not Ready 4/28/2022 4/28/2022 04/28/2022
Misc
Corrective Action Required
04/21/2022
inspection denied -could not enter home house locked -front porch still covered -erosion control not in compliance Okay to insulate do not cover any items still in need of inspection -uncover front patio to inspect framing -nail all intersecting wall corners 12” OC -complete bath fan exhaust (entry bath) -un cover covered patio for inspection -address rear great room windows not framed to plans UPLOAD Engineer letter for fix. Uploaded letter is not for this address -missing nails in joist hanger master suite hall entrance -address front door framing not to plans fix to engineer specifications and up load letter
All Rough Inspection - Residential Passed 4/29/2022 4/29/2022 04/29/2022
Misc
Resolved
04/29/2022
Driveway Inspection Partial 6/27/2022 6/27/2022 06/27/2022
Misc
Informational
06/27/2022
On 6.27.2022 Monday I performed a driveway inspection and pass the sub-grade to pour concrete.
Occupancy Inspection - Codes Residential Failed 7/28/2022 7/28/2022 07/28/2022
Misc
Corrective Action Required
07/28/2022
-address pending driveway inspection -pay all outstanding fees -final grade and sod -Splash blocks and sump pump discharge to extend 36” from foundation -guard rail at front stoop where required by code -obtain lawn irrigation permit -label all non GFCI outlets in unfinished spaces -security screws at garage side door -garage entry door to be self closing and latching -outlets in kitchen pantry to be GFCI protected -secondary locking devices at rear deck slider -shower glass to be tempered -complete stairs for inspection -address damaged floor return in basement for great room above -set screw sheared off at water anti syphon device -address damaged wiring at A/c unit -secure A/c whip within 12” of disconnect -complete deck for inspection -seal all exterior penetrations -properly illuminate address (missing light fixture)
Driveway Inspection Passed 7/29/2022 07/29/2022
Misc
Informational
06/27/2022
On 6.27.2022 Monday I performed a driveway inspection and pass the sub-grade to pour concrete. 7.29.2022 Driveway appears to be in compliance
Occupancy Inspection - Codes Residential Ready for Temp CO 7/29/2022 7/29/2022 07/29/2022
Misc
Corrective Action Required
07/28/2022
TCO UNTIL 8/29/22 -pay all outstanding fees -final grade and sod -Splash blocks and sump pump discharge to extend 36” from foundation -guard rail at front stoop where required by code -obtain lawn irrigation permit -address damaged wiring at A/c unit -secure A/c whip within 12” of disconnect -2. 1/2” through bolts at each deck post to beam connection -seal all exterior penetrations
Occupancy Inspection - Codes Residential Temporary C of O 8/1/2022 08/01/2022
Misc
Corrective Action Required
07/29/2022
TCO UNTIL 8/29/22 -pay all outstanding fees -final grade and sod -Splash blocks and sump pump discharge to extend 36” from foundation -guard rail at front stoop where required by code -obtain lawn irrigation permit -address damaged wiring at A/c unit -secure A/c whip within 12” of disconnect -2. 1/2” through bolts at each deck post to beam connection -seal all exterior penetrations
Occupancy Inspection - Codes Residential Failed 9/19/2022 09/19/2022
Misc
Corrective Action Required
08/01/2022
TCO HAS EXPIRED SUBMIT TCO EXTENSION REQUIEST TCO UNTIL 8/29/22 -pay all outstanding fees -final grade and sod -Splash blocks and sump pump discharge to extend 36” from foundation -guard rail at front stoop where required by code -obtain lawn irrigation permit -address damaged wiring at A/c unit -secure A/c whip within 12” of disconnect -2. 1/2” through bolts at each deck post to beam connection -seal all exterior penetrations
Occupancy Inspection - Codes Residential Failed 11/8/2022 11/08/2022
Misc
Corrective Action Required
09/19/2022
TCO HAS EXPIRED SUBMIT TCO EXTENSION REQUIEST TCO UNTIL 8/29/22 -pay all outstanding fees -final grade and sod -Splash blocks and sump pump discharge to extend 36” from foundation -guard rail at front stoop where required by code -obtain lawn irrigation permit -address damaged wiring at A/c unit -secure A/c whip within 12” of disconnect -2. 1/2” through bolts at each deck post to beam connection -seal all exterior penetrations
Misc
Corrective Action Required
11/08/2022
spoke with Ryan with walker homes who is going to be submitting and extension request and ensuring items are taken care of. Mitchell Schwarz 11/08/2022 2:45 PM
Erosion Control Inspection Residential Passed 12/14/2022 12/14/2022
DCM3 ESC REQUIRED 2 DAY
Resolved
12/14/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. maintain silt fence and gravel filter Mitchell Schwarz 04/28/2022 8:05 AM
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
12/14/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. Mitchell Schwarz 04/28/2022 8:05 AM
Occupancy Inspection - Codes Residential Ready for Temp CO 12/14/2022 12/14/2022 12/14/2022
Misc
Corrective Action Required
11/08/2022
-address siding from ground -obtain issued lawn irrigation permit -2. 1/2” through bolts at each deck post to beam connection -bring water meter to grade (maintain 14"-18" from meter top to well lid)
Misc
Corrective Action Required
11/08/2022
spoke with Ryan with walker homes who is going to be submitting and extension request and ensuring items are taken care of. Mitchell Schwarz 11/08/2022 2:45 PM
Plot Plan Inspection Passed 12/14/2022 12/14/2022
Occupancy Inspection - Codes Residential Failed 5/11/2023 5/11/2023 05/11/2023
Misc
Corrective Action Required
12/14/2022
-obtain issued lawn irrigation permit -2. 1/2” through bolts at each deck post to beam connection
Misc
Resolved
05/11/2023
spoke with Ryan with walker homes who is going to be submitting and extension request and ensuring items are taken care of. Mitchell Schwarz 11/08/2022 2:45 PM
Occupancy Inspection - Codes Residential Full C of O 5/23/2023 5/23/2023 05/23/2023
Misc
Resolved
05/23/2023
-obtain issued lawn irrigation permit -2. 1/2” through bolts at each deck post to beam connection
Documents & Images
Date Uploaded File Type Document Name
10/05/2021 2020 Wheatfield Ct City Permit application
10/05/2021 Permit Codes Residential Plan Review
10/06/2021 Approved Plans approved plans
10/08/2021 Plot Plan APPROVED PLOT PLAN
10/08/2021 Permit Codes Residential Plan Review
10/11/2021 Permit DS Building Permit
10/11/2021 Receipt Receipt for transaction:2021-007886
10/19/2021 Letter INSPECTION SUMMARY
11/04/2021 Letter Codes Residential Plan Review
11/04/2021 Letter INSPECTION SUMMARY
11/11/2021 Letter INSPECTION SUMMARY
03/25/2022 Letter INSPECTION SUMMARY
03/25/2022 Letter INSPECTION SUMMARY
04/01/2022 Letter INSPECTION SUMMARY
04/01/2022 Letter INSPECTION SUMMARY
04/01/2022 Letter INSPECTION SUMMARY
04/07/2022 1913 NE Catalina Ave - Structural Letter (October 9, 2021)
04/11/2022 Final_2022_03_28_DPIer_LSMO_Pat Cochran Concrete
04/12/2022 Final_2022_03_28_DPIer_LSMO_Pat Cochran Concrete
04/20/2022 Letter INSPECTION SUMMARY
04/20/2022 Letter INSPECTION SUMMARY
04/20/2022 Letter INSPECTION SUMMARY
04/21/2022 com_google_android_apps_photos_Image(2)
04/21/2022 Letter INSPECTION SUMMARY
04/21/2022 Letter INSPECTION SUMMARY
04/28/2022 Letter INSPECTION SUMMARY
04/28/2022 Letter INSPECTION SUMMARY
04/29/2022 Letter INSPECTION SUMMARY
06/27/2022 Letter INSPECTION SUMMARY
07/28/2022 Letter INSPECTION SUMMARY
07/29/2022 Letter INSPECTION SUMMARY
07/29/2022 Receipt Receipt for transaction:2022-006248
08/01/2022 Letter Codes Temporary Certificate of Occupancy
08/02/2022 Letter INSPECTION SUMMARY
09/19/2022 Letter INSPECTION SUMMARY
09/19/2022 Letter Codes 10 Day Letter
12/05/2022 Letter INSPECTION SUMMARY
12/06/2022 Certificate/License Codes Temporary Certificate of Occupancy
12/06/2022 Certificate/License Codes Temporary Certificate of Occupancy
12/06/2022 Certificate/License Codes Temporary Certificate of Occupancy
12/06/2022 Certificate/License Codes Temporary Certificate of Occupancy
12/06/2022 Receipt Receipt for transaction:2022-009302
12/13/2022 TCO extension form
12/14/2022 Letter INSPECTION SUMMARY
02/01/2023 Letter INSPECTION SUMMARY
03/01/2023 Letter Codes 10 Day Letter
05/11/2023 Certificate/License Codes Temporary Certificate of Occupancy
05/11/2023 Certificate/License Codes Temporary Certificate of Occupancy
05/11/2023 Certificate/License Codes Temporary Certificate of Occupancy
05/11/2023 Certificate/License Codes Temporary Certificate of Occupancy
05/11/2023 Certificate/License Codes Temporary Certificate of Occupancy
05/11/2023 Receipt Receipt for transaction:2023-003103
05/11/2023 Letter INSPECTION SUMMARY
05/23/2023 Letter Field Certificate of Occupancy
05/23/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home