Permit Application Status

PRCOM20251166


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRCOM20251166
Building Permit - Commercial
Issued
NEW MULTI-FAMILY
THE REUNION AT BLACKWELL - BUILDING 26, TYPE C -4 PLEX PLAN REVIEW COMPLETED UNDER PRCOM20250089
03/31/2025
06/17/2025
Locations
Contacts
Avital Homes, LLC, Address:7500 W 151st Street, #23100, Phone:(816) 914-7128  
RED DOG ELECTRIC SERVICES, Address:PO BOX 1, Phone:(913) 208-4816  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
COLLINS WEBB ARCHITECTURE LLC, Address:307 SW MARKET ST, Unit B, Phone:(816) 249-2270  
Doug Jenson - Avital Homes, Phone:(816) 266-0685  
Reviews
Review Type Outcome Est. Completion Date Completed
Final Development Plan Review Approved 04/14/2025 03/31/2025
Mike Weisenborn
Building Plan Review Approved with Conditions 04/14/2025 03/31/2025
Mike Weisenborn
Miscellaneous Correction
Resolved
06/17/2025

Foundation and underlsab plumbing only released at this time. Substantial completion on the santiary and water before private connections can be made. Full access and live hydrants required prior to release of vertical construction.
Licensed Contractors Approved 04/14/2025 03/31/2025
Mike Weisenborn
Fees
Paid Fees Amount Paid Owing Date Paid
Water Tap Fee $10,595.00 $10,595.00 Paid 04/03/2025
Water Meter Fee $1,066.76 $1,066.76 Paid 04/03/2025
Sanitary Sewer Development Fee $6,101.00 $6,101.00 Paid 04/03/2025
Valuation Fee for New 3 or 4 Family $4,451.71 $4,451.71 Paid 04/03/2025
Residential Excise Tax Fee $2,480.64 $2,480.64 Paid 04/03/2025
Outstanding Fees Amount Paid Owing Date Paid
3rd and Subsequent Inspection Fee (Per Hour) $75.00 $0.00 $75.00 Not Paid


$75.00    Add Fees to My Cart
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Piers/Caissons Inspection - Commercial Pending
Erosion Control Inspection Pending
Miscellaneous Correction
Informational
05/05/2025
5-5-25 Dustin A, Erosion control is installed. Will need to be maintained through construction process.
Rated Assembly Inspection Pending
Erosion Control Inspection Pending
Water Service Inspection Pending
All Rough Inspection - Commercial Pending
Misc
Corrective Action Required
09/29/2025
NOT A COMPLETE INSPECTION, TRUSSES NOT INSPECTED DO NOT INSULATE -Provide city stamped truss plans on site for inspection Throughout -will check GB bracing at time of drywall 653 -missing stud in stud pack per plans front bedroom 655 657 659
Footing Inspection - Commercial Failed 5/5/2025 05/05/2025
Misc
Corrective Action Required
05/05/2025
failed 5/1 no erosion control
Erosion Control Inspection Partial 5/5/2025 5/5/2025 05/05/2025
Miscellaneous Correction
Informational
05/05/2025
5-5-25 Dustin A, Erosion control is installed. Will need to be maintained through construction process.
Footing Inspection - Commercial Partial 5/12/2025 05/12/2025
Misc
Resolved
05/12/2025
failed 5/1 no erosion control
Misc
Informational
05/12/2025
Footing okay to pour
Footing Inspection - Commercial Passed 5/16/2025 5/16/2025 05/16/2025
Misc
Resolved
05/16/2025
Footing okay to pour
Underslab Plumbing Inspection - Commercial Passed 5/28/2025 5/28/2025 05/28/2025
Sewer Service Inspection Passed 7/18/2025 7/18/2025 07/18/2025
Misc
Informational
07/18/2025
7-18-25 Dustin A, both sewer stubs for duplex are attached to existing 6 in sewer stub. Pass
All Rough Inspection - Commercial Failed 9/19/2025 9/19/2025 09/19/2025
Misc
Corrective Action Required
09/19/2025
NOT A COMPLETE INSPECTION -Provide city stamped truss plans on site for inspection Throughout -no more than 2 NM through top plate penetrations check throughout -protect dryer vent at top plate -repair all holes and seal all penetrations in seperation walls -ufer ground not ran yet -anchor bolts not tightened throughout -fire rated roof sheathing to extend 4’ each side of separation wall 653 -protect dwv at top plate 2” front bedroom -smoke/co outside front bedrooms not to be within 3’ of bathroom -solid bock at back door hinges -
All Rough Inspection - Commercial Failed 9/24/2025 9/24/2025 09/24/2025
Misc
Corrective Action Required
09/19/2025
NOT A COMPLETE INSPECTION, TRUSSES NOT INSPECTED -Provide city stamped truss plans on site for inspection Throughout -repair all holes and seal all penetrations in seperation walls -vertical to horizontal fire blocking to be ever 10’ in party walls (missing in areas and to far spaced in others) -screw patten on party wall behind tubs not to plans -will check GB bracing at time of drywall 653 -protect dwv at top plate 2” below front bedroom -missing stud in stud pack per plans front bedroom -provide exterior receptacle for hvac service ability -wall between 653/655 sheet rocked between part walls at garage 655 -stud spacing front bedroom exterior door all exceeding 16” -Address party wall all not full height NE -fire rated roof sheathing to extend 4’ each side of separation wall (see rear bedroom, check throughout) 657 -top plate penetration front bedroom/bathroom wall -not more than 2 NM through top plate penetration together. Rear bedroom 659 -support supply vent above bedroom up off of electrical -provide exterior receptacle for hvac service ability -outlet spacing greater than 6’ from opening rear bedroom
All Rough Inspection - Commercial Failed 9/26/2025 9/26/2025 09/26/2025
Misc
Corrective Action Required
09/24/2025
NOT A COMPLETE INSPECTION, TRUSSES NOT INSPECTED DO NOT INSULATE -Provide city stamped truss plans on site for inspection Throughout -repair all holes and seal all penetrations in seperation walls -screw patten on party wall behind tubs not to plans -will check GB bracing at time of drywall 653 -missing stud in stud pack per plans front bedroom -provide exterior receptacle for hvac service ability -wall between 653/655 sheet rocked between part walls at garage 655 -stud spacing front bedroom exterior door all exceeding 16” -fire rated roof sheathing to extend 4’ each side of separation wall (see rear bedroom, check throughout) 657 659 -support supply vent above bedroom up off of electrical
Electrical Service Inspection Passed 9/26/2025 9/26/2025 09/26/2025
All Rough Inspection - Commercial Failed 9/29/2025 9/29/2025 09/29/2025
Misc
Corrective Action Required
09/26/2025
NOT A COMPLETE INSPECTION, TRUSSES NOT INSPECTED DO NOT INSULATE -Provide city stamped truss plans on site for inspection Throughout -will check GB bracing at time of drywall 653 -missing stud in stud pack per plans front bedroom 655 657 659
Documents & Images
Date Uploaded File Type Document Name
04/03/2025 Receipt Receipt for transaction:2025-002032
04/03/2025 Letter DS Building Permit
03/31/2025 Approved Plans Approved plans V1
05/05/2025 Letter INSPECTION SUMMARY
05/05/2025 Letter INSPECTION SUMMARY
05/12/2025 Letter INSPECTION SUMMARY
05/16/2025 Letter INSPECTION SUMMARY
05/28/2025 Letter INSPECTION SUMMARY
06/17/2025 Letter DS Building Permit
07/18/2025 Letter INSPECTION SUMMARY
03/31/2025 Approved Plans Approved plans V1
03/06/2025 Approved Plans Approved plans V2
09/19/2025 Letter INSPECTION SUMMARY
09/24/2025 Letter INSPECTION SUMMARY
09/26/2025 Letter INSPECTION SUMMARY
09/26/2025 Letter INSPECTION SUMMARY
09/29/2025 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home