Summary
PRRES20213805
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - UNCOVERED PATIO
07/22/2021
07/30/2021
01/19/2022
11/14/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
JOE@CLOVERANDHIVE.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 07/30/2021
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 07/30/2021
8331507-Sewer Connection Fee $450.00 $450.00 Paid 07/30/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 07/30/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 07/30/2021
9110078-Valuation Fee New Single Family $1,178.49 $1,178.49 Paid 07/30/2021
8331504-EFHB Middle Big Creek, Full $502.20 $502.20 Paid 10/22/2021
9110080-3rd and Subsequent Inspection Fee (Per Hour) $50.00 $50.00 Paid 10/28/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 10/28/2022
9110080-3rd and Subsequent Inspection Fee (Per Hour) $175.00 $175.00 Paid 10/28/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 10/6/2021 10/6/2021 10/06/2021
Misc
Informational
10/06/2021
10/1/2021 inspection done by David ainsworth
Underslab Plumbing Inspection - Residential Failed 10/21/2021 10/21/2021 10/21/2021
Misc
Corrective Action Required
10/21/2021
Inspection denied, backfill required to view plumbing.
Erosion Control Inspection Residential Failed 10/21/2021
Misc
Corrective Action Required
10/21/2021
-fix silt fence -clean up street
Underslab Plumbing Inspection - Residential Failed 11/11/2021 11/11/2021 11/11/2021
Misc
Resolved
11/11/2021
Inspection denied, backfill required to view plumbing.
Misc
Corrective Action Required
11/11/2021
Water needs pumped out to view plumbing
Underslab Plumbing Inspection - Residential Passed 11/17/2021 11/17/2021 11/17/2021
Misc
Resolved
11/17/2021
Water needs pumped out to view plumbing
Sewer Service Inspection - R Passed 11/29/2021 (8:45) 11/29/2021 11/29/2021
Erosion Control Inspection Residential Failed 11/29/2021 11/29/2021
Misc
Resolved
11/29/2021
-fix silt fence -clean up street
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
11/29/2021
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -FIX DOWNED SILT FENCE -STREET CLEAN UP
Water Service Inspection - R Passed 12/2/2021 (2:00) 12/2/2021 12/02/2021
Erosion Control Inspection Residential Failed 12/2/2021 12/2/2021 12/02/2021
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
12/02/2021
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -FIX DOWNED SILT FENCE -STREET CLEAN UP
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
12/02/2021
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Electrical Service Inspection Passed 6/7/2022 6/7/2022 06/07/2022
Gas Service Inspection - Residential Failed 6/7/2022 6/7/2022 06/07/2022
Misc
Corrective Action Required
06/07/2022
-Gas pressure 6 psi, must maintain 10 psi for test
All Rough Inspection - Residential Failed 6/7/2022 6/7/2022 06/07/2022
Misc
Corrective Action Required
06/07/2022
-fireblock HVAC/radon chase great room/garage -complete plumbing above garage entry -provide bocca protection plate at bottom plate pex kitchen fridge -provide stud shoe at exterior stud bored for DWV 1st floor powder bath -provide bocca protection plate at top plate kitchen for pex -provide structural straps all top plates bored 50% or more all interior load bearing wall and all exterior walls -toenail floor joists per code -secure all vertical DWV 2” or less at mid point -(2) 2x4 stud pack at dbl 2x10 garage wall bearing per plans -Have engineer with truss manufacturer address the D3 trusses at garage that end chords and gusset plates have been sheared down -CS-PF portal bracing design per plans at master bedroom, see detail in plans/IRC R602.10.6.4 -address master bed exterior wall top plates not lapped at corners per code
Erosion Control Inspection Residential Failed 06/07/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
12/02/2021
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Driveway Inspection Partial 6/7/2022 6/7/2022 06/07/2022
Misc
Informational
06/07/2022
Driveway is formed and ready to pour.
Driveway Inspection Passed 6/9/2022 06/09/2022
Misc
Informational
06/07/2022
Driveway is formed and ready to pour.
Misc
Informational
06/09/2022
Approach has been poured and appears to be compliant.
Sidewalk Inspection Partial 6/9/2022 6/9/2022 06/09/2022
Misc
Informational
06/09/2022
On 6.9.2022 I performed a sidewalk inspection and pass the subgrade to pour concrete.
Gas Service Inspection - Residential Passed 6/20/2022 6/20/2022 06/20/2022
Misc
Resolved
06/20/2022
All Rough Inspection - Residential Failed 6/20/2022 6/20/2022 06/20/2022
Misc
Corrective Action Required
06/07/2022
-fireblock HVAC/radon chase great room/garage, (block vertical to horizontal at furred down on garage side) -Have engineer with truss manufacturer address the D3 trusses at garage that end chords and gusset plates have been sheared down -CS-PF portal bracing design per plans at master bedroom, see detail in plans/IRC R602.10.6.4 (header PFH design per code, have engineer address)
Erosion Control Inspection Residential Partial 06/20/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
06/20/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
All Rough Inspection - Residential Not Ready 6/24/2022 6/24/2022 06/24/2022
Misc
Corrective Action Required
06/20/2022
6/24/22 - INSPECTION DENIED ADDRESS EROSION CONTROL AT FRONT OF LOT, NO EROSION CONTROL PRESENT AT FRONT OF LOT, NO ENGINEER REPORT IN PERMIT CONCERNING TRUSSES -fireblock HVAC/radon chase great room/garage, (block vertical to horizontal at furred down on garage side) -Have engineer with truss manufacturer address the D3 trusses at garage that end chords and gusset plates have been sheared down -CS-PF portal bracing design per plans at master bedroom, see detail in plans/IRC R602.10.6.4 (header PFH design per code, have engineer address)
Erosion Control Inspection Residential Failed 6/24/2022 6/24/2022 06/24/2022
Misc
Corrective Action Required
06/24/2022
ADDRESS EROSION CONTROL AT FRONT OF LOT, NO EROSION CONTROL PRESENT AT FRONT OF LOT
All Rough Inspection - Residential Failed 7/7/2022 7/7/2022 07/07/2022
Misc
Corrective Action Required
06/24/2022
-fireblock HVAC/radon chase great room/garage, (block vertical to horizontal at furred down on garage side) -CS-PF portal bracing design per plans at master bedroom, see detail in plans/IRC R602.10.6.4 (header PFH design per code, have engineer address) . Still no letter submitted. Provide letter from EOR that the cspf has been inspected and accepted the installation. This is not typical design for cspf.
All Rough Inspection - Residential Failed 7/8/2022 7/8/2022 07/08/2022
Misc
Corrective Action Required
07/07/2022
-fireblock HVAC/radon chase great room/garage, (block vertical to horizontal at furred down on garage side) -CS-PF portal bracing design per plans at master bedroom, see detail in plans/IRC R602.10.6.4 (header PFH design per code, have engineer address) . Still no letter submitted. Provide letter from EOR that the cspf has been inspected and accepted the installation. This is not typical design for cspf.
Misc
Corrective Action Required
07/08/2022
letter does not explain the situation. the header is above the plate line, in the gable. have the engineer state header instaled above the plate line. need to be more commentary to understand letter and how hte straps work or the CSPF additionally the sheathing method would be different above the plate line. no inspeciton was performed.
All Rough Inspection - Residential Failed 7/19/2022 7/19/2022 07/19/2022
Misc
Corrective Action Required
07/08/2022
7/19/22 - AS STATED PROVIDE LETTER FROM ENGINEER ON NON CONVENTIAL CS-PF FRAMING ON SITE. LETTER IN PERMIT DOES NOT ADDRESS DESIGN OR ISSUES ON SITE. OSB FACE NAILED TO INTERIOR SIDE OF WALL -CS-PF portal bracing design per plans at master bedroom, see detail in plans/IRC R602.10.6.4 (header PFH design per code, have engineer address) . Still no letter submitted. Provide letter from EOR that the cspf has been inspected and accepted the installation. This is not typical design for cspf. letter does not explain the situation. the header is above the plate line, in the gable. have the engineer state header instaled above the plate line. need to be more commentary to understand letter and how hte straps work or the CSPF additionally the sheathing method would be different above the plate line. no inspeciton was performed.
Misc
Corrective Action Required
07/25/2022
Sidewalk Inspection Passed 7/20/2022 7/20/2022 07/20/2022
Misc
Informational
06/09/2022
On 6.9.2022 I performed a sidewalk inspection and pass the subgrade to pour concrete. 7.20.2022 Sidewalk appears to be in compliance
All Rough Inspection - Residential Passed 7/21/2022 7/21/2022 07/21/2022
Misc
Resolved
07/21/2022
Erosion Control Inspection Residential Passed 11/1/2022 11/1/2022 11/01/2022
Misc
Resolved
11/01/2022
ADDRESS EROSION CONTROL AT FRONT OF LOT, NO EROSION CONTROL PRESENT AT FRONT OF LOT
Plot Plan Inspection Passed 11/1/2022 11/1/2022 11/01/2022
Occupancy Inspection - Codes Residential Failed 11/1/2022 11/1/2022 11/01/2022
Misc
Corrective Action Required
11/01/2022
-handrail at front stairs must be between 34”-38” -interconnection required of all smoke detectors -install sliding glass door hardware and secondary lock -provide hammer arrestor at dishwasher -repair rock at garage wall and garage ceiling -install ceiling light master bed -provide pressure regulator at main water line -provide anti siphon device at spigot basement, shear off set screw head after tightening -replace vegetation at rear of lot disturbed from construction
Occupancy Inspection - Codes Residential Failed 11/11/2022 11/11/2022 11/11/2022
Misc
Corrective Action Required
11/01/2022
-interconnection required of all smoke detectors - see basement smoke
Occupancy Inspection - Codes Residential Full C of O 11/14/2022 11/14/2022 11/14/2022
Misc
Resolved
11/14/2022
-interconnection required of all smoke detectors - see basement smoke
Documents & Images
Date Uploaded File Type Document Name
07/22/2021 OS #33 - PERMIT APP
07/23/2021 Permit Codes Residential Plan Review
07/23/2021 Plot Plan Approved Plot Plan
07/30/2021 Approved Plans Approved Drawings
07/30/2021 Permit Codes Residential Plan Review
07/30/2021 Permit DS Building Permit
07/30/2021 Receipt Receipt for transaction:2021-006075
08/30/2021 Approved Plans APPROVED TRUSS LAYOUT
08/31/2021 Approved Plans APPROVED TRUSS PACKAGE
10/06/2021 M L Crose 2105 SW Rutherford Dr LSMO Osage Lot 33 LSMO Clayton P 2021-3805 3rd Party Footing Inspection Report 10-1-21
10/06/2021 Letter INSPECTION SUMMARY
10/06/2021 Letter INSPECTION SUMMARY
10/21/2021 Letter INSPECTION SUMMARY
10/21/2021 Letter INSPECTION SUMMARY
10/22/2021 Receipt Receipt for transaction: 2021-008192
11/11/2021 Letter INSPECTION SUMMARY
11/17/2021 Letter INSPECTION SUMMARY
11/29/2021 Letter INSPECTION SUMMARY
11/29/2021 Letter INSPECTION SUMMARY
12/02/2021 Letter INSPECTION SUMMARY
12/02/2021 Letter INSPECTION SUMMARY
06/07/2022 Letter INSPECTION SUMMARY
06/07/2022 Letter INSPECTION SUMMARY
06/07/2022 Letter INSPECTION SUMMARY
06/07/2022 Letter INSPECTION SUMMARY
06/07/2022 Letter INSPECTION SUMMARY
06/09/2022 Letter INSPECTION SUMMARY
06/09/2022 Letter INSPECTION SUMMARY
06/09/2022 Letter INSPECTION SUMMARY
06/20/2022 Letter INSPECTION SUMMARY
06/20/2022 Letter INSPECTION SUMMARY
06/20/2022 Letter INSPECTION SUMMARY
06/24/2022 Letter INSPECTION SUMMARY
06/24/2022 Letter INSPECTION SUMMARY
06/24/2022 OS33 Truss Repair I52400685_220005
07/07/2022 Letter INSPECTION SUMMARY
07/07/2022 Engineer Report/Study ENGINEER REPORT
07/08/2022 Letter INSPECTION SUMMARY
07/19/2022 Letter INSPECTION SUMMARY
07/19/2022 33 Osage Field Issue 071822
07/21/2022 Letter INSPECTION SUMMARY
07/21/2022 Letter INSPECTION SUMMARY
10/28/2022 Receipt Receipt for transaction:2022-008580
11/01/2022 Letter INSPECTION SUMMARY
11/01/2022 Letter INSPECTION SUMMARY
11/01/2022 Letter INSPECTION SUMMARY
11/11/2022 Letter INSPECTION SUMMARY
11/14/2022 Letter Field Certificate of Occupancy
11/14/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home