Permit Application Status

PRRES20245539


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20245539
Building Permit - Residential
Temporary Occupancy
DOMAIN TIMBERLAKE MULTISTATE LLC
NEW SINGLE FAMILY
NEW HOUSE. UNFINISHED BASEMENT. ROOF TRUSSES.
10/18/2024
10/29/2024
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
DOMAIN TIMBERLAKE MULTISTATE LLC, Address:590 MADISON AVE FL 13TH  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
TREVOR@SUMMITHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331401-Water Tap Fee $3,973.00 $3,973.00 Paid 10/29/2024
8350015-Water Meter Fee $748.03 $748.03 Paid 10/29/2024
8331507-Sanitary Sewer Development Fee $2,285.00 $2,285.00 Paid 10/29/2024
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 10/29/2024
7232302-Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 10/29/2024
9110078-Valuation Fee New Single Family $1,936.52 $1,936.52 Paid 10/29/2024
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 04/07/2025
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 04/07/2025
9110080-3rd and Subsequent Inspection Fee (Per Hour) $50.00 $50.00 Paid 04/07/2025
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 04/24/2025
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 04/24/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Plot Plan Inspection Pending
Misc
Corrective Action Required
04/22/2025
Remove debris piles and finish grade
Erosion Control Inspection Residential Pending
Miscellaneous Correction
Informational
04/24/2025
Erosion control is in place at the time of this inspection
Misc
Corrective Action Required
04/24/2025
Debris pile needs removed
Occupancy Inspection - Codes Residential Pending 5/24/2025
Misc
Corrective Action Required
04/24/2025
-add gravel to water meter pit -splash blocks need installed -tracer wire needs to be at grade - Sump discharge to 36” away from foundation - Needs final grade and sod - Debris pile needs to be removed - Fall protection from front porch needed if final grade is greater than 30” below porch - Cut down water shutoff in front yard to grade - Pay all fees
Sewer Service Inspection - R Passed 12/2/2024 12/2/2024 12/02/2024
Footing Inspection - Residential Passed 12/2/2024 12/2/2024 12/02/2024
Water Service Inspection - R Passed 12/3/2024 12/3/2024 12/03/2024
Underslab Plumbing Inspection - Residential Passed 12/12/2024 12/12/2024 12/12/2024
All Rough Inspection - Residential Partial 12/27/2024 12/27/2024 12/27/2024
Misc
Informational
12/27/2024
Garage portal frame nailing inspection only. Okay to cover exterior pfh
Erosion Control Inspection Residential Failed 1/23/2025 1/23/2025 01/23/2025
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
01/23/2025
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -Maintain gravel filter with min 6" lift of min 3/4" gravel
All Rough Inspection - Residential Failed 1/23/2025 1/23/2025 01/23/2025
Misc
Informational
12/27/2024
Exterior garage PFH and Front exterior only ok to cover
All Rough Inspection - Residential Not Ready 2/10/2025 2/10/2025 02/10/2025
Misc
Informational
01/23/2025
Exterior garage PFH and Front exterior only ok to cover
Misc
Corrective Action Required
02/10/2025
Inspection denied, No city stamped plans on site.
Gas Service Inspection - Residential Failed 2/10/2025 2/10/2025 02/10/2025
Misc
Corrective Action Required
02/10/2025
Bond gasline
Electrical Service Inspection Passed 2/10/2025 2/10/2025 02/10/2025
Erosion Control Inspection Residential Partial 2/12/2025 02/12/2025
DCM2 ESC DEFICIENT INSTALLATION
Resolved
02/12/2025
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -Maintain gravel filter with min 6" lift of min 3/4" gravel
Miscellaneous Correction
Informational
02/12/2025
Erosion control is in place at the time of this inspection
All Rough Inspection - Residential Not Ready 2/12/2025 2/12/2025 02/12/2025
Misc
Informational
02/10/2025
Exterior garage PFH and Front exterior only ok to cover
Misc
Resolved
02/12/2025
Inspection denied, No city stamped plans on site.
Miscellaneous Correction
Corrective Action Required
02/12/2025
-Missing fire blocking in top plate around garage double overhead door (both sides) -Fasten exterior sheathing to code at front entry to garage wall by Ibeam -Fire block top of chases in garage Install anchor bolts in garage west bottom plate to code -Secure base of steel column post in garage -3 inch DWV above garage is not completed -4 inch hole in floor above the garage -Second set of 2x6 studs are not installed along garage west wall -LIB’s in garage are not installed House is not ready for inspection Walk your property before scheduling your inspections Not a complete list
Gas Service Inspection - Residential Passed 2/12/2025 2/14/2025 02/14/2025
Misc
Resolved
02/14/2025
Bond gasline
All Rough Inspection - Residential Failed 2/14/2025 2/14/2025 02/14/2025
Misc
Resolved
02/14/2025
Exterior garage PFH and Front exterior only ok to cover
Miscellaneous Correction
Resolved
02/14/2025
-Missing fire blocking in top plate around garage double overhead door (both sides) -Fasten exterior sheathing to code at front entry to garage wall by Ibeam -Fire block top of chases in garage Install anchor bolts in garage west bottom plate to code -Secure base of steel column post in garage -3 inch DWV above garage is not completed -4 inch hole in floor above the garage -Second set of 2x6 studs are not installed along garage west wall -LIB’s in garage are not installed House is not ready for inspection Walk your property before scheduling your inspections Not a complete list
Miscellaneous Correction
Corrective Action Required
02/14/2025
- Install anchor bolts in garage west bottom plate to code ( middle 1/3 of bottom plate) - LIB in garage to pantry is not secured to the top plate - Kitchen South wall is missing the second 2x6 - Rafters above dining area does not sit on at least 1 1/2 inches of support - Nail dining area corners to code - Nail missing in joist hanger at great room to foyer LVL - Fire block top of chase and furr down in great room around HVAC duct and DWV - LIB in garage to foyer needs to extend to the corner as shown on the plans - Fire block top plate in the foyer/front porch - Nail corner of stairwell foyer going upstairs to code - Windows not installed in stairwell - Nail all corners upstairs to code - Remove all insulation netting from upstairs exterior walls for inspection - Bathroom 3 vent fan flex pipe is broken into - Protect all wiring within 6 feet of attic access hatch in upstairs utility room - Remove all ceiling insulation from bedroom 1 and 2 for inspection - Anchor bolts in basement do not appear to be properly installed into the bottom plate in several areas
All Rough Inspection - Residential Failed 2/18/2025 2/18/2025 02/18/2025
Miscellaneous Correction
Resolved
02/18/2025
- Install anchor bolts in garage west bottom plate to code ( middle 1/3 of bottom plate) - LIB in garage to pantry is not secured to the top plate - Kitchen South wall is missing the second 2x6 - Rafters above dining area does not sit on at least 1 1/2 inches of support - Nail dining area corners to code - Nail missing in joist hanger at great room to foyer LVL - Fire block top of chase and furr down in great room around HVAC duct and DWV - LIB in garage to foyer needs to extend to the corner as shown on the plans - Fire block top plate in the foyer/front porch - Nail corner of stairwell foyer going upstairs to code - Windows not installed in stairwell - Nail all corners upstairs to code - Remove all insulation netting from upstairs exterior walls for inspection - Bathroom 3 vent fan flex pipe is broken into - Protect all wiring within 6 feet of attic access hatch in upstairs utility room - Remove all ceiling insulation from bedroom 1 and 2 for inspection - Anchor bolts in basement do not appear to be properly installed into the bottom plate in several areas
Miscellaneous Correction
Corrective Action Required
02/18/2025
Nail missing in joist hanger at great room to foyer LVL Windows not installed in stairwell Remove all insulation netting from upstairs exterior walls for inspection Bathroom 3 vent fan flex pipe is broken Fire block top plate in master bedroom north wall Second truss tie down screw is not installed in master closet at girder beam Truss tie down screws are missing in bedroom 2 Anchor bolts in basement do not seem to be properly installed into the bottom plate in several areas
All Rough Inspection - Residential Failed 2/24/2025 2/24/2025 02/24/2025
Miscellaneous Correction
Corrective Action Required
02/18/2025
-address studs in master bath exterior wall board for dwv. (R602.6(1))
Erosion Control Inspection Residential Partial 02/24/2025
Miscellaneous Correction
Informational
02/12/2025
Erosion control is in place at the time of this inspection
All Rough Inspection - Residential Failed 2/26/2025 2/26/2025 02/26/2025
Miscellaneous Correction
Corrective Action Required
02/24/2025
-address studs in master bath exterior wall board for dwv. (R602.6(1))
Misc
Corrective Action Required
02/26/2025
Inspection denied no address posted.
All Rough Inspection - Residential Passed 2/27/2025 2/27/2025 02/27/2025
Miscellaneous Correction
Resolved
02/27/2025
-address studs in master bath exterior wall board for dwv. (R602.6(1))
Misc
Resolved
02/27/2025
Inspection denied no address posted.
Piers/Caissons Inspection - Residential Passed 4/3/2025 4/3/2025 04/03/2025
Driveway Inspection Partial 4/7/2025 4/7/2025 04/07/2025
Misc
Informational
04/07/2025
4/7/25 Dustin A, dw is formed and compacted approved to pour
Driveway Inspection Passed 4/18/2025 4/18/2025 04/18/2025
Misc
Informational
04/07/2025
4/7/25 Dustin A, dw is formed and compacted approved to pour 4-18-25 Dustin A, Dw is poured to city specs. Pass
Erosion Control Inspection Residential Failed 4/21/2025 04/21/2025
Miscellaneous Correction
Informational
02/24/2025
Erosion control is in place at the time of this inspection
DCM5 ESC INSP DENIED
Corrective Action Required
04/21/2025
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION.
Occupancy Inspection - Codes Residential Not Ready 4/21/2025 4/21/2025 04/21/2025
Misc
Corrective Action Required
04/21/2025
Inspection denied No erosion control in place and no access to garage available
Erosion Control Inspection Residential Partial 4/22/2025 04/22/2025
Miscellaneous Correction
Informational
04/21/2025
Erosion control is in place at the time of this inspection
DCM5 ESC INSP DENIED
Resolved
04/22/2025
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION.
Misc
Corrective Action Required
04/22/2025
Debris pile needs removed
Plot Plan Inspection Failed 4/22/2025 04/22/2025
Misc
Corrective Action Required
04/22/2025
Remove debris piles and finish grade
Occupancy Inspection - Codes Residential Failed 4/22/2025 4/22/2025 04/22/2025
Misc
Resolved
04/22/2025
Inspection denied No erosion control in place and no access to garage available
Misc
Corrective Action Required
04/22/2025
-add gravel to water meter pit -splash blocks need installed -tracer wire needs to be at grade -dishwasher outlet to be gfci protected -bottom track bracket on large garage door must be within 18” of the floor - need handrail into basement - Sump discharge to 36” away from foundation - Needs final grade and sod - Debris pile needs to be removed - Fall protection from front porch needed if final grade is greater than 30” below porch - Cut down water shutoff in front yard to grade
Erosion Control Inspection Residential Partial 4/24/2025 04/24/2025
Miscellaneous Correction
Informational
04/22/2025
Erosion control is in place at the time of this inspection
Misc
Corrective Action Required
04/22/2025
Debris pile needs removed
Occupancy Inspection - Codes Residential Ready for Temp CO 4/24/2025 4/24/2025 04/24/2025
Misc
Corrective Action Required
04/22/2025
-add gravel to water meter pit -splash blocks need installed -tracer wire needs to be at grade - Sump discharge to 36” away from foundation - Needs final grade and sod - Debris pile needs to be removed - Fall protection from front porch needed if final grade is greater than 30” below porch - Cut down water shutoff in front yard to grade - Pay all fees
Documents & Images
Date Uploaded File Type Document Name
10/25/2024 Permit Codes Residential Plan Review
10/28/2024 HT #180 - PERMIT APP
10/28/2024 Approved Plans APPROVED PLANS
10/28/2024 Plot Plan APPROVED PLOT PLAN
10/28/2024 Approved Plans APPROVED TRUSS LAYOUT
10/28/2024 Approved Plans APPROVED TRUSS PACKAGE
10/28/2024 Permit Codes Residential Plan Review
10/29/2024 Permit DS Building Permit
10/29/2024 Receipt Receipt for transaction:2024-008615
11/17/2024 1625 SW Arborway Terr LSMO Footing Inspection Report 11-16-24
12/02/2024 Letter INSPECTION SUMMARY
12/02/2024 Letter INSPECTION SUMMARY
12/12/2024 Letter INSPECTION SUMMARY
12/12/2024 Letter INSPECTION SUMMARY
12/27/2024 Letter INSPECTION SUMMARY
01/23/2025 Letter INSPECTION SUMMARY
01/23/2025 Letter INSPECTION SUMMARY
02/07/2025 Plans TRUSS REPAIR LETTER
02/10/2025 Letter INSPECTION SUMMARY
02/10/2025 Letter INSPECTION SUMMARY
02/10/2025 Letter INSPECTION SUMMARY
02/12/2025 Letter INSPECTION SUMMARY
02/12/2025 Letter INSPECTION SUMMARY
02/14/2025 Letter INSPECTION SUMMARY
02/14/2025 Letter INSPECTION SUMMARY
02/18/2025 Letter INSPECTION SUMMARY
02/24/2025 Letter INSPECTION SUMMARY
02/24/2025 Letter INSPECTION SUMMARY
02/26/2025 Letter INSPECTION SUMMARY
02/27/2025 Letter INSPECTION SUMMARY
04/03/2025 Letter INSPECTION SUMMARY
04/07/2025 Letter INSPECTION SUMMARY
04/07/2025 Receipt Receipt for transaction:2025-002099
04/18/2025 Letter INSPECTION SUMMARY
04/21/2025 Letter INSPECTION SUMMARY
04/21/2025 Letter INSPECTION SUMMARY
04/22/2025 Letter INSPECTION SUMMARY
04/22/2025 Letter INSPECTION SUMMARY
04/22/2025 Letter INSPECTION SUMMARY
04/24/2025 Certificate/License Codes Temporary Certificate of Occupancy
04/24/2025 Receipt Receipt for transaction:2025-002561
04/24/2025 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home