Permit Application Status

PRRES20202013


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20202013
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK CLOSED WITH OPEN VIOLATIONS OR EXCEEDED PERMIT LIMITS
07/21/2020
08/11/2020
02/27/2024
Locations
Contacts
NICK ZVACEK CONSTRUCTION LLC, Address:1009 INDUSTRIAL DR, Phone:(816) 213-7204  
NZVACEK@GMAIL.COM  
COMFORT SYSTEMS HTG/CLG, Address:17232 BEL-RAY PL, Phone:(816) 322-1013  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
CENTURY PLUMBING, Address:14001 CENTURY LN, Phone:(816) 765-6066  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 07/23/2020 07/30/2020
Dylan Eppert
As-graded plot plan
Corrective Action Required
07/23/2020

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Residential Plan Review Approved 07/23/2020 07/23/2020
Dylan Eppert
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,081.19 $1,081.19 Paid 08/11/2020
8331507-Sewer Connection Fee $390.00 $390.00 Paid 08/11/2020
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 08/11/2020
8350015-Water Meter Fee $455.54 $455.54 Paid 08/11/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 08/11/2020
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 08/11/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 8/20/2020 (10:00) 8/20/2020 08/20/2020
Underslab Plumbing Inspection - Residential Failed 10/14/2020 10/14/2020 10/14/2020
Misc
Corrective Action Required
10/14/2020
- UNCOVER INTERIOR DRAIN TILE FROM GRAVEL COVER FOR INSPECTION
Underslab Plumbing Inspection - Residential Failed 10/15/2020 10/15/2020 10/15/2020
Misc
Corrective Action Required
10/14/2020
- INTERIOR DRAIN TILE MUST REACH MUST OPPOSITE CORNER OF FOUNDATION FOOTING AT NE CORNER. EXTEND OR UNCOVER DRAIN TILE ALONG NORTH WALL. ENSURE POSITIVE OR NEUTRAL SLOPE ON DRAIN TILE.
Underslab Plumbing Inspection - Residential Passed 10/19/2020 10/19/2020 10/19/2020
Misc
Resolved
10/19/2020
Sewer Service Inspection - R Passed 12/28/2020 (8:15) 12/28/2020 12/28/2020
Water Service Inspection - R Passed 12/30/2020 (10:45) 12/30/2020 12/30/2020
Erosion Control Inspection Residential Failed 1/20/2021 1/20/2021 01/20/2021
DCM5 ESC INSP DENIED
Corrective Action Required
01/20/2021
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. -SILT FENCE REQUIRED AT FRONT OF LOT, MAINTAIN GRAVEL FILTER, CLEAN ANY MUD FROM STREET
All Rough Inspection - Residential Failed 1/20/2021 1/20/2021 01/20/2021
Misc
Corrective Action Required
01/20/2021
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. -SILT FENCE REQUIRED AT FRONT OF LOT, MAINTAIN GRAVEL FILTER, CLEAN ANY MUD FROM STREET
Electrical Service Inspection Passed 1/28/2021 1/28/2021 01/28/2021
Gas Service Inspection - Residential Passed 1/28/2021 1/28/2021 01/28/2021
Gas Piping Inspection - Residential Passed 1/28/2021 1/28/2021 01/28/2021
All Rough Inspection - Residential Failed 1/28/2021 1/28/2021 01/28/2021
Misc
Corrective Action Required
01/20/2021
-Fireblock vertical to horizontal at furred down in garage -Structural straps at all top plates bored 50% or more on all interior load bearing walls and all exterior walls -Secure vertical DWV 2” or less at mid point -Nail all ceiling joist hangers - see master closet -Seal all top and bottom plate penetrations -Install and complete all bath exhaust fans and discharge -Install back door -Provide proper slope at horizontal vent lines in attic -Protection plates at NM within 1 1/4” end of stud - see front entry N wall, great room fireplace wall, master closet, kitchen N wall, bed#2 top plate -Fireblock vertical to horizontal at basement furred down ends -Basement, Fireblock between top plates/foundation, seal all gaps in Fireblock -Fireblock vertical every 10’ between framing/foundation, seal all gaps in Fireblock -Garage PFH - FASTEN SHEATHING TO HEADER WITH 8D COMMON OR GALVANIZED BOX NAILS IN 3'' GRID PATTERN AS SHOWN R602.10.6.2, see detail in sheet 6 -Nail sheathing per plans 6” edge, 12” field **Deck not completed at time of rough in inspection**
All Rough Inspection - Residential Failed 2/4/2021 2/4/2021 02/04/2021
Misc
Corrective Action Required
01/28/2021
-Seal all top and bottom plate penetrations -unused bottom plate bore laundry, master closet bottom for NM, E wall -Install back door at deck -Fireblock vertical to horizontal at basement furred down ends - basement bath N wall above shower -Garage PFH - FASTEN SHEATHING TO HEADER WITH 8D COMMON OR GALVANIZED BOX NAILS IN 3'' GRID PATTERN AS SHOWN R602.10.6.2, see detail in sheet 6 -Nail sheathing per plans 6” edge, 12” field **OK TO INSULATE**
All Rough Inspection - Residential Failed 2/9/2021 2/9/2021 02/09/2021
Misc
Corrective Action Required
02/04/2021
-Seal all top and bottom plate penetrations -unused bottom plate bore laundry, master closet bottom for NM, E wall -Install back door at deck **OK TO INSULATE**
All Rough Inspection - Residential Passed 2/11/2021 2/11/2021 02/11/2021
Misc
Resolved
02/11/2021
Piers/Caissons Inspection - Residential Passed 3/29/2021 (11:15) 3/29/2021 03/29/2021
Driveway Inspection Partial 3/30/2021 03/30/2021
Misc
Informational
03/30/2021
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Partial 3/30/2021 03/30/2021
Misc
Informational
03/30/2021
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Partial 4/6/2021 4/12/2021 04/12/2021
Misc
Informational
03/30/2021
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Misc
Informational
04/12/2021
4/12/21 Monday Sidewalk - forms and materials passed pre-inspection.
Driveway Inspection Partial 4/12/2021 4/12/2021 04/12/2021
Misc
Informational
03/30/2021
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Misc
Informational
04/12/2021
4/12/21 Monday Driveway - forms and materials passed pre-inspection.
Sidewalk Inspection Passed 4/14/2021 4/14/2021 04/14/2021
Misc
Informational
04/12/2021
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Misc
Informational
04/12/2021
4/12/21 Monday Sidewalk - forms and materials passed pre-inspection.
Misc
Informational
04/14/2021
4/14/21 Sidewalk - passed final inspection.
Driveway Inspection Passed 4/14/2021 4/14/2021 04/14/2021
Misc
Informational
04/12/2021
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Misc
Informational
04/12/2021
4/12/21 Monday Driveway - forms and materials passed pre-inspection.
Misc
Informational
04/14/2021
4/14/21 Driveway - passed final inspection.
Occupancy Inspection - Codes Residential Failed 7/1/2021 7/1/2021 07/01/2021
Misc
Corrective Action Required
07/01/2021
INSPECTION DENIED - NO ADDRESS POSTED - EROSION CONTROL REQUIRED UNTIL SOD IS PLACED
Erosion Control Inspection Residential Failed 7/1/2021 7/1/2021 07/01/2021
DCM5 ESC INSP DENIED
Corrective Action Required
01/20/2021
EROSION CONTROL REQUIRED UNTIL SOD IS PLACED
Occupancy Inspection - Codes Residential Failed 7/6/2021 7/6/2021 07/06/2021
Misc
Corrective Action Required
07/01/2021
-Submit as graded plot plan for review and approval -Obtain lawn irrigation system permit -Final grade and sod -Guardrail at front porch, more than 30" from grade -Splash blocks at downspouts and sump pump discharge, min 36" discharge from foundation -Exterior light fixture at basement walkout must be sealed type fixture less than 8’ from walking surface -Tamper resistant valve caps required at AC compressor -Install locking hardware sliding glass door, (2) locking devices required on sgd -Interconnection required of all smokes, see basement bed
Occupancy Inspection - Codes Residential Temporary C of O 7/7/2021 07/07/2021
Misc
Corrective Action Required
07/06/2021
-Obtain lawn irrigation system permit -Final grade and sod -Guardrail at front porch, more than 30" from grade -Splash blocks at downspouts and sump pump discharge, min 36" discharge from foundation -Tamper resistant valve caps required at AC compressor **OK FOR TCO - TCO EXPIRES 7/30/21**
Erosion Control Inspection Residential Passed 07/27/2021
DCM5 ESC INSP DENIED
Resolved
07/27/2021
Occupancy Inspection - Codes Residential Failed 7/27/2021 7/27/2021 07/27/2021
Misc
Corrective Action Required
07/07/2021
-Obtain lawn irrigation system permit -Submit as graded plot plan for review and approval
Documents & Images
Date Uploaded File Type Document Name
07/21/2020 Lot 55 Summit View Farms Permit Application
07/21/2020 Lot 55 Summit View Farms Blue Print Submitted
07/21/2020 Lot 55 Summit View Farms plot plan
07/21/2020 Lot 55 Summit View Farms Tax App
07/23/2020 Plans APPROVED HOUSE PLANS
07/23/2020 Letter Codes Residential Plan Review
07/24/2020 Plot Plan APPROVED PLOT PLAN
08/11/2020 Receipt Receipt for transaction: 2020-005094
08/11/2020 Letter DS Building Permit
08/20/2020 Letter INSPECTION SUMMARY
10/14/2020 Letter INSPECTION SUMMARY
10/15/2020 Letter INSPECTION SUMMARY
10/19/2020 Letter INSPECTION SUMMARY
12/28/2020 Letter INSPECTION SUMMARY
12/30/2020 Letter INSPECTION SUMMARY
01/20/2021 Letter INSPECTION SUMMARY
01/20/2021 Letter INSPECTION SUMMARY
01/28/2021 Letter INSPECTION SUMMARY
01/28/2021 Letter INSPECTION SUMMARY
01/28/2021 Letter INSPECTION SUMMARY
01/28/2021 Letter INSPECTION SUMMARY
01/28/2021 Letter INSPECTION SUMMARY
02/01/2021 Letter INSPECTION SUMMARY
02/04/2021 Letter INSPECTION SUMMARY
02/09/2021 Letter INSPECTION SUMMARY
02/11/2021 Letter INSPECTION SUMMARY
03/29/2021 Letter INSPECTION SUMMARY
03/30/2021 Letter INSPECTION SUMMARY
03/30/2021 Letter INSPECTION SUMMARY
04/12/2021 Letter INSPECTION SUMMARY
04/12/2021 Letter INSPECTION SUMMARY
04/12/2021 Letter INSPECTION SUMMARY
04/14/2021 Letter INSPECTION SUMMARY
04/14/2021 Letter INSPECTION SUMMARY
07/01/2021 Letter INSPECTION SUMMARY
07/01/2021 Letter INSPECTION SUMMARY
07/06/2021 Letter INSPECTION SUMMARY
07/06/2021 Letter INSPECTION SUMMARY
07/07/2021 Letter Codes Temporary Certificate of Occupancy
07/27/2021 Letter INSPECTION SUMMARY
07/27/2021 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home