Permit Application Status

PRRES20213954


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20213954
Building Permit - Residential
Certificate of Occupancy
NEW DUPLEX
NEW DUPLEX. UNFINISHED BASEMENT. UNCOVERED DECK. UNIT "A" WALKOUT BASEMENT.
07/30/2021
09/01/2021
08/11/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
JASONH@CLOVERANDHIVE.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for New Duplex $1,689.66 $1,689.66 Paid 09/01/2021
8331507-Sewer Connection Fee $840.00 $840.00 Paid 09/01/2021
8331401-Water Tap Fee $7,310.00 $7,310.00 Paid 09/01/2021
8350015-Water Meter Fee $958.48 $958.48 Paid 09/01/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 09/01/2021
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 09/01/2021
8331504-EFHB Middle Big Creek, Full $937.44 $937.44 Paid 10/22/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 06/28/2022
9110080-3rd and Subsequent Inspection Fee (Per Hour) $100.00 $100.00 Paid 06/28/2022
9110080-3rd and Subsequent Inspection Fee (Per Hour) $50.00 $50.00 Paid 06/28/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 07/13/2022
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 08/10/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 9/30/2021 9/30/2021 09/30/2021
Misc
Informational
09/30/2021
APPROVED PER DAVID P AINSWORTH 9/16/21
Underslab Plumbing Inspection - Residential Passed 10/19/2021 10/19/2021 10/19/2021
Sewer Service Inspection - R Passed 12/7/2021 (1:00) 12/7/2021 12/07/2021
Water Service Inspection - R Passed 12/9/2021 (11:30) 12/9/2021 12/09/2021
Erosion Control Inspection Residential Failed 12/9/2021 12/9/2021 12/09/2021
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
12/09/2021
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Sewer Service Inspection - R Passed 12/13/2021 (10:00) 12/13/2021 12/13/2021
Misc
Informational
12/13/2021
2015, 2017 OK
Water Service Inspection - R Passed 12/17/2021 (11:15) 12/17/2021 12/17/2021
Misc
Corrective Action Required
12/17/2021
2015 ok
All Rough Inspection - Residential Not Ready 5/4/2022 5/4/2022 05/04/2022
Misc
Corrective Action Required
05/04/2022
INSPECTION DENIED -MAINTAIN EROSION CONTROL ON LOT, GRAVEL FILTER REQUIRED, MIN 6" LIFT ON DRIVE
Electrical Service Inspection Failed 5/4/2022 5/4/2022 05/04/2022
Misc
Corrective Action Required
05/04/2022
INSPECTION DENIED MAINTAIN EROSION CONTROL ON LOT, GRAVEL FILTER REQUIRED, MIN 6" LIFT ON DRIVE
Gas Service Inspection - Residential Failed 5/4/2022 5/4/2022 05/04/2022
Misc
Corrective Action Required
05/04/2022
INSPECTION DENIED MAINTAIN EROSION CONTROL ON LOT, GRAVEL FILTER REQUIRED, MIN 6" LIFT ON DRIVE
Erosion Control Inspection Residential Failed 5/4/2022 5/4/2022 05/04/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
05/04/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Misc
Corrective Action Required
05/04/2022
MAINTAIN EROSION CONTROL ON LOT, GRAVEL FILTER REQUIRED, MIN 6" LIFT ON DRIVE
Rated Assembly Inspection Failed 5/4/2022 5/4/2022 05/04/2022
Misc
Corrective Action Required
05/04/2022
INSPECTION DENIED
All Rough Inspection - Residential Failed 5/11/2022 5/11/2022 05/11/2022
Misc
Corrective Action Required
05/04/2022
INSPECTION DENIED AS DISCUSSED, SCHEDULE REINSPECTION AFTER WALKING FROM 2003 AND 2009 Patrick Schonfeldt 05/11/2022 2:41 PM
Erosion Control Inspection Residential Partial 5/11/2022 05/11/2022
Misc
Resolved
05/11/2022
Electrical Service Inspection Failed 5/16/2022 5/16/2022 05/16/2022
Misc
Corrective Action Required
05/04/2022
-LABEL DISCONNECTS AND METER CANS WITH ADDRESSES
Gas Service Inspection - Residential Passed 5/16/2022 5/16/2022 05/16/2022
Misc
Resolved
05/16/2022
INSPECTION DENIED MAINTAIN EROSION CONTROL ON LOT, GRAVEL FILTER REQUIRED, MIN 6" LIFT ON DRIVE
Rated Assembly Inspection Failed 5/16/2022 5/16/2022 05/16/2022
Misc
Corrective Action Required
05/04/2022
UNIT 2015: -fire rock required to be seated in H stud -repair damaged sections of fire rock above 1st floor 1/2 bath -smart siding cannot be used to repair fire rock -provide UL cert and specs for gray caulking used on firewall -seal through penetrations for firewall SE cable basement UNIT 2017: -fire rock required to be seated in H stud per plans -repair damaged sections of fire rock -provide UL cert and specs for gray caulking used on firewall
All Rough Inspection - Residential Failed 5/16/2022 5/16/2022 05/16/2022
Misc
Corrective Action Required
05/11/2022
UNIT 2015: -No city stamped truss plans on site Fireblock plumbing chase garage entry -complete air return? garage entry chase, seal all penetrations, pan off from firewall , pan off 2nd floor wall cavities, behind tub etc -seal top plate penetrations see master bed -30” vertical clearance required at attic access -protect all NM within 6’ of attic entry -provide (2) 2x4 stud pack at dbl 2x10 right side of garage per plans -provide attic access garage per plans -seal penetrations through air return basement -address over bores floor joist for DWV -LIB bracing basement per plans -loosen corner stud at SE corner between units basement to see required firewall -solid block between joists kitchen island per plans -CS-PF bracing design per plans at great room, nail exterior sheathing per plans / IRC R602.10.6.4 -fire rock required to be seated in H stud -repair damaged sections of fire rock above 1st floor 1/2 bath -smart siding cannot be used to repair fire rock -provide UL cert and specs for gray caulking used on firewall -seal through penetrations for firewall SE cable basement UNIT 2017: -No city stamped truss plans on site -seal all top plate penetrations at garage -complete air return? garage entry chase, seal all penetrations, pan off from firewall , pan off 2nd floor wall cavities, behind tub etc -30” vertical clearance required at attic access -protect all NM within 6’ of attic entry -CS-PF bracing design per plans at great room, nail exterior sheathing per plans / IRC R602.10.6.4 -attic access garage per plans -solid block between joists above garage wall -seal penetrations through air return basement -fire rock required to be seated in H stud per plans -repair damaged sections of fire rock -provide UL cert and specs for gray caulking used on firewall
Erosion Control Inspection Residential Partial 05/16/2022
Driveway Inspection Partial 5/17/2022 5/17/2022 05/17/2022
Misc
Informational
05/17/2022
On 5.17.2022 I performed a driveway inspection and pass the sub-grade to pour concrete.
Electrical Service Inspection Failed 5/23/2022 5/23/2022 05/23/2022
Misc
Corrective Action Required
05/16/2022
-LABEL DISCONNECTS AND METER CANS WITH ADDRESSES
All Rough Inspection - Residential Failed 5/23/2022 5/23/2022 05/23/2022
Misc
Corrective Action Required
05/16/2022
UNIT 2015: -No city stamped truss plans on site -Fireblock plumbing chase garage entry -Fireblock HVAC chase garage entry, fireblock between floors -protect all NM within 6’ of attic entry -address over bores floor joist for DWV, repair per engineer letter -LIB bracing basement per plans -solid block between joists kitchen island per plans -fire rock required to be seated in H stud, see master bed -fire rated plywood first 4’ of firewall -smart siding cannot be used to repair fire rock -provide UL cert and specs for gray and yellow caulking used on firewall -seal through penetrations for firewall SE cable basement UNIT 2017: -No city stamped truss plans on site -Fireblock HVAC chase garage entry between floors, 2nd floor behind tub -fireblock plumbing chase garage entry -protect all NM within 6’ of attic entry -seal penetrations through air return basement -provide UL cert and specs for gray, yellow caulking used on firewall
Rated Assembly Inspection Failed 5/23/2022 5/23/2022 05/23/2022
Misc
Corrective Action Required
05/16/2022
UNIT 2015: -fire rock required to be seated in H stud, see master bed -fire rated plywood first 4’ of firewall -smart siding cannot be used to repair fire rock -provide UL cert and specs for gray and yellow caulking used on firewall -seal through penetrations for firewall SE cable basement UNIT 2017: -seal penetrations through air return basement -provide UL cert and specs for gray, yellow caulking used on firewall
Erosion Control Inspection Residential Partial 05/23/2022
Electrical Service Inspection Passed 5/26/2022 5/26/2022 05/26/2022
Misc
Resolved
05/26/2022
-LABEL DISCONNECTS AND METER CANS WITH ADDRESSES
Erosion Control Inspection Residential Partial 5/26/2022 05/26/2022
All Rough Inspection - Residential Failed 5/26/2022 5/26/2022 05/26/2022
Misc
Corrective Action Required
05/23/2022
UNIT 2015: -LIB bracing basement per plans -Provide fasteners per truss hanger manufacturer, drywall screws not allowed -gray caulking on firewall does not meet ASTM E814, UL 1479 rating UNIT 2017: -Provide fasteners per truss hanger manufacturer, drywall screws not allowed -gray caulking on firewall does not meet ASTM E814, UL 1479 rating
Rated Assembly Inspection Failed 5/26/2022 5/26/2022 05/26/2022
Misc
Corrective Action Required
05/23/2022
UNIT 2015: -gray caulking on firewall does not meet ASTM E814, UL 1479 rating UNIT 2017: -gray caulking on firewall does not meet ASTM E814, UL 1479 rating
All Rough Inspection - Residential Passed 5/27/2022 5/27/2022 05/27/2022
Misc
Resolved
05/27/2022
Rated Assembly Inspection Passed 5/27/2022 5/27/2022 05/27/2022
Misc
Resolved
05/27/2022
Erosion Control Inspection Residential Passed 5/27/2022 05/27/2022
Sidewalk Inspection Partial 6/8/2022 06/08/2022
Misc
Informational
06/08/2022
On 6.8.2022 Wednesday I performed a sidewalk inspection and passed the sub-grade to pour concrete. City Standards and ADA requirements were met.
Water Service Inspection - R Passed 7/7/2022 07/07/2022
Occupancy Inspection - Codes Residential Failed 7/12/2022 7/12/2022 07/12/2022
Misc
Corrective Action Required
07/12/2022
-final driveway and sidewalk inspections required, contact development services to schedule -final grade and sod -splash blocks all downspout and sump pump discharge locations, min 36” discharge from foundation -provide permanent address at electric meter cans anddisconnects -provide gravel base at water meter pit UNIT 2015: -provide approved cover UFER garage, open to rim/sill plate, UFER must remain accessible -provide non combustible attic access cover laundry -basement stairs handrail needs to return to a safety terminal or newel post -hot water heater discharge line max 6” AFF -(2) 1/2” through bolts at each post/beam connection at deck -provide angle hangers at inner ply of deck beam, lag outer ply to ledger NO INSPECTION PERFORMED ON UNIT 2017
Driveway Inspection Passed 7/12/2022 7/12/2022 07/12/2022
Misc
Informational
05/17/2022
On 5.17.2022 I performed a driveway inspection and pass the sub-grade to pour concrete. 7.12.2022 the driveway appears to be in compliance.
Sidewalk Inspection Passed 7/12/2022 7/12/2022 07/12/2022
Misc
Informational
06/08/2022
On 6.8.2022 Wednesday I performed a sidewalk inspection and passed the sub-grade to pour concrete. City Standards and ADA requirements were met. 7.12.2022 sidewalk appears to be in compliance
Occupancy Inspection - Codes Residential Ready for Temp CO 7/13/2022 7/13/2022 07/13/2022
Misc
Corrective Action Required
07/12/2022
-provide as graded plot plan -uncover covered manhole -provide gravel base at water meter pit UNIT 2015 OK NO INSPECTION PERFORMED ON UNIT 2017
Occupancy Inspection - Codes Residential Temporary C of O 07/13/2022
Misc
Corrective Action Required
07/13/2022
-final grade and sod -splash blocks all downspout and sump pump discharge locations, min 36” discharge from foundation -provide permanent address at electric meter cans and disconnects -provide gravel base at water meter pit UNIT 2015 OK NO INSPECTION PERFORMED ON UNIT 2017
Occupancy Inspection - Codes Residential Not Ready 7/20/2022 7/20/2022 07/20/2022
Misc
Corrective Action Required
07/13/2022
-final grade and sod -splash blocks all downspout and sump pump discharge locations, min 36” discharge from foundation -provide permanent address at electric meter cans and disconnects -provide gravel base at water meter pit UNIT 2015 OK 7/20/22 - INSPECTION DENIED, UNIT 2017 NOT READY FOR INSPECTION
Occupancy Inspection - Codes Residential Failed 8/5/2022 8/5/2022 08/05/2022
Misc
Corrective Action Required
07/20/2022
unit 2017 -provide gravel base at water meter pit -uncover man hole lid -provide as graded plot plan -tamper resistant caps at A/c unit -approved access panel for ufer ground connection in garage -deck stairs greater than 7 3/4" -deck stairs rise greater than 3/8" differance UNIT 2015 OK
Plot Plan Inspection Passed 08/11/2022
Occupancy Inspection - Codes Residential Full C of O 8/11/2022 8/11/2022 08/11/2022
Misc
Informational
08/11/2022
unit 2017 ok UNIT 2015 OK
Documents & Images
Date Uploaded File Type Document Name
07/30/2021 OS #18 - PERMIT APP
08/04/2021 Permit Codes Residential Plan Review
08/05/2021 Permit Codes Residential Plan Review
08/31/2021 Approved Plans APPROVED TRUSS LAYOUT
08/31/2021 Approved Plans APPROVED TRUSS PACKAGE
09/01/2021 Permit DS Building Permit
09/01/2021 Receipt Receipt for transaction:2021-007035
09/30/2021 2015 & 2017 SW Osage Dr LSMO Osage Lot 18 Clayton Properties P 2021-3954 3rd Party Footing Inspection Report 9-16-21
09/30/2021 Letter INSPECTION SUMMARY
10/19/2021 Letter INSPECTION SUMMARY
10/22/2021 Receipt Receipt for transaction: 2021-008192
12/07/2021 Letter INSPECTION SUMMARY
12/09/2021 Letter INSPECTION SUMMARY
12/09/2021 Letter INSPECTION SUMMARY
12/13/2021 Letter INSPECTION SUMMARY
12/17/2021 Letter INSPECTION SUMMARY
01/28/2022 Approved Plans APPROVED DRAWINGS UPDATE
05/04/2022 Letter INSPECTION SUMMARY
05/04/2022 Letter INSPECTION SUMMARY
05/04/2022 Letter INSPECTION SUMMARY
05/04/2022 Letter INSPECTION SUMMARY
05/04/2022 Letter INSPECTION SUMMARY
05/10/2022 18 osage letter
05/11/2022 Letter INSPECTION SUMMARY
05/11/2022 Letter INSPECTION SUMMARY
05/16/2022 Letter INSPECTION SUMMARY
05/16/2022 Letter INSPECTION SUMMARY
05/16/2022 Letter INSPECTION SUMMARY
05/16/2022 Letter INSPECTION SUMMARY
05/16/2022 Letter INSPECTION SUMMARY
05/19/2022 18 osage letter #2
05/23/2022 Letter INSPECTION SUMMARY
05/23/2022 Letter INSPECTION SUMMARY
05/23/2022 Letter INSPECTION SUMMARY
05/23/2022 Letter INSPECTION SUMMARY
05/26/2022 OS pt_1
05/26/2022 OS pt_2
05/26/2022 Letter INSPECTION SUMMARY
05/26/2022 Letter INSPECTION SUMMARY
05/26/2022 Letter INSPECTION SUMMARY
05/26/2022 Letter INSPECTION SUMMARY
05/27/2022 Letter INSPECTION SUMMARY
05/27/2022 Letter INSPECTION SUMMARY
05/27/2022 Letter INSPECTION SUMMARY
06/01/2022 Letter INSPECTION SUMMARY
06/08/2022 Letter INSPECTION SUMMARY
06/21/2022 Approved Plans APPROVED PLANS
06/28/2022 Receipt Receipt for transaction:2022-005213
06/29/2022 LOT 18 MINOR PLAT SEAL
06/30/2022 Plot Plan APPROVED PLOT PLAN
07/07/2022 Letter INSPECTION SUMMARY
07/12/2022 Letter INSPECTION SUMMARY
07/13/2022 Receipt Receipt for transaction:2022-005720
07/13/2022 Letter Codes Temporary Certificate of Occupancy
07/19/2022 18 Osage Letter #3
07/20/2022 Letter INSPECTION SUMMARY
07/21/2022 Letter INSPECTION SUMMARY
07/21/2022 Letter INSPECTION SUMMARY
07/21/2022 Letter INSPECTION SUMMARY
08/05/2022 Letter INSPECTION SUMMARY
08/10/2022 Receipt Receipt for transaction:2022-006562
08/10/2022 LOT 18 CITY
08/11/2022 Letter Codes Final Certificate of Occupancy
08/11/2022 Letter Field Certificate of Occupancy
08/11/2022 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home