Permit Application Status

PRRES20214081


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20214081
Building Permit - Residential
Certificate of Occupancy
NEW DUPLEX
NEW DUPLEX - ROOF TRUSSES - FINISHED BASEMENT FOR 2009 SW OSAGE DR ONLY - UNCOVERED DECK
08/05/2021
08/17/2021
08/12/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for New Duplex $1,510.96 $1,510.96 Paid 08/17/2021
8331507-Sewer Connection Fee $720.00 $720.00 Paid 08/17/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 08/17/2021
7232302-Residential Excise Tax Fee $2,154.24 $2,154.24 Paid 08/17/2021
8331401-Water Tap Fee $7,310.00 $7,310.00 Paid 08/17/2021
8350015-Water Meter Fee $958.48 $958.48 Paid 08/17/2021
8331504-EFHB Middle Big Creek, Full $803.52 $803.52 Paid 10/22/2021
9110078-Valuation Fee for New Duplex $36.60 $36.60 Paid 05/24/2022
$1,547.56
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 05/24/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 05/24/2022
9110080-3rd and Subsequent Inspection Fee (Per Hour) $50.00 $50.00 Paid 06/28/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 08/03/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 9/30/2021 9/30/2021 09/30/2021
Misc
Informational
09/30/2021
APPROVED PER DAVID P AINSWORTH 9/16/21
Underslab Plumbing Inspection - Residential Passed 10/7/2021 10/7/2021 10/07/2021
Misc
Informational
10/07/2021
2011 AND 2009 OK
Sewer Service Inspection - R Partial 2/16/2022 (11:00) 2/16/2022 02/16/2022
Misc
Informational
02/16/2022
2009 OK
Sewer Service Inspection - R Passed 2/22/2022 (8:15) 2/22/2022 02/22/2022
Misc
Informational
02/16/2022
2009,2011 OK
Water Service Inspection - R Passed 3/3/2022 (10:30) 3/3/2022 03/03/2022
Misc
Informational
03/03/2022
Units A and B complete
All Rough Inspection - Residential Failed 5/11/2022 5/11/2022 05/11/2022
Misc
Corrective Action Required
05/11/2022
UNIT 2009 Provide engineers report on top plates, rear wall of house . Missing for top plate for headers. And no continuous top plates at corner. Header toe nailed into king stud. Over Notched joists basement No king stud bedroom window Missing “C channel at fire rock roof deck Address damaged fire rock Fire rock not seated in H track No vents allowed in first 4’ of firewall at fire rated plywood Nail protection plates all NM 1/4” or less from end of stud (4) 2x4 stud packs all girder truss bearing ends per plans Provide 30” vertical clearance at attic access Fire rated partition required at basement foundation rear corner per plan Install gas lines Address dbl rim bored for electrical above basement sliding glass door, rim not touching top plate Nail all exterior sheathing per plans Have engineer address CS-PF portal bracing at basement window per plans, dbl rim 2x10 rim installed Label meter can and disconnects UNIT 2011 Provide engineers report on top plates, rear wall of house . Missing for top plate for headers. And no continuous top plates at corner. Header toe nailed into king stud. Over Notched joists basement No king stud bedroom window Missing “C channel at fire rock roof deck Address damaged fire rock Fire rock not seated in H track No vents allowed in first 4’ of firewall at fire rated plywood Nail protection plates all NM 1/4” or less from end of stud (4) 2x4 stud packs all girder truss bearing ends per plans Provide 30” vertical clearance at attic access Fire rated partition required at basement foundation rear corner per plane Install gas lines Address dbl rim bored for electrical above basement sliding glass door, rim not touching top plate Nail all exterior sheathing per plans Have engineer address CS-PF portal bracing at basement window per plans, dbl rim 2x10 rim installed Label meter can and disconnects
Electrical Service Inspection Failed 5/11/2022 5/11/2022 05/11/2022
Misc
Corrective Action Required
05/11/2022
LABEL METER CANS AND DISCONNECTS WITH ADDRESS
Gas Service Inspection - Residential Failed 5/11/2022 5/11/2022 05/11/2022
Misc
Corrective Action Required
05/11/2022
INSTALL ALL GAS LINES
Rated Assembly Inspection Failed 5/11/2022 5/11/2022 05/11/2022
Misc
Corrective Action Required
05/11/2022
Missing “C channel at fire rock roof deck Address damaged fire rock Fire rock not seated in H track No vents allowed in first 4’ of firewall at fire rated plywood Fire rated partition required at basement foundation rear corner per plan
Erosion Control Inspection Residential Partial 5/11/2022 05/11/2022
All Rough Inspection - Residential Not Ready 5/16/2022 5/16/2022 05/16/2022
Misc
Corrective Action Required
05/11/2022
NOT READY- COMPLETE ALL ITEMS ON ENGINEERED LETTERS BEFORE RE SCHEDULING UNIT 2009 Provide engineers report on top plates, rear wall of house . Missing for top plate for headers. And no continuous top plates at corner. Header toe nailed into king stud. Over Notched joists basement No king stud bedroom window Missing “C channel at fire rock roof deck Address damaged fire rock Fire rock not seated in H track No vents allowed in first 4’ of firewall at fire rated plywood Nail protection plates all NM 1/4” or less from end of stud (4) 2x4 stud packs all girder truss bearing ends per plans Provide 30” vertical clearance at attic access Fire rated partition required at basement foundation rear corner per plan Install gas lines Address dbl rim bored for electrical above basement sliding glass door, rim not touching top plate Nail all exterior sheathing per plans Have engineer address CS-PF portal bracing at basement window per plans, dbl rim 2x10 rim installed Label meter can and disconnects UNIT 2011 Provide engineers report on top plates, rear wall of house . Missing for top plate for headers. And no continuous top plates at corner. Header toe nailed into king stud. Over Notched joists basement No king stud bedroom window Missing “C channel at fire rock roof deck Address damaged fire rock Fire rock not seated in H track No vents allowed in first 4’ of firewall at fire rated plywood Nail protection plates all NM 1/4” or less from end of stud (4) 2x4 stud packs all girder truss bearing ends per plans Provide 30” vertical clearance at attic access Fire rated partition required at basement foundation rear corner per plane Install gas lines Address dbl rim bored for electrical above basement sliding glass door, rim not touching top plate Nail all exterior sheathing per plans Have engineer address CS-PF portal bracing at basement window per plans, dbl rim 2x10 rim installed Label meter can and disconnects
Gas Service Inspection - Residential Passed 5/16/2022 05/16/2022
Misc
Resolved
05/16/2022
Driveway Inspection Partial 5/17/2022 5/17/2022 05/17/2022
Misc
Informational
05/17/2022
On 5.17.2022 I performed a driveway inspection and pass the sub-grade to pour concrete.
Electrical Service Inspection Failed 5/20/2022 5/20/2022 05/20/2022
Misc
Corrective Action Required
05/11/2022
LABEL METER CANS AND DISCONNECTS WITH ADDRESS
Rated Assembly Inspection Failed 5/20/2022 5/20/2022 05/20/2022
Misc
Corrective Action Required
05/11/2022
UNIT 2009 -Missing “C channel at fire rock roof deck, have engineer address repairs to UL design submitted, sheet metal faced nailed to rock -Address damaged fire rock -Fire rock not seated in H track -Fire rated partition required at basement foundation rear corner per plan, per approved UL design UNIT 2011 -Missing “C channel at fire rock roof deck,have engineer address repairs to UL design submitted, sheet metal faced nailed to rock, fire caulk painted of fire rock for repair -Address damaged fire rock -Fire rock not seated in H track -No vents allowed in first 4’ of firewall at fire rated plywood -Fire rated partition required at basement foundation rear corner per plan, per approved UL design
All Rough Inspection - Residential Not Ready 5/20/2022 5/20/2022 05/20/2022
Misc
Corrective Action Required
05/16/2022
UNIT 2009 -Missing “C channel at fire rock roof deck, have engineer address repairs to UL design submitted, sheet metal faced nailed to rock -Address damaged fire rock -Fire rock not seated in H track -Seal all top and bottom plate penetrations NM home run at foyer -Fire rated partition required at basement foundation rear corner per plan, per approved UL design ---Repair overnotched floor joists per engineer letter -Have engineer address CS-PF portal bracing at basement window per plans, dbl rim 2x10 rim installed, complete repair per engineer letter Label meter can and disconnects UNIT 2011 -Over Notched joists basement, sistered joist overnotched -Missing “C channel at fire rock roof deck,have engineer address repairs to UL design submitted, sheet metal faced nailed to rock, fire caulk painted of fire rock for repair -Address damaged fire rock -Fire rock not seated in H track -No vents allowed in first 4’ of firewall at fire rated plywood -Secure NM electrical per code master bed -Fire rated partition required at basement foundation rear corner per plan, per approved UL design -Have engineer address CS-PF portal bracing at basement window per plans, dbl rim 2x10 rim installed, repair per engineer letter Label meter can and disconnects
Erosion Control Inspection Residential Failed 05/20/2022
Misc
Corrective Action Required
05/20/2022
maintain erosion control on lot
Electrical Service Inspection Passed 5/26/2022 5/26/2022 05/26/2022
Misc
Resolved
05/26/2022
LABEL METER CANS AND DISCONNECTS WITH ADDRESS
Rated Assembly Inspection Passed 5/26/2022 5/26/2022 05/26/2022
Misc
Resolved
05/26/2022
All Rough Inspection - Residential Passed 5/26/2022 5/26/2022 05/26/2022
Misc
Resolved
05/26/2022
Erosion Control Inspection Residential Partial 5/26/2022 05/26/2022
Misc
Resolved
05/26/2022
maintain erosion control on lot
Sidewalk Inspection Partial 6/8/2022 06/08/2022
Misc
Informational
06/08/2022
On 6.8.2022 I performed a sidewalk inspection and pass the subgrade to pour concrete. City Standards and ADA requirements are met.
Driveway Inspection Passed 6/23/2022 6/23/2022 06/23/2022
Misc
Informational
05/17/2022
On 5.17.2022 I performed a driveway inspection and pass the sub-grade to pour concrete. On 6.23.2022 the driveway appears to be compliant.
Sidewalk Inspection Passed 6/23/2022 6/23/2022 06/23/2022
Misc
Informational
06/08/2022
On 6.8.2022 I performed a sidewalk inspection and pass the subgrade to pour concrete. City Standards and ADA requirements are met. On 6.23.2022 the sidewalk appears to be compliant.
Occupancy Inspection - Codes Residential Failed 6/27/2022 6/27/2022 06/27/2022
Misc
Corrective Action Required
06/27/2022
UNIT 2011 -FINAL GRADE AND SOD -CORRECT WATER METER ISSUES -PERM ADDRESS NUMBERS HOUSE -PERM ADDRESS IDENTIFICATION ON METER CAN AND DISCONNECT -PROVIDE SPINDLES BASEMENT STAIRS -PROVIDE HANDRAIL BASEMENT STAIRS -MAX 25 AMP OVERCURRENT PROTECTION AC -PROVIDE HAMMER ARRESTOR DISHWASHER -GARAGE DOOR MUST BE SELF CLOSING NO INSPECTION PERFORMED ON UNIT 2009
All Rough Inspection - Residential Failed 6/28/2022 6/28/2022 06/28/2022
Misc
Corrective Action Required
06/28/2022
- REVISE PERMIT FOR CORRECT ADDRESS OF DUPLEX FOR BASEMENT FINISH ON 2009 AND NOT 2011 -FIREBLOCK VERTICAL TO HORIZONTAL AT FURRED SOFFIT ENDS
Occupancy Inspection - Codes Residential Failed 6/29/2022 6/29/2022 06/29/2022
Misc
Corrective Action Required
06/27/2022
UNIT 2011 -FINAL GRADE AND SOD -PERM ADDRESS IDENTIFICATION ON METER CAN AND DISCONNECT -PROVIDE GRAVEL BASE AT WATER METER PIT **UNIT 2011 OK FOR TCO, TCO EXPIRES 7/29/22** NO INSPECTION PERFORMED ON UNIT 2009
All Rough Inspection - Residential Passed 6/30/2022 6/30/2022 06/30/2022
Misc
Resolved
06/30/2022
Erosion Control Inspection Residential Partial 06/30/2022
Occupancy Inspection - Codes Residential Ready for Temp CO 8/2/2022 08/02/2022
Misc
Corrective Action Required
06/29/2022
UNIT 2011 -FINAL GRADE AND SOD -PERM ADDRESS IDENTIFICATION ON METER CAN AND DISCONNECT -PROVIDE GRAVEL BASE AT WATER METER PIT **UNIT 2011 OK FOR TCO, TCO EXTENSION REQ RECEIVED AND APPROVED 8/2/22** NO INSPECTION PERFORMED ON UNIT 2009
Occupancy Inspection - Codes Residential Temporary C of O 8/3/2022 08/03/2022
Misc
Corrective Action Required
08/02/2022
UNIT 2011 **UNIT 2011 OK FOR TCO, TCO EXTENSION REQ RECEIVED AND APPROVED 8/2/22** NO INSPECTION PERFORMED ON UNIT 2009
Erosion Control Inspection Residential Passed 08/11/2022
Occupancy Inspection - Codes Residential Failed 8/11/2022 8/11/2022 08/11/2022
Misc
Corrective Action Required
08/03/2022
**UNIT 2011 OK FOR TCO, TCO EXTENSION REQ RECEIVED AND APPROVED 8/2/22** NO INSPECTION PERFORMED ON UNIT 2009
Plot Plan Inspection Passed 08/12/2022
Occupancy Inspection - Codes Residential Full C of O 8/12/2022 8/12/2022 08/12/2022
Misc
Resolved
08/12/2022
UNIT 2011 **UNIT 2011 OK FOR TCO, TCO EXTENSION REQ RECEIVED AND APPROVED 8/2/22** NO INSPECTION PERFORMED ON UNIT 2009
Documents & Images
Date Uploaded File Type Document Name
08/06/2021 OS #19 - PERMIT APP
08/10/2021 Permit Codes Residential Plan Review
08/17/2021 Permit DS Building Permit
08/17/2021 Receipt Receipt for transaction:2021-006574
08/31/2021 Approved Plans APPROVED TRUSS LAYOUT
08/31/2021 Approved Plans APPROVED TRUSS PACKAGE
09/30/2021 2009 & 2011 SW Osage Dr LSMO Osage Lot 19 Clayton Properties P 2021-4081 3rd Party Footing Inspection Report 9-16-21
09/30/2021 Letter INSPECTION SUMMARY
10/07/2021 Letter INSPECTION SUMMARY
10/22/2021 Receipt Receipt for transaction: 2021-008192
02/16/2022 Letter INSPECTION SUMMARY
02/22/2022 Letter INSPECTION SUMMARY
03/03/2022 Letter INSPECTION SUMMARY
05/10/2022 19 osage letter
05/11/2022 Letter INSPECTION SUMMARY
05/11/2022 Letter INSPECTION SUMMARY
05/11/2022 Letter INSPECTION SUMMARY
05/11/2022 Letter INSPECTION SUMMARY
05/11/2022 Letter INSPECTION SUMMARY
05/16/2022 OS #19a - Scope of Work - Lower Level Finish
05/16/2022 Approved Plans Approved Basement Plan
05/16/2022 19 Osage Field Issue Letter #2
05/16/2022 Letter INSPECTION SUMMARY
05/16/2022 Letter INSPECTION SUMMARY
05/20/2022 Letter INSPECTION SUMMARY
05/20/2022 Letter INSPECTION SUMMARY
05/20/2022 Letter INSPECTION SUMMARY
05/20/2022 Letter INSPECTION SUMMARY
05/24/2022 Receipt Receipt for transaction:2022-003897
05/26/2022 Letter INSPECTION SUMMARY
05/26/2022 Letter INSPECTION SUMMARY
05/26/2022 Letter INSPECTION SUMMARY
05/26/2022 Letter INSPECTION SUMMARY
06/01/2022 Letter INSPECTION SUMMARY
06/08/2022 Letter INSPECTION SUMMARY
06/21/2022 Plot Plan APPROVED PLOT PLAN
06/27/2022 Letter INSPECTION SUMMARY
06/28/2022 Receipt Receipt for transaction:2022-005211
06/28/2022 Letter INSPECTION SUMMARY
06/29/2022 Approved Plans APPROVED PLANS
06/29/2022 Letter INSPECTION SUMMARY
06/29/2022 LOT 19 MINOR PLAT SEAL
06/30/2022 Plot Plan approved plot plan
06/30/2022 Letter INSPECTION SUMMARY
06/30/2022 Letter INSPECTION SUMMARY
07/19/2022 19 Osage Letter #3
07/21/2022 Letter INSPECTION SUMMARY
07/21/2022 Letter INSPECTION SUMMARY
08/02/2022 Letter OS 19 B Extension Request Form
08/03/2022 Receipt Receipt for transaction:2022-006330
08/03/2022 Letter Codes Temporary Certificate of Occupancy
08/11/2022 Letter INSPECTION SUMMARY
08/11/2022 Letter INSPECTION SUMMARY
08/12/2022 Letter INSPECTION SUMMARY
08/12/2022 Letter Field Certificate of Occupancy
08/12/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home