PRRES20242381
Building Permit - Residential
Notice of Violation
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINISHED BASEMENT - COVERED DECK - ROOF TRUSSES STOP WORK ORDER generated on 06/14/2024 12:00 AM by username 'Robb Popp'. STOP WORK ORDER removed on 06/18/2024 12:00 AM by username 'Robb Popp'. STOP WORK ORDER generated on 12/03/2024 12:00 AM by username 'Robb Popp'.
05/13/2024
05/21/2024
11/10/2024
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
BRUCER@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 05/21/2024
Right of Way Permit Fee $85.00 $85.00 Paid 05/21/2024
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 05/21/2024
Water Tap Fee $3,760.00 $3,760.00 Paid 05/21/2024
Water Meter Fee $680.46 $680.46 Paid 05/21/2024
Valuation Fee New Single Family $2,338.80 $2,338.80 Paid 05/21/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 12/12/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 01/22/2025
Temporary Occupancy Fee $50.00 $50.00 Paid 02/11/2025
Temporary Occupancy Fee $50.00 $50.00 Paid 03/11/2025
Temporary Occupancy Fee $50.00 $50.00 Paid 04/11/2025
Outstanding Fees Amount Paid Owing Date Paid
Not Ready Inspection Fee $75.00 $0.00 $75.00 Not Paid


$75.00    Add Fees to My Cart
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Plot Plan Inspection Pending
Erosion Control Inspection Residential Pending
Miscellaneous Correction
Corrective Action Required
04/16/2025
3/27/25 Maintain storm inlet and perimeter protection -Remove silt and debris from inlet, replace damaged, worn gutter buddy and install with cinder blocks separating filter from inlet -Complete erosion control methods at perimeter
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
04/16/2025
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. 4/16/25 Maintain storm inlet and perimeter protection -Remove silt and debris from inlet, replace damaged, worn gutter buddy and install with cinder blocks separating filter from inlet -Complete erosion control methods at perimeter **Notice of Violation issued
Occupancy Inspection - Codes Residential Pending
Miscellaneous Correction
Corrective Action Required
04/18/2025
-Deck stair landing is not installed -Outside AC unit is not installed -Seal gap in siding to foundation wall along the east side -Front porch soffit is not complete -Sod, splash pads and sump pump extension are not installed -Plot plan could not be completed due to snow on the ground -Sidewalk inspection must pass -Re establish erosion control at front of lot
Miscellaneous Correction
Corrective Action Required
04/18/2025
4/18/25 -TCO extension request denied. House is in NOV status and still has no erosion control. No further inspections, or extensions will be issued or performed until erosion control has been addressed.
Sidewalk Inspection Pending 11/26/2024
Misc
Corrective Action Required
11/20/2024
11-19-24 Dustin A, Sw formed and compacted. Slopes are in compliance. There is areas in sw where gravel is to deficient. Will need to be dug deeper. Will need another pre pour inspection. 11/20/24 JMJ (Passed Per Inspection) Contractor correct the issue of deficient gravel and was approved for pour. I advised the contractor to call me when were going to pour, canceled because windy weather conditions.
Erosion Control Inspection Residential Failed - Stop Work 06/14/2024
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
06/14/2024
6/14/24 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -NO EROSION CONTROL PRESENT AT SITE. BMPs ARE REQUIRED TO BE INSTALLED AND MAINTAINED UNTIL PERMANANT VEGETATION IS PROVIDED. NO INSPECTIONS WILL BE PERFORMED UNTIL IN COMPLIANCE
Footing Inspection - Residential Failed - Stop Work 6/14/2024 06/14/2024
Misc
Corrective Action Required
06/14/2024
6/14/24 -FOOTING HAS BEEN POURED WITHOUT INSPECTION. NO EROSION CONTROL METHODS ARE IN PLACE. STOP WORK ISSUED
Footing Inspection - Residential Passed 6/18/2024 6/18/2024 06/18/2024
Misc
Informational
06/18/2024
Footing approved by David Ainsworth on 6/13/24
Erosion Control Inspection Residential Failed 06/18/2024
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
06/14/2024
6/18/24 -Post site address *BMPs in compliance at time of inspection
Sewer Service Inspection - R Passed 6/25/2024 06/25/2024
Erosion Control Inspection Residential Partial 6/25/2024 06/25/2024
DCM3 ESC REQUIRED 2 DAY
Informational
06/25/2024
*BMPs in compliance at time of inspection
Underslab Plumbing Inspection - Residential Passed 6/26/2024 6/26/2024 06/26/2024
Water Service Inspection - R Partial 6/26/2024 6/26/2024 06/26/2024
Misc
Corrective Action Required
06/26/2024
- Partial, poly out of foundation 45'.
Water Service Inspection - R Passed 6/27/2024 6/27/2024 06/27/2024
Misc
Resolved
06/27/2024
- Partial, poly out of foundation 45'.
Erosion Control Inspection Residential Failed 8/21/2024 8/21/2024 08/21/2024
DCM3 ESC REQUIRED 2 DAY
Resolved
08/21/2024
*BMPs in compliance at time of inspection
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
08/21/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -Restore silt fence at front of lot
All Rough Inspection - Residential Failed 8/21/2024 8/21/2024 08/21/2024
Misc
Corrective Action Required
08/21/2024
8/21/24 partial framing inspection only: -Exterior portal framing ok to cover -Back covered deck has already been covered. Expose all framing for inspection
Erosion Control Inspection Residential Failed 10/17/2024 10/17/2024 10/17/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
08/21/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -Restore silt fence at front of lot
Electrical Service Inspection Passed 10/17/2024 10/17/2024 10/17/2024
Gas Service Inspection - Residential Failed 10/17/2024 10/17/2024 10/17/2024
Misc
Corrective Action Required
10/17/2024
-Bond metallic gas line -Provide pressure test
All Rough Inspection - Residential Not Ready 10/17/2024 10/17/2024 10/17/2024
Misc
Corrective Action Required
08/21/2024
Not ready for all rough. List is incomplete. Correct the following items before rescheduling: -Correct failed erosion control -Required 5/8” anchor bolt at PFH to b in middle third of plate -Nail exterior corners min 12” oc -Anchor bolts at garage to be in middle third of plate -Fireblock ceiling line at fur down in garage-missing near HVAC chase -Corner stud at single car bay notched greater than 25% -Provide attic access for trusses in garage/ bed 5 -Missing truss screws in garage throughout -Missing H2.5s at GT locations -Strap both sides of overbored top plates in garage load bearing wall -Fireblock 2nd floor traps in garage -Fireblock dead space at garage/ bath 4 -Exterior wall and interior load bearing walls not connected at top plate or intersecting studs -Missing truss hold downs at hip trusses on covered deck -Bond gas line -Provide gas pressure test -Fireblock fur out walls in stairs and basement
Erosion Control Inspection Residential Partial 10/29/2024 10/29/2024 10/29/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
10/17/2024
Erosion control in compliance
Gas Service Inspection - Residential Failed 10/29/2024 10/29/2024 10/29/2024
Misc
Corrective Action Required
10/17/2024
-Provide pressure test. No pressure
All Rough Inspection - Residential Failed 10/29/2024 10/29/2024 10/29/2024
Misc
Corrective Action Required
10/17/2024
-Nail exterior corners min 12” oc -Missing H2.5s at GT locations **Check spec of screws. Some screws have higher pull out rating -Strap both sides of overbored top plates in garage load bearing wall -Fireblock dead space at garage/ bath 4 -Exterior wall and interior load bearing walls not connected at top plate or intersecting studs -Install hanger for B5 and TJC37 for J16 and J33 -Install roof penetrations flashing -Complete kitchen hood duct soffit and fb as required -Protect dryer duct at wall top plate -Tie down GT C17 -Strap 2nd fl exterior wall top plates where bored more than 50% -Complete electrical to stair light -Fb basement wall space vertically at ten ft or less intervals; fb wall near wet bar from soffit; fb wall from soffit adjacent to stair wall -Install nail plate for 3” pvc -Fill in void at walkout door strike plate side with solid wood per security code -Secure csst gas line min 3” above framing surface. Where the gas line is secured within 3” of framing surface, provide protection per manufacturer’s instructions -Anchor basement sill plate 3.5”-12” from break -Provide vent for gas fuel water heater -Provide combustion air openings per code for water heater -Provide (3)2x10 in mech rm per plan -Gas test fails **OK TO INSULATE
Erosion Control Inspection Residential Failed 11/6/2024 11/6/2024 11/06/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
10/29/2024
Clean debris from street, remove loose trash from site
All Rough Inspection - Residential Failed 11/6/2024 11/6/2024 11/06/2024
Misc
Corrective Action Required
10/29/2024
-Nail exterior corners min 12” oc -Missing H2.5s at GT locations **Check spec of screws. Some screws have higher pull out rating -Strap both sides of overbored top plates in garage load bearing wall -Fireblock dead space at garage/ bath 4 -Exterior wall and interior load bearing walls not connected at top plate or intersecting studs -Install hanger for B5 and TJC37 for J16 and J33 -Install roof penetrations flashing -Complete kitchen hood duct soffit to and fb as required -Protect dryer duct at wall top plate -Tie down GT C17 -Strap 2nd fl exterior wall top plates where bored more than 50% -Complete electrical to stair light -Fb basement wall space vertically at ten ft or less intervals; fb wall near wet bar from soffit; fb wall from soffit adjacent to stair wall -Install nail plate for 3” pvc -Fill in void at walkout door strike plate side with solid wood per security code -Secure csst gas line min 3” above framing surface. Where the gas line is secured within 3” of framing surface, provide protection per manufacturer’s instructions -Anchor basement sill plate 3.5”-12” from break -Provide vent for gas fuel water heater -Provide combustion air openings per code for water heater -Provide (3)2x10 in mech rm per plan -Gas test fails **OK TO INSULATE
Misc
Corrective Action Required
11/06/2024
11/6/24 -No access
Gas Service Inspection - Residential Passed 11/8/2024 11/08/2024
Misc
Resolved
11/08/2024
-Provide pressure test. No pressure
All Rough Inspection - Residential Passed 11/8/2024 11/8/2024 11/08/2024
Misc
Resolved
11/08/2024
-Nail exterior corners min 12” oc -Missing H2.5s at GT locations **Check spec of screws. Some screws have higher pull out rating -Strap both sides of overbored top plates in garage load bearing wall -Fireblock dead space at garage/ bath 4 -Exterior wall and interior load bearing walls not connected at top plate or intersecting studs -Install hanger for B5 and TJC37 for J16 and J33 -Install roof penetrations flashing -Complete kitchen hood duct soffit to and fb as required -Protect dryer duct at wall top plate -Tie down GT C17 -Strap 2nd fl exterior wall top plates where bored more than 50% -Complete electrical to stair light -Fb basement wall space vertically at ten ft or less intervals; fb wall near wet bar from soffit; fb wall from soffit adjacent to stair wall -Install nail plate for 3” pvc -Fill in void at walkout door strike plate side with solid wood per security code -Secure csst gas line min 3” above framing surface. Where the gas line is secured within 3” of framing surface, provide protection per manufacturer’s instructions -Anchor basement sill plate 3.5”-12” from break -Provide vent for gas fuel water heater -Provide combustion air openings per code for water heater -Provide (3)2x10 in mech rm per plan -Gas test fails **OK TO INSULATE
Misc
Resolved
11/08/2024
11/6/24 -No access
Driveway Inspection Partial 11/19/2024 11/19/2024 11/19/2024
Misc
Informational
11/19/2024
11-19-24 Dustin A,Dw is formed and compacted. Will need to maintain ADA compliance. Approved to pour
Sidewalk Inspection Failed 11/19/2024 11/19/2024 11/19/2024
Misc
Corrective Action Required
11/19/2024
11-19-24 Dustin A, Sw formed and compacted. Slopes are in compliance. There is areas in sw where gravel is to deficient. Will need to be dug deeper. Will need another pre pour inspection.
Sidewalk Inspection Partial 11/20/2024
Misc
Corrective Action Required
11/19/2024
11-19-24 Dustin A, Sw formed and compacted. Slopes are in compliance. There is areas in sw where gravel is to deficient. Will need to be dug deeper. Will need another pre pour inspection. 11/20/24 JMJ (Passed Per Inspection) Contractor correct the issue of deficient gravel and was approved for pour. I advised the contractor to call me when were going to pour, canceled because windy weather conditions.
Erosion Control Inspection Residential Failed 11/26/2024
DCM2 ESC DEFICIENT INSTALLATION
Resolved
11/26/2024
-Provide ESC methods at perimeter, Clean debris from street, remove loose trash from site
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
11/26/2024
11/26/24 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -Provide ESC methods at perimeter, Clean debris from street, remove loose trash from site
Driveway Inspection Passed 11/27/2024 11/27/2024 11/27/2024
Misc
Informational
11/19/2024
11-19-24 Dustin A,Dw is formed and compacted. Will need to maintain ADA compliance. Approved to pour 11-27-24 Dustin A, DW is poured to city specs and slopes are in compliance. Pass
Erosion Control Inspection Residential Failed - Stop Work 12/3/2024 12/3/2024 12/03/2024
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
11/26/2024
11/26/24 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -Provide ESC methods at perimeter, Clean debris from street, remove loose trash from site 12/3/24 -No change. Stop Work issued
Erosion Control Inspection Residential Failed - Stop Work 12/09/2024
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
12/03/2024
11/26/24 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -Provide ESC methods at perimeter, Clean debris from street, remove loose trash from site 12/3/24 -No change. Stop Work issued 12/9/24 -Still no change. photos have been uploaded to portal. 10 day notice of violation will be issued
Occupancy Inspection - Codes Residential Failed 1/16/2025 1/16/2025 01/16/2025
Miscellaneous Correction
Corrective Action Required
01/16/2025
Fire block gap above interior overhead garage doors at ceiling Garage to house steps need a guard rail installed Kitchen hood vent is not installed Receptacle covers missing throughout Remove smoke dust covers throughout Utility room attic access hatch is missing Bottom stair landing to the basement does not have the required 36 inches of travel distance Basement refrigerator receptacle needs to be GFCI protected Vent fan in basement bathroom is not installed Patio stair landing is not installed Guard rail is needed on front porch west side Outside AC unit is not installed Seal gap in siding to foundation wall along the east side Front porch soffit is not complete Sod, splash pads and sump pump extension are not installed Plot plan could not be completed due to snow on the ground Sidewalk inspection must pass
Occupancy Inspection - Codes Residential Failed 1/21/2025 1/21/2025 01/21/2025
Miscellaneous Correction
Corrective Action Required
01/16/2025
-Receptacle covers missing at living room -Basement refrigerator receptacle needs to be GFCI protected -Vent fan in basement bathroom is not installed -Deck stair landing is not installed -Outside AC unit is not installed -Seal gap in siding to foundation wall along the east side -Front porch soffit is not complete -Sod, splash pads and sump pump extension are not installed -Plot plan could not be completed due to snow on the ground -Sidewalk inspection must pass -Re establish erosion control at front of lot
Occupancy Inspection - Codes Residential Ready for Temp CO 1/22/2025 1/22/2025 01/22/2025
Miscellaneous Correction
Corrective Action Required
01/21/2025
-Deck stair landing is not installed -Outside AC unit is not installed -Seal gap in siding to foundation wall along the east side -Front porch soffit is not complete -Sod, splash pads and sump pump extension are not installed -Plot plan could not be completed due to snow on the ground -Sidewalk inspection must pass -Re establish erosion control at front of lot
Erosion Control Inspection Residential Failed 02/05/2025
DCM3 ESC REQUIRED 2 DAY
Resolved
02/05/2025
Miscellaneous Correction
Corrective Action Required
02/05/2025
Maintain storm inlet -Remove silt and debris from inlet, replace damaged, worn gutter buddy and install with cinder blocks separating filter from inlet
Erosion Control Inspection Residential Failed - Stop Work 02/11/2025
Miscellaneous Correction
Corrective Action Required
02/05/2025
Maintain storm inlet -Remove silt and debris from inlet, replace damaged, worn gutter buddy and install with cinder blocks separating filter from inlet
Occupancy Inspection - Codes Residential Ready for Temp CO 02/11/2025
Miscellaneous Correction
Corrective Action Required
01/22/2025
-Deck stair landing is not installed -Outside AC unit is not installed -Seal gap in siding to foundation wall along the east side -Front porch soffit is not complete -Sod, splash pads and sump pump extension are not installed -Plot plan could not be completed due to snow on the ground -Sidewalk inspection must pass -Re establish erosion control at front of lot
Occupancy Inspection - Codes Residential Ready for Temp CO 03/11/2025
Miscellaneous Correction
Corrective Action Required
02/11/2025
-Deck stair landing is not installed -Outside AC unit is not installed -Seal gap in siding to foundation wall along the east side -Front porch soffit is not complete -Sod, splash pads and sump pump extension are not installed -Plot plan could not be completed due to snow on the ground -Sidewalk inspection must pass -Re establish erosion control at front of lot
Erosion Control Inspection Residential Failed 03/18/2025
Miscellaneous Correction
Corrective Action Required
02/11/2025
3/18/25 Maintain storm inlet and perimeter protection -Remove silt and debris from inlet, replace damaged, worn gutter buddy and install with cinder blocks separating filter from inlet -Complete erosion control methods at perimeter
Erosion Control Inspection Residential Failed 03/27/2025
Miscellaneous Correction
Corrective Action Required
03/18/2025
3/27/25 Maintain storm inlet and perimeter protection -Remove silt and debris from inlet, replace damaged, worn gutter buddy and install with cinder blocks separating filter from inlet -Complete erosion control methods at perimeter
Occupancy Inspection - Codes Residential Ready for Temp CO 4/11/2025 04/10/2025
Miscellaneous Correction
Corrective Action Required
03/11/2025
-Deck stair landing is not installed -Outside AC unit is not installed -Seal gap in siding to foundation wall along the east side -Front porch soffit is not complete -Sod, splash pads and sump pump extension are not installed -Plot plan could not be completed due to snow on the ground -Sidewalk inspection must pass -Re establish erosion control at front of lot
Erosion Control Inspection Residential Failed 04/16/2025
Miscellaneous Correction
Corrective Action Required
03/27/2025
3/27/25 Maintain storm inlet and perimeter protection -Remove silt and debris from inlet, replace damaged, worn gutter buddy and install with cinder blocks separating filter from inlet -Complete erosion control methods at perimeter
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
04/16/2025
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. 4/16/25 Maintain storm inlet and perimeter protection -Remove silt and debris from inlet, replace damaged, worn gutter buddy and install with cinder blocks separating filter from inlet -Complete erosion control methods at perimeter **Notice of Violation issued
Occupancy Inspection - Codes Residential Not Ready 04/18/2025
Miscellaneous Correction
Corrective Action Required
04/10/2025
-Deck stair landing is not installed -Outside AC unit is not installed -Seal gap in siding to foundation wall along the east side -Front porch soffit is not complete -Sod, splash pads and sump pump extension are not installed -Plot plan could not be completed due to snow on the ground -Sidewalk inspection must pass -Re establish erosion control at front of lot
Miscellaneous Correction
Corrective Action Required
04/18/2025
4/18/25 -TCO extension request denied. House is in NOV status and still has no erosion control. No further inspections, or extensions will be issued or performed until erosion control has been addressed.
Documents & Images
Date Uploaded File Type Document Name
05/13/2024 WO #198 - ENGINEERED PLANS
05/13/2024 WO #198 - PERMIT APP
05/13/2024 WO #198 - PLOT PLAN
05/13/2024 WO #198 - TRUSS DETAILS
05/13/2024 WO #198 - TRUSS LAYOUT
05/14/2024 Permit Codes Residential Plan Review
05/14/2024 Approved Plans APPROVED PLANS
05/14/2024 Approved Plans APPROVED TRUSS LAYOUT
05/14/2024 Approved Plans APPROVED TRUSS PACKAGE
05/21/2024 LOT 198 CITY
05/21/2024 Permit Codes Residential Plan Review
05/21/2024 Plot Plan APPROVED PLOT PLAN
05/21/2024 Permit DS Building Permit
05/21/2024 Receipt Receipt for transaction:2024-003717
06/14/2024 Letter Stop Work Order
06/14/2024 Letter Stop Work Order
06/17/2024 3RD Party Insp Report THIRD PARTY FOOTING INSPECTION
06/18/2024 Letter INSPECTION SUMMARY
06/18/2024 Letter INSPECTION SUMMARY
06/25/2024 Letter INSPECTION SUMMARY
06/25/2024 Letter INSPECTION SUMMARY
06/26/2024 Letter INSPECTION SUMMARY
06/26/2024 Letter INSPECTION SUMMARY
06/26/2024 Letter INSPECTION SUMMARY
06/27/2024 Letter INSPECTION SUMMARY
08/21/2024 Letter INSPECTION SUMMARY
08/21/2024 Letter INSPECTION SUMMARY
10/17/2024 Letter INSPECTION SUMMARY
10/17/2024 Letter INSPECTION SUMMARY
10/17/2024 Letter INSPECTION SUMMARY
10/17/2024 Letter INSPECTION SUMMARY
10/29/2024 Letter INSPECTION SUMMARY
10/29/2024 Letter INSPECTION SUMMARY
10/29/2024 Letter INSPECTION SUMMARY
11/06/2024 Letter INSPECTION SUMMARY
11/06/2024 Letter INSPECTION SUMMARY
11/08/2024 Letter INSPECTION SUMMARY
11/08/2024 Letter INSPECTION SUMMARY
11/19/2024 Letter INSPECTION SUMMARY
11/19/2024 Letter INSPECTION SUMMARY
11/19/2024 Letter INSPECTION SUMMARY
11/20/2024 Letter INSPECTION SUMMARY
11/26/2024 Letter INSPECTION SUMMARY
11/27/2024 Letter INSPECTION SUMMARY
12/03/2024 Letter Stop Work Order
12/09/2024 24 site conditions
12/09/2024 24 site conditions 0
12/09/2024 Letter Stop Work Order
12/12/2024 Receipt Receipt for transaction:2024-009489
01/16/2025 Letter INSPECTION SUMMARY
01/21/2025 Letter INSPECTION SUMMARY
01/22/2025 Letter INSPECTION SUMMARY
01/22/2025 Certificate/License Codes Temporary Certificate of Occupancy
01/22/2025 Receipt Receipt for transaction:2025-000388
02/05/2025 Letter INSPECTION SUMMARY
02/11/2025 Letter Stop Work Order
02/11/2025 WO #198 - TCO Extension App
02/11/2025 Letter INSPECTION SUMMARY
02/11/2025 Certificate/License Codes Temporary Certificate of Occupancy
02/11/2025 Receipt Receipt for transaction:2025-000878
03/03/2025 WO #198 - TCO Extension App 3_3_25
03/11/2025 Letter INSPECTION SUMMARY
03/11/2025 Certificate/License Codes Temporary Certificate of Occupancy
03/11/2025 Receipt Receipt for transaction:2025-001418
03/18/2025 Letter INSPECTION SUMMARY
03/27/2025 Letter INSPECTION SUMMARY
04/10/2025 WO #198 - TCO Extension App 4_10_25
04/10/2025 Letter INSPECTION SUMMARY
04/11/2025 Certificate/License Codes Temporary Certificate of Occupancy
04/11/2025 Receipt Receipt for transaction:2025-002247
04/16/2025 Letter INSPECTION SUMMARY
04/16/2025 Letter Codes 10 Day Letter
04/18/2025 Application Form TCO EXTENSION
04/18/2025 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home