Summary
PRRES20214095
Building Permit - Residential
Certificate of Occupancy
SILVERSTONE DEVELOPMENT LLC
NEW SINGLE FAMILY
NEW HOUSE. FINISHED WALKOUT BASEMENT. COVERED DECK. STOP WORK ORDER generated on 08/19/2021 12:00 AM by username 'Nick Lightner'. STOP WORK ORDER removed on 08/25/2021 12:00 AM by username 'Nick Lightner'.
08/06/2021
08/17/2021
02/07/2022
02/21/2023
Locations
Contacts
NICK ZVACEK CONSTRUCTION LLC, Address:1009 INDUSTRIAL DR, Phone:(816) 213-7204  
SILVERSTONE DEVELOPMENT LLC, Address:PO BOX 346  
Nick Zvacek, Address:1009 Industrial Drive, Phone:(816) 325-3440  
JEFF.BOEHM@ZVACEKCONSTRUCTION.COM  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
COMFORT SYSTEMS HTG/CLG, Address:17232 BEL-RAY PL, Phone:(816) 322-1013  
CENTURY PLUMBING, Address:14001 CENTURY LN, Phone:(816) 765-6066  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 08/17/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 08/17/2021
8331507-Sewer Connection Fee $600.00 $600.00 Paid 08/17/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 08/17/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 08/17/2021
9110078-Valuation Fee New Single Family $1,399.35 $1,399.35 Paid 08/17/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 02/15/2023
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 02/15/2023
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 02/15/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Failed - Stop Work 8/19/2021 8/19/2021 08/19/2021
Misc
Corrective Action Required
08/19/2021
8/19/21 NL - Silt fence needs to be installed around the whole property. Photo attached. Due to the basin is close to this property and the erosion is half installed I am shutting down this lot for future inspections till silt fence protects the property and the basin won't take in any silt.
Erosion Control Inspection Residential Passed 8/25/2021 8/25/2021 08/25/2021
Misc
Corrective Action Required
08/19/2021
8/19/21 NL - Silt fence needs to be installed around the whole property. Photo attached. Due to the basin is close to this property and the erosion is half installed I am shutting down this lot for future inspections till silt fence protects the property and the basin won't take in any silt.
Misc
Informational
08/25/2021
8/25/21 15:28 - Erosion fence is installed around the property, lifting stop work order.
Sewer Service Inspection - R Passed 8/26/2021 (1:00) 8/26/2021 08/26/2021
Water Service Inspection - R Partial 8/26/2021 08/26/2021
Water Service Inspection - R Passed 8/27/2021 (9:30) 8/27/2021 08/27/2021
Underslab Plumbing Inspection - Residential Passed 8/31/2021 8/31/2021 08/31/2021
Footing Inspection - Residential Passed 08/31/2021
Informational
08/31/2021
FOOTING APPROVED BY ENGINEER
All Rough Inspection - Residential Failed 12/22/2021 12/22/2021
Misc
Corrective Action Required
12/22/2021
-Provide flashings above horizontal trims -Nail siding to studs and sill plates per code -Support ridge above front bedroom -Install hangers for ceiling beams above kitchen island -Strap exterior and interior bearing wall top plates where bored more than 50% -Nail stud shoes at pantry -Protect all wiring running across studs and joists where within 6 ft of attic access Install exterior door -Provide lvl header per plan above slide doors -Fb excessive gap at back wall of fireplace space; Fb floor at trap; Fb dead space at master bath; Fb wall around master shower -Nail hanger above stair top landing at mud -Bath fan 3” duct exceed limit. Switch to 4” flex duct. No longer than 14 ft -Provide R-13 at garage/closet return air wall -Complete return air above laundry area -Install window in garage -Anchor garage sill plates per code -Install 2”x2” washers for garage PFH walls; install tension straps; install 16d nails at 2x4 plate to lvl header **INSPECTION TERMINATED. NOT READY FOR INSPECTION. TOO MANY DEFICIENCIES. HAVE EVERYONE COME AND CHECK ALL THEIR WORKS. THE ABOVE LIST IS NOT A COMPLETE LIST
Electrical Service Inspection Passed 12/22/2021 12/22/2021 12/22/2021
Gas Service Inspection - Residential Passed 12/22/2021 12/22/2021 12/22/2021
All Rough Inspection - Residential Failed 1/7/2022 1/7/2022 01/07/2022
Misc
Corrective Action Required
12/22/2021
-Provide flashings above horizontal trims -Nail siding to sill plate near AC and to studs at step flashings -Support ridge above front bedroom -Install hangers for ceiling beams above kitchen island -Strap exterior and interior bearing wall top plates where bored more than 50% -Nail stud shoes at pantry -Protect all wiring running across studs and joists where within 6 ft of attic access -Install exterior door -Provide double 12” lvl header per plan above slide doors -Fb dead space at master bath; Fb wall around master shower -Provide 4-stud support for lvl beam at master bath exterior wall; solid block underneath lvl beam point load to I beam below -Nail hanger above stair top landing at mud -Bath fan 3” duct exceed limit. Switch to 4” flex duct. No longer than 14 ft -Provide R-13 at garage/closet return air wall -Complete return air above laundry area; also pan off parallel electrical wiring within return air space -Install 2”x2” washers for garage PFH walls; install 16d nails at 2x4 plate to lvl header -Fb 2nd fl duct chase from roof; -Block off return air space from the rest of the stud space not used for return air on 2nd fl -Anchor basement sill plates per code, including at foundation wall -Bath fan duct shall not exceed 14 ft. Switch to 4” hard pipe -Fb basement wall space from all soffits and fur down ceiling space -Support DVW above basement bedroom at max 4 ft interval -Protect plumbing at basement bedroom closet; at bathroom ; wet bar -Move the lights and smoke to ceiling level -Vent bath fan -Pan off return air space from fur down ceiling space -Master shower S-trap not allowed -Seal return air space above wet bar -Fb rear basement wall space vertically at ten ft or less interval -Toe nail all joists to top plates -Blockings at cantilevered joists -Lag deck ledger board to rim -Center steel column near stair wall to near middle of pad **DO NOT INSULATE. **MUST CORRECT ALL DEFICIENCIES AT NEXT INSPECTION. REINSPECTION FEE WILL BE ASSESSED FOR EACH FAILED INSPECTION
All Rough Inspection - Residential Not Ready 1/18/2022 1/18/2022 01/18/2022
Misc
Corrective Action Required
01/07/2022
-Provide flashings above horizontal trims -Nail siding to sill plate near AC and to studs at step flashings **not done -Install hangers for ceiling beams above kitchen island **nail hangers -Strap exterior and interior bearing wall top plates where bored more than 50% **2nd floor not done -Nail stud shoes at pantry -Protect all wiring running across studs and joists where within 6 ft of attic access **main fl attic access -Install exterior door per security code -Fb dead space at master bath; Fb wall around master shower **not done -Provide 4-stud support for lvl beam at master bath exterior wall; solid block underneath lvl beam point load to I beam below **reinstall electrical wiring; solid block under lvl beam point load to I beam below -Complete return air above laundry area; also pan off parallel electrical wiring within return air space **if you are not doing the return air, then Fb the openings at bottom wall plate -Install 2”x2” washers for garage PFH walls; install 16d nails at 2x4 plate to lvl header -Fb 2nd fl duct chase from roof **Fb gap -Block off return air space from the rest of the stud space not used for return air on 2nd fl -Anchor basement sill plates per code, including at foundation wall **not done -Fb basement wall space from all soffits and fur down ceiling space **fb at gaps -Move the lights and smoke to ceiling level **secure wiring within 12” of boxes in closet; not done ousted basement bedroom -Fb rear basement wall space vertically at ten ft or less interval **fb top gap -Blockings at cantilevered joists -Lag deck ledger board to rim **OK TO INSULATE. **1/18/22-NOT READY FEE ASSESSED
All Rough Inspection - Residential Not Ready 1/26/2022 1/26/2022 01/26/2022
Misc
Corrective Action Required
01/18/2022
-Provide flashings above horizontal trims **not done -Install hangers for ceiling beams above kitchen island **nail hangers -Strap exterior and interior bearing wall top plates where bored more than 50% **2nd floor not done -Nail stud shoes at pantry -Protect all wiring running across studs and joists where within 6 ft of attic access **main fl attic access -Fb dead space at master bath; Fb wall around master shower **not done -Provide 4-stud support for lvl beam at master bath exterior wall; solid block underneath lvl beam point load to I beam below **reinstall electrical wiring; solid block under lvl beam point load to I beam below -Complete return air above laundry area; also pan off parallel electrical wiring within return air space **if you are not doing the return air, then Fb the openings at bottom wall plate -Install 2”x2” washers for garage PFH walls; install 16d nails at 2x4 plate to lvl header -Fb 2nd fl duct chase from roof **Fb gap -Block off return air space from the rest of the stud space not used for return air on 2nd fl -Anchor basement sill plates per code, including at foundation wall **not done -Fb basement wall space from all soffits and fur down ceiling space **fb at gaps -Move the lights and smoke to ceiling level **secure wiring within 12” of boxes in closet; not done ousted basement bedroom -Fb rear basement wall space vertically at ten ft or less interval **fb top gap -Blockings at cantilevered joists -Lag deck ledger board to rim -addendum: you need to reroute the electrical wiring to inside wall space at rear great room wall **OK TO INSULATE. **1/18/22-NOT READY FEE ASSESSED **1/26/22-NOT READY FEE ASSESSED
All Rough Inspection - Residential Not Ready 2/9/2022 2/9/2022 02/09/2022
Misc
Corrective Action Required
01/26/2022
-Provide flashings above horizontal trims **not done -Fb dead space at master bath; Fb wall around master shower **not done -Provide 4-stud support for lvl beam at master bath exterior wall; solid block underneath lvl beam point load to I beam below **solid block under lvl beam point load to I beam below. You must move the ducting out of the way and solid block underneath the point load -Fb basement wall space from all soffits and fur down ceiling space **Look inside the basement bedroom. Fb the wall space from fur down space at I beam and at closet -Blockings at cantilevered joists -Lag deck ledger board to rim **1/18/22-NOT READY FEE ASSESSED **1/26/22-NOT READY FEE ASSESSED **2/9/22-NOT READY FEE ASSESSED
All Rough Inspection - Residential Failed 2/15/2022 02/15/2022
Misc
Corrective Action Required
02/09/2022
-Provide 4-stud support for lvl beam at master bath exterior wall; solid block underneath lvl beam point load to I beam below **solid block under lvl beam point load to I beam below. You must move the ducting out of the way and solid block underneath the point load **1/18/22-NOT READY FEE ASSESSED **1/26/22-NOT READY FEE ASSESSED **2/9/22-NOT READY FEE ASSESSED **2/15/22-I CANNOT COMMUNICATE WITH THE ON SITE FRAMER TO CORRECT THE ABOVE.
All Rough Inspection - Residential Passed 2/22/2022 2/22/2022 02/22/2022
Misc
Resolved
02/22/2022
-Provide 4-stud support for lvl beam at master bath exterior wall; solid block underneath lvl beam point load to I beam below **solid block under lvl beam point load to I beam below. You must move the ducting out of the way and solid block underneath the point load **1/18/22-NOT READY FEE ASSESSED **1/26/22-NOT READY FEE ASSESSED **2/9/22-NOT READY FEE ASSESSED **2/15/22-I CANNOT COMMUNICATE WITH THE ON SITE FRAMER TO CORRECT THE ABOVE.
Erosion Control Inspection Residential Failed 6/15/2022 06/15/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
06/15/2022
DEFICIENT EROSION CONTROL INSTALLATION ALONG THE BASIN. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Piers/Caissons Inspection - Residential Passed 6/15/2022 6/15/2022 06/15/2022
Driveway Inspection Partial 6/15/2022 6/15/2022 06/15/2022
Misc
Informational
06/15/2022
6-15-22 AN form are in place and aggregate is present and compacted
Driveway Inspection Partial 6/17/2022 6/17/2022 06/20/2022
Misc
Informational
06/15/2022
6-15-22 AN form are in place and aggregate is present and compacted
Misc
Informational
06/20/2022
6-20-22 AN driveway looks good and has expansion joints at curb and right of way Meets Ada spec
Driveway Inspection Passed 06/20/2022
Misc
Informational
06/20/2022
6-15-22 AN form are in place and aggregate is present and compacted
Misc
Informational
06/20/2022
6-20-22 AN driveway looks good and has expansion joints at curb and right of way Meets Ada spec
Sidewalk Inspection Partial 2/13/2023 2/13/2023 06/20/2022
Misc
Corrective Action Required
06/20/2022
6-20-22 AN. To the right of the drive form are in place and aggregate in place and compacted
Plot Plan Inspection Passed 9/1/2022 09/01/2022
Erosion Control Inspection Residential Passed 01/20/2023
DCM2 ESC DEFICIENT INSTALLATION
Resolved
01/20/2023
DEFICIENT EROSION CONTROL INSTALLATION ALONG THE BASIN. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Occupancy Inspection - Codes Residential Failed 2/8/2023 2/8/2023 02/08/2023
Misc
Corrective Action Required
02/08/2023
**TCO CANNOT BE ISSUED UNTIL OTHER EXPIRED TCO PERMITS ARE CLOSED -Sidewalk not approved on record -Three not ready fees have not been paid -Seal exterior wall penetrations ; seal above meter, AC disconnect -Install tamper-proof caps at AC valves -Provide sewer tracer wire port at grade -Install splash blocks -Fix foundation drain tile to daylight -Attach deck beam to each post with two 1/2” through bolts or equivalent; lag ledger board every 16” -Provide 5/8” GB under garage boxed out wall; Fb from basement -Provide receptacle at fireplace cabinet wall space per code -Stair sconce light protruding more than 4” from wall; or move light above 6’8” above stair -Remove all foundation wall ties -Complete water heater electrical -Fb floor penetration under master bathroom tub -Install sump pump cover
Sidewalk Inspection Partial 2/13/2023 2/13/2023 02/13/2023
Misc
Corrective Action Required
06/20/2022
6-20-22 AN. To the right of the drive form are in place and aggregate in place and compacted 2-13-23 AN. Aggregate is poured and forms are placed, approved to pour
Occupancy Inspection - Codes Residential Failed 2/17/2023 2/17/2023 02/17/2023
Misc
Corrective Action Required
02/08/2023
**TCO CANNOT BE ISSUED UNTIL OTHER EXPIRED TCO PERMITS ARE CLOSED -Sidewalk not approved on record -Three not ready fees have not been paid -Attach deck beam to each post with two 1/2” through bolts or equivalent **install washers
Sidewalk Inspection Passed 2/17/2023 2/17/2023 02/17/2023
Misc
Corrective Action Required
02/13/2023
6-20-22 AN. To the right of the drive form are in place and aggregate in place and compacted 2-13-23 AN. Aggregate is poured and forms are placed, approved to pour 2-17-23 PS Sidewalk meets LS and ADA specifications
Occupancy Inspection - Codes Residential Failed 2/21/2023 2/21/2023 02/21/2023
Misc
Corrective Action Required
02/17/2023
**TCO CANNOT BE ISSUED UNTIL OTHER EXPIRED TCO PERMITS ARE CLOSED
Occupancy Inspection - Codes Residential Full C of O 2/21/2023 02/21/2023
Misc
Resolved
02/21/2023
Documents & Images
Date Uploaded File Type Document Name
08/06/2021 Lot 130 Residental Permit Application_1
08/06/2021 Lot 130 License_Tax_Application
08/11/2021 Permit Codes Residential Plan Review
08/13/2021 Plot Plan APPROVED PLOT PLAN
08/13/2021 Permit Codes Residential Plan Review
08/17/2021 M L Crose 4813 NE Freehold Ct LSMO Monticello Lot 130 NZC Permit 2021-4095 3rd Party Footing Inspection Report 8-16-21
08/17/2021 Permit DS Building Permit
08/17/2021 Receipt Receipt for transaction: 2021-006594
08/19/2021 Letter Stop Work Order
08/25/2021 Letter INSPECTION SUMMARY
08/25/2021 Letter INSPECTION SUMMARY
08/26/2021 Letter INSPECTION SUMMARY
08/26/2021 Letter INSPECTION SUMMARY
08/27/2021 Letter INSPECTION SUMMARY
08/31/2021 Letter INSPECTION SUMMARY
08/31/2021 Letter INSPECTION SUMMARY
09/30/2021 Lot 130 Revised Plans stamped 9_30_21
09/30/2021 Approved Plans APPROVED DRAWINGS
12/22/2021 Letter INSPECTION SUMMARY
12/22/2021 Letter INSPECTION SUMMARY
12/22/2021 Letter INSPECTION SUMMARY
01/07/2022 Letter INSPECTION SUMMARY
01/18/2022 Letter INSPECTION SUMMARY
01/26/2022 Letter INSPECTION SUMMARY
02/09/2022 Letter INSPECTION SUMMARY
02/15/2022 Letter INSPECTION SUMMARY
02/22/2022 Letter INSPECTION SUMMARY
06/15/2022 Letter INSPECTION SUMMARY
06/15/2022 Letter INSPECTION SUMMARY
06/15/2022 Letter INSPECTION SUMMARY
06/20/2022 Letter INSPECTION SUMMARY
06/20/2022 Letter INSPECTION SUMMARY
06/20/2022 Letter INSPECTION SUMMARY
08/31/2022 Plot Plan APPROVED AS BUILT PLOT PLAN
09/01/2022 Letter INSPECTION SUMMARY
01/20/2023 Letter INSPECTION SUMMARY
02/08/2023 Letter INSPECTION SUMMARY
02/08/2023 Lot 130 As-Built 2022-08-31
02/13/2023 Letter INSPECTION SUMMARY
02/15/2023 Receipt Receipt for transaction:2023-000880
02/17/2023 Letter INSPECTION SUMMARY
02/17/2023 Letter INSPECTION SUMMARY
02/21/2023 Letter INSPECTION SUMMARY
02/21/2023 Letter Codes Final Certificate of Occupancy
02/21/2023 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home