Summary
PRRES20204752
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSS - UNFINISHED BASEMENT - CLAY TILE ROOF
12/14/2020
12/22/2020
06/19/2021
12/10/2021
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 12/28/2020 12/22/2020
Dylan Eppert
As-graded plot plan
Corrective Action Required
12/22/2020

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Residential Plan Review Approved 12/28/2020 12/22/2020
Dylan Eppert
Plot Plan Review Rejected 12/16/2020 12/21/2020
Dylan Eppert
As-graded plot plan
Corrective Action Required
12/21/2020

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Planning Review (RES) Approved 12/18/2020 12/16/2020
Shannon McGuire
Residential Plan Review Approved 12/16/2020 12/16/2020
Dylan Eppert
06 Designate use of each room or space
Corrective Action Required
12/16/2020

Designate use of each room or space including but not limited to; basement storage, garages, and attic areas intended for storage space. Please clarify the plan shows "bedroom #3" however the application shows unfinished basement with nothing but the stairs to be finished.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $914.46 $914.46 Paid 12/22/2020
8331507-Sewer Connection Fee $390.00 $390.00 Paid 12/22/2020
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 12/22/2020
8350015-Water Meter Fee $455.54 $455.54 Paid 12/22/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 12/22/2020
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 12/22/2020
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 10/12/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 10/12/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 10/12/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 11/12/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 11/12/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Piers/Caissons Inspection - Residential Passed 2/1/2021 02/01/2021
Misc
Corrective Action Required
02/01/2021
(3) POURED WITH FOOTING
Footing Inspection - Residential Partial 2/1/2021 (10:30) 2/1/2021 02/01/2021
Misc
Resolved
04/09/2021
- UFER FOUNDATION WALL REAR OF GARAGE -
Sewer Service Inspection - R Passed 3/4/2021 (1:00) 3/4/2021 03/04/2021
Erosion Control Inspection Residential Failed 3/9/2021 03/09/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
03/09/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - PROVIDE ADDRESS - - MAINTAIN SILT FENCE - - MAINTAIN GRAVEL FILTER -
Water Service Inspection - R Passed 3/9/2021 (9:00) 3/9/2021 03/09/2021
Underslab Plumbing Inspection - Residential Failed 4/6/2021 4/6/2021 04/06/2021
R506.2.5 Interior Underslab Drains
Corrective Action Required
04/06/2021
- PROVIDE INTERIOR DRAIN TILE - CONCRETE FLOORS (ON GROUND). ADDED 7-927. Where foundations retain earth and enclose habitable or usable space located below grade, drains shall be provided below the floor slab. Drainage tiles, perforated pipe or other approved systems or materials shall be installed at or below the area(s) to be protected; shall be placed with positive or neutral slope to minimize the accumulation of deposits in the drainage system; and shall discharge by gravity or mechanical means to an approved storm water drainage system. The underslab drainage system shall be installed around the inner perimeter of the area(s) to be protected, or, in a manner that will provide adequate drainage for all area(s) to be protected and is approved by the building official. Interior underslab drains installed on uncompacted fill material shall be supported by mechanical means which are adequately tied into the concrete slab to ensure proper drainage throughout the underslab drain(s).
Erosion Control Inspection Residential Failed 4/6/2021 04/06/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
03/09/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - PROVIDE ADDRESS - - MAINTAIN SILT FENCE - - MAINTAIN GRAVEL FILTER -
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
04/06/2021
- MAINTAIN SILT FENCE - DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Footing Inspection - Residential Passed 4/9/2021 04/09/2021
Misc
Partial Correction
02/01/2021
- SUBMIT ENGINEERS SOIL REPORT TO BE UPLOADED TO PERMIT - - UFER FOUNDATION WALL REAR OF GARAGE -
Underslab Plumbing Inspection - Residential Not Ready 4/12/2021 4/12/2021 04/12/2021
R506.2.5 Interior Underslab Drains
Corrective Action Required
04/06/2021
- PROVIDE INTERIOR DRAIN TILE - - STILL NO INTERIOR DRAIN TILE Michael Harkins 04/12/2021 7:51 AM - CONCRETE FLOORS (ON GROUND). ADDED 7-927. Where foundations retain earth and enclose habitable or usable space located below grade, drains shall be provided below the floor slab. Drainage tiles, perforated pipe or other approved systems or materials shall be installed at or below the area(s) to be protected; shall be placed with positive or neutral slope to minimize the accumulation of deposits in the drainage system; and shall discharge by gravity or mechanical means to an approved storm water drainage system. The underslab drainage system shall be installed around the inner perimeter of the area(s) to be protected, or, in a manner that will provide adequate drainage for all area(s) to be protected and is approved by the building official. Interior underslab drains installed on uncompacted fill material shall be supported by mechanical means which are adequately tied into the concrete slab to ensure proper drainage throughout the underslab drain(s).
Erosion Control Inspection Residential Failed 4/16/2021 04/16/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
04/06/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDE - MAINTAIN SILT FENCE - - MAINTAIN GRAVEL FILTER -
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
04/06/2021
- MAINTAIN SILT FENCE - - MAINTAIN GRAVEL FILTER - DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Underslab Plumbing Inspection - Residential Passed 4/16/2021 4/16/2021 04/16/2021
R506.2.5 Interior Underslab Drains
Resolved
04/16/2021
All Rough Inspection - Residential Failed 6/9/2021 6/9/2021 06/09/2021
Misc
Informational
06/09/2021
PARTIAL INSPECTION GARAGE PORTAL FRAMING ,DECK CEILING ,PORCH CEILING Fasten top plate to header with two rows of 16D sinkers at 3" OC per plan @ PFH portal frame Solid block sheathing breaks above LVL Provide LUS24 hangers truss H01/JO3 @ front porch per plan Covered deck ok to cover
Gas Service Inspection - Residential Passed 7/8/2021 7/8/2021 07/08/2021
All Rough Inspection - Residential Failed 7/27/2021 7/27/2021 07/27/2021
Misc
Informational
06/09/2021
PARTIAL INSPECTION GARAGE PORTAL FRAMING ,DECK CEILING ,PORCH CEILING Fasten top plate to header with two rows of 16D sinkers at 3" OC per plan @ PFH portal frame Solid block sheathing breaks above LVL Provide LUS24 hangers truss H01/JO3 @ front porch per plan Covered deck ok to cover
Miscellaneous Correction
Corrective Action Required
07/27/2021
Tighten anchor bolts basement Provide anchor bolts within 12" of plate break & end of plates Anchor bolts shall land in middle 1/3 the width of plate Provide bottom plate w/ anchor bolts tie wall together SW corner basement Install missing window basement West end of basement provide double 2x10 Joist every other per plan Provide CS-PF exterior bracing per plan basement patio, dining, great room, bed #1 Nail exterior sheathing per code 6" edges 12" field Provide anchor bolt end of plate west wall garage Seal fire blocking chase laundry room Nail stud to stud and abutting bstuds at intersecting wall corners at braced wall panels Fire stop double wall at top plate laundry room Address trusses notched flush with wall master closet Address bores in LVL above garage door for coach lights Solid block & nail sheathing breaks per code master bed Exterior wall studs at 16" OC per plan add studs great room Seal upward penetration east wall bed #2 Seal upward penetration east wall garage Nail hanger rear truss 2 car garage Provide truss lock screws or H2.5s above front door Provide truss lock screws or H2.5 double girder master closet
All Rough Inspection - Residential Failed 7/27/2021 07/27/2021
Misc
Informational
07/27/2021
PARTIAL INSPECTION GARAGE PORTAL FRAMING ,DECK CEILING ,PORCH CEILING Fasten top plate to header with two rows of 16D sinkers at 3" OC per plan @ PFH portal frame Solid block sheathing breaks above LVL Provide LUS24 hangers truss H01/JO3 @ front porch per plan Covered deck ok to cover
Miscellaneous Correction
Corrective Action Required
07/27/2021
Tighten anchor bolts basement Provide anchor bolts within 12" of plate break & end of plates Anchor bolts shall land in middle 1/3 the width of plate Provide bottom plate w/ anchor bolts tie wall together SW corner basement Install missing window basement West end of basement provide double 2x10 Joist every other per plan Provide CS-PF exterior bracing per plan basement patio, dining, great room, bed #1 Nail exterior sheathing per code 6" edges 12" field Provide anchor bolt end of plate west wall garage Seal fire blocking chase laundry room Nail stud to stud and abutting bstuds at intersecting wall corners at braced wall panels Fire stop double wall at top plate laundry room Address trusses notched flush with wall master closet Address bores in LVL above garage door for coach lights Solid block & nail sheathing breaks per code master bed Exterior wall studs at 16" OC per plan add studs great room Seal upward penetration east wall bed #2 Seal upward penetration east wall garage Nail hanger rear truss 2 car garage Provide truss lock screws or H2.5s above front door Provide truss lock screws or H2.5 double girder master closet
All Rough Inspection - Residential Not Ready 8/11/2021 8/11/2021 08/11/2021
Misc
Informational
07/27/2021
PARTIAL INSPECTION GARAGE PORTAL FRAMING ,DECK CEILING ,PORCH Covered deck ok to cover Ok to cover all
Miscellaneous Correction
Corrective Action Required
07/27/2021
Provide bottom plate w/ (anchor bolts) tie wall together SW corner basement Install missing window basement Provide CS-PF exterior bracing per plan basement patio, ( missing straps) Address trusses notched flush with wall master closet ( no engineer letter) Address bores in LVL above garage door for coach lights ( no engineer letter) Solid block & nail sheathing per code above service panel
Electrical Service Inspection Passed 8/18/2021 8/18/2021 08/18/2021
All Rough Inspection - Residential Not Ready 8/18/2021 8/18/2021 08/18/2021
Misc
Informational
08/11/2021
PARTIAL INSPECTION GARAGE PORTAL FRAMING ,DECK CEILING ,PORCH Covered deck ok to cover Ok to cover all
Miscellaneous Correction
Corrective Action Required
08/11/2021
Install missing window basement Provide CS-PF exterior bracing per plan basement patio, ( missing straps) : PER 2018 IRC FIGURE R602.10.6.4 : : HEADER TO JACK STUD STRAP PER TABLE R602.10.6.4 ON BOTH SIDES OF OPENING OPPOSITE SIDE OF SHEATHING : Address trusses notched flush with wall master closet ( no engineer letter)
All Rough Inspection - Residential Passed 8/19/2021 8/19/2021 08/19/2021
Misc
Informational
08/18/2021
PARTIAL INSPECTION GARAGE PORTAL FRAMING ,DECK CEILING ,PORCH Covered deck ok to cover Ok to cover all
Miscellaneous Correction
Resolved
08/19/2021
Driveway Inspection Partial 9/20/2021 9/20/2021 09/20/2021
Misc
Informational
09/20/2021
Forms are in place and rock is present and compacted. Right of way is in ADA spec.
Driveway Inspection Passed 9/24/2021 9/24/2021 09/24/2021
Misc
Informational
09/20/2021
Forms are in place and rock is present and compacted. Right of way is in ADA spec.
Misc
Informational
09/24/2021
Driveway is good and meets ADA spec
Sidewalk Inspection Partial 10/7/2021 10/7/2021 10/07/2021
Misc
Informational
10/07/2021
10-7-21 10:28 AN forms are in place and aggregate is present and compacted
Sidewalk Inspection Passed 10/15/2021 10/15/2021 10/12/2021
Misc
Informational
10/07/2021
10-7-21 10:28 AN forms are in place and aggregate is present and compacted
Misc
Informational
10/12/2021
10-12-21 AN sidewalk looks good and meets ADA specs
Occupancy Inspection - Codes Residential Not Ready 11/5/2021 11/5/2021 11/05/2021
Occupancy Inspection - Codes Residential Not Ready 11/10/2021 11/10/2021 11/10/2021
Misc
Corrective Action Required
11/10/2021
3RD ATTEMPT TO SCHEDULE- Spencer never walked or called me back . this was removed from the schedule on 11/09 and rescehduled by Mike. see pic not ready
Occupancy Inspection - Codes Residential Temporary C of O 11/15/2021 11/12/2021 11/12/2021
Misc
Corrective Action Required
11/10/2021
outlet on front porch not GFCI --final grading and sod --check water meter hight at final grading --splash blocks
Occupancy Inspection - Codes Residential Full C of O 12/10/2021 12/10/2021 12/10/2021
Misc
Resolved
12/10/2021
Documents & Images
Date Uploaded File Type Document Name
12/14/2020 Application Form W1 #19 - Permit App
12/14/2020 19 WOODSIDE RIDGE ROOF LAYOUT
12/14/2020 2552987 RF SEAL 12042020
12/14/2020 W1 #19 - Palermo - Mediterranean - Sheets- signed
12/16/2020 LOT 19 FINAL
12/16/2020 Specifications approved roof truss package
12/16/2020 Drawing APPROVED ROOF TRUSS LAYOUT
12/16/2020 Plans APPROVED HOUSE PLANS
12/21/2020 Letter Codes Residential Plan Review
12/22/2020 Plot Plan approved plot plan
12/22/2020 Receipt Receipt for transaction:2020-008168
12/22/2020 Letter DS Building Permit
02/01/2021 Letter INSPECTION SUMMARY
02/01/2021 Letter INSPECTION SUMMARY
03/04/2021 Letter INSPECTION SUMMARY
03/09/2021 Letter INSPECTION SUMMARY
03/09/2021 Letter INSPECTION SUMMARY
04/06/2021 Letter INSPECTION SUMMARY
04/06/2021 Letter INSPECTION SUMMARY
04/09/2021 W1-19 Woodside Ridge Subgrade
04/09/2021 Letter INSPECTION SUMMARY
04/12/2021 Letter INSPECTION SUMMARY
04/12/2021 Letter INSPECTION SUMMARY
04/16/2021 Letter INSPECTION SUMMARY
04/16/2021 Letter INSPECTION SUMMARY
06/09/2021 Letter INSPECTION SUMMARY
07/08/2021 Letter INSPECTION SUMMARY
07/27/2021 Letter INSPECTION SUMMARY
08/09/2021 Approved Plans APPROVED TRUSS PACKAGE
08/09/2021 Approved Plans APPROVED TRUSS PACKAGE
08/11/2021 Letter INSPECTION SUMMARY
08/12/2021 Approved Plans Approved Revisions Truss Package
08/12/2021 Approved Plans Approved Revisions Truss Package
08/13/2021 W1-19-- LVL Structural Inspection
08/18/2021 Letter INSPECTION SUMMARY
08/18/2021 Letter INSPECTION SUMMARY
08/19/2021 W1-19 truss fix -E10
08/19/2021 W1-19 truss fix-A04
08/19/2021 Letter INSPECTION SUMMARY
09/20/2021 Letter INSPECTION SUMMARY
09/24/2021 Letter INSPECTION SUMMARY
10/07/2021 Letter INSPECTION SUMMARY
10/12/2021 Letter INSPECTION SUMMARY
10/12/2021 Receipt Receipt for transaction:2021-007940
11/05/2021 Letter INSPECTION SUMMARY
11/10/2021 2045
11/10/2021 Letter INSPECTION SUMMARY
11/12/2021 Receipt Receipt for transaction:2021-008718
11/12/2021 Letter Codes Temporary Certificate of Occupancy
12/10/2021 Letter Codes Final Certificate of Occupancy
12/10/2021 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home