Permit Application Status

PRRES20242325


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20242325
Building Permit - Residential
Certificate of Occupancy
CLAYTON PROPERTIES GROUP INC
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSSES - UNFINISHED BASEMENT - COVERED DECK
05/08/2024
05/10/2024
04/11/2025
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CLAYTON PROPERTIES GROUP INC, Address:120 SE 30TH ST  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
BRUCER@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 05/10/2024
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 05/10/2024
7232302-Residential License Tax Fee $1,022.72 $1,022.72 Paid 05/10/2024
8331401-Water Tap Fee $3,760.00 $3,760.00 Paid 05/10/2024
8350015-Water Meter Fee $680.46 $680.46 Paid 05/10/2024
9110078-Valuation Fee New Single Family $1,583.93 $1,583.93 Paid 05/10/2024
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 12/12/2024
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 12/12/2024
9110080-3rd and Subsequent Inspection Fee (Per Hour) $75.00 $75.00 Paid 12/12/2024
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 12/12/2024
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 12/26/2024
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 01/02/2025
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 01/02/2025
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 01/22/2025
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 02/11/2025
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 03/11/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 7/1/2024 7/1/2024 07/01/2024
Misc
Informational
07/01/2024
Footing approved by David Ainsworth on 6/28/24
Erosion Control Inspection Residential Failed 07/01/2024
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
07/01/2024
7/1/24 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -RESTORE SILT FENCE -PROTECT STORM INLET -PROVIDE EROSION CONTROL METHODS AT SPOILS PILE ON ADJACENT LOT **STOP WORK WILL BE ISSUED IF NOT IN COMPLIANCE
Erosion Control Inspection Residential Failed 7/5/2024 7/5/2024 07/05/2024
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
07/01/2024
7/5/24 -RESTORE SILT FENCE -PROTECT STORM INLET -PROVIDE EROSION CONTROL METHODS AT SPOILS PILE ON ADJACENT LOT
Water Service Inspection - R Partial 7/17/2024 7/17/2024 07/17/2024
Sewer Service Inspection - R Passed 7/17/2024 7/17/2024 07/17/2024
Misc
Informational
07/17/2024
- Must maintain erosion control
Water Service Inspection - R Passed 7/18/2024 07/18/2024
Underslab Plumbing Inspection - Residential Passed 7/22/2024 7/22/2024 07/22/2024
Erosion Control Inspection Residential Partial 7/22/2024 7/22/2024 07/22/2024
DCM3 ESC REQUIRED 2 DAY
Resolved
07/22/2024
7/5/24 -RESTORE SILT FENCE
Erosion Control Inspection Residential Failed 08/16/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
08/16/2024
8/16/24 DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -RESTORE SILT FENCE AND CLEAN SILT AND DEBRIS FROM STREETS
All Rough Inspection - Residential Failed 8/30/2024 8/30/2024 08/30/2024
Misc
Informational
08/30/2024
-Exterior PFH ONLY ok to cover
Erosion Control Inspection Residential Failed 8/30/2024 8/30/2024 08/30/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
08/16/2024
8/30/24 DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -RESTORE DOWN SILT FENCE, INSTALL SILT FENCE AT MISSING AREA, CLEAN SILT AND DEBRIS FROM STREETS AND STORM INLET. MAINTAIN GRAVEL DRIVE WITH MIN 6" LIFT OF MIN 3/4" GRAVEL
Electrical Service Inspection Failed 10/2/2024 10/2/2024 10/02/2024
Miscellaneous Correction
Corrective Action Required
10/02/2024
-Provide city approved, stamped plans for inspection
All Rough Inspection - Residential Not Ready 10/2/2024 10/2/2024 10/02/2024
Misc
Informational
08/30/2024
-Exterior PFH ONLY ok to cover
Miscellaneous Correction
Corrective Action Required
10/02/2024
-Provide city approved, stamped plans for inspection
Gas Service Inspection - Residential Failed 10/2/2024 10/2/2024 10/02/2024
Misc
Corrective Action Required
10/02/2024
-Provide city approved, stamped plans for inspection
Erosion Control Inspection Residential Failed 10/2/2024 10/2/2024 10/02/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
08/30/2024
10/2/24 DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -Restore silt fence at perimeter, clean debris from street
Erosion Control Inspection Residential Failed 10/7/2024 10/7/2024 10/07/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
10/02/2024
Maintain gravel filter with min 6" lift of min 3/4" gravel
Gas Service Inspection - Residential Failed 10/7/2024 10/7/2024 10/07/2024
Misc
Corrective Action Required
10/02/2024
-No pressure gauge
Electrical Service Inspection Passed 10/7/2024 10/7/2024 10/07/2024
Miscellaneous Correction
Resolved
10/07/2024
-Provide city approved, stamped plans for inspection
All Rough Inspection - Residential Not Ready 10/7/2024 10/7/2024 10/07/2024
Misc
Informational
10/02/2024
-Exterior PFH ONLY ok to cover
Miscellaneous Correction
Corrective Action Required
10/02/2024
Not ready for inspection. List is incomplete and will change. Complete the following items before rescheduling: -Uncover front port roof framing for inspection -Tighten anchor bolts -Anchor bolts to be in middle third of plate -Fur out and Fireblock dryer box space for R13 insulation -Strap over bored top plate at both sides of dryer duct. Strapping at fur out wall is not approved. This wall is 2x6 wall and requires 2x6 top plate -Protect dryer duct min 2” below plate line -Nail top plate to header at PFH per detail -Strap top plate all locations at rear garage wall top plate lapped less than 24” -Seal top plate penetration at garage back wall -Fireblock top of unused chase at owner’s entry -Install all truss hold downs at back garage wall -Missing (2) 2x4 stud packs and (2) H2.5s at GT locations -Provide gas pressure test and schedule for gas service inspection at time of all rough
Gas Service Inspection - Residential Failed 10/10/2024 10/10/2024 10/10/2024
Misc
Corrective Action Required
10/07/2024
-No pressure gauge
Erosion Control Inspection Residential Partial 10/10/2024
DCM2 ESC DEFICIENT INSTALLATION
Resolved
10/10/2024
Maintain gravel filter with min 6" lift of min 3/4" gravel
Misc
Informational
10/10/2024
In compliance at time of inspection
All Rough Inspection - Residential Failed 10/10/2024 10/10/2024 10/10/2024
Misc
Informational
10/07/2024
-Exterior PFH ONLY ok to cover
Miscellaneous Correction
Corrective Action Required
10/07/2024
-Uncover front port roof framing for inspection-STILL COVERED -Fireblock top of unused chase at owner’s entry-SEAL GAPS -Protect pex lines at laundry 2” above sole plate -Strap over bored top plate at exterior wall master bathroom -Protect pex line for fridge 2” above plate at master bed -Install roof boot at range vent -Protect nm for flood light at dining -Receptacle required at wall space of owner’s entry by stairs/kitchen -Missing truss screw at front bedroom wall near entry -Strap top plate lapped less than 24” at front bedroom window header -Provide mechanical connection to bearing plate to resist 125 lb of uplift per note 6 for trusses C04 and C05 in front bedroom -Missing truss screws at hip trusses at covered deck -Deck posts to be full height 6x6s -Provide engineered correction for exterior walls not connected at top plate in basement bump out by deck -Anchor bolts to be in middle third of plate at bump out wall across from basement slider -Sister over notched studs at foundation cripple walls both sides -Strap top plate lapped less than 24” at left side of beam by electrical panel and replace top plate cut all the way through at right side of beam or provide an engineered correction -Provide gas pressure test and schedule for gas service inspection at time of all rough-NO PRESSURE IN GAUGE
Erosion Control Inspection Residential Failed 10/17/2024 10/17/2024 10/17/2024
Misc
Resolved
10/17/2024
In compliance at time of inspection
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
10/17/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -RESTORE SILT FENCE
Gas Service Inspection - Residential Failed 10/17/2024 10/17/2024 10/17/2024
Misc
Resolved
10/17/2024
-No pressure gauge
G2417.4.1 Test Pressure
Corrective Action Required
10/17/2024
INSPECTION, TESTING AND PURGING. AMENDED 7-945. The test pressure to be used shall be not less than one and one-half times the proposed maximum working pressure, but not less than 10 psig (68.9kPa) irrespective of design pressure. For welded piping, and for piping carrying gas at pressures in excess of fourteen (14) inches water column pressure, the test pressure shall not be less than 60 psig. Where the test pressure exceeds 125 psig (862 kPa gauge), the test pressure shall not exceed a value that produces a hoop stress in the piping greater than 50 percent of the specified minimum yield strength of the pipe.
All Rough Inspection - Residential Failed 10/17/2024 10/17/2024 10/17/2024
Misc
Informational
10/10/2024
-Exterior PFH ONLY ok to cover
Miscellaneous Correction
Corrective Action Required
10/10/2024
-Fireblock top of unused chase at owner’s entry-SEAL GAP-NOT DONE -Install roof boot at range vent-NOT DONE -Protect nm for flood light at dining-NOT DONE -Deck posts to be full height 6x6s-NOT DONE -Anchor bolts to be in middle third of plate at bump out wall across from basement slider-TIGHTEN NUTS -Provide gas pressure test and schedule for gas service inspection at time of all rough-ONLY 4 LBS OF PRESSURE IN GAUGE
Erosion Control Inspection Residential Failed 10/24/2024 10/24/2024 10/24/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
10/17/2024
10/17/24 DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -RESTORE SILT FENCE
DCM5 ESC INSP DENIED
Corrective Action Required
10/24/2024
10/24/24 REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. -Denied per previous failed erosion control inspection on 10/17/24 -Restore silt fence, clean debris from street, remove loose trash from site, clean silt from storm inlet
All Rough Inspection - Residential Failed 10/24/2024 10/24/2024 10/24/2024
Misc
Informational
10/17/2024
-Exterior PFH ONLY ok to cover
Miscellaneous Correction
Corrective Action Required
10/17/2024
-Fireblock top of unused chase at owner’s entry-SEAL GAP-NOT DONE -Install roof boot at range vent-NOT DONE -Protect nm for flood light at dining-NOT DONE -Deck posts to be full height 6x6s-NOT DONE -Anchor bolts to be in middle third of plate at bump out wall across from basement slider-TIGHTEN NUTS -Provide gas pressure test and schedule for gas service inspection at time of all rough-ONLY 4 LBS OF PRESSURE IN GAUGE
Miscellaneous Correction
Corrective Action Required
10/24/2024
10/24/24 REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. -Denied per previous failed erosion control inspection on 10/17/24 -Restore silt fence, clean debris from street, remove loose trash from site, clean silt from storm inlet
All Rough Inspection - Residential Passed 10/28/2024 10/28/2024 10/28/2024
Misc
Informational
10/24/2024
-Exterior PFH ONLY ok to cover
Miscellaneous Correction
Resolved
10/28/2024
-Fireblock top of unused chase at owner’s entry-SEAL GAP-NOT DONE -Install roof boot at range vent-NOT DONE -Protect nm for flood light at dining-NOT DONE -Deck posts to be full height 6x6s-NOT DONE -Anchor bolts to be in middle third of plate at bump out wall across from basement slider-TIGHTEN NUTS -Provide gas pressure test and schedule for gas service inspection at time of all rough-ONLY 4 LBS OF PRESSURE IN GAUGE
Miscellaneous Correction
Resolved
10/28/2024
10/24/24 REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. -Denied per previous failed erosion control inspection on 10/17/24 -Restore silt fence, clean debris from street, remove loose trash from site, clean silt from storm inlet
Erosion Control Inspection Residential Partial 10/28/2024 10/28/2024
DCM2 ESC DEFICIENT INSTALLATION
Resolved
10/28/2024
10/17/24 DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -RESTORE SILT FENCE
DCM5 ESC INSP DENIED
Resolved
10/28/2024
10/24/24 REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. -Denied per previous failed erosion control inspection on 10/17/24 -Restore silt fence, clean debris from street, remove loose trash from site, clean silt from storm inlet
Driveway Inspection Partial 11/12/2024 11/12/2024 11/12/2024
Misc
Informational
11/12/2024
11/12/24 Tuesday JMJ Contractor passed pre-inspection of forms & materials.
Sidewalk Inspection Partial 11/12/2024 11/12/2024 11/12/2024
Misc
Informational
11/12/2024
11/12/24 Tuesday JMJ Sidewalk passed pre-inspection of forms and materials.
Sidewalk Inspection Passed 11/14/2024 11/14/2024 11/20/2024
Misc
Informational
11/12/2024
11/12/24 Tuesday JMJ Sidewalk passed pre-inspection of forms and materials. 11/20/24 Wednesday JMJ Sidewalk passed
Driveway Inspection Passed 11/14/2024 11/14/2024 11/20/2024
Misc
Informational
11/12/2024
11/12/24 Tuesday JMJ Contractor passed pre-inspection of forms & materials. 11/20/24 Wednesday JMJ Driveway passed
Erosion Control Inspection Residential Failed 11/21/2024 11/21/2024 11/21/2024
DCM5 ESC INSP DENIED
Corrective Action Required
11/21/2024
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. -Provide erosion control methods at perimeter and clean silt from street
Gas Service Inspection - Residential Failed 11/21/2024 11/21/2024 11/21/2024
G2417.4.1 Test Pressure
Informational
11/21/2024
INSPECTION, TESTING AND PURGING. AMENDED 7-945. The test pressure to be used shall be not less than one and one-half times the proposed maximum working pressure, but not less than 10 psig (68.9kPa) irrespective of design pressure. For welded piping, and for piping carrying gas at pressures in excess of fourteen (14) inches water column pressure, the test pressure shall not be less than 60 psig. Where the test pressure exceeds 125 psig (862 kPa gauge), the test pressure shall not exceed a value that produces a hoop stress in the piping greater than 50 percent of the specified minimum yield strength of the pipe.
Misc
Corrective Action Required
11/21/2024
11/21/24 REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. -Provide erosion control methods at perimeter and clean silt from street
Erosion Control Inspection Residential Partial 11/27/2024 11/27/2024 11/27/2024
DCM5 ESC INSP DENIED
Resolved
11/27/2024
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. -Provide erosion control methods at perimeter and clean silt from street
Gas Service Inspection - Residential Not Ready 11/27/2024 11/27/2024 11/27/2024
G2417.4.1 Test Pressure
Informational
11/21/2024
INSPECTION, TESTING AND PURGING. AMENDED 7-945. The test pressure to be used shall be not less than one and one-half times the proposed maximum working pressure, but not less than 10 psig (68.9kPa) irrespective of design pressure. For welded piping, and for piping carrying gas at pressures in excess of fourteen (14) inches water column pressure, the test pressure shall not be less than 60 psig. Where the test pressure exceeds 125 psig (862 kPa gauge), the test pressure shall not exceed a value that produces a hoop stress in the piping greater than 50 percent of the specified minimum yield strength of the pipe. 11/27/24 -NO GAUGE PRESENT
Misc
Resolved
11/27/2024
11/21/24 REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. -Provide erosion control methods at perimeter and clean silt from street
Erosion Control Inspection Residential Partial 12/03/2024
Gas Service Inspection - Residential Passed 12/3/2024 12/3/2024 12/03/2024
G2417.4.1 Test Pressure
Resolved
12/03/2024
INSPECTION, TESTING AND PURGING. AMENDED 7-945. The test pressure to be used shall be not less than one and one-half times the proposed maximum working pressure, but not less than 10 psig (68.9kPa) irrespective of design pressure. For welded piping, and for piping carrying gas at pressures in excess of fourteen (14) inches water column pressure, the test pressure shall not be less than 60 psig. Where the test pressure exceeds 125 psig (862 kPa gauge), the test pressure shall not exceed a value that produces a hoop stress in the piping greater than 50 percent of the specified minimum yield strength of the pipe. 11/27/24 -NO GAUGE PRESENT
Occupancy Inspection - Codes Residential Not Ready 12/24/2024 12/24/2024 12/24/2024
Misc
Corrective Action Required
10/28/2024
Note for all rough: -Deck posts to be full height 6x6s
Misc
Corrective Action Required
12/24/2024
12/24/24 -Not ready for occupancy inspection -Open electrical at front (receptacles not installed) -Address must be contrasting color to background (cannot be black on black) -Deck incomplete (No decking or railing is installed) -Address deck posts from rough in inspection -Water meter covered -Fee assessed
Erosion Control Inspection Residential Failed 12/24/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
12/24/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -Clean debris form street and storm inlet
Occupancy Inspection - Codes Residential Not Ready 12/27/2024 12/27/2024 12/27/2024
Misc
Corrective Action Required
12/24/2024
Note for all rough: -Deck posts to be full height 6x6s
Misc
Corrective Action Required
12/24/2024
12/24/24 -Not ready for occupancy inspection -Deck incomplete (No decking or railing is installed) -Address deck posts from rough in inspection -Water meter covered -Fee assessed
Misc
Corrective Action Required
12/27/2024
Not ready 12/27/24 - No gaurd railing at deck inspection not done
Occupancy Inspection - Codes Residential Failed 12/30/2024 12/30/2024 12/30/2024
Misc
Resolved
12/30/2024
Note for all rough: -Deck posts to be full height 6x6s
Misc
Resolved
12/30/2024
12/24/24 -Not ready for occupancy inspection -Deck incomplete (No decking or railing is installed) -Address deck posts from rough in inspection -Water meter covered -Fee assessed
Misc
Resolved
12/30/2024
Not ready 12/27/24 - No gaurd railing at deck inspection not done
Misc
Corrective Action Required
12/30/2024
-final grade and sod and sod -obtain issued lawn irrigation permit -splash blocks and sump pump discharge to extend 35” from foundation -provide adequate illumination for premise identification -uncover covered water meter ensure meter is 14”-18” from top of meter to well lid ring -complete deck guard rails and handrails -provide landing at deck stairs -provide secondary locking device for basement slider
Occupancy Inspection - Codes Residential Failed 12/31/2024 12/31/2024 12/31/2024
Misc
Corrective Action Required
12/30/2024
-pay all fees -final grade and sod and sod -obtain issued lawn irrigation permit -splash blocks and sump pump discharge to extend 36” from foundation -provide adequate illumination for premise identification -uncover covered water meter ensure meter is 14”-18” from top of meter to well lid ring -Deck handrails must extend to a point directly above the lowest riser -Complete electrical being added in kitchen ceiling
Occupancy Inspection - Codes Residential Ready for Temp CO 1/2/2025 1/2/2025 01/02/2025
Misc
Corrective Action Required
12/31/2024
-pay all fees -final grade and sod and sod -obtain issued lawn irrigation permit -splash blocks and sump pump discharge to extend 36” from foundation -provide adequate illumination for premise identification -uncover covered water meter ensure meter is 14”-18” from top of meter to well lid ring -Deck handrails must extend to a point directly above the lowest riser
Occupancy Inspection - Codes Residential Ready for Temp CO 01/22/2025
Misc
Corrective Action Required
01/02/2025
-final grade and sod -obtain issued lawn irrigation permit -splash blocks and sump pump discharge to extend 36” from foundation -uncover covered water meter ensure meter is 14”-18” from top of meter to well lid ring -Deck handrails must extend to a point directly above the lowest riser
Occupancy Inspection - Codes Residential Ready for Temp CO 02/11/2025
Misc
Corrective Action Required
01/22/2025
-final grade and sod -obtain issued lawn irrigation permit -splash blocks and sump pump discharge to extend 36” from foundation -uncover covered water meter ensure meter is 14”-18” from top of meter to well lid ring -Deck handrails must extend to a point directly above the lowest riser
Occupancy Inspection - Codes Residential Ready for Temp CO 03/11/2025
Misc
Corrective Action Required
02/11/2025
-final grade and sod -obtain issued lawn irrigation permit -splash blocks and sump pump discharge to extend 36” from foundation -uncover covered water meter ensure meter is 14”-18” from top of meter to well lid ring -Deck handrails must extend to a point directly above the lowest riser
Erosion Control Inspection Residential Failed 03/18/2025
DCM2 ESC DEFICIENT INSTALLATION
Resolved
03/18/2025
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -Clean debris form street and storm inlet
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
03/18/2025
3/18/25 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Occupancy Inspection - Codes Residential Full C of O 4/11/2025 04/11/2025
Misc
Resolved
04/11/2025
-final grade and sod -obtain issued lawn irrigation permit -splash blocks and sump pump discharge to extend 36” from foundation -uncover covered water meter ensure meter is 14”-18” from top of meter to well lid ring -Deck handrails must extend to a point directly above the lowest riser
Plot Plan Inspection Passed 4/11/2025 04/11/2025
Erosion Control Inspection Residential Passed 04/11/2025
DCM3 ESC REQUIRED 2 DAY
Resolved
04/11/2025
3/18/25 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Documents & Images
Date Uploaded File Type Document Name
05/08/2024 WO #130 - ENGINEERED PLANS
05/08/2024 WO #130 - PERMIT APP
05/08/2024 WO #130 - PLOT PLAN
05/08/2024 WO #130 - TRUSS DETAILS
05/08/2024 WO #130 - TRUSS LAYOUT
05/09/2024 Approved Plans APPROVED PLANS
05/09/2024 Plot Plan APPROVED PLOT PLAN
05/09/2024 Approved Plans APPROVED TRUSS LAYOUT
05/09/2024 Approved Plans APPROVED TRUSS PACKAGE
05/10/2024 Permit Codes Residential Plan Review
05/10/2024 Permit DS Building Permit
05/10/2024 Receipt Receipt for transaction:2024-003245
06/18/2024 Approved Plans APPROVED PIER PLAN
06/28/2024 M L Crose 2135 NW Killarney Lane LSMO Woodside Ridge Lot 130 Footing Inspection Report 6-28-24
07/01/2024 Letter INSPECTION SUMMARY
07/01/2024 Letter INSPECTION SUMMARY
07/05/2024 Letter INSPECTION SUMMARY
07/17/2024 Letter INSPECTION SUMMARY
07/17/2024 Letter INSPECTION SUMMARY
07/18/2024 Letter INSPECTION SUMMARY
07/22/2024 Letter INSPECTION SUMMARY
07/22/2024 Letter INSPECTION SUMMARY
08/16/2024 Letter INSPECTION SUMMARY
08/16/2024 Letter INSPECTION SUMMARY
08/30/2024 Letter INSPECTION SUMMARY
08/30/2024 Letter INSPECTION SUMMARY
10/02/2024 Letter INSPECTION SUMMARY
10/02/2024 Letter INSPECTION SUMMARY
10/02/2024 Letter INSPECTION SUMMARY
10/02/2024 Letter INSPECTION SUMMARY
10/07/2024 Letter INSPECTION SUMMARY
10/07/2024 Letter INSPECTION SUMMARY
10/07/2024 Letter INSPECTION SUMMARY
10/07/2024 Letter INSPECTION SUMMARY
10/10/2024 Letter INSPECTION SUMMARY
10/10/2024 Letter INSPECTION SUMMARY
10/10/2024 Letter INSPECTION SUMMARY
10/15/2024 3RD Party Insp Report 130 Woodside Ridge- Engineer Letter
10/17/2024 Letter INSPECTION SUMMARY
10/17/2024 Letter INSPECTION SUMMARY
10/17/2024 Letter INSPECTION SUMMARY
10/24/2024 Letter INSPECTION SUMMARY
10/24/2024 Letter INSPECTION SUMMARY
10/28/2024 Letter INSPECTION SUMMARY
10/28/2024 Letter INSPECTION SUMMARY
11/12/2024 Letter INSPECTION SUMMARY
11/12/2024 Letter INSPECTION SUMMARY
11/20/2024 Letter INSPECTION SUMMARY
11/20/2024 Letter INSPECTION SUMMARY
11/21/2024 Letter INSPECTION SUMMARY
11/21/2024 Letter INSPECTION SUMMARY
11/27/2024 Letter INSPECTION SUMMARY
11/27/2024 Letter INSPECTION SUMMARY
12/03/2024 Letter INSPECTION SUMMARY
12/03/2024 Letter INSPECTION SUMMARY
12/12/2024 Receipt Receipt for transaction:2024-009487
12/24/2024 Letter INSPECTION SUMMARY
12/24/2024 Letter INSPECTION SUMMARY
12/26/2024 Receipt Receipt for transaction:2024-009665
12/27/2024 Letter INSPECTION SUMMARY
12/30/2024 Letter INSPECTION SUMMARY
12/31/2024 Letter INSPECTION SUMMARY
01/02/2025 Letter INSPECTION SUMMARY
01/02/2025 Certificate/License Codes Temporary Certificate of Occupancy
01/02/2025 Receipt Receipt for transaction:2025-000007
01/22/2025 WO #130 - TCO Extension 1_22_25
01/22/2025 Letter INSPECTION SUMMARY
01/22/2025 Certificate/License Codes Temporary Certificate of Occupancy
01/22/2025 Receipt Receipt for transaction:2025-000387
02/11/2025 WO #130 - TCO Extension App
02/11/2025 Letter INSPECTION SUMMARY
02/11/2025 Certificate/License Codes Temporary Certificate of Occupancy
02/11/2025 Receipt Receipt for transaction:2025-000877
03/03/2025 WO #130 - TCO Extension 1_22_25
03/11/2025 Letter INSPECTION SUMMARY
03/11/2025 Certificate/License Codes Temporary Certificate of Occupancy
03/11/2025 Receipt Receipt for transaction:2025-001417
03/18/2025 Letter INSPECTION SUMMARY
04/10/2025 Plot Plan APPROVED AS GRADED PLOT PLAN
04/11/2025 Letter Codes Final Certificate of Occupancy
04/11/2025 Letter Field Certificate of Occupancy
04/11/2025 Letter INSPECTION SUMMARY
04/11/2025 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home