Permit Application Status

PRRES20212434


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20212434
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED PATIO
05/12/2021
05/21/2021
11/09/2021
05/17/2022
Locations
Contacts
FIRST CHOICE CUSTOM HOMES LLC, Address:PO BOX 860072, Phone:(913) 449-8935  
DENNIS@FIRSTCHOICEHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ADVANCED ELECTRICAL LLC, Address:PO BOX 1573, Phone:(816) 347-8187  
BILL'S PLUMBING SERVICE LLC, Address:308 E PARK ST, Phone:(913) 829-8213  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,216.39 $1,216.39 Paid 05/21/2021
Right of Way Permit Fee $80.00 $80.00 Paid 05/21/2021
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 05/21/2021
8331504-EFHB Middle Big Creek, Full $703.08 $703.08 Paid 05/21/2021
8331507-Sewer Connection Fee $630.00 $630.00 Paid 05/21/2021
Water Tap Fee $3,581.00 $3,581.00 Paid 05/21/2021
Water Meter Fee $455.54 $455.54 Paid 05/21/2021
Not Ready Inspection Fee $50.00 $50.00 Paid 04/12/2022
3rd and Subsequent Inspection Fee (Per Hour) $150.00 $150.00 Paid 04/12/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 7/6/2021 (1:00) 7/6/2021 07/06/2021
Underslab Plumbing Inspection - Residential Failed 8/12/2021 8/12/2021 08/12/2021
Misc
Corrective Action Required
08/12/2021
CORRECT DEAD END AT DWV UNDERSLAB
Erosion Control Inspection Residential Failed 8/13/2021 08/13/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
08/13/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. **RESTORE EROSION CONTROL ALONG THE STREET, ESPECIALLY AT STORM INLET. CLEAN STREET
Underslab Plumbing Inspection - Residential Passed 8/13/2021 8/13/2021 08/13/2021
Misc
Resolved
08/13/2021
CORRECT DEAD END AT DWV UNDERSLAB
All Rough Inspection - Residential Failed 12/22/2021 12/22/2021 09/15/2021
Miscellaneous Correction
Informational
09/15/2021
-PORTAL FRAME INSPECTION 8-15-21 **OK TO COVER EXTERIOR ONLY
Rough Framing Inspection - Residential Passed 9/15/2021 9/15/2021 09/15/2021
Misc
Informational
09/15/2021
8-15-21 PORTAL FRAME INSPECTION: OK TO COVER EXTERIOR ONLY
Sewer Service Inspection - R Passed 10/6/2021 (11:15) 10/6/2021 10/06/2021
Water Service Inspection - R Passed 10/7/2021 (9:45) 10/7/2021 10/07/2021
Piers/Caissons Inspection - Residential Passed 10/14/2021 (10:00) 10/14/2021 10/14/2021
Erosion Control Inspection Residential Failed 10/14/2021 10/14/2021 10/14/2021
DCM2 ESC DEFICIENT INSTALLATION
Resolved
10/14/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. **RESTORE EROSION CONTROL ALONG THE STREET, ESPECIALLY AT STORM INLET. CLEAN STREET
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
10/14/2021
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Electrical Service Inspection Failed 12/22/2021 12/22/2021 12/22/2021
Misc
Corrective Action Required
12/22/2021
-clamp for UFER must be type listed for use with rebar, separation of dissimilar metals with GEC
Gas Service Inspection - Residential Failed 12/22/2021 12/22/2021 12/22/2021
Misc
Corrective Action Required
12/22/2021
-Gas pressure at 0 psi, must maintain 10 psi for test
All Rough Inspection - Residential Failed 12/22/2021 12/22/2021 12/22/2021
Miscellaneous Correction
Informational
09/15/2021
-PORTAL FRAME INSPECTION 8-15-21 **OK TO COVER EXTERIOR ONLY
Misc
Corrective Action Required
12/22/2021
-furr down ceiling and bump out garage wall to allow for insulation at HVAC -structural straps required at top plates bored 50% or more at all exterior walls and interior load bearing walls -furr out for gas line at garage -add nail protection plate at bottom plate SE cable 1st floor rear East bed -support all DWV every 48” oc, traps not considered support -add joist hangers at headers 1st floor rear East bedroom -Address overbored studs for DWV 1stbfloor bath -protection plate bottom plate pex for fridge kitchen -nail all joist hangers breakfast -Nail all intersecting wall corners 12” oc -address floor joist bored less than 2” from top of joist -kitchen breakfast -dbl top plate requires min 24” offset between plate breaks - see great room fireplace, kitchen breakfast -fireblock HVAC/plumbing chase at great room -3.5” steel column at garage beam per plans -(5) 2x4 stud packs at each bearing end beam per plans -nail all cj hangers at garage -support hip to beam at garage per plans -dbl every other 2x10 joist area as noted on plans 1st floor bedroom East -address overbored stud for DWV 1st floor bedroom hall -floor joist must bear at min 1 1/2” above entry, see dbl joist at west end of front entry -Nail all ceiling joist hangers 2nd floor -fireblock HVAC/plumbing chase master closet -No roof load on master bedroom box vault per plans -Nail all ceiling joists to rafters with (3) 16D nails and joists to plate with (3) 16D nails per plans -purlins per plans -collar ties every 48” oc, rafter ties where ceiling joists are perpendicular to rafters per plans -seal penetrations in air return for water heater pex at basement -3 1/3” SCH 40 steel columns at basement beam pier locations “D” and “C” per plans, 3” installed -Ground metal light plates -security type flood light required at rear yard -Unable to inspect covered patio framing with lid cover -Nail all exterior sheathing per plans -clamp for UFER must be type listed for use with rebar, separation of dissimilar metals with GEC -Gas pressure at 0 psi, must maintain 10 psi for test
Electrical Service Inspection Failed 1/5/2022 1/5/2022 01/05/2022
Misc
Corrective Action Required
12/22/2021
-clamp for UFER must be type listed for use with rebar, separation of dissimilar metals with GEC
All Rough Inspection - Residential Not Ready 1/5/2022 1/5/2022 01/05/2022
Miscellaneous Correction
Informational
12/22/2021
-PORTAL FRAME INSPECTION 8-15-21 **OK TO COVER EXTERIOR ONLY
Misc
Corrective Action Required
12/22/2021
-furr down ceiling to allow for insulation at HVAC at garage -secure all vertical DWV 2” or less at mid point -structural straps required at top plates bored 50% or more at all exterior walls and interior load bearing walls -add nail protection plate at bottom plate SE cable 1st floor rear East bed -nail off joist hangers at headers 1st floor rear East bedroom -Address overbored studs for DWV 1st floor bath -protection plate bottom plate pex for fridge kitchen -Nail off al joist hangers 1st floor -fireblock HVAC/plumbing chase at great room -repair plumbing that has been removed for addition of floor joists, 1st floor bedroom East -address overbored stud for DWV 1st floor bedroom hall -Nail all ceiling joist hangers 2nd floor ,see master bath -seal penetrations in air return for water heater pex at basement -3 1/2” SCH 40 steel columns at basement beam pier locations “D” and “C” per plans, 3” installed -Ground metal light plates -clamp for UFER must be type listed for use with rebar, separation of dissimilar metals with GEC
Gas Service Inspection - Residential Passed 1/5/2022 1/5/2022 01/05/2022
Misc
Resolved
01/05/2022
All Rough Inspection - Residential Failed 1/11/2022 1/11/2022 01/11/2022
Miscellaneous Correction
Informational
01/05/2022
-PORTAL FRAME INSPECTION 8-15-21 **OK TO COVER EXTERIOR ONLY
Misc
Corrective Action Required
01/05/2022
-furr down ceiling to allow for insulation at HVAC at garage -fireblock HVAC/plumbing chase at great room -address overbored stud for DWV 1st floor bedroom hall -seal penetrations in air return for water heater pex at basement -3 1/2” SCH 40 steel columns at basement beam pier locations “D” and “C” per plans, 3” installed -Nail joist hangers in dining
Electrical Service Inspection Passed 1/11/2022 1/11/2022 01/11/2022
Misc
Resolved
01/11/2022
-clamp for UFER must be type listed for use with rebar, separation of dissimilar metals with GEC
Erosion Control Inspection Residential Failed 1/12/2022 01/12/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
10/14/2021
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -remove gravel and debris from street.
All Rough Inspection - Residential Failed 1/12/2022 1/12/2022 01/12/2022
Miscellaneous Correction
Informational
01/11/2022
-PORTAL FRAME INSPECTION 8-15-21 **OK TO COVER EXTERIOR ONLY
Misc
Corrective Action Required
01/11/2022
-address overbored stud for DWV 1st floor bedroom hall -Nail joist hangers in dining
All Rough Inspection - Residential Passed 1/18/2022 1/18/2022 01/18/2022
Miscellaneous Correction
Resolved
01/18/2022
-PORTAL FRAME INSPECTION 8-15-21 **OK TO COVER EXTERIOR ONLY
Misc
Resolved
01/18/2022
-address overbored stud for DWV 1st floor bedroom hall -Nail joist hangers in dining
Driveway Inspection Partial 2/15/2022 2/15/2022 02/15/2022
Misc
Informational
02/15/2022
On Tuesday 2.15.2022 I performed a driveway inspection and pass the subgrade to pour concrete
Occupancy Inspection - Codes Residential Failed 4/11/2022 4/11/2022 04/11/2022
Misc
Corrective Action Required
04/11/2022
-Resolve outstanding inspection fees -final driveway inspection required, contact development services to schedule -Submit as graded plot plan for review and approval -Obtain lawn irrigation system permit -address fall of grade around water meter lid at front of lot, raise meter lid to grade, ensure to maintain 14"-18" max required clearance from top of meter to top of lid -Handrail required at front stairs, 4 rises -guardrail required at front porch, right side, more than 30” from grade -handrail required at rear sliding glass door stairs, 4 rises -splash blocks at all downspout and sump pump discharge locations, min 36” discharge from foundation -seal all penetrations in siding, seal across top of AC disconnect and meter can -can’t test GFCI receptacles in garage with all of the construction trash piled up -secure hanging light fixture 2nd floor bed -basement stairs handrail must terminate at either newell post or safety terminal -install anti siphon device at spigot main waiter line basement, shear head off set screw after tightening -Install discharge pipe at hot water heater, max 6” AFF -AFCI protection required at washer circuit -Secure AC electrical whip within 12” of disconnect
Erosion Control Inspection Residential Passed 4/11/2022 4/11/2022 04/11/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
04/11/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -remove gravel and debris from street.
Driveway Inspection Passed 4/12/2022 4/12/2022 04/12/2022
Misc
Informational
02/15/2022
On Tuesday 2.15.2022 I performed a driveway inspection and pass the subgrade to pour concrete
Occupancy Inspection - Codes Residential Temporary C of O 4/19/2022 4/19/2022 04/19/2022
Misc
Corrective Action Required
04/11/2022
-Submit as graded plot plan for review and approval -Obtain lawn irrigation system permit - water meter required 14" min -18" max clearance from top of meter to top of lid **OK FOR TCO - TCO EXPIRES 5/19/22**
Occupancy Inspection - Codes Residential Failed 5/5/2022 5/5/2022 05/05/2022
Misc
Corrective Action Required
04/19/2022
-Submit as graded plot plan for review and approval, (NO AS GRADED PLOT PLAN HAS BEEN RECEIVED) - water meter required 14" min -18" max clearance from top of meter to top of lid, (CURRENTLY HAS 2 RISES ON WELL, 30" FROM METER TO LID) **OK FOR TCO - TCO EXPIRES 5/19/22**
Occupancy Inspection - Codes Residential Temporary C of O 5/16/2022 5/16/2022 05/13/2022
Misc
Corrective Action Required
05/05/2022
-Submit as graded plot plan for review and approval, (NO AS GRADED PLOT PLAN HAS BEEN RECEIVED) - water meter required 14" min -18" max clearance from top of meter to top of lid, (CURRENTLY HAS 2 RISES ON WELL, 30" FROM METER TO LID) **OK FOR TCO - TCO EXPIRES 6/13/22**
Water Service Inspection - R Passed 5/16/2022 (9:15) 5/16/2022 05/16/2022
Plot Plan Inspection Passed 5/17/2022 5/17/2022 05/17/2022
Occupancy Inspection - Codes Residential Full C of O 5/17/2022 5/17/2022 05/17/2022
Misc
Resolved
05/17/2022
Documents & Images
Date Uploaded File Type Document Name
05/12/2021 Application Form Permit Application
05/12/2021 Application Form License Agreement
05/13/2021 Permit Codes Residential Plan Review
05/20/2021 Approved Plans Approved Drawings
05/21/2021 Plot Plan Approved Plot Plan
05/21/2021 Permit Codes Residential Plan Review
05/21/2021 Permit DS Building Permit
05/21/2021 Receipt Receipt for transaction:2021-003379
07/06/2021 Letter INSPECTION SUMMARY
08/12/2021 Letter INSPECTION SUMMARY
08/13/2021 Letter INSPECTION SUMMARY
08/13/2021 Letter INSPECTION SUMMARY
09/15/2021 Letter INSPECTION SUMMARY
09/15/2021 Letter INSPECTION SUMMARY
10/06/2021 Letter INSPECTION SUMMARY
10/07/2021 Letter INSPECTION SUMMARY
10/14/2021 Letter INSPECTION SUMMARY
10/14/2021 Letter INSPECTION SUMMARY
12/22/2021 Letter INSPECTION SUMMARY
12/22/2021 Letter INSPECTION SUMMARY
12/22/2021 Letter INSPECTION SUMMARY
01/05/2022 Letter INSPECTION SUMMARY
01/05/2022 Letter INSPECTION SUMMARY
01/05/2022 Letter INSPECTION SUMMARY
01/11/2022 Letter INSPECTION SUMMARY
01/11/2022 Letter INSPECTION SUMMARY
01/12/2022 Letter INSPECTION SUMMARY
01/12/2022 Letter INSPECTION SUMMARY
01/18/2022 Letter INSPECTION SUMMARY
02/15/2022 Letter INSPECTION SUMMARY
04/11/2022 Letter INSPECTION SUMMARY
04/11/2022 Letter INSPECTION SUMMARY
04/11/2022 Letter INSPECTION SUMMARY
04/12/2022 Receipt Receipt for transaction:2022-001998
04/13/2022 1837 SW Sage Canyon ROW
04/13/2022 1837 SW Sage Canyon Approved Plot Plan
04/19/2022 Letter Codes Temporary Certificate of Occupancy
04/27/2022 Letter INSPECTION SUMMARY
05/05/2022 Letter INSPECTION SUMMARY
05/09/2022 Plot Plan Approved As Graded Plot Plan
05/13/2022 Letter Codes Temporary Certificate of Occupancy
05/16/2022 Letter INSPECTION SUMMARY
05/17/2022 Letter INSPECTION SUMMARY
05/17/2022 Letter Field Certificate of Occupancy
05/17/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home