Summary
PRRES20182736
Building Permit - Residential
Certificate of Occupancy
HUNT MIDWEST RESIDENTIAL LLC
NEW SINGLE FAMILY
NEW HOUSE FINISHED BASEMENT COVERED DECK
08/20/2018
09/20/2018
05/18/2021
Locations
Contacts
HUNT MIDWEST RESIDENTIAL LLC, Address:8300 NE UNDERGROUND DR  
MCFARLAND CUSTOM BUILDERS, Address:P O BOX 25285, Phone:(816) 215-1660  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
JOE KILOWATT INC, Address:6506 ROYAL, Phone:(816) 792-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 08/22/2018 09/07/2018
Brandon Kalwei
Plot Plan Review Approved 08/22/2018 08/23/2018
Steve Conrick
Spot elevations
Corrective Action Required
08/22/2018

Spot elevations and/or drainage flow arrows shall be provided throughout the lot. ***Please provide more spot elevations throughout the lot. After looking at the plot plan for lot 668, the elevations are not lining up.***
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,250.24 $1,250.24 Paid 09/20/2018
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 09/20/2018
8331507-Sewer Connection Fee $570.00 $570.00 Paid 09/20/2018
8331401-Water Tap Fee $3,409.00 $3,409.00 Paid 09/20/2018
8350015-Water Meter Fee $408.37 $408.37 Paid 09/20/2018
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 08/16/2019
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 08/16/2019
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 08/16/2019
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 08/16/2019
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 08/16/2019
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 08/16/2019
9110078-Valuation Fee New Single Family $51.12 $51.12 Paid 10/31/2019
$1,301.36
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 10/5/2018 10/5/2018 at 1:00 PM 10/05/2018
Underslab Plumbing Inspection - Residential Failed 11/20/2018 11/20/2018 11/20/2018
Misc
Corrective Action Required
11/20/2018
no address no erosion control no inspection
Sewer Service Inspection - R Passed 11/29/2018 11/29/2018 11/29/2018
Water Service Inspection - R Passed 11/30/2018 11/30/2018 11/30/2018
Underslab Plumbing Inspection - Residential Failed 12/4/2018 12/4/2018 12/04/2018
Misc
Corrective Action Required
11/20/2018
City required 4” clean out for the building sewer
Underslab Plumbing Inspection - Residential Passed 12/19/2018 12/19/2018 12/19/2018
Misc
Resolved
12/19/2018
City required 4” clean out for the building sewer
All Rough Inspection - Residential Not Ready 5/30/2019 5/30/2019 05/30/2019
Misc
Corrective Action Required
05/30/2019
INSTALL EROSION CONTROL AS REQURIED ALL INSPECTIONS DENIED UNTILL EROSION CONTROL IS IN PLACE
All Rough Inspection - Residential Not Ready 6/4/2019 6/4/2019 06/04/2019
Misc
Corrective Action Required
05/30/2019
INSTALL EROSION CONTROL AS REQURIED ALL INSPECTIONS DENIED UNTILL EROSION CONTROL IS IN PLACE/ no plans on site at time of inspection not ready
All Rough Inspection - Residential Not Ready 6/5/2019 6/5/2019 06/05/2019
Misc
Corrective Action Required
06/04/2019
INSTALL EROSION CONTROL AS REQURIED ALL INSPECTIONS DENIED UNTILL EROSION CONTROL IS IN PLACE/ no plans on site at time of inspection not ready
Misc
Corrective Action Required
06/05/2019
Pland are not City of Lee's summit approved plans with permit number, address or city stamp. this is not a complete list due to incorrect plans. 3rd not ready inspection. >Cut floor joist at flue first floor. > braced wall panels great room wall at top plates first floor ,no nail pattern of siding exterior first floor & pantry wall. >2 x 6 wall at stair wall as per these plans. > Flue clearance garage. > Firstop garage walls > Ceiling Joist 24”oc. Support per code or install at 16" oc. > Vent bath fans 1st floor. > Electrical in return air garage wall kitchen side. > Install valve and protect gas line at fireplace . > Thermostat wire in return air dining room wall >First IP chase flu chase garage wall vertical to horizontal. >> First stop angle wall at stairs solid material not loose insulation . >flue Clearance second floor. > install solid blocking not loose insulation for fire stop. > Strap bearing walls bored more than 50% with structural strap at top plates minimum for nails each side of cut in the plate. > Leg over master bathroom to ridge is over 45°. > protect Romex over master attic access within 6 '. > Electrical box in return air master bedroom. > Fur out basement stairs and complete electrical in ceiling . > panel solid block cantilevers in basement and block over I-beams in basement. >plumbing over electrical panel basement wall. > install studs directly under stair joist basement wall .
Electrical Service Inspection Passed 6/20/2019 6/20/2019 06/20/2019
Gas Service Inspection - Residential Passed 6/20/2019 6/20/2019 06/20/2019
All Rough Inspection - Residential Failed 6/20/2019 6/20/2019 06/20/2019
Misc
Resolved
06/20/2019
INSTALL EROSION CONTROL AS REQURIED ALL INSPECTIONS DENIED UNTILL EROSION CONTROL IS IN PLACE/ no plans on site at time of inspection not ready
Misc
Corrective Action Required
06/05/2019
>#Cut floor joist at flue first floor. ># braced wall panels great room wall at top plates first floor ,no nail pattern of siding exterior first floor & pantry wall. >#2 x 6 wall at stair wall as per these plans. ># Flue clearance garage. ># Firstop garage walls ># Ceiling Joist 24”oc. Support per code or install at 16" oc. > #Vent bath fans 1st floor. ># Electrical in return air garage wall kitchen side. seal pan. ># Thermostat wire in return air dining room wall >#Fire stop chase flu chase garage wall vertical to horizontal. >#> First stop angle wall at stairs solid material not loose insulation . >#flue Clearance second floor. ># install solid blocking not loose insulation for fire stop. ># Leg over master bathroom to ridge is over 45°. > #Electrical box in return air master bedroom. > #Fur out basement stairs and complete electrical in ceiling . > solid block cantilevers in basement and block over I-beams in basement. block all bearing locations. >#plumbing over electrical panel basement wall. ># install studs directly under stair joist basement wall .
All Rough Inspection - Residential Not Ready 8/5/2019 8/5/2019 08/05/2019
Misc
Corrective Action Required
06/20/2019
ITEMS INCOMPLETE- MOW ALL VEGITATION NO FURTHER INSPECTIONS CLEAN STREET. ADDRESS ALL ITEMS ># braced wall panels great room wall at top plates first floor ,no nail pattern of siding exterior first floor & pantry wall. ((header straps incorrect. >#2 x 6 wall at stair wall as per these plans. not addresed ># Flue clearance garage. incomplete ># Firstop garage walls incomplete ># Ceiling Joist 24”oc. Support per code or install at 16" oc. incomplete >#Fire stop chase flu chase garage wall vertical to horizontal.incomplete >#> First stop angle wall at stairs solid material not loose insulation . incomplete >#flue Clearance second floor. ># install solid blocking not loose insulation for fire stop. ># Leg over master bathroom to ridge is over 45°. > #Electrical box in return air master bedroom. > #Fur out basement stairs and complete electrical in ceiling . > solid block cantilevers in basement and block over I-beams in basement. block all bearing locations. >#plumbing over electrical panel basement wall. ># install studs directly under stair joist basement wall .
Piers/Caissons Inspection - Residential Passed 8/9/2019 8/9/2019 08/09/2019
All Rough Inspection - Residential Failed 8/12/2019 8/12/2019 08/12/2019
Misc
Corrective Action Required
08/05/2019
># braced wall panels great room wall at top plates first floor . ((header straps incorrect >#> Fire stop angle wall at stairs solid material not loose insulation . incomplete >#flue Clearance second floor. ># install solid blocking not loose insulation for fire stop. ># Leg over master bathroom to ridge is over 45°. Will clarify
All Rough Inspection - Residential Failed 8/16/2019 8/16/2019 08/16/2019
Misc
Corrective Action Required
08/12/2019
># Ceiling Joist 24”oc. Support per code or install at 16" oc. In garage fired out ceiling , incomplete..joist need 1 1/2” bearing on each end. 24” oc. 2x4 wont span 10’ with 5/8” rock. Install ceiling per code or provide engineers report. >#> Fire stop angle wall at stairs solid material not loose insulation . incomplete >#flue Clearance second floor. Solid block opening, seal from attic ther are open gaps in fire stopping. ># install solid blocking not loose insulation for fire stop. >#Fire stop flue at top plate second and first floor
All Rough Inspection - Residential Passed 8/30/2019 8/30/2019 08/30/2019
Misc
Resolved
08/30/2019
Driveway Inspection Partial 9/12/2019 (Ready Now) 9/12/2019 09/12/2019
Misc
Informational
09/12/2019
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Partial 9/12/2019 9/12/2019 09/12/2019
Misc
Informational
09/12/2019
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Passed 9/19/2019 09/25/2019
Misc
Informational
09/12/2019
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 9/19/2019 09/25/2019
Misc
Informational
09/12/2019
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
All Rough Inspection - Residential Failed 12/5/2019 12/5/2019 12/05/2019
Misc
Corrective Action Required
12/05/2019
- Fire block all top plates at double walls - fire block double walls vertically every 10’ - fire block all penetrations through top plates Ok to insulate
All Rough Inspection - Residential Passed 12/13/2019 12/13/2019 12/13/2019
Misc
Resolved
12/13/2019
Ok to insulate
Plot Plan Inspection Passed 12/13/2019 12/13/2019
Occupancy Inspection - Codes Residential Temporary C of O 3/13/2020 3/13/2020 03/13/2020
Misc
Corrective Action Required
03/13/2020
- Provide final grade, sod, splash blocks - seal exterior penetrations gas meter, meter can, AC disconnect
Occupancy Inspection - Codes Residential Temporary C of O 12/4/2020 12/4/2020 12/04/2020
Misc
Corrective Action Required
03/13/2020
- seal exterior penetrations gas meter, meter can, AC disconnect TCO EXTENDED 10 DAYS VALID THROUGH 12/14/2020
Occupancy Inspection - Codes Residential Full C of O 05/18/2021
Misc
Resolved
05/18/2021
- seal exterior penetrations gas meter, meter can, AC disconnect TCO EXTENDED 10 DAYS VALID THROUGH 12/14/2020
Documents & Images
Date Uploaded File Type Document Name
08/20/2018 Letter Codes Residential Plan Review
08/22/2018 Letter Codes Residential Plan Review
09/20/2018 Receipt Receipt for transaction: 2018-006479
09/20/2018 Letter Codes Building Permit
09/21/2018 Plot Plan DOC092018-09202018160715
10/05/2018 Letter Inspection Summary
10/05/2018 Letter Inspection Summary
11/20/2018 Letter INSPECTION SUMMARY
11/29/2018 Letter INSPECTION SUMMARY
11/29/2018 Letter INSPECTION SUMMARY
11/30/2018 Letter INSPECTION SUMMARY
11/30/2018 Letter INSPECTION SUMMARY
12/19/2018 Letter INSPECTION SUMMARY
05/30/2019 Letter INSPECTION SUMMARY
06/04/2019 Letter INSPECTION SUMMARY
06/05/2019 Letter INSPECTION SUMMARY
06/20/2019 Letter INSPECTION SUMMARY
08/05/2019 Letter INSPECTION SUMMARY
08/09/2019 Letter INSPECTION SUMMARY
08/12/2019 Letter INSPECTION SUMMARY
08/12/2019 Letter INSPECTION SUMMARY
08/16/2019 Letter INSPECTION SUMMARY
08/16/2019 Receipt Receipt for transaction: 2019-005632
08/30/2019 Letter INSPECTION SUMMARY
09/12/2019 Letter INSPECTION SUMMARY
09/12/2019 Letter INSPECTION SUMMARY
09/25/2019 Letter INSPECTION SUMMARY
09/25/2019 Letter INSPECTION SUMMARY
10/31/2019 Receipt Receipt for transaction: 2019-007094
10/31/2019 Letter DS Building Permit
12/05/2019 Letter INSPECTION SUMMARY
12/10/2019 Plot Plan Eagle Creek 14th Plat Lot 667 FG 19.1209 (002)
12/13/2019 Letter INSPECTION SUMMARY
12/13/2019 Letter INSPECTION SUMMARY
03/13/2020 Letter Codes Temporary Certificate of Occupancy
04/28/2020 Eagle Creek 14th Plat Lot 692 FG 20.0423
12/04/2020 Letter Codes Temporary Certificate of Occupancy
12/04/2020 Letter INSPECTION SUMMARY
12/04/2020 Letter INSPECTION SUMMARY
05/18/2021 Letter Codes Final Certificate of Occupancy
05/18/2021 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home