Summary
PRRES20245413
Building Permit - Residential
Temporary Occupancy
DOMAIN TIMBERLAKE MULTISTATE LLC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - UNCOVERED DECK - ROOF TRUSSES STOP WORK ORDER generated on 11/27/2024 12:00 AM by username 'Mark Harding'. STOP WORK ORDER removed on 12/03/2024 12:00 AM by username 'Mitchell Schwarz'.
10/14/2024
10/15/2024
04/12/2025
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
DOMAIN TIMBERLAKE MULTISTATE LLC, Address:590 MADISON AVE FL 13TH  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
BRUCER@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sanitary Sewer Development Fee $2,285.00 $2,285.00 Paid 10/15/2024
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 10/15/2024
7232302-Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 10/15/2024
8331401-Water Tap Fee $3,973.00 $3,973.00 Paid 10/15/2024
8350015-Water Meter Fee $748.03 $748.03 Paid 10/15/2024
9110078-Valuation Fee New Single Family $2,142.76 $2,142.76 Paid 10/15/2024
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 05/07/2025
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 05/07/2025
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 05/07/2025
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 05/07/2025
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 05/15/2025
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 05/15/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Pending
Plot Plan Inspection Pending
Misc
Corrective Action Required
05/12/2025
As graded plot plan needed
Occupancy Inspection - Codes Residential Pending 6/14/2025
Misc
Corrective Action Required
05/15/2025
3211 SW Arboridge circle - as graded plot plan needed - Final driveway inspection needed - Seal top of AC disconnect - Install sod, splash blocks and sump discharge 36” from house - Bottom garage door brackets required to be within 18” of floor - Install 2, 1/2” thru bolts or approved bracket on the two outer posts of upper stair landing -
Misc
Corrective Action Required
05/15/2025
3211 SW Arboridge circle - as graded plot plan needed - Final driveway inspection needed - Seal top of AC disconnect - Install sod, splash blocks and sump discharge 36” from house - Install 2, 1/2” thru bolts or approved bracket on the two outer posts of upper stair landing - Install missing spindle -
Sewer Service Inspection - R Passed 11/12/2024 11/12/2024 11/12/2024
Water Service Inspection - R Passed 11/14/2024 11/14/2024 11/14/2024
Underslab Plumbing Inspection - Residential Failed - Stop Work 11/27/2024 11/27/2024 11/27/2024
Misc
Corrective Action Required
11/27/2024
no footing uploaded or inspected. underslab denied
Footing Inspection - Residential Passed 12/3/2024 12/03/2024
Underslab Plumbing Inspection - Residential Failed 12/4/2024 12/4/2024 12/04/2024
Misc
Corrective Action Required
11/27/2024
Clean trash and debris from under slab area for inspection
Underslab Plumbing Inspection - Residential Passed 12/6/2024 12/6/2024 12/06/2024
Misc
Resolved
12/06/2024
Clean trash and debris from under slab area for inspection
Erosion Control Inspection Residential Failed 1/23/2025 1/23/2025 01/23/2025
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
01/23/2025
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -Re establish erosion control methods at rear of property
All Rough Inspection - Residential Failed 1/23/2025 1/23/2025 01/23/2025
Misc
Corrective Action Required
01/23/2025
Garage PFH only approved to cover
All Rough Inspection - Residential Not Ready 2/25/2025 2/25/2025 02/25/2025
Misc
Corrective Action Required
01/23/2025
Garage PFH only approved to cover
Misc
Corrective Action Required
02/25/2025
Inspection denied, no address posted
Gas Service Inspection - Residential Failed 2/25/2025 2/25/2025 02/25/2025
Misc
Corrective Action Required
02/25/2025
Inspection denied no address posted
Electrical Service Inspection Failed 2/25/2025 2/25/2025 02/25/2025
Misc
Corrective Action Required
02/25/2025
Inspection denied, no address posted.
All Rough Inspection - Residential Not Ready 2/26/2025 2/26/2025 02/26/2025
Misc
Resolved
02/26/2025
Garage PFH only approved to cover
Misc
Resolved
02/26/2025
Inspection denied, no address posted
Misc
Corrective Action Required
02/26/2025
Provide complete truss packet for inspection of trusses(missing layout) -address holes drilled in floor joist above garage drilled closer than 2” to each other and/or bottom of joist -fireblock rear garage wall into furr down -fire blocking chases into garage furr down/ceiling space -nail plate under header at pfh to code/desgin -anchor bolts at N garage corner to be in the middle 1/3 of sill plate -provide attic access for single car garage -fireblock garage entry closet wall space to ceiling space -address double 2x10 above bath 4 entry over notched/drillled -strap top plate at bed 5 closet exterior wall where lapped less than 24” -address multiple holes drilled through top of lvl above kitchen refrigerator -address holes drilled closer than 2” to one another for dwv and pex above great room near hvac/plumbing chase -seal bottom plate penetration at hvac chase near dining -cspf at dining room and bed 2 not framed to cspf specifications -front porch roof framing covered without inspection -provide protection at top plate for dryer vent -missing hold down devices at stairs -anchor steel column at stairs -secure SE cable within 12” of disconnect -minimum 3 studs at each exterior wall corner in basement -repair broken duct work in basement near furnace -use approved method of connection to ufer ground -deck not constructed at time of inspection -
Electrical Service Inspection Failed 2/26/2025 2/26/2025 02/26/2025
Misc
Resolved
02/26/2025
Inspection denied, no address posted.
Misc
Corrective Action Required
02/26/2025
use approved method of connection to ufer ground
Gas Service Inspection - Residential Passed 2/26/2025 2/26/2025 02/26/2025
Misc
Resolved
02/26/2025
Inspection denied no address posted
All Rough Inspection - Residential Not Ready 3/10/2025 3/10/2025 03/10/2025
Misc
Corrective Action Required
02/26/2025
Erosion control not in compliance, -maintain and spread gravel filter -missing erosion control at front of lot. Provide complete truss packet for inspection of trusses(missing layout) -address holes drilled in floor joist above garage drilled closer than 2” to each other and/or bottom of joist -fireblock rear garage wall into furr down -fire blocking chases into garage furr down/ceiling space -nail plate under header at pfh to code/desgin -anchor bolts at N garage corner to be in the middle 1/3 of sill plate -provide attic access for single car garage -fireblock garage entry closet wall space to ceiling space -address double 2x10 above bath 4 entry over notched/drillled -strap top plate at bed 5 closet exterior wall where lapped less than 24” -address multiple holes drilled through top of lvl above kitchen refrigerator -address holes drilled closer than 2” to one another for dwv and pex above great room near hvac/plumbing chase -seal bottom plate penetration at hvac chase near dining -cspf at dining room and bed 2 not framed to cspf specifications -front porch roof framing covered without inspection -provide protection at top plate for dryer vent -missing hold down devices at stairs -anchor steel column at stairs -secure SE cable within 12” of disconnect -minimum 3 studs at each exterior wall corner in basement -repair broken duct work in basement near furnace -use approved method of connection to ufer ground -deck not constructed at time of inspection
Electrical Service Inspection Failed 3/10/2025 3/10/2025 03/10/2025
Misc
Corrective Action Required
02/26/2025
Inspection denied erosion control not in compliance use approved method of connection to ufer ground
Erosion Control Inspection Residential Failed 3/10/2025 3/10/2025 03/10/2025
DCM2 ESC DEFICIENT INSTALLATION
Resolved
03/10/2025
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -Re establish erosion control methods at front of lot -
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
03/10/2025
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM5 ESC INSP DENIED
Corrective Action Required
03/10/2025
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. -maintain gravel entrance -maintain erosion control missing at front of lot
All Rough Inspection - Residential Not Ready 3/11/2025 3/11/2025 03/11/2025
Misc
Corrective Action Required
03/10/2025
Erosion control not in compliance, -maintain and spread gravel filter -missing erosion control at front of lot. Gravel filter still not addressed. 03/11/25 Provide complete truss packet for inspection of trusses(missing layout) -address holes drilled in floor joist above garage drilled closer than 2” to each other and/or bottom of joist -fireblock rear garage wall into furr down -fire blocking chases into garage furr down/ceiling space -nail plate under header at pfh to code/desgin -anchor bolts at N garage corner to be in the middle 1/3 of sill plate -provide attic access for single car garage -fireblock garage entry closet wall space to ceiling space -address double 2x10 above bath 4 entry over notched/drillled -strap top plate at bed 5 closet exterior wall where lapped less than 24” -address multiple holes drilled through top of lvl above kitchen refrigerator -address holes drilled closer than 2” to one another for dwv and pex above great room near hvac/plumbing chase -seal bottom plate penetration at hvac chase near dining -cspf at dining room and bed 2 not framed to cspf specifications -front porch roof framing covered without inspection -provide protection at top plate for dryer vent -missing hold down devices at stairs -anchor steel column at stairs -secure SE cable within 12” of disconnect -minimum 3 studs at each exterior wall corner in basement -repair broken duct work in basement near furnace -use approved method of connection to ufer ground -deck not constructed at time of inspection
Electrical Service Inspection Failed 3/11/2025 3/11/2025 03/11/2025
Misc
Corrective Action Required
03/10/2025
Inspection denied erosion control not in compliance Still not in compliance use approved method of connection to ufer ground
All Rough Inspection - Residential Failed 3/12/2025 3/12/2025 03/12/2025
Misc
Corrective Action Required
03/11/2025
-address holes drilled in floor joist above garage drilled closer than 2” to each other and/or bottom of joist -protect wires within 6’ of attic access in garage -address double 2x10 above bath 4 entry over notched/drillled(provide engineering for fix) -address multiple holes drilled through top of lvl above kitchen refrigerator (have engineer address fix) -address holes drilled closer than 2” to one another for dwv and pex above great room near hvac/plumbing chase -cspf at dining room and bed 2 not framed to cspf specifications -front porch roof framing covered without inspection -provide protection at top plate for dryer vent -move stair hold down devices to correct location -minimum 3 studs at each exterior wall corner in basement tying walls together -repair broken dwv at furnace -deck not constructed at time of inspection
Electrical Service Inspection Passed 3/12/2025 3/12/2025 03/12/2025
Misc
Resolved
03/12/2025
Inspection denied erosion control not in compliance Still not in compliance use approved method of connection to ufer ground
All Rough Inspection - Residential Failed 3/19/2025 3/19/2025 03/19/2025
Misc
Corrective Action Required
03/12/2025
-minimum 3 studs at each exterior wall corner in basement tying walls together -deck not constructed at time of inspection
All Rough Inspection - Residential Passed 3/20/2025 3/20/2025 03/20/2025
Misc
Corrective Action Required
03/19/2025
-deck not constructed at time of inspection
Piers/Caissons Inspection - Residential Failed 4/3/2025 4/3/2025 04/03/2025
Misc
Corrective Action Required
04/03/2025
N most pure okay to pour. S pier not to depth
Piers/Caissons Inspection - Residential Passed 4/21/2025 4/21/2025 04/21/2025
Misc
Resolved
04/21/2025
N most pure okay to pour. S pier not to depth
Driveway Inspection Partial 4/21/2025 4/21/2025 04/21/2025
Misc
Informational
04/21/2025
4-21-25 Dustin A, Dw has been formed and compacted, Approved to pour
Driveway Inspection Partial 5/5/2025 5/5/2025 05/05/2025
Misc
Informational
04/21/2025
4-21-25 Dustin A, Dw has been formed and compacted, Approved to pour 05-05-25 Jamie S, DW slope is in compliance with city standards.
Erosion Control Inspection Residential Failed 05/07/2025
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
03/10/2025
5/7/25 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -Provide erosion control methods at perimeter and protect storm inlet in back
DCM5 ESC INSP DENIED
Resolved
05/07/2025
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. -maintain gravel entrance -maintain erosion control missing at front of lot
Occupancy Inspection - Codes Residential Failed 5/7/2025 5/7/2025 05/07/2025
Misc
Corrective Action Required
05/07/2025
-Inspection denied due to deficient erosion control. Provide erosion control at perimeter and protect storm inlet before scheduling further inspections
Occupancy Inspection - Codes Residential Not Ready 5/9/2025 5/9/2025 05/09/2025
Misc
Corrective Action Required
05/07/2025
-Inspection denied due to deficient erosion control. Provide erosion control at perimeter and protect storm inlet before scheduling further inspections
Misc
Corrective Action Required
05/09/2025
Inspection denied, no erosion control in place. Provide perimeter protection and protect field inlet before scheduling any more inspections
Erosion Control Inspection Residential Partial 5/12/2025 5/12/2025 05/12/2025
DCM3 ESC REQUIRED 2 DAY
Resolved
05/12/2025
5/7/25 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -Provide erosion control methods at perimeter and protect storm inlet in back
Plot Plan Inspection Failed 5/12/2025 05/12/2025
Misc
Corrective Action Required
05/12/2025
As graded plot plan needed
Occupancy Inspection - Codes Residential Failed 5/12/2025 5/12/2025 05/12/2025
Misc
Resolved
05/12/2025
-Inspection denied due to deficient erosion control. Provide erosion control at perimeter and protect storm inlet before scheduling further inspections
Misc
Resolved
05/12/2025
Inspection denied, no erosion control in place. Provide perimeter protection and protect field inlet before scheduling any more inspections
Misc
Corrective Action Required
05/12/2025
3211 SW Arboridge circle - as graded plot plan needed - Final driveway inspection needed - Seal top of AC disconnect - Install sod, splash blocks and sump discharge 36” from house - Bottom garage door brackets required to be within 18” of floor - Install 2, 1/2” thru bolts or approved bracket on the two outer posts of upper stair landing - Install missing spindle -
Driveway Inspection Passed 5/13/2025 5/13/2025 05/13/2025
Misc
Informational
05/05/2025
4-21-25 Dustin A, Dw has been formed and compacted, Approved to pour 05-05-25 Jamie S, DW slope is in compliance with city standards.
Occupancy Inspection - Codes Residential Failed 5/14/2025 5/14/2025 05/14/2025
Misc
Corrective Action Required
05/12/2025
3211 SW Arboridge circle - as graded plot plan needed - Final driveway inspection needed - Seal top of AC disconnect - Install sod, splash blocks and sump discharge 36” from house - Bottom garage door brackets required to be within 18” of floor - Install 2, 1/2” thru bolts or approved bracket on the two outer posts of upper stair landing -
Occupancy Inspection - Codes Residential Ready for Temp CO 5/15/2025 05/15/2025
Misc
Corrective Action Required
05/14/2025
3211 SW Arboridge circle - as graded plot plan needed - Final driveway inspection needed - Seal top of AC disconnect - Install sod, splash blocks and sump discharge 36” from house - Bottom garage door brackets required to be within 18” of floor - Install 2, 1/2” thru bolts or approved bracket on the two outer posts of upper stair landing -
Misc
Corrective Action Required
05/15/2025
3211 SW Arboridge circle - as graded plot plan needed - Final driveway inspection needed - Seal top of AC disconnect - Install sod, splash blocks and sump discharge 36” from house - Install 2, 1/2” thru bolts or approved bracket on the two outer posts of upper stair landing - Install missing spindle -
Documents & Images
Date Uploaded File Type Document Name
10/14/2024 Application Form HT #189 - PERMIT APP
10/14/2024 Approved Plans APPROVED PLANS
10/14/2024 Approved Plans APPROVED TRUSS LAYOUT
10/14/2024 Approved Plans APPROVED TRUSS PACKAGE
10/14/2024 Permit Codes Residential Plan Review
10/15/2024 Permit Codes Residential Plan Review
10/15/2024 Plot Plan APPROVED PLOT PLAN
10/15/2024 Permit DS Building Permit
10/15/2024 Receipt Receipt for transaction:2024-008318
10/24/2024 Approved Plans APPROVED REVISED PLANS
11/12/2024 Letter INSPECTION SUMMARY
11/14/2024 Letter INSPECTION SUMMARY
11/26/2024 3RD Party Insp Report THIRD PARTY FOOTING INSPECTION
11/27/2024 Letter Stop Work Order
12/04/2024 Letter INSPECTION SUMMARY
12/04/2024 Letter INSPECTION SUMMARY
12/06/2024 Letter INSPECTION SUMMARY
01/23/2025 Letter INSPECTION SUMMARY
01/23/2025 Letter INSPECTION SUMMARY
02/25/2025 Letter INSPECTION SUMMARY
02/25/2025 Letter INSPECTION SUMMARY
02/25/2025 Letter INSPECTION SUMMARY
02/26/2025 Letter INSPECTION SUMMARY
02/26/2025 Letter INSPECTION SUMMARY
02/26/2025 Letter INSPECTION SUMMARY
03/10/2025 Letter INSPECTION SUMMARY
03/10/2025 Letter INSPECTION SUMMARY
03/10/2025 Letter INSPECTION SUMMARY
03/11/2025 Letter INSPECTION SUMMARY
03/11/2025 Letter INSPECTION SUMMARY
03/12/2025 Letter INSPECTION SUMMARY
03/12/2025 Letter INSPECTION SUMMARY
03/19/2025 189 Hawthorn Ridge - BWP HOLD DOWN RETROFIT
03/19/2025 Letter INSPECTION SUMMARY
03/20/2025 Letter INSPECTION SUMMARY
04/03/2025 Letter INSPECTION SUMMARY
04/21/2025 Letter INSPECTION SUMMARY
04/21/2025 Letter INSPECTION SUMMARY
05/05/2025 Letter INSPECTION SUMMARY
05/07/2025 Receipt Receipt for transaction:2025-002938
05/07/2025 Letter INSPECTION SUMMARY
05/07/2025 Letter INSPECTION SUMMARY
05/09/2025 Letter INSPECTION SUMMARY
05/12/2025 Letter INSPECTION SUMMARY
05/12/2025 Letter INSPECTION SUMMARY
05/12/2025 Letter INSPECTION SUMMARY
05/13/2025 Letter INSPECTION SUMMARY
05/14/2025 Letter INSPECTION SUMMARY
05/15/2025 Letter INSPECTION SUMMARY
05/15/2025 Certificate/License Codes Temporary Certificate of Occupancy
05/15/2025 Receipt Receipt for transaction:2025-003363
06/05/2025 HT #189 - TCO Extension 6_5_25
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home